Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 46(4): 273-278, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36751953

RESUMEN

BACKGROUND: The subcutaneous implantable-defibrillator (S-ICD) is a relatively new alternative to the transvenous ICD system to minimize intravascular lead-related complications. This paper presents outcome of SICD implantation in patients enrolled in Iran S-ICD registry. METHODS: Between October 2015 and June 2022, this prospective multicenter national registry included 223 patients with a standard indication for an ICD, who neither required bradycardia pacing nor needed cardiac resynchronization to evaluate the early post-implant complications and long-term follow-up results of the S-ICD system. RESULTS: The mean age of the patients was 45 ± 17 years. The majority (79.4%) were male. Ischemic cardiomyopathy (39.5%) was the most common underlying disorder among patients selected for S-ICD implant. Most study patients (68.6%) had ICD for primary prevention of sudden cardiac death. Seven patients (3.1%) were found to have suboptimal lead positions. Six patients (2.7%) developed a pocket hematoma; all were managed medically. During a mean follow-up of 2 years, the appropriate therapy was recorded in 13% of the patients and inappropriate ICD intervention mainly due to supraventricular tachycardia in 8.9%. Pocket infection was observed in four patients (1.8%) and five patients (2.2%) died mainly due to heart failure. CONCLUSION: S-ICDs were effective at detecting and treating both induced and spontaneous ventricular arrhythmias. Major clinical complications were rare.


Asunto(s)
Desfibriladores Implantables , Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Estudios Prospectivos , Irán , Resultado del Tratamiento , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Sistema de Registros
2.
J Tehran Heart Cent ; 16(1): 42-44, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35082868

RESUMEN

Atrial fibrillation (AF) is the most commonly treated arrhythmia in clinical practice and is often found in association with an atrial septal defect (ASD). However, ASD closure rarely confers complete arrhythmia control. A 23-year-old man presented to our center with frequent episodes of palpitations. AF was documented in 12-lead electrocardiography, and echocardiography showed a secundum-type ASD, 14 mm in size, with a significant left-to-right shunt. ASD closure was performed successfully with an ASD occluder device with no residual shunting. During follow-up, the patient experienced several episodes of AF. Thirteen months after the ASD closure, cryoballoon pulmonary vein isolation was done successfully with no complications. During a 12-month follow-up, he had no symptoms or AF recurrences, and echocardiography showed no residual shunting. This study showed that cryoballoon pulmonary vein isolation could be performed successfully without residual shunts in patients with ASD closure devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA