Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Echocardiography ; 39(5): 732-734, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35342973

RESUMEN

We present a case of a 61-year-old female who, after undergoing frozen elephant trunk surgery, was found to have an unexpected left ventricular pseudoaneurysm on transthoracic echocardiogram. The pseudoaneurysm was caused by the left ventricular vent catheter constantly impinging the LV wall of the beating heart during surgery. Contrast echocardiography, cardiac magnetic resonance imaging and computed tomography (CT) imaging confirmed the diagnosis and served for follow-up demonstrating the narrow neck and outpouching structure on the apical lateral wall. The patient remains asymptomatic two years after the operation and is being followed up with echocardiography and CT imaging.


Asunto(s)
Aneurisma Falso , Aneurisma Falso/diagnóstico , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Ecocardiografía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
2.
J Card Surg ; 37(12): 4598-4605, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36284463

RESUMEN

INTRODUCTION: In mitral valve replacement (MVR), sudden increases in afterload and disruption of the annular-chordal-papillary-left-ventricular wall causes left ventricular (LV) dysfunction in the early postoperative period. Preservation of the posterior mitral leaflet apparatus (MVR-P) has a favorable outcome on LV function. However, there is paucity of data on the impact of complete preservation of the sub-valvular apparatus (MVR-C). OBJECTIVE: We investigated the impact of MVR-P and MVR-C on baseline and 3-months postoperative LV ejection fraction (EF) and global longitudinal strain (GLS). METHODS: We retrospectively analyzed a cohort of 29 MVR-P and 19 MVR-C patients with complete echocardiography data at our unit, who were operated between 2008 and 2017. Between-group changes in LVEF and GLS were compared using independent sample T-test. RESULTS: Median age was 59 years (IQR 50-69 years). Baseline LVEF was 58% (51%- 60%). Baseline GLS was -18.4 (-21.2 to -15.5). There were no significant between-group differences between all baseline demographics and echocardiographic markers. There was significantly higher absolute postoperative LVEF in MVR-C patients (p = 0.029). There was also significant worsening in LVEF (p = 0.0121) and GLS (p < 0.0001) after MVR-P and not MVR-C, suggesting no reduction in LV function post-MVR-C but a reduction post-MVR-P. There was significantly less postoperative worsening of GLS per patient in MVR-C group as compared to the MVR-P group (p = 0.023), indicating better preservation of LV function. There was also a smaller decline in LVEF per patient in the MVR-C as compared to the MVR-P group, although not statistically significant (p = 0.23). CONCLUSION: MVR with complete preservation of the sub-valvular apparatus shows a favorable impact on the longitudinal function of the heart at 3 months. Further studies with larger patient numbers are indicated to investigate the long-term results of this surgical approach.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Humanos , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Función Ventricular Izquierda , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/complicaciones , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Izquierda/etiología , Implantación de Prótesis de Válvulas Cardíacas/métodos
3.
JAMA ; 327(19): 1875-1887, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35579641

RESUMEN

Importance: Transcatheter aortic valve implantation (TAVI) is a less invasive alternative to surgical aortic valve replacement and is the treatment of choice for patients at high operative risk. The role of TAVI in patients at lower risk is unclear. Objective: To determine whether TAVI is noninferior to surgery in patients at moderately increased operative risk. Design, Setting, and Participants: In this randomized clinical trial conducted at 34 UK centers, 913 patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk due to age or comorbidity were enrolled between April 2014 and April 2018 and followed up through April 2019. Interventions: TAVI using any valve with a CE mark (indicating conformity of the valve with all legal and safety requirements for sale throughout the European Economic Area) and any access route (n = 458) or surgical aortic valve replacement (surgery; n = 455). Main Outcomes and Measures: The primary outcome was all-cause mortality at 1 year. The primary hypothesis was that TAVI was noninferior to surgery, with a noninferiority margin of 5% for the upper limit of the 1-sided 97.5% CI for the absolute between-group difference in mortality. There were 36 secondary outcomes (30 reported herein), including duration of hospital stay, major bleeding events, vascular complications, conduction disturbance requiring pacemaker implantation, and aortic regurgitation. Results: Among 913 patients randomized (median age, 81 years [IQR, 78 to 84 years]; 424 [46%] were female; median Society of Thoracic Surgeons mortality risk score, 2.6% [IQR, 2.0% to 3.4%]), 912 (99.9%) completed follow-up and were included in the noninferiority analysis. At 1 year, there were 21 deaths (4.6%) in the TAVI group and 30 deaths (6.6%) in the surgery group, with an adjusted absolute risk difference of -2.0% (1-sided 97.5% CI, -∞ to 1.2%; P < .001 for noninferiority). Of 30 prespecified secondary outcomes reported herein, 24 showed no significant difference at 1 year. TAVI was associated with significantly shorter postprocedural hospitalization (median of 3 days [IQR, 2 to 5 days] vs 8 days [IQR, 6 to 13 days] in the surgery group). At 1 year, there were significantly fewer major bleeding events after TAVI compared with surgery (7.2% vs 20.2%, respectively; adjusted hazard ratio [HR], 0.33 [95% CI, 0.24 to 0.45]) but significantly more vascular complications (10.3% vs 2.4%; adjusted HR, 4.42 [95% CI, 2.54 to 7.71]), conduction disturbances requiring pacemaker implantation (14.2% vs 7.3%; adjusted HR, 2.05 [95% CI, 1.43 to 2.94]), and mild (38.3% vs 11.7%) or moderate (2.3% vs 0.6%) aortic regurgitation (adjusted odds ratio for mild, moderate, or severe [no instance of severe reported] aortic regurgitation combined vs none, 4.89 [95% CI, 3.08 to 7.75]). Conclusions and Relevance: Among patients aged 70 years or older with severe, symptomatic aortic stenosis and moderately increased operative risk, TAVI was noninferior to surgery with respect to all-cause mortality at 1 year. Trial Registration: isrctn.com Identifier: ISRCTN57819173.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
4.
Echocardiography ; 38(1): 103-113, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33067903

RESUMEN

Apical hypertrophic cardiomyopathy (ApHCM) and apical displacement of papillary muscles (ADPM) are two different pathologies with a number of similar imaging findings that may hamper adequate diagnosis. While ApHCM is associated with increased rate of mortality, ADPM commonly presents with a benign course and differential diagnosis is of great importance. Clinical assessment and 2D echocardiography cannot sufficiently differentiate these conditions, however, and advanced echocardiographic methods may facilitate diagnosis. Although echocardiography is the first-line imaging method in the diagnostic algorithm, cardiac magnetic resonance imaging (CMRI) is the gold standard for evaluating patients due to good spatial resolution and myocardial tissue characterization abilities. When CMRI is contraindicated, cardiac computed tomography may be an alternative reliable method that can also give information about the coronary anatomy. Nuclear imaging may also provide supplementary data regarding hypertrophy and coronary arteries when there is a suspicion of ischemia.


Asunto(s)
Cardiomiopatía Hipertrófica , Músculos Papilares , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Diagnóstico Diferencial , Ecocardiografía , Electrocardiografía , Humanos , Imagen Multimodal , Músculos Papilares/diagnóstico por imagen
5.
J Clin Ultrasound ; 49(8): 805-807, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33644857

RESUMEN

Accessory mitral valve tissue is a rare congenital cardiac abnormality that sometimes can cause left ventricular outflow tract obstruction. We herein present the case of a 55-year-old male with an incidental finding of accessory mitral valve tissue on transthoracic echocardiography. The patient was managed conservatively as accessory tissue was not causing left ventricular outflow obstruction and there were no hemodynamic consequences.


Asunto(s)
Cardiopatías Congénitas , Obstrucción del Flujo Ventricular Externo , Adulto , Ecocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología
6.
Echocardiography ; 37(11): 1855-1859, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-33011989

RESUMEN

Papillary muscle (PM) rupture can usually complicate inferior or posterior myocardial infarctions, but selective PM infarction is extremely rare, and the exact underlying pathophysiological mechanism is not entirely clear. We present a case of PM rupture due to isolated PM infarction in a patient with unobstructed coronary arteries, which could be misdiagnosed as a vegetation or other mass given the absence of regional wall motion abnormalities (RWMAs) on transthoracic echocardiogram. Our case highlights that in patients with severe mitral regurgitation and associated mitral valve mass, the absence of RWMAs should not exclude ischemic PM rupture from differential diagnosis.


Asunto(s)
Enfermedad de la Arteria Coronaria , Rotura Cardíaca Posinfarto , Insuficiencia de la Válvula Mitral , Infarto del Miocardio , Rotura Cardíaca Posinfarto/diagnóstico por imagen , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Infarto del Miocardio/diagnóstico por imagen , Músculos Papilares/diagnóstico por imagen
7.
Echocardiography ; 37(2): 363-365, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-32045044

RESUMEN

We present a case of a 70-year-old woman with exertional shortness of breath. A transthoracic echocardiogram showed a large mass on the ventricular side of the pulmonary valve. The anatomy of the mass was additionally investigated with a transesophageal echocardiogram, which delineated the anatomical details of the structure. The mass was surgically excised, and histopathology confirmed a cardiac papillary fibroelastoma.


Asunto(s)
Fibroelastoma Papilar Cardíaco , Fibroma , Neoplasias Cardíacas , Válvula Pulmonar , Anciano , Ecocardiografía Transesofágica , Femenino , Fibroma/diagnóstico por imagen , Fibroma/cirugía , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/cirugía , Humanos , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía
8.
Echocardiography ; 37(6): 808-814, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32524654

RESUMEN

BACKGROUND: Studies determining the reliability of the World Heart Federation (WHF) anterior mitral valve leaflet (AMVL) measurement are limited by the introduction of bias in their test-retest analyses. This study sought to determine the reliability of the current AMVL measurement while controlling for systematic bias. METHODS: Retrospective analysis of echocardiographic data from 16 patients with previous acute rheumatic fever was performed. Included in this study was an optimized cine loop of the mitral valve (MV) [reader-optimized measurement (ROM]) in the parasternal long-axis view and an optimized still image of the MV obtained from the same cine loop [specialist-optimized image (SOI)]. Each still image and associated cine loop was quadruplicated and randomized to determine intra- and inter-rater agreement and quantify the impact of zoom on AMVL measurement. RESULTS: Specialist-optimized image without zoom reflected the highest degree of agreement in both cohorts with an ICC of 0.29 and 0.46. The agreement in ROM images without zoom was ICC of 0.23 and 0.45. The addition of zoom to SOI decreased agreement further to an ICC of 0.20 and 0.36. The setting associated with the poorest agreement profile was ROI with zoom with an ICC of 0.13 and 0.34, respectively. The intra-rater agreement between readers in both cohorts was moderate across all settings with an ICC ranging between 0.64 and 0.86. CONCLUSIONS: The WHF AMVL measurement is only moderately repeatable within readers and demonstrates poor reproducibility that was not improved by the addition of a zoom-optimized protocol. Given our study findings, we cannot advocate the current WHF AMVL measurement as a reliable assessment for RHD.


Asunto(s)
Insuficiencia de la Válvula Mitral , Cardiopatía Reumática , Humanos , Válvula Mitral/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Cardiopatía Reumática/diagnóstico por imagen
9.
J Mol Cell Cardiol ; 114: 20-28, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29055654

RESUMEN

BACKGROUND: Mouse models of heart disease are extensively employed. The echocardiographic characterization of contractile function is usually focused on systolic function with fewer studies assessing diastolic function. Furthermore, the applicability of diverse echocardiographic parameters of diastolic function that are commonly used in humans has not been extensively evaluated in different pathophysiological models in mice. METHODS AND RESULTS: We used high resolution echocardiography to evaluate parameters of diastolic function in mouse models of chronic pressure overload (aortic constriction), volume overload (aorto-caval shunt), heart failure with preserved ejection fraction (HFpEF; DOCA-salt hypertension), and acute sarcoplasmic reticulum dysfunction induced by thapsigargin - all known to exhibit diastolic dysfunction. Left atrial area increased in all three chronic models while mitral E/A was difficult to quantify at high heart rates. Isovolumic relaxation time (IVRT) and Doppler E/E' increased significantly and the peak longitudinal strain rate during early filling (peak reverse longitudinal strain rate) decreased significantly after aortic constriction, with the changes being proportional to the magnitude of hypertrophy. In the HFpEF model, reverse longitudinal strain rate decreased significantly but changes in IVRT and E/E' were non-significant, consistent with less severe dysfunction. With volume overload, there was a significant increase in reverse longitudinal strain rate and decrease in IVRT, indicating a restrictive physiology. Acute thapsigargin treatment caused significant prolongation of IVRT and decrease in reverse longitudinal strain rate. CONCLUSION: These results indicate that the combined measurement of left atrial area plus reverse longitudinal strain rate and/or IVRT provide an excellent overall assessment of diastolic function in the diseased mouse heart, allowing distinction between different types of pathophysiology.


Asunto(s)
Diástole/fisiología , Ecocardiografía , Cardiopatías/diagnóstico por imagen , Cardiopatías/fisiopatología , Animales , Cardiomegalia/complicaciones , Cardiomegalia/patología , Cardiomegalia/fisiopatología , Modelos Animales de Enfermedad , Cardiopatías/complicaciones , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/patología , Insuficiencia Cardíaca/fisiopatología , Ratones Endogámicos C57BL , Variaciones Dependientes del Observador , Presión , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/antagonistas & inhibidores , ATPasas Transportadoras de Calcio del Retículo Sarcoplásmico/metabolismo , Volumen Sistólico , Sístole/fisiología , Tapsigargina/farmacología
10.
Echocardiography ; 35(11): 1895-1897, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30220087

RESUMEN

We present the case of a 54-year-old man who had an unusual finding in contrast echocardiography with agitated saline. Partition of the right atrium in two compartments, an opacified and a non-opacified one, was noted. Further assessment with a transesophageal echocardiogram revealed the presence of a membrane in the right atrium, with the final diagnosis being cor triatriatum dexter.


Asunto(s)
Medios de Contraste , Corazón Triatrial/diagnóstico por imagen , Ecocardiografía Transesofágica/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Aumento de la Imagen/métodos , Solución Salina , Diagnóstico Diferencial , Humanos , Masculino , Persona de Mediana Edad
11.
Echocardiography ; 35(1): 132-134, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29226430

RESUMEN

We present a case of a 68-year-old man with calciphylaxis, who was found to have a floating thrombus in the descending aorta on a transesophageal echocardiogram. The use of 3D echocardiography demonstrated nicely the free motion of the thrombus, emerging from an atherosclerotic plaque in the descending aorta. Anticoagulation was started for thromboembolism prevention.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/complicaciones , Enfermedades de la Aorta/diagnóstico por imagen , Calcifilaxia/complicaciones , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen , Anciano , Diagnóstico Diferencial , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Resultado Fatal , Humanos , Masculino
12.
Echocardiography ; 35(5): 747-749, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29509971

RESUMEN

Contrast echocardiography with agitated saline is used to assess mainly the existence of interatrial communication. We report a case of a 26-year-old woman, with a "port-a-cath" central venous line, who had an unusual finding in agitated saline contrast echocardiography. Multimodality imaging revealed occlusion of superior vena cava and a systemic-to-pulmonary venous shunt.


Asunto(s)
Ecocardiografía/métodos , Defectos del Tabique Interatrial/diagnóstico , Venas Pulmonares/diagnóstico por imagen , Cloruro de Sodio/farmacología , Vena Cava Superior/diagnóstico por imagen , Adulto , Femenino , Humanos , Venas Pulmonares/anomalías , Vena Cava Superior/anomalías
13.
Curr Cardiol Rep ; 20(2): 9, 2018 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-29435741

RESUMEN

PURPOSE OF REVIEW: Transcatheter aortic valve replacement (TAVR) is underpinned by an array of imaging techniques designed to not only select an appropriately sized implant but also to identify potential obstacles to procedural success. This review presents currently important aspects of TAVR imaging, describing the salient features of each modality as well as recent developments in the field. RECENT FINDINGS: The latest data on TAVR outcomes reflects the increasing experience of operators and the significant role of pre-procedural imaging. Debate continues as to which modality sizes the aortic annulus most accurately, 3D transoesophageal echocardiography (TEE) or MDCT, as well as to whether the merits of real-time peri-procedural 3D imaging guidance outweigh the possible adverse consequences of general anaesthesia which is requisite for intraprocedural 3D TEE. TAVR is now largely based on pre-acquired roadmaps of the truncal vasculature and intense pre-procedural planning. TEE and Multi-detector computed tomography (MDCT) have been shown to perform similarly in annulus sizing. However, given the complexity of many TAVR patients and the importance of identifying the most suitable pathway to the valve as well as any potentially confounding other structural or functional heart disease, both modalities remain relevant in current TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Diagnóstico por Imagen/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Angiografía Coronaria , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Humanos , Tomografía Computarizada Multidetector , Diseño de Prótesis , Ajuste de Prótesis/métodos
14.
Echocardiography ; 34(11): 1740-1741, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28736811

RESUMEN

We present the case of a 34-year-old female who was admitted to our hospital due to community-acquired pneumonia and had a transthoracic echocardiogram which revealed an aneurysm of the membranous interventricular septum. This was further investigated with a transesophageal echocardiogram which showed in detail the anatomical features of this very rare condition.


Asunto(s)
Ecocardiografía/métodos , Aneurisma Cardíaco/diagnóstico por imagen , Hallazgos Incidentales , Tabique Interventricular/diagnóstico por imagen , Adulto , Ecocardiografía Transesofágica , Femenino , Humanos
15.
Am J Physiol Heart Circ Physiol ; 306(9): H1371-83, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24531814

RESUMEN

The objectives of this study were to assess the feasibility and accuracy of high-frequency speckle tracking echocardiography (STE) in a murine model of myocardial infarction (MI). STE is used clinically to quantify global and regional cardiac function, but its application in mice is challenging because of the small cardiac size and rapid heart rates. A high-frequency micro-ultrasound system with STE (Visualsonics Vevo 2100) was compared against magnetic resonance imaging (MRI) for the assessment of global left ventricular (LV) size and function after murine MI. Animals subjected to coronary ligation (n = 46) or sham ligation (n = 27) were studied 4 wk postoperatively. Regional and global deformation were also assessed. STE-derived LV ejection fraction (EF) and mass correlated well with MRI indexes (r = 0.93, 0.77, respectively; P < 0.001), as did STE-derived mass with postmortem values (r = 0.80, P < 0.001). Higher STE-derived volumes correlated positively with MRI-derived infarct size (P < 0.01). Global strain parameters were significantly reduced after MI (all P < 0.001) and strongly correlated with LV mass and MRI-derived infarct size as promising surrogates for the extent of remodeling and infarction, respectively (both P < 0.05). Regional strain analyses showed that radial strain and strain rate were relatively preserved in anterior basal segments after MI compared with more apical segments (P < 0.001); however, longitudinal strain and strain rate were significantly impaired both basally and distally (P < 0.001). Strain-derived parameters of dyssynchrony were significantly increased in the MI group (P < 0.01). Analysis time for STE was 210 ± 45 s with acceptable inter- and intraobserver variability. In conclusion, high-frequency STE enables quantitative assessment of regional and global function in the remodeling murine LV after MI.


Asunto(s)
Ecocardiografía/métodos , Infarto del Miocardio/diagnóstico por imagen , Función Ventricular Izquierda , Remodelación Ventricular , Animales , Modelos Animales de Enfermedad , Femenino , Ratones , Ratones Endogámicos C57BL , Infarto del Miocardio/fisiopatología
16.
Echo Res Pract ; 10(1): 12, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37528494

RESUMEN

Mitral interventions remain technically challenging owing to the anatomical complexity and heterogeneity of mitral pathologies. As such, multi-disciplinary pre-procedural planning assisted by advanced cardiac imaging is pivotal to successful outcomes. Modern imaging techniques offer accurate 3D renderings of cardiac anatomy; however, users are required to derive a spatial understanding of complex mitral pathologies from a 2D projection thus generating an 'imaging gap' which limits procedural planning. Physical mitral modelling using 3D printing has the potential to bridge this gap and is increasingly being employed in conjunction with other transformative technologies to assess feasibility of intervention, direct prosthesis choice and avoid complications. Such platforms have also shown value in training and patient education. Despite important limitations, the pace of innovation and synergistic integration with other technologies is likely to ensure that 3D printing assumes a central role in the journey towards delivering personalised care for patients undergoing mitral valve interventions.

17.
J Am Soc Echocardiogr ; 36(6): 581-590.e1, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36592875

RESUMEN

BACKGROUND: Left ventricular (LV) circumferential strain has received less attention than longitudinal deformation, which has recently become part of routine clinical practice. Among other reasons, this is because of the lack of established normal values. Accordingly, the aim of this study was to establish normative values for LV circumferential strain and determine sex-, age-, and race-related differences in a large cohort of healthy adults. METHODS: Complete two-dimensional transthoracic echocardiograms were obtained in 1,572 healthy subjects (51% men), enrolled in the World Alliance Societies of Echocardiography Normal Values Study. Subjects were divided into three age groups (<35, 35-55, and >55 years) and stratified by sex and by race. Vendor-independent semiautomated speckle-tracking software was used to determine LV regional circumferential strain and global circumferential strain (GCS) values. Limits of normal for each measurement were defined as 95% of the corresponding sex and age group falling between the 2.5th and 97.5th percentiles. Intergroup differences were analyzed using unpaired t tests. RESULTS: Circumferential strain showed a gradient, with lower magnitude at the mitral valve level, increasing progressively toward the apex. Compared with men, women had statistically higher magnitudes of regional and global strain. Older age was associated with a stepwise increase in GCS despite an unaffected ejection fraction, a decrease in LV volume, and relatively stable global longitudinal strain in men, with a small gradual decrease in women. Asian subjects demonstrated significantly higher GCS magnitudes than whites of both sexes and blacks among women only. In contrast, no significant differences in GCS were found between white and black subjects of either sex. Importantly, despite statistical significance of these differences across sex, age, and race, circumferential strain values were similar in all groups, with variations of the order of magnitude of 1% to 2%. Notably, no differences in GCS were found among brands of imaging equipment. CONCLUSION: This study established normal values of LV regional circumferential strain and GCS and identified sex-, age-, and race-related differences when present.


Asunto(s)
Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Adulto , Masculino , Humanos , Femenino , Persona de Mediana Edad , Valores de Referencia , Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Voluntarios Sanos
18.
J Am Soc Echocardiogr ; 36(5): 533-542.e1, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36584904

RESUMEN

BACKGROUND: Although increased left ventricular (LV) mass is associated with adverse outcomes, measured values vary widely depending on the specific technique used. Moreover, the impact of sex, age, and race on LV mass remains controversial, further limiting the clinical use of this parameter. Accordingly, the authors studied LV mass using a variety of two-dimensional and three-dimensional echocardiographic techniques in a large population of normal subjects encompassing a wide range of ages. METHODS: Transthoracic echocardiograms obtained from 1,854 healthy adult subjects (52% men) enrolled in the World Alliance Societies of Echocardiography (WASE) Normal Values Study, were divided into three age groups (young, 18-35 years; middle aged, 36-55 years; and old, >55 years). LV mass was obtained using five conventional techniques, including linear and two-dimensional methods, as well as direct three-dimensional measurement. All LV mass values were indexed to body surface area, and differences according to sex, age, and race were analyzed for each technique. RESULTS: LV mass values differed significantly among the five techniques. Three-dimensional measurements were considerably smaller than those obtained using the other techniques and were closer to magnetic resonance imaging normal values reported in the literature. For all techniques, LV mass in men was significantly larger than in women, with and without body surface area indexing. These technique- and sex-related differences were larger than measurement variability. In women, age differences in LV mass were more pronounced and depicted significantly larger values in older age groups for all techniques, except three-dimensional echocardiography, which showed essentially no differences. LV mass was overall larger in black subjects than in white or Asian subjects. CONCLUSIONS: Significant differences in LV mass values exist across echocardiographic techniques, which are therefore not interchangeable. Sex-, race-, and age-related differences underscore the need for separate population specific normal values.


Asunto(s)
Ecocardiografía Tridimensional , Ventrículos Cardíacos , Adulto , Masculino , Persona de Mediana Edad , Humanos , Femenino , Anciano , Adolescente , Adulto Joven , Valores de Referencia , Ventrículos Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Izquierda , Ecocardiografía Tridimensional/métodos , Ecocardiografía , Función Ventricular Izquierda
19.
Eur Heart J Cardiovasc Imaging ; 24(4): 415-423, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36331816

RESUMEN

AIMS: Aortic valve area (AVA) used for echocardiographic assessment of aortic stenosis (AS) has been traditionally interpreted independently of sex, age and race. As differences in normal values might impact clinical decision-making, we aimed to establish sex-, age- and race-specific normative values for AVA and Doppler parameters using data from the World Alliance Societies of Echocardiography (WASE) Study. METHODS AND RESULTS: Two-dimensional transthoracic echocardiographic studies were obtained from 1903 healthy adult subjects (48% women). Measurements of the left ventricular outflow tract (LVOT) diameter and Doppler parameters, including AV and LVOT velocity time integrals (VTIs), AV mean pressure gradient, peak velocity, were obtained according to ASE/EACVI guidelines. AVA was calculated using the continuity equation. Compared with men, women had smaller LVOT diameters and AVA values, and higher AV peak velocities and mean gradients (all P < 0.05). LVOT and AV VTI were significantly higher in women (P < 0.05), and both parameters increased with age in both sexes. AVA differences persisted after indexing to body surface area. According to the current diagnostic criteria, 13.5% of women would have been considered to have mild AS and 1.4% moderate AS. LVOT diameter and AVA were lower in older subjects, both men and women, and were lower in Asians, compared with whites and blacks. CONCLUSION: WASE data provide clinically relevant information about significant differences in normal AVA and Doppler parameters according to sex, age, and race. The implementation of this information into clinical practice should involve development of specific normative values for each ethnic group using standardized methodology.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Masculino , Humanos , Femenino , Anciano , Válvula Aórtica/diagnóstico por imagen , Ecocardiografía/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Ultrasonografía Doppler , Ventrículos Cardíacos/diagnóstico por imagen
20.
J Am Soc Echocardiogr ; 36(8): 858-866.e1, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37085129

RESUMEN

BACKGROUND: Normal values for three-dimensional (3D) right ventricular (RV) size and function are not well established, as they originate from small studies that involved predominantly white North American and European populations, did not use RV-focused views, and relied on older 3D RV analysis software. The World Alliance Societies of Echocardiography study was designed to generate reference ranges for normal subjects around the world. The aim of this study was to assess the worldwide capability of 3D imaging of the right ventricle and report size and function measurements, including their dependency on age, sex, and ethnicity. METHODS: Healthy subjects free of cardiac, pulmonary, and renal disease were prospectively enrolled at 19 centers in 15 countries, representing six continents. Three-dimensional wide-angle RV data sets were obtained and analyzed using dedicated RV software (TomTec) to measure end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume, and ejection fraction (EF). Results were categorized by sex, age (18-40, 41-65, and >65 years) and ethnicity. RESULTS: Of the 2,007 subjects with attempted 3D RV acquisitions, 1,051 had adequate image quality for confident measurements. Upper and lower limits for body surface area-indexed EDV, ESV, and EF were 48 and 95 mL/m2, 19 and 43 mL/m2, and 44% and 58%, respectively, for men and 42 and 81 mL/m2, 16 and 36 mL/m2, and 46% and 61%, respectively, for women. Men had significantly larger EDVs, ESVs, and stroke volumes (even after body surface area indexing) and lower EFs than women (P < .05). EDV and ESV did not show any meaningful differences among age groups. Three-dimensional RV volumes were smallest in Asians. CONCLUSIONS: Reliability of 3D RV acquisition is low worldwide, underscoring the importance of future improvements in imaging techniques. Sex and race must be taken into consideration in the assessment of both RV volumes and EF.


Asunto(s)
Ecocardiografía Tridimensional , Ventrículos Cardíacos , Masculino , Humanos , Femenino , Anciano , Ventrículos Cardíacos/diagnóstico por imagen , Valores de Referencia , Reproducibilidad de los Resultados , Volumen Sistólico , Ecocardiografía , Ecocardiografía Tridimensional/métodos , Función Ventricular Derecha
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA