Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 84
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
6.
Radiat Res ; 199(6): 556-570, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37018160

RESUMEN

After large-scale radiation accidents where many individuals are suspected to be exposed to ionizing radiation, biological and physical retrospective dosimetry assays are important tools to aid clinical decision making by categorizing individuals into unexposed/minimally, moderately or highly exposed groups. Quality-controlled inter-laboratory comparisons of simulated accident scenarios are regularly performed in the frame of the European legal association RENEB (Running the European Network of Biological and Physical retrospective Dosimetry) to optimize international networking and emergency readiness in case of large-scale radiation events. In total 33 laboratories from 22 countries around the world participated in the current RENEB inter-laboratory comparison 2021 for the dicentric chromosome assay. Blood was irradiated in vitro with X rays (240 kVp, 13 mA, ∼75 keV, 1 Gy/min) to simulate an acute, homogeneous whole-body exposure. Three blood samples (no. 1: 0 Gy, no. 2: 1.2 Gy, no. 3: 3.5 Gy) were sent to each participant and the task was to culture samples, to prepare slides and to assess radiation doses based on the observed dicentric yields from 50 manually or 150 semi-automatically scored metaphases (triage mode scoring). Approximately two-thirds of the participants applied calibration curves from irradiations with γ rays and about 1/3 from irradiations with X rays with varying energies. The categorization of the samples in clinically relevant groups corresponding to individuals that were unexposed/minimally (0-1 Gy), moderately (1-2 Gy) or highly exposed (>2 Gy) was successfully performed by all participants for sample no. 1 and no. 3 and by ≥74% for sample no. 2. However, while most participants estimated a dose of exactly 0 Gy for the sham-irradiated sample, the precise dose estimates of the samples irradiated with doses >0 Gy were systematically higher than the corresponding reference doses and showed a median deviation of 0.5 Gy (sample no. 2) and 0.95 Gy (sample no. 3) for manual scoring. By converting doses estimated based on γ-ray calibration curves to X-ray doses of a comparable mean photon energy as used in this exercise, the median deviation decreased to 0.27 Gy (sample no. 2) and 0.6 Gy (sample no. 3). The main aim of biological dosimetry in the case of a large-scale event is the categorization of individuals into clinically relevant groups, to aid clinical decision making. This task was successfully performed by all participants for the 0 Gy and 3.5 Gy samples and by 74% (manual scoring) and 80% (semiautomatic scoring) for the 1.2 Gy sample. Due to the accuracy of the dicentric chromosome assay and the high number of participating laboratories, a systematic shift of the dose estimates could be revealed. Differences in radiation quality (X ray vs. γ ray) between the test samples and the applied dose effect curves can partly explain the systematic shift. There might be several additional reasons for the observed bias (e.g., donor effects, transport, experimental conditions or the irradiation setup) and the analysis of these reasons provides great opportunities for future research. The participation of laboratories from countries around the world gave the opportunity to compare the results on an international level.


Asunto(s)
Aberraciones Cromosómicas , Liberación de Radiactividad Peligrosa , Humanos , Estudios Retrospectivos , Radiometría/métodos , Bioensayo/métodos , Cromosomas , Relación Dosis-Respuesta en la Radiación
7.
Epidemiol Infect ; 140(10): 1896-903, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22129521

RESUMEN

This study describes the results of the health programme implemented in the Valencian Community (Spain) to achieve an early diagnosis of Chagas disease in pregnant Latin American women and their newborns. During 2009 and 2010, 1975 women living in the health districts of three university hospitals were enrolled via midwives or at the time of delivery. Diagnosis of disease was performed using two serological tests with different antigens. Congenital infection was diagnosed by parasitological, molecular or serological methods from blood samples obtained at birth or in subsequent controls. The overall seroprevalence of Chagas infection in pregnant women from 16 different endemic countries was 11·4%. Infection was higher in those from countries in the Gran Chaco Region (Bolivia, 34·1%; Paraguay, 7·4%; Argentina, 5·3%). Eight newborn infants from Bolivian mothers had congenital Chagas which represents a vertical transmission rate of 3·7%. In conclusion, this work supports the benefits of offering an early diagnosis to pregnant women and newborns during routine prenatal healthcare.


Asunto(s)
Enfermedad de Chagas/congénito , Enfermedad de Chagas/epidemiología , Transmisión Vertical de Enfermedad Infecciosa , Complicaciones Infecciosas del Embarazo/epidemiología , Trypanosoma cruzi/aislamiento & purificación , Adolescente , Adulto , Anticuerpos Antiprotozoarios/sangre , Estudios Transversales , ADN Protozoario/genética , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Recién Nacido , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Embarazo , Prevalencia , España/epidemiología , Trypanosoma cruzi/genética , Trypanosoma cruzi/inmunología , Adulto Joven
8.
Comput Methods Programs Biomed ; 221: 106909, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35649297

RESUMEN

BACKGROUND AND OBJECTIVE: Auscultation is the first technique applied to the early diagnose of any cardiovascular disease (CVD) in rural areas and poor-resources countries because of its low cost and non-invasiveness. However, it highly depends on the physician's expertise to recognize specific heart sounds heard through the stethoscope. The analysis of phonocardiogram (PCG) signals attempts to segment each cardiac cycle into the four cardiac states (S1, systole, S2 and diastole) in order to develop automatic systems applied to an efficient and reliable detection and classification of heartbeats. In this work, we propose an unsupervised approach, based on time-frequency characteristics shown by cardiac sounds, to detect and classify heartbeats S1 and S2. METHODS: The proposed system consists of a two-stage cascade. The first stage performs a rough heartbeat detection while the second stage refines the previous one, improving the temporal localization and also classifying the heartbeats into types S1 and S2. The first contribution is a novel approach that combines the dissimilarity matrix with the frame-level spectral divergence to locate heartbeats using the repetitiveness shown by the heart sounds and the temporal relationships between the intervals defined by the events S1/S2 and non-S1/S2 (systole and diastole). The second contribution is a verification-correction-classification process based on a sliding window that allows the preservation of the temporal structure of the cardiac cycle in order to be applied in the heart sound classification. The proposed method has been assessed using the open access databases PASCAL, CirCor DigiScope Phonocardiogram and an additional sound mixing procedure considering both Additive White Gaussian Noise (AWGN) and different kinds of clinical ambient noises from a commercial database. RESULTS: The proposed method outperforms the detection and classification performance of other recent state-of-the-art methods. Although our proposal achieves the best average accuracy for PCG signals without cardiac abnormalities, 99.4% in heartbeat detection and 97.2% in heartbeat classification, its worst average accuracy is always above 92% for PCG signals with cardiac abnormalities, signifying an improvement in heartbeat detection/classification above 10% compared to the other state-of-the-art methods evaluated. CONCLUSIONS: The proposed method provides the best detection/classification performance in realistic scenarios where the presence of cardiac anomalies as well as different types of clinical environmental noises are active in the PCG signal. Of note, the promising modelling of the temporal structures of the heart provided by the dissimilarity matrix together with the frame-level spectral divergence, as well as the removal of a significant number of spurious heart events and recovery of missing heart events, both corrected by the proposed verification-correction-classification algorithm, suggest that our proposal is a successful tool to be applied in heart segmentation.


Asunto(s)
Ruidos Cardíacos , Procesamiento de Señales Asistido por Computador , Algoritmos , Corazón , Frecuencia Cardíaca , Fonocardiografía/métodos
9.
Phys Med Biol ; 67(24)2022 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-36384047

RESUMEN

Objective. The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models.Approach. An array of 1 × 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 × 3.1 × 20 mm3separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 × 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B,with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR +RR, with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a22Na point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in thex- andDOI- directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in thex- (monolithic) andDOIdirections.Results. Energy resolution values of 16 ± 1%, 11 ± 1%, 16 ± 1%, 15 ± 1%, and 13 ± 1% were obtained for theS13-ESR + B + RR,S13-AllESR,S14-ESR + B + RR,S14-ESR + RR,andS14-AllESR, respectively. Regarding positioning accuracy, mean average error of 1.1 ± 0.5, 1.3 ± 0.5 and 1.3 ± 0.5 were estimated for thex- direction and 1.7 ± 0.8, 2.0 ± 0.9 and 2.2 ± 1.0 for theDOI- direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model.Significance. Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.


Asunto(s)
Redes Neurales de la Computación , Tomografía de Emisión de Positrones
10.
Artículo en Inglés | MEDLINE | ID: mdl-20981159

RESUMEN

Radioprotection with natural products may be relevant to the mitigation of ionizing radiation-induced damage in mammalian systems; in this sense, propolis extracts have shown effects such as antioxidant, antitumoral, anti-inflammatory, and immunostimulant. We report for the first time a cytogenetic study to evaluate the radioprotective effect, in vitro, of propolis against radiation-induced chromosomal damage. Lymphocytes were cultured with increasing concentrations of ethanol extract of propolis (EEP), including 20, 40, 120, 250, 500, 750, 1000, and 2000 µg mL(-1) and then exposed to 2 Gy γ-rays. A significant and concentration-dependent decrease is observed in the frequency of chromosome aberrations in samples treated with EEP. The protection against the formation of dicentrics was concentration-dependent, with a maximum protection at 120 µg mL(-1) of EEP. The observed frequency of dicentrics is described as negative exponential function, indicating that the maximum protectible fraction of dicentrics is approximately 44%. Free radical scavenging and antioxidant activities are the mechanisms that these substances use to protect cells from ionizing radiation.

11.
Theriogenology ; 173: 48-55, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34332201

RESUMEN

We investigated the effect of the antioxidant lycopene supplemented into the in vitro maturation medium (TCM-199 with 20 ng/mL epidermal growth factor and 50 mg/mL gentamycin) in a heat shock (HS) model to mimic in vivo heat stress conditions. Bovine cumulus-oocyte complexes were supplemented with 0.2 µM lycopene (or not supplemented; control) under HS (40.5 °C) and non-HS (NHS; 38.5 °C) during maturation. After 22 h of maturation, we evaluated the nuclear status of the oocytes, the level of reactive oxygen species (ROS) production, and the respective blastocyst development and quality (via differential staining). Data were fitted in logistic and linear regression models, and the replicates were set as a random effect. The nuclear maturation was higher in NHS (84.0 ± 3.2%; least square mean ± standard error) than HS control (60.4 ± 4.3%; P < 0.001). Remarkably, the nuclear maturation in HS lycopene (71.7 ± 4.1%) was similar to NHS control (P = 0.7). Under HS conditions lycopene reduced ROS production (27.4 ± 4.8; relative fluorescence units (RFU)) in comparison to HS control (33.8 ± 1.8 RFU; P = 0.009). However, the ROS production in NHS lycopene (18.9 ± 2.0 RFU) was similar to NHS control (18.7 ± 1.8 RFU; P = 0.9). The cleavage rate in HS lycopene (76.1 ± 3.3%) was not lower than NHS lycopene (83.3 ± 2.5%; P > 0.1). On the day 8 of embryo development, the blastocyst rate was higher for NHS lycopene (55.2 ± 4.7%) versus NHS control (44.5 ± 4.7%; P = 0.04), but under HS the day 8 blastocyst rate was similar between control (29.9 ± 4.2%) and lycopene (32.3 ± 4.2%; P = 0.9). Lycopene supplementation increased the cell number of the embryos (total cell, trophectoderm, and inner cell mass numbers) under NHS conditions (P > 0.03). The apoptotic cell ratio was lower in lycopene (NHS and HS) versus control (NHS and HS) (P > 0.04). Lycopene has the ability to scavenge oocyte ROS and improved the cleavage rate of embryos under HS conditions. However, this could not be translated to a higher blastocyst development, which remained lower under HS. Results of our study indicate that antioxidant supplementation like lycopene during the maturation of bovine cumulus-oocyte complexes may be routinely used to improve blastocyst rate and quality under standard maturation conditions.


Asunto(s)
Técnicas de Maduración In Vitro de los Oocitos , Oocitos , Animales , Blastocisto , Bovinos , Suplementos Dietéticos , Desarrollo Embrionario , Respuesta al Choque Térmico , Técnicas de Maduración In Vitro de los Oocitos/veterinaria , Licopeno
12.
Phys Med Biol ; 64(19): 195010, 2019 10 04.
Artículo en Inglés | MEDLINE | ID: mdl-31416053

RESUMEN

We propose an ensemble of multilayer feedforward neural networks to estimate the 3D position of photoelectric interactions in monolithic detectors. The ensemble is trained with data generated from optical Monte Carlo simulations only. The originality of our approach is to exploit simulations to obtain reference data, in combination with a variability reduction that the network ensembles offer, thus, removing the need of extensive per-detector calibration measurements. This procedure delivers an ensemble valid for any detector of the same design. We show the capability of the ensemble to solve the 3D positioning problem through testing four different detector designs with Monte Carlo data, measurements from physical detectors and reconstructed images from the MindView scanner. Network ensembles allow the detector to achieve a 2-2.4 mm FWHM, depending on its design, and the associated reconstructed images present improved SNR, CNR and SSIM when compared to those based on the MindView built-in positioning algorithm.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Tomografía de Emisión de Positrones , Algoritmos , Calibración , Simulación por Computador , Humanos , Imagenología Tridimensional , Luz , Modelos Estadísticos , Método de Montecarlo , Óptica y Fotónica , Fantasmas de Imagen
13.
Radiat Res ; 164(5): 612-7, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16238438

RESUMEN

The results of a cytogenetic study carried out in a group of nine radiologists are presented. Chromosome aberrations were detected by fluorescence plus Giemsa staining and fluorescence in situ hybridization. Dose estimates were obtained by extrapolating the yield of dicentrics and translocations to their respective dose-effect curves. In seven individuals, the 95% confidence limits of the doses estimated by dicentrics did not include 0 Gy. The 99 dicentrics observed in 17,626 cells gave a collective estimated dose of 115 mGy (95% confidence limits 73-171). For translocations, five individuals had estimated doses that were clearly higher than the total accumulated recorded dose. The 82 total apparently simple translocations observed in 9722 cells gave a collective estimated dose of 275 mGy (132-496). The mean genomic frequencies (x100 +/- SE) of complete and total apparently simple translocations observed in the group of radiologists (1.91 +/- 0.30 and 2.67 +/- 0.34, respectively) were significantly higher than those observed in a matched control group (0.53 +/- 0.10 and 0.87 +/- 0.13, P < 0.01 in both cases) and in another occupationally exposed matched group (0.79 +/- 0.12 and 1.14 +/-0.14, P < 0.03 and P < 0.01, respectively). The discrepancies observed between the physically recorded doses and the biologically estimated doses indicate that the radiologists did not always wear their dosimeters or that the dosimeters were not always in the radiation field.


Asunto(s)
Aberraciones Cromosómicas , Radiometría , Translocación Genética , Adulto , Femenino , Humanos , Hibridación Fluorescente in Situ , Masculino , Persona de Mediana Edad
14.
Radiat Prot Dosimetry ; 115(1-4): 461-4, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16381767

RESUMEN

Propolis obtained from honeybee hives has been used in folk medicine as an anti-inflammatory, anti-carcinogenic or immunomodulatory agent. In animal studies, the radioprotector effect of propolis has been attributed to its free-radical scavenging properties. The present study was carried out to show the protective properties of propolis extract against DNA damage induced by gamma irradiation. The evaluation of the radioprotective effect of propolis has been carried out by the analysis of chromosome aberration induction after several doses of gamma rays. The results of an analysis in the presence of ethanol extract of propolis (EEP) were compared with the dose-effect calibration curve for gamma-rays by analysis of chromosome aberrations without propolis, a decrease in the radiation-induced chromosome aberrations has been observed to be higher than 50% for all the doses.


Asunto(s)
Aberraciones Cromosómicas/efectos de los fármacos , Aberraciones Cromosómicas/efectos de la radiación , Análisis Citogenético/métodos , Linfocitos/efectos de los fármacos , Linfocitos/efectos de la radiación , Própolis/administración & dosificación , Traumatismos por Radiación/prevención & control , Células Cultivadas , ADN/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Humanos , Dosis de Radiación , Traumatismos por Radiación/sangre , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/genética , Protección Radiológica/métodos , Tolerancia a Radiación/efectos de los fármacos , Protectores contra Radiación/administración & dosificación , Radiometría/métodos , Resultado del Tratamiento
15.
Rev Esp Anestesiol Reanim ; 62(1): 3-9, 2015 Jan.
Artículo en Inglés, Español | MEDLINE | ID: mdl-24746360

RESUMEN

BACKGROUND AND GOAL OF STUDY: Postoperative myocardial infarction is a serious and frequent complication of cardiac surgery. Nonetheless, diagnosis in this context it is occasionally challenging. We sought to evaluate the kinetics and diagnostic accuracy of the new biomarker « heart-type fatty acid-binding protein ¼ (h-FABP) in the early detection of myocardial injury in patients undergoing off-pump coronary artery bypass grafting, compared with classical biomarkers. MATERIALS AND METHODS: A prospective study was conducted on 17 consecutive patients who underwent off-pump coronary artery bypass grafting during a 2 month period. Blood samples were drawn for measurement of myocardial ischemic injury biomarkers (h-FABP, troponin, creatine kinase [CK] and CK-MB), at baseline (T1), immediate post-coronary artery bypass grafting (T2), on ICU admission (T3), and after 4 (T4), 8 (T5), 24 (T6) and 48 h (T7). Perioperative ischemic complications, defined according to electrocardiographic, echocardiographic and hemodynamic criteria, were recorded. RESULTS: Earlier biomarkers peak plasma values occurred at T4 with troponin (2.9 ± 5.2 ng/mL), and at T5 with h-FABP (37.9 ± 55.5 ng/mL). Maximum values of CK and CK-MB occurred later, both in T6 (741 ± 779 and 37 ± 51 U/L, respectively). The optimized cut-off obtained for h-FABP was 19 ng/mL, providing a sensitivity and specificity of 77 and 75%, respectively, for diagnosis of perioperative ischemic injury, with an area under the ROC curve for h-FABP of 0.83 (95% CI 0.6-1.0) vs. 0.63 (95% CI 0.33-0.83) for troponin. This cut-off value for h-FABP is reached on average at T2 (mean value of h-FABP at T2: 18.9 ± 21.5 ng/mL). CONCLUSION: This is the first study evaluating the kinetics of h-FABP biomarker in perioperative off-pump coronary artery bypass grafting, and the cut-off value established could help to extend earlier detection of myocardial ischemia in this context.


Asunto(s)
Puente de Arteria Coronaria Off-Pump/efectos adversos , Proteínas de Unión a Ácidos Grasos/sangre , Isquemia Miocárdica/sangre , Complicaciones Posoperatorias/sangre , Anciano , Arritmias Cardíacas/sangre , Biomarcadores , Gasto Cardíaco Bajo/sangre , Gasto Cardíaco Bajo/diagnóstico por imagen , Gasto Cardíaco Bajo/etiología , Forma MB de la Creatina-Quinasa/sangre , Ecocardiografía , Electrocardiografía , Proteína 3 de Unión a Ácidos Grasos , Femenino , Hemodinámica , Mortalidad Hospitalaria , Humanos , Tiempo de Internación/estadística & datos numéricos , Masculino , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/etiología , Proyectos Piloto , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Factores de Tiempo , Troponina I/sangre
16.
Radiat Prot Dosimetry ; 164(1-2): 42-5, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25205835

RESUMEN

Creating a sustainable network in biological and retrospective dosimetry that involves a large number of experienced laboratories throughout the European Union (EU) will significantly improve the accident and emergency response capabilities in case of a large-scale radiological emergency. A well-organised cooperative action involving EU laboratories will offer the best chance for fast and trustworthy dose assessments that are urgently needed in an emergency situation. To this end, the EC supports the establishment of a European network in biological dosimetry (RENEB). The RENEB project started in January 2012 involving cooperation of 23 organisations from 16 European countries. The purpose of RENEB is to increase the biodosimetry capacities in case of large-scale radiological emergency scenarios. The progress of the project since its inception is presented, comprising the consolidation process of the network with its operational platform, intercomparison exercises, training activities, proceedings in quality assurance and horizon scanning for new methods and partners. Additionally, the benefit of the network for the radiation research community as a whole is addressed.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/organización & administración , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Urgencias Médicas , Europa (Continente) , Humanos , Exposición a la Radiación/prevención & control , Administración de la Seguridad/organización & administración
17.
Cell Prolif ; 27(6): 333-41, 1994 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10465021

RESUMEN

A seasonal variation in the proliferative response to mitogens and in the proportion of splenic lymphocyte subpopulations was found in mice housed in a constant environment. The lymphoproliferative responses to T-cell and B-cell mitogens reached maximum values in autumn and summer. Identification of lymphocyte subpopulations by flow cytometry demonstrated that the proportion of T cytotoxic-suppressor (Tcs) lymphocytes was significantly higher in autumn and summer than in spring and winter. However, the proportion of B lymphocytes was significantly lower in spring than in the other three seasons, whereas the proportions of T and T helper (Th) cells did not show any seasonal variation. On the other hand, we observed a significant correlation between the level of mitogenic responsiveness and the proportion of Tcs cells, but not between the former and the proportions of B, T or Th cells. These data suggest that the seasonal variation in murine lymphoproliferative responses may depend on the cyclic changes in the proportion of Tcs lymphocytes; these changes, in turn, may be predetermined by the inherent internal biological rhythms of the animal.


Asunto(s)
Ambiente , Subgrupos Linfocitarios/citología , Linfocitos/citología , Estaciones del Año , Animales , División Celular/fisiología , Células Cultivadas , Ritmo Circadiano , Concanavalina A/farmacología , Femenino , Técnica del Anticuerpo Fluorescente , Vivienda para Animales , Lipopolisacáridos/farmacología , Masculino , Ratones , Ratones Endogámicos BALB C , Fitohemaglutininas/farmacología , Mitógenos de Phytolacca americana/farmacología , Bazo/citología , Bazo/efectos de los fármacos
18.
Radiat Res ; 162(1): 31-8, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15222779

RESUMEN

The aim of the present study was to evaluate the influence of the exclusion of cells with unstable aberrations in the elaboration of dose-effect curves for translocations and their implications in biological dosimetry of past exposures. To establish dose-effect curves, peripheral blood samples were irradiated with 60Co gamma rays at ten different doses and the yield of translocations analyzed by FISH was considered in all cells and in stable cells (those without dicentrics, acentrics or rings). To discriminate transmissible translocations, the dose- effect curve for total apparently simple translocations in stable cells was chosen as the reference. In stable cells, dose- effect curves for apparently simple translocations without pseudosimple and complex-derived one-way patterns, tAbtBa and total translocations were obtained. None of these curves differed from the reference curve. When all cells were considered, only the curve for total translocations was significantly different from the reference curve. From the results obtained it can be concluded that the use of dose-effect curves for apparently simple translocations in stable cells and in all cells will give similar dose estimates in retrospective biological dosimetry studies. However, the use of dose-effect curves for total translocations in all cells will lead to underestimations of the dose mainly at high doses.


Asunto(s)
Dosis de Radiación , Translocación Genética , Adulto , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Hibridación Fluorescente in Situ , Transferencia Lineal de Energía , Estudios Retrospectivos
19.
Science ; 199(4328): 480, 1978 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-17749996
20.
Clin Biochem ; 25(5): 379-86, 1992 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1490302

RESUMEN

The effects of cyclosporin and prednisone on plasma lipid and lipoprotein levels were studied in 20 allogeneic bone-marrow transplantation patients receiving cyclosporin plus prednisone therapy, and in 14 allogeneic patients treated only with cyclosporin during 100 days. Eighteen autologous bone-marrow patients not requiring cyclosporin were used as a control group. Patients were studied 5 days prior to transplantation, and on days 30, 60, and 100 after transplantation. To determine the reversibility of the changes, lipid parameters were analyzed 30 days after completion of the treatment. Nutritional supplementation, conditioning regimens, and concomitant medications were not significantly different between groups. Furthermore, no significant differences in age, weight, lipid, or lipoprotein levels were found at baseline. Our results indicate that cyclosporin therapy induces a reversible increase of plasma cholesterol, LDL-cholesterol, triglycerides, VLDL-triglycerides, and apolipoprotein B and a decrease of HDL-cholesterol, HDL2-cholesterol, and apolipoprotein A-I. The addition of prednisone to cyclosporin therapy induces a higher increase in plasma cholesterol mainly due to an increase in HDL-cholesterol. Total cholesterol/HDL-cholesterol ratio increased significantly in patients treated only with cyclosporin. No differences were found in this ratio in patients treated with prednisone compared to those submitted to autologous bone-marrow transplantation. Lipid changes observed in this study were reversible 30 days after cessation of cyclosporin treatment.


Asunto(s)
Trasplante de Médula Ósea , Ciclosporina/farmacología , Lipoproteínas/sangre , Adulto , Apolipoproteína A-I/análisis , Apolipoproteínas B/análisis , Colesterol/sangre , HDL-Colesterol/sangre , LDL-Colesterol/sangre , Ciclosporina/administración & dosificación , Femenino , Humanos , Inyecciones Intravenosas , Masculino , Prednisona/farmacología , Triglicéridos/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA