Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Malar J ; 21(1): 122, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413904

RESUMEN

BACKGROUND: Microscopic examination of Giemsa-stained blood films remains the reference standard for malaria parasite detection and quantification, but is undermined by difficulties in ensuring high-quality manual reading and inter-reader reliability. Automated parasite detection and quantification may address this issue. METHODS: A multi-centre, observational study was conducted during 2018 and 2019 at 11 sites to assess the performance of the EasyScan Go, a microscopy device employing machine-learning-based image analysis. Sensitivity, specificity, accuracy of species detection and parasite density estimation were assessed with expert microscopy as the reference. Intra- and inter-device reliability of the device was also evaluated by comparing results from repeat reads on the same and two different devices. This study has been reported in accordance with the Standards for Reporting Diagnostic accuracy studies (STARD) checklist. RESULTS: In total, 2250 Giemsa-stained blood films were prepared and read independently by expert microscopists and the EasyScan Go device. The diagnostic sensitivity of EasyScan Go was 91.1% (95% CI 88.9-92.7), and specificity 75.6% (95% CI 73.1-78.0). With good quality slides sensitivity was similar (89.1%, 95%CI 86.2-91.5), but specificity increased to 85.1% (95%CI 82.6-87.4). Sensitivity increased with parasitaemia rising from 57% at < 200 parasite/µL, to ≥ 90% at > 200-200,000 parasite/µL. Species were identified accurately in 93% of Plasmodium falciparum samples (kappa = 0.76, 95% CI 0.69-0.83), and in 92% of Plasmodium vivax samples (kappa = 0.73, 95% CI 0.66-0.80). Parasite density estimates by the EasyScan Go were within ± 25% of the microscopic reference counts in 23% of slides. CONCLUSIONS: The performance of the EasyScan Go in parasite detection and species identification accuracy fulfil WHO-TDR Research Malaria Microscopy competence level 2 criteria. In terms of parasite quantification and false positive rate, it meets the level 4 WHO-TDR Research Malaria Microscopy criteria. All performance parameters were significantly affected by slide quality. Further software improvement is required to improve sensitivity at low parasitaemia and parasite density estimations. Trial registration ClinicalTrials.gov number NCT03512678.


Asunto(s)
Malaria Falciparum , Malaria , Pruebas Diagnósticas de Rutina/métodos , Humanos , Aprendizaje Automático , Malaria/diagnóstico , Malaria/parasitología , Malaria Falciparum/parasitología , Microscopía/métodos , Parasitemia/diagnóstico , Parasitemia/parasitología , Plasmodium falciparum , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Malar J ; 20(1): 365, 2021 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-34496850

RESUMEN

BACKGROUND: A malaria slide bank (MSB) is a useful asset for any malaria microscopy testing laboratory to have access to. However, it is not feasible for every country to have its own MSB. If countries are able to pool their resources, a regional MSB is a viable solution. This paper describes the methodology, costing and lessons learnt of establishing and maintaining an MSB over a 3-year period, for a Southern Africa Development Community region. METHODS: A national reference laboratory in South Africa was granted funding for setting up the MSB; it possessed experienced staff and suitable resources. Two additional full-time personnel were employed to carry out the activities of this project. Strict protocols for donor/patient blood sample screening, smear preparation, mass staining, quality control and slide validation were followed. Slides from the MSB were used for training and proficiency testing purposes. The initial and recurrent yearly costs to set up and maintain the MSB were calculated. RESULTS: Over 35 months, 154 batches (26,623 slides) were prepared; the majority were Plasmodium falciparum. Ninety-two percent (141/154) of batches passed internal quality control, and 89% (93/104) passed external validation. From these slides, two training slide sets and six proficiency testing slide sets were sent out. The initial year's cost to establish an MSB was calculated at approximately $165,000, and the recurrent year-on-year cost was $130,000. CONCLUSIONS: The key components for maintaining a high-quality MSB are consistent funding, competent staff and adherence to standardized protocols. Travel to malaria-endemic areas for access to non-falciparum malaria species, and dilution of P. falciparum blood to desired parasite densities, are extremely useful to ensure variety. The MSB created here supported multiple laboratories in eight countries, and has the potential to expand.


Asunto(s)
Cooperación Internacional , Laboratorios , Ensayos de Aptitud de Laboratorios/estadística & datos numéricos , Malaria/diagnóstico , Laboratorios/normas , Laboratorios/estadística & datos numéricos , Laboratorios/provisión & distribución , Plasmodium falciparum/aislamiento & purificación , Control de Calidad , Sudáfrica
3.
S Afr J Infect Dis ; 39(1): 588, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38628426

RESUMEN

Human babesiosis data in Africa is scarce. The clinical presentation and parasite morphology mimics falciparum malaria infection. Diagnostic confirmation is informed by adequate history and communication with the laboratory to activate appropriate testing. This case report describes the course of a returning traveller with persisting symptoms that resolved on tailored antimicrobial therapy following prompt collaborative diagnosis. Contribution: Case highlighting overlapping characteristics of Babesia and malaria infection, necessitating close clinical and laboratory correlation to confirm diagnosis.

4.
J Pediatric Infect Dis Soc ; 11(12): 578-581, 2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36041049

RESUMEN

We report the first case of Balamuthia mandrillaris granulomatous amoebic encephalitis definitively acquired in Africa. Our case emphasizes initial nonspecific dermatological features, delays in confirmation of the diagnosis, difficulties accessing recommended medication, and uncertainty about optimal treatment of a disease with a frequently fatal outcome.


Asunto(s)
Amebiasis , Balamuthia mandrillaris , Encefalitis , Encefalitis Infecciosa , Humanos , Pueblo Africano , Amebiasis/diagnóstico , Amebiasis/tratamiento farmacológico , Encéfalo , Encefalitis/diagnóstico , Encefalitis/tratamiento farmacológico , Resultado Fatal , Granuloma , Encefalitis Infecciosa/diagnóstico , Encefalitis Infecciosa/tratamiento farmacológico , Preescolar
5.
Am J Trop Med Hyg ; 106(1): 219-221, 2021 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-34695801

RESUMEN

Cestodes of Bertiella genus are parasites of nonhuman primates. We describe a rare case of human bertiellosis in South Africa: a 3-year-old girl with a 1-year history of rectal proglottid discharge and intermittent abdominal pain. After repeated failure with benzimidazole antihelminthic treatment, praziquantel proved successful.


Asunto(s)
Cestodos/aislamiento & purificación , Infecciones por Cestodos/diagnóstico , Animales , Antihelmínticos/administración & dosificación , Cestodos/clasificación , Infecciones por Cestodos/tratamiento farmacológico , Infecciones por Cestodos/parasitología , Preescolar , Heces/parasitología , Femenino , Humanos , Praziquantel/administración & dosificación , Sudáfrica
6.
PLoS One ; 12(7): e0180589, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28683092

RESUMEN

BACKGROUND: Pneumocystis pneumonia (PCP) is a serious risk for HIV-positive patients. Asymptomatic infection or colonisation with P. jirovecii has been shown to occur frequently. PCR assays frequently identify such cases, due to their high sensitivity. Quantitative real-time PCR (qPCR) gene copy number cut-off values have been suggested to differentiate colonisation and infection; these need to be standardised for routine use. We compared the results of qPCR with an immunofluorescence assay (IFA) to determine a specific cut-off value. METHODS: From March 2005 through June 2009, induced sputum specimens were collected from adult patients who were clinically suspected of having PCP, at the Chris Hani Baragwanath Hospital in Gauteng, South Africa. Laboratory diagnosis of PCP was done by a conventional direct IFA and a qPCR assay. A receiver operating characteristic (ROC) analysis was performed to determine a suitable copy number cut-off value. RESULTS: P. jirovecii was identified in 51% (156/305) and 67% (204/305) of specimens using IFA and qPCR, respectively. The cut-off value for the qPCR that best predicted the IFA results was 78 copies/5 µl (area under ROC curve 0.92). The sensitivity and specificity of qPCR using this cut-off was 94.6% and 89.1%, respectively, compared with the IFA. DISCUSSION: The results of the ROC curve analysis indicate an excellent predictive value of the qPCR using the proposed cut-off. However, the IFA test is an imperfect gold standard and so this cut-off should not be used in isolation; clinical data should also contribute to the interpretation of the qPCR result.


Asunto(s)
Técnica del Anticuerpo Fluorescente Directa/métodos , Pneumocystis carinii/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Adulto , Femenino , Humanos , Masculino , Pneumocystis carinii/genética , Neumonía por Pneumocystis/diagnóstico , Neumonía por Pneumocystis/microbiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA