Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(10): 823-833, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38289867

RESUMEN

BACKGROUND AND AIMS: An electrical storm (ES) is a clinical emergency with a paucity of established treatment options. Despite initial encouraging reports about the safety and effectiveness of percutaneous stellate ganglion block (PSGB), many questions remained unsettled and evidence from a prospective multicentre study was still lacking. For these purposes, the STAR study was designed. METHODS: This is a multicentre observational study enrolling patients suffering from an ES refractory to standard treatment from 1 July 2017 to 30 June 2023. The primary outcome was the reduction of treated arrhythmic events by at least 50% comparing the 12 h following PSGB with the 12 h before the procedure. STAR operators were specifically trained to both the anterior anatomical and the lateral ultrasound-guided approach. RESULTS: A total of 131 patients from 19 centres were enrolled and underwent 184 PSGBs. Patients were mainly male (83.2%) with a median age of 68 (63.8-69.2) years and a depressed left ventricular ejection fraction (25.0 ± 12.3%). The primary outcome was reached in 92% of patients, and the median reduction of arrhythmic episodes between 12 h before and after PSGB was 100% (interquartile range -100% to -92.3%). Arrhythmic episodes requiring treatment were significantly reduced comparing 12 h before the first PSGB with 12 h after the last procedure [six (3-15.8) vs. 0 (0-1), P < .0001] and comparing 1 h before with 1 h after each procedure [2 (0-6) vs. 0 (0-0), P < .001]. One major complication occurred (0.5%). CONCLUSIONS: The findings of this large, prospective, multicentre study provide evidence in favour of the effectiveness and safety of PSGB for the treatment of refractory ES.


Asunto(s)
Taquicardia Ventricular , Anciano , Femenino , Humanos , Masculino , Estudios Prospectivos , Ganglio Estrellado , Volumen Sistólico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Resultado del Tratamiento , Fibrilación Ventricular/etiología , Función Ventricular Izquierda , Persona de Mediana Edad
2.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38693772

RESUMEN

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Asunto(s)
Arritmias Cardíacas , Cardiomiopatías , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Femenino , Masculino , Cardiomiopatías/terapia , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Persona de Mediana Edad , Adulto , Europa (Continente) , Encuestas y Cuestionarios , Volumen Sistólico , Encuestas de Atención de la Salud , Antiarrítmicos/uso terapéutico , Pautas de la Práctica en Medicina/estadística & datos numéricos , Función Ventricular Izquierda , Ablación por Catéter , Cardiólogos
3.
Europace ; 26(1)2023 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-38091971

RESUMEN

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Asunto(s)
Embolia Pulmonar , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/epidemiología , Tromboembolia Venosa/prevención & control , Anticoagulantes/uso terapéutico , Fibrinolíticos/uso terapéutico , Heparina , Embolia Pulmonar/prevención & control , Embolia Pulmonar/tratamiento farmacológico , Aspirina , Encuestas y Cuestionarios
4.
Cardiovasc Ultrasound ; 21(1): 20, 2023 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-37880719

RESUMEN

PURPOSE: Intra-cardiac echocardiography (ICE) has become an important tool for catheter ablation. Adoption of ICE imaging is still limited because of its prohibitively high cost. Our aim was to study the safety and feasibility of ICE catheters reprocessing and its environmental and financial impact. METHODS: This was a single center retrospective analysis of all consecutive electrophysiology procedures in which ICE catheters were used from 2015 to 2022. In total, 1128 patients were studied (70.6% male, mean age was 57.9 ± 13.2 years). The majority of procedures were related to atrial fibrillation ablation (84.6%). RESULTS: For the whole cohort, 57 new ICE catheters were used. Consequently one catheter could be used for 19.8 procedures. New catheters were only used when the image obtained by reused probes was not satisfactory. There were no cases of ICE probe steering mechanism malfunction, no procedure related infections and no allergic reactions that could be attributed to the resterilization process. In total, there was 8.6% of complications not related to ICE imaging. Financially, ICE probe reprocessing resulted with 90% cost reduction (> 2 millions of Euros savings for the studied period) and 95% waste reduction (639.5 kg less, mostly non degradable waste was produced). CONCLUSION: Our data suggests that ICE catheter reprocessing is feasible and safe. It seems that risk of infection is not increased. Significant economic and environmental savings could be achieved by ICE catheters reprocessing. Furthermore, ICE reprocessing could allow more extensive ICE usage resulting in safer procedures with a potential reduction of serious complications.


Asunto(s)
Fibrilación Atrial , Ecocardiografía , Humanos , Masculino , Adulto , Persona de Mediana Edad , Anciano , Femenino , Ecocardiografía/métodos , Estudios Retrospectivos , Estudios de Factibilidad , Catéteres , Electrofisiología , Resultado del Tratamiento
5.
J Electrocardiol ; 78: 21-24, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36731165

RESUMEN

The present case describes a dilated cardiomyopathy associated with both antidromic and orthodromic atrio-ventricular reentrant tachycardias supported by multiple right accessory pathways. Both right accessory pathways were successfully eliminated by catheter ablation and the patient progressively recovered during the follow up. The following etiologies might be involved: 1) primitive dilated cardiomyopathy (or post-inflammatory); 2) septal dyssinchrony due to ventricular pre-excitation; 3) tachycardiomyopathy.


Asunto(s)
Fascículo Atrioventricular Accesorio , Cardiomiopatía Dilatada , Ablación por Catéter , Síndromes de Preexcitación , Taquicardia Ventricular , Síndrome de Wolff-Parkinson-White , Humanos , Síndrome de Wolff-Parkinson-White/complicaciones , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/cirugía , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/cirugía , Electrocardiografía , Síndromes de Preexcitación/complicaciones , Fascículo Atrioventricular Accesorio/cirugía , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos
6.
Europace ; 24(9): 1504-1511, 2022 10 13.
Artículo en Inglés | MEDLINE | ID: mdl-35851797

RESUMEN

The aim of the study was to systematically review evidence on the effectiveness and safety of oral mexiletine administered in monotherapy or in combination with other antiarrhythmic drugs for recurrent ventricular arrhythmia (ventricular tachycardia/ventricular fibrillation, VT/VF) in adult patients with structural heart disease (SHD) and implantable cardioverter defibrillators (ICDs). We systematically searched MEDLINE, Embase, and CENTRAL databases from inception to 27 August 2021 for prospective and retrospective studies investigating mexiletine in the target population. The main outcome was the reduction of ICD therapy. The main safety outcome was the presence of any serious adverse events (SAEs) leading to mexiletine discontinuation. Study quality was assessed using the Cochrane risk of bias tool or the Newcastle-Ottawa scale. Four studies comprising 86 mexiletine recipients were included in the review. We also obtained individual data of 50 patients from two studies. Ischaemic cardiomyopathy (ICM) was present in 86% of patients. The quality of included studies was moderate/low. A narrative review was undertaken as studies varied widely in terms of study population and treatment. Across studies, mexiletine treatment (with or without amiodarone) seemed to consistently reduce the number of ICD therapies especially in a population where catheter ablation (CA) was unsuccessful or contraindicated. In ICM patients deemed eligible for CA, mexiletine seemed to be inferior to CA. Mexiletine was discontinued in 14% of cases, mainly for gastrointestinal or neurological SAE. Mexiletine seems to be an option for the long-term treatment of recurrent VT/VF in adult patients with SHD, especially ICM, and ICD in whom CA was unsuccessful or not suitable.


Asunto(s)
Amiodarona , Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Adulto , Antiarrítmicos/efectos adversos , Desfibriladores Implantables/efectos adversos , Humanos , Mexiletine/efectos adversos , Estudios Prospectivos , Estudios Retrospectivos , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Fibrilación Ventricular
7.
J Electrocardiol ; 75: 36-43, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36274327

RESUMEN

BACKGROUND: A better selection of patients with left bundle branch block (LBBB) might increase the response to cardiac resynchronization therapy (CRT). The aim of the study was to investigate the association between the Strauss criteria, absence of S wave in V5-V6, the Selvester score and response to CRT. METHODS AND RESULTS: The retrospective analysis included all consecutive patients having undergone implantation of biventricular defibrillators in primary prevention between 2018 and 2020. The final analysis included 236 patients (mean age 69.7 ± 9.9; 77.5% of males). The Strauss criteria were significantly associated with CRT response (p < 0.01) with a sensitivity of 71.3% and specificity of 64.1%. The Strauss criteria along with the absence of S wave in V5 and V6 showed a sensitivity of 56.7%, a specificity of 82.6% and a positive predictive value of 90.5%. The Selvester score was significantly and inversely associated with CRT response (OR 0.818, 95% CI 0.75-0.89; p < 0.001). The multivariable model showed that left ventricular ejection fraction (LVEF) and QRS duration (≥140 ms in males and ≥ 130 ms in females) were independently associated with CRT response (respectively OR 0.92, CI 95% 0.86-0.98, p = 0.01 and OR 3.70, CI 95% 1.12-12.21, p = 0.03). CONCLUSIONS: Strauss criteria, especially in association with absence of S wave in V5 and V6, were able to increase specificity and positive predictive value for predicting CRT response. The Selvester score was inversely associated with CRT response. Finally, LVEF and QRS duration were independently associated with echocardiographic response to CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Volumen Sistólico , Estudios Retrospectivos , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Ecocardiografía , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 44(8): 1432-1448, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34096635

RESUMEN

Three-dimensional (3D) reconstruction by means of electroanatomic mapping (EAM) systems, allows for the understanding of the mechanism of focal or re-entrant arrhythmic circuits, which can be identified by means of dynamic (activation and propagation) and static (voltage) color-coded maps. However, besides this conventional use, EAM may offer helpful anatomical and functional information for tissue characterisation in several clinical settings. Today, data regarding electromechanical myocardial viability, scar detection in ischaemic and nonischaemic cardiomyopathy and arrhythmogenic right ventricle dysplasia (ARVC/D) definition are mostly consolidated, while emerging results are becoming available in contexts such as Brugada syndrome and cardiac resynchronisation therapy (CRT) implant procedures. As part of an invasive procedure, EAM has not yet been widely adopted as a stand-alone tool in the diagnostic path. We aim to review the data in the current literature regarding the use of 3D EAM systems beyond the definition of arrhythmia.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Técnicas Electrofisiológicas Cardíacas/métodos , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Síndrome de Brugada/diagnóstico , Dispositivos de Terapia de Resincronización Cardíaca , Cardiomiopatías/diagnóstico , Cicatriz/diagnóstico , Humanos , Imagenología Tridimensional , Miocardio/patología
9.
J Electrocardiol ; 68: 44-45, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34325103

RESUMEN

In modern Medicine, team working has become crucial to guarantee favorable outcomes in most therapeutical procedures. Electrophysiology (EP) represents an exemplary paradigm of it. Herein, the role of the EP staff members and the importance of cooperation before, during and after the procedure is highlighted. Moreover, the strategies and the future challenges for developing a strong and efficient teamwork through a continuous process of improvement (the so-called "Kaizen Methodology") are widely discussed.


Asunto(s)
Electrocardiografía , Electrofisiología , Humanos
10.
Pacing Clin Electrophysiol ; 43(5): 524-526, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32243600

RESUMEN

The present case reports for the first time an unusual presentation of Brugada type 1 pattern occurring in a "bigeminy way" without no drug challenges or any apparent causes in a family member of a proband with type 1 pattern.


Asunto(s)
Síndrome de Brugada/fisiopatología , Síndrome de Brugada/genética , Diagnóstico Diferencial , Electrocardiografía , Humanos , Masculino , Persona de Mediana Edad
11.
J Electrocardiol ; 59: 17-19, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31931467

RESUMEN

Nerium oleander is an evergreen small tree, very used in some countries such as India and in Sri Lanka as a self-medication method. We report a case of a 55 year-old man with intermittent, advanced AV block secondary to oleander intoxication.


Asunto(s)
Bloqueo Atrioventricular , Nerium , Bloqueo Atrioventricular/inducido químicamente , Bloqueo Atrioventricular/diagnóstico , Electrocardiografía , Humanos , India , Masculino , Persona de Mediana Edad , Automedicación
12.
J Electrocardiol ; 60: 60-66, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32272291

RESUMEN

BACKGROUND: QRS axis deviation can occur during myocardial infarction (MI); to date, little is known about the significance of extreme right axis deviation (ERAD) in the frontal plane, i.e. a shift in QRS axis between +180° and +270°, during MI. We sought to investigate the clinical characteristics and outcomes of patients with new-onset ERAD in the absence of complete bundle branch blocks (BBB) in the setting of acute coronary syndromes (ACS). METHODS: A single-center retrospective observational study was conducted, including patients with new-onset ERAD in the absence of complete BBB admitted for ACS to our Cardiac Intensive Care Unit. Clinical, electrocardiographic, echocardiographic, angiographic features at baseline and cardiovascular events during hospitalization and at mid-term follow-up were collected. RESULTS: The study population consisted of 30 consecutive patients (23 men) from January 2014 to September 2018. The most frequent clinical presentation was ST-segment elevation MI (n = 22, 73.4%) and the most frequent electrocardiographic MI location was anterolateral (n = 11, 36.7%). Left anterior descending (LAD) was the most frequent infarct-related artery (n = 21, 70%); 15 patients (50%) had multivessel coronary artery disease. Cardiac arrest due to ventricular fibrillation (VF) at presentation (n = 5, 16.6%), cardiogenic shock during the hospital stay (n = 10, 33.3%), cardiac arrest due to VF after revascularization (n = 6, 20%) and cardiac death (n = 7, 23.3%) were common. CONCLUSION: New-onset ERAD during MI may be related to extensive myocardial ischemia and/or necrosis causing an "electrical escaping" with an extreme dislocation of the QRS axis. In our limited series we found several acute arrhythmic and hemodynamic complications and high mortality.


Asunto(s)
Electrocardiografía , Infarto del Miocardio , Bloqueo de Rama , Angiografía Coronaria , Ecocardiografía , Humanos , Masculino , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Choque Cardiogénico
13.
Indian Pacing Electrophysiol J ; 20(2): 60-63, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31857213

RESUMEN

BACKGROUND: The wearable cardioverter-defibrillator (WCD) has been approved for patients with poor left ventricular ejection fraction (LVEF) who are at risk of sudden arrhythmic death for a limited period but are not candidates for a definitive implantable cardioverter-defibrillator (ICD). The present study sought to retrospectively analyse our single-centre experience. METHODS AND RESULTS: All consecutive WCDs applied between April 2017 and September 2018 in our centre were enrolled. An exercise test was performed in all patients in order to evaluate the absence of false detection of ventricular arrhythmias by the device. A total of 16 patients (57.7 ± 14.8 years old; 75% males) were taken into consideration for the analysis. Mean LVEF was 32 ± 11% at diagnosis and 42 ± 10% at last follow-up (mean, 3.1 ± 1.7 months; median, 3 months). At the end of the "wearing period" 11/16 patients (69%) did not have ICD implant indications and only 5 (31%) underwent ICD implantation. Neither appropriate nor appropriate shocks occurred during the follow up. CONCLUSIONS: The WCD represents a useful tool to bridge a temporarily increased risk for sudden cardiac death. The proportion of patients with an improvement of LVEF> 35% beyond the WCD-application period was considerable.

14.
Europace ; 21(3): 434-439, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30010776

RESUMEN

AIMS: Vascular complications are the most common complications of atrial fibrillation (AF) ablation. Cryoballoon (CB) ablation for AF needs the insertion of a large 15 Fr sheath in the femoral vein. Our aim was to investigate the impact of vascular ultrasound (US) in guiding access and evaluating post-procedural subclinical complications in a large, multi-centre patient cohort that underwent CB ablation. METHODS AND RESULTS: A total cohort of 1435 consecutive patients were subdivided in 870 US -/-, 265 US -/+, and 300 US +/+ patients depending on US performance for: venipuncture guidance/post-procedural evaluation. Major clinical complications (requiring intervention and/or prolonged stay) were assessed. Irrespective of the clinical status, major US events were systematically determined in the subgroups with US evaluation 1 day post-procedure, if evidence of inadvertent artery puncture/cannulation (communication between artery and collection or artery-vein, regardless of the thrombosis state). Major clinical events were encountered in 1.7% (15/870), 1.1% (3/265), and 0% of patients in US -/-, US -/+, and US +/+ group, respectively (P = 0.02 between US -/- and US +/+ group). In the US -/- group, 5/10 (50%) of pseudo-aneurysms were diagnosed during readmission after a mean of 24 ± 11 days post-procedure. No delayed presentation was seen in the US -/+ group. Major US events during the US protocol post-procedure were seen in 3.8% (10/265) vs. 0.3% (1/300) of patients in US -/+ vs. US +/+ group, respectively, P = 0.004. CONCLUSION: US-guided venipuncture was associated with a near-to-zero risk of vascular complications in our patients undergoing CB ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Periférico , Criocirugía , Vena Femoral/diagnóstico por imagen , Ultrasonografía Intervencional , Enfermedades Vasculares/prevención & control , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Bélgica , Cateterismo Periférico/efectos adversos , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Punciones , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/etiología
15.
Pacing Clin Electrophysiol ; 42(11): 1456-1462, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31579929

RESUMEN

BACKGROUND: A left common pulmonary vein (LCPV) accounts as the most frequent pulmonary vein (PV) variation. Our aim was to compare the performance of radiofrequency (RF) versus second-generation cryoballoon (CB-A) ablation in patients with atrial fibrillation (AF) and LCPVs. METHODS: In a total cohort of 716 patients undergoing PV isolation with preprocedural CT-scanning, LCPV+ patients were selected with measurement of PV ostial area and trunk distance. All LCPV+ patients were matched between RF and CB-A group in a 1:1 ratio based on propensity scores, and compared for outcome. RESULTS: Left common pulmonary veins were found in 31% (88/283) RF versus 34% (146/433) CB-A patients, respectively, (P = .44). In the matched population of 83 LCPV+ patients in each group, electrical isolation could be achieved in all left-sided PVs. No significant difference was noted for the rate of AF/left atrial tachyarrhythmia (LAT) recurrence between RF and CB-A group (30% vs 28%, P = .86), with similar AF/LAT-free survival (log rank, P = .71). There were 48 patients with AF/LAT recurrence (29%) during the follow-up. Recurrence rate between paroxysmal versus persistent AF was 27/120 (22.5%) versus 21/46 (46%), P = .004. Cox proportional regression analysis withheld LA volume and persistent AF as independent variables to predict AF/LAT recurrence. No increased hazard for AF/LAT recurrence was observed for patients with a long (>15 mm) vs short (5-15 mm) LCPV trunk (OR 1.14, 95% CI 0.6-2.2, P = .7). CONCLUSIONS: In our study, equal efficacy and outcome was noted in LCPV+ patients between RF and CB-A technology.


Asunto(s)
Variación Anatómica , Fibrilación Atrial/cirugía , Ablación por Catéter , Criocirugía , Venas Pulmonares/anatomía & histología , Anciano , Criocirugía/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía
16.
Ann Noninvasive Electrocardiol ; 24(4): e12627, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30659704

RESUMEN

BACKGROUND: Early repolarization patterns (ERP) have been found to be associated with poor cardiovascular end points. We aimed to evaluate the ERP prevalence among patients with structurally normal hearts undergoing radiofrequency (RF) pulmonary vein isolation (PVI) for paroxysmal atrial fibrillation (AF) ablation and its association with the AF recurrence. METHODS: All consecutive patients who underwent RF-PVI as index procedure for paroxysmal AF in our center were evaluated. EXCLUSION CRITERIA: structural heart disease, ongoing use of Class I/III antiarrhythmics, complete-bundle-branch-block. Lateral (I, aVL, V5 -V6 ), inferior (II, III, aVF), or infero-lateral (both) ERP were defined in baseline ECG as horizontal/downsloping J-point elevation ≥1 mm in two consecutive leads with QRS slurring/notching. Documented episodes of AF lasting ≥30 s were considered recurrence. RESULTS: Of 701 cases, 434 patients (305 males, 58 ± 11 years) were included for analysis. ERP observed in 67 patients (15.4%) (Infero-lateral n = 26, inferior n = 23, lateral n = 18) which were significantly younger, demonstrating longer PR-interval and lower heart rates. At a mean follow-up of 22.1 ± 9.7 months, AF recurrences were found in 107 patients (24.6%). In middle-aged patients (≥40-<60 years; n = 206, 79% male), those with an infero-lateral ERP had higher recurrence compared with the ones without (56.3% vs. 19%; p = 0.002). Infero-lateral ERP was significantly predicting recurrence (HR 2.42, 95% CI 1.21-4.82; p = 0.01). CONCLUSION: Early repolarization patterns was more prevalent in our AF population than in the general population. Infero-lateral ERP in baseline ECG might predict AF recurrence in the follow-up after RF-PVI in middle-aged patients.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Electrocardiografía/métodos , Venas Pulmonares/cirugía , Adulto , Anciano , Fibrilación Atrial/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
17.
J Electrocardiol ; 56: 10-14, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31229677

RESUMEN

BACKGROUND: Sutureless aortic valve replacement surgery (AVR) is a reasonable alternative surgical approach in those patients with aortic stenosis who would benefit from reduced cross clamp time, such as elderly and high-risk patients. We sought to evaluate the incidence of pacemaker (PM) implantation following sutureless AVR and to analyse possible pre-operative electrocardiographic and clinical predictors of PM implantation. METHODS AND RESULTS: Between November 2013 and March 2015, 58 patients (male 43%, age 77.9 ±â€¯4.9 years) having undergone sutureless AVR with a Perceval prosthesis (Sorin Biomedica Cardio Srl, Saluggia, Italy) were taken into consideration for our analysis. During a mean follow up of 13.8 ±â€¯5.0 months (median 13 months), 14 patients (24.1%) underwent pacemaker (PM) implantation following sutureless AVR procedure. Among these patients, 12 (86%) presented III degree atrioventricular (AV) block, 1 (7%) presented II degree AV block, and remaining one (7%) severe symptomatic bradycardia. The comparison of pre-operative characteristics between PM group and no PM group highlighted that QRS duration, EuroSCORE II index and chronic renal dysfunction were significantly associated with the development of AV conduction abnormalities/symptomatic bradycardia requiring PM implantation (respectively, p = 0.01, p = 0.02 and p = 0.03). CONCLUSIONS: The incidence of PM implantation after sutureless AVR was 24.1% in the present study. The EuroSCORE II, QRS duration and renal dysfunction were significantly associated with higher risk of AV conduction abnormalities/symptomatic bradycardia requiring PM placement.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Electrocardiografía , Humanos , Italia , Masculino , Diseño de Prótesis , Resultado del Tratamiento
18.
Indian Pacing Electrophysiol J ; 19(6): 211-215, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31238123

RESUMEN

BACKGROUND: The new version of inner lumen mapping catheter (Achieve Advance™; Medtronic, Minnesota, USA) includes a new solid core which provides improved rotational response, as compared to the current Achieve Mapping Catheter. In the present study, we sought to analyze the rate of visualisation of real-time recordings using this new device comparing it with a large cohort of patients having undergone second generation cryoballoon (CB) ablation using the previous Achieve mapping catheter. METHODS: All patients having undergone CB ablation using the Achieve Advance and the last 150 consecutive patients having undergone CB ablation using the previous Achieve were analysed. Exclusion criteria were presence of an intracavitary thrombus, uncontrolled heart failure, moderate or severe valvular disease and contraindications to general anesthesia. RESULTS: A total of 200 consecutive patients (60.1 ±â€¯9.5 years, 75% males) were evaluated (50 Achieve Advance and 150 old Achieve). Real-time recordings were significantly more prevalent in the "new Achieve Advance" population compared with the "old Achieve" group (73.5% vs 56.8%; p = 0.0001). Real-time recordings could be more frequently visualized in the "Achieve Advance" group in all veins except RIPV (LSPV: 86% vs 71.3%, p = 0.04; LIPV: 84% vs 62.7%, p = 0.005; RSPV: 78% vs 52%, p < 0.0001; RIPV: 46% vs 41.3%, p = 0.3). CONCLUSIONS: The rate of visualisation of real-time recordings is significantly higher using the new Achieve Advance if compared to the previous Achieve mapping catheter in the setting of CB ablation. Real-time recordings can be visualized in approximately 73.5% of veins with this new device.

19.
Indian Pacing Electrophysiol J ; 19(5): 183-188, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30914381

RESUMEN

BACKGROUND: Electro-anatomic 3D mapping systems enable the fluoroscopy (FL) exposure to be reduced. In right-heart supraventricular tachycardia (SVT) procedures, FL could potentially be avoided. Our aim was to discuss some steps focusing on safety. METHODS AND RESULTS: The patient cohort comprised 70 consecutive SVT patients who underwent electrophysiologic (EP) catheterization. FL was routinely avoided in all cases (54.2% males, age 57.2 ±â€¯13.3 years): 51 ablations and 19 EP study procedures. The Carto®3 (Biosense Webster) mapping system was used in 17/70 cases (24.3%), and the EnSite Precision™ (Abbott) system in the remaining 53/70 (75.7%). The mean procedure time was 94.1 ±â€¯33.2 min; no FL was used. No major complications occurred. Acute procedural success was achieved in all 51 patients who underwent ablation. Over 3-month follow-up, arrhythmia recurred in 1 patient. There were no significant differences in procedural times between the two mapping systems, except for the time dedicated to the full geometry creation, which was longer for the EnSite Precision™ system: 10 min (8.5-15 IQR) vs 8 min (5-10 IQR) for the Carto® system (p < 0.001) mainly due to the sub-diaphragmatic navigation. The following procedural steps were considered critical in order to safely avoid FL use: "loop" advancing of catheters, the use of a fixed intracardiac reference, His signal landmark centered maps and the careful acquisition of sub-diaphragmatic extracardiac geometry. CONCLUSIONS: A routine zero X-ray approach by means of electro-anatomic 3D mapping systems is safe and effective in right-atrium procedures. Some ad-hoc discussed procedural steps may enhance safety.

20.
Circulation ; 145(13): 1024-1028, 2022 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-35344408
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA