Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vis Exp ; (163)2020 09 03.
Artículo en Inglés | MEDLINE | ID: mdl-32955490

RESUMEN

The preparation of cetacean, in particular baleen whale, skeletons presents a great challenge due to their high lipid content and uncommon size. Documentation of the skeletal morphology is important to produce accurate and reliable models for both research and educational purposes. In this paper, we used a 10.8-meter long Omura's whale stranded in Hong Kong waters in 2014 as an example for the illustration. This rare and enormous specimen was defleshed, macerated, and sun-dried to yield the skeleton for research and public display. Morphology of each bone was then documented by photogrammetry. The complex contour of the skeleton made automated photoshoot inadequate and 3 manual methods were used on bones of different sizes and shapes. The captured photos were processed to generate three-dimensional (3D) models of 166 individual bones. The skeleton was printed half-size with polylactic acid for display purposes, which was easier to maintain than the actual cetacean bones with high residual fat content. The printed bones reflected most anatomical features of the specimen, including the bowing out rostral region and the caudal condylar facet that articulated with Ce1, yet the foramina on the parieto-squamosal suture, which are diagnostic character of Balaenoptera omurai, and an indented groove on the frontal bone at the posterior end of the lateral edge were not clearly presented. Extra photoshoots or 3D surface scanning should be performed on areas with meticulous details to improve precision of the models. The electronic files of the 3D skeleton were published online to reach a global audience and facilitate scientific collaboration among researchers worldwide.


Asunto(s)
Huesos/anatomía & histología , Modelos Anatómicos , Ballenas/anatomía & histología , Animales , Huesos/diagnóstico por imagen , Femenino , Hong Kong , Fotogrametría , Impresión Tridimensional
2.
J Dent ; 57: 26-31, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27939656

RESUMEN

BACKGROUND: Two-unit cantilevered resin-bonded fixed partial dentures (RBFPDs) have higher retention rates over longer span fixed-fixed RBFPDs. It has been hypothesized that interabutment stresses associated with fixed-fixed designs cause prosthesis debonds therefore for the replacement of molar-sized and longer spans, non-rigid connectors have been used to allow independent movement between two abutment teeth. OBJECTIVES: This preliminary study evaluates the clinical longevity and subjects' satisfaction of three-unit fixed-movable (FM3) RBFPDs provided at a dental teaching hospital. MATERIALS AND METHODS: Subjects who had received FM3 RBFPD(s) in the posterior region were clinically reviewed for complications. History of any debonds and subjects' satisfaction to the prosthesis was recorded. Time-to-debond (retention rate) and time-to-loss (survival rate) of these prostheses were presented in life tables. RESULTS: Ninety-eight prostheses in 84 subjects were examined. Their mean service life was 31.8 months (SD 11.5, range 3-67 months). Twenty-two prostheses had a history of debond, resulting in a retention proportion of 77.6%; seventeen of these were rebonded and still present at the time of review. One prosthesis was lost after extraction of a periodontally-involved abutment tooth, giving a survival proportion of 93.9%. High subject satisfaction and no adverse outcome were reported. CONCLUSION: Three-unit fixed-movable RBFPDs have a shorter success than two-unit cantilevered RBFPDs. However, non-rigid connectors allow the possibility of rebonding giving satisfactory short-term survival rate. Further research is needed to investigate their long-term efficacy. CLINICAL SIGNIFICANCE: Three-unit fixed-movable RBFPDs incorporating non-rigid connectors may be a feasible option for replacement of molar-size pontic in the posterior region.


Asunto(s)
Auditoría Clínica , Fracaso de la Restauración Dental , Dentadura Parcial Fija con Resina Consolidada , Adulto , Anciano , Aleaciones de Cromo , Pilares Dentales , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Diseño de Dentadura , Retención de Dentadura , Dentadura Parcial Fija , Dentadura Parcial Fija con Resina Consolidada/efectos adversos , Dentadura Parcial Fija con Resina Consolidada/clasificación , Dentadura Parcial Fija con Resina Consolidada/estadística & datos numéricos , Femenino , Hong Kong , Humanos , Masculino , Persona de Mediana Edad , Diente Molar , Satisfacción del Paciente , Estudios Retrospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA