Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Digit Imaging ; 25(1): 148-54, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21725620

RESUMEN

It is difficult to detect sentinel lymph nodes (SLNs) around an injection point of radiopharmaceuticals mapped in lymphoscintigrams. The purpose of this study was to develop a computer-aided detection (CAD) scheme for SLNs by a subtraction technique using the symmetrical property in the mapped injection point. Our database consisted of 78 lymphoscintigrams with 86 SLNs. In our CAD scheme, the mapped injection point of radiopharmaceuticals was first segmented from the lymphoscintigram using a gray-level thresholding technique. Lymphoscintigram was then divided into four regions by vertical and horizontal straight lines through the center of the segmented injection point. One of the four divided regions was defined as the target region. The correlation coefficients based on pixel values were calculated between the target region and each of the other three regions. The region with the highest correlation coefficient among three regions was selected as the similar region to the target region. The values of pixels on the target region were subtracted by the values of the corresponding pixels on the similar region. This procedure was repeated until every divided region had been used as target region. SLNs were segmented by applying a gray-level thresholding technique to the subtracted image. With our CAD scheme, sensitivity and the number of false positives were 95.3% (82/86) and 2.51 per image, respectively. Our CAD scheme achieved a high level of detection accuracy, and would have a great potential in assisting physicians to detect SLNs in lymphoscintigrams.


Asunto(s)
Ganglios Linfáticos/diagnóstico por imagen , Linfocintigrafia/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Bases de Datos Factuales , Diagnóstico por Computador/métodos , Femenino , Humanos , Ganglios Linfáticos/patología , Reconocimiento de Normas Patrones Automatizadas , Sensibilidad y Especificidad , Biopsia del Ganglio Linfático Centinela , Técnica de Sustracción
2.
J Digit Imaging ; 25(3): 377-86, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21989574

RESUMEN

In a computer-aided diagnosis (CADx) scheme for evaluating the likelihood of malignancy of clustered microcalcifications on mammograms, it is necessary to segment individual calcifications correctly. The purpose of this study was to develop a computerized segmentation method for individual calcifications with various sizes while maintaining their shapes in the CADx schemes. Our database consisted of 96 magnification mammograms with 96 clustered microcalcifications. In our proposed method, a mammogram image was decomposed into horizontal subimages, vertical subimages, and diagonal subimages for a second difference at scales 1 to 4 by using a filter bank. The enhanced subimages for nodular components (NCs) and the enhanced subimages for both nodular and linear components (NLCs) were obtained from analysis of a Hessian matrix composed of the pixel values in those subimages for the second difference at each scale. At each pixel, eight objective features were given by pixel values in the subimages for NCs at scales 1 to 4 and the subimages for NLCs at scales 1 to 4. An artificial neural network with the eight objective features was employed to enhance calcifications on magnification mammograms. Calcifications were finally segmented by applying a gray-level thresholding technique to the enhanced image for calcifications. With the proposed method, a sensitivity of calcifications within clustered microcalcifications and the number of false positives per image were 96.5% (603/625) and 1.69, respectively. The average shape accuracy for segmented calcifications was also 91.4%. The proposed method with high sensitivity of calcifications while maintaining their shapes would be useful in the CADx schemes.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Diagnóstico por Computador/métodos , Mamografía/métodos , Algoritmos , Inteligencia Artificial , Femenino , Humanos , Redes Neurales de la Computación , Reconocimiento de Normas Patrones Automatizadas , Interpretación de Imagen Radiográfica Asistida por Computador , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA