Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; : e14403, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38952067

RESUMEN

PURPOSE: This study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam-off at specific gantry angles). METHODS: A total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference (DD) and relative value (DD%) were evaluated using the dose-volume histogram (DVH) metrics, planning target volume Dmax, D95%, spinal cord D0.035 cc, and esophagus D2.5 cc. The magnitude of the liver movements was evaluated based on differences of liver size Lave at the isocentric axial plane between the inspiratory and expiratory CT images. RESULTS: The DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean ± $ \pm $ a standard deviation (SD) DD in PTV D95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 ± $\pm$ 0.3 and 0.9 ± $ \pm $ 0.6 Gy, respectively. The spinal cord D0.035 cc for those shows 0.4 ± $ \pm $ 0.2 and 0.7 ± $ \pm $ 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between Lave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D0.035 cc revealed approximately 1 Gy or +4% in DD when Lave was < -4 cm. CONCLUSIONS: Respiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath-hold. Alternatively, beam avoidance effectively mitigates the impact.

2.
Skin Res Technol ; 29(1): e13243, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36404577

RESUMEN

INTRODUCTION: Scalp angiosarcoma is a rare and aggressive cancer. Definitive radiotherapy is a treatment option for localised scalp angiosarcoma patients. Although definitive surgical resection reportedly prolongs overall survival (OS), whether initial local treatment effect affects OS when definitive radiotherapy is administered is unclear. Therefore, this study analysed whether local recurrence within 6 months of irradiation correlates with OS and cancer-specific survival (CSS). Furthermore, how local control affects patients' quality of life was investigated. MATERIALS AND METHODS: Thirty-one localised scalp angiosarcoma patients who had received definitive radiotherapy at our institution between October 2010 and July 2021 were analysed retrospectively. The most commonly used dose fractionation was 70 Gy in 35 fractions (83.9%). Local recurrence within 6 months of radiotherapy and other clinical factors were examined in univariate and subsequent multivariate analyses for correlation with OS and CSS. RESULTS: The median follow-up period was 16 months (range, 6-45 months). Local recurrence was detected in 16 patients (51.6%), 12 of whom had recurrence within 6 months. In multivariate analyses, the presence of local recurrence within 6 months of radiotherapy was significantly associated with OS and CSS (p = 0.003, 0.0001, respectively). Ten of the 16 patients with local recurrence had severe symptoms such as bleeding, pain, difficulty opening the eye and malodour. CONCLUSIONS: The initial local treatment effect was significantly associated with OS and CSS after definitive radiotherapy. Furthermore, local recurrence after radiotherapy resulted in a variety of symptoms, including bleeding and pain, which reduced the patient's quality of life.


Asunto(s)
Hemangiosarcoma , Humanos , Hemangiosarcoma/radioterapia , Hemangiosarcoma/patología , Cuero Cabelludo/patología , Estudios Retrospectivos , Relevancia Clínica , Calidad de Vida , Dolor
3.
J Appl Clin Med Phys ; 24(4): e13865, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36573258

RESUMEN

BACKGROUND: The setup of lung shield (LS) in total body irradiation (TBI) with the computed radiography (CR) system is a time-consuming task and has not been quantitatively evaluated. The TBI mobile imager (TBI-MI) can solve this problem through real-time monitoring. Therefore, this study aimed to perform commissioning and performance evaluation of TBI-MI to promote its use in clinical practice. METHODS: The source-axis distance in TBI treatment, TBI-MI (CNERGY TBI, Cablon Medical B.V.), and the LS position were set to 400, 450, and 358 cm, respectively. The evaluation items were as follows: accuracy of image scaling and measured displacement error of LS, image quality (linearity, signal-to-noise ratio, and modulation transfer function) using an EPID QC phantom, optimal thresholding to detect intra-fractional motion in the alert function, and the scatter radiation dose from TBI-MI. RESULTS: The accuracy of image scaling and the difference in measured displacement of the LS was <4 mm in any displacements and directions. The image quality of TBI imager was slightly inferior to the CR image but was visually acceptable in clinical practice. The signal-to-noise ratio was improved at high dose rate. The optimal thresholding value to detect a 10-mm body displacement was determined to be approximately 5.0%. The maximum fraction of scattering radiation to irradiated dose was 1.7% at patient surface. CONCLUSION: MI-TBI can quantitatively evaluate LS displacement with acceptable image quality. Furthermore, real-time monitoring with alert function to detect intrafraction patient displacement can contribute to safe TBI treatment.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Irradiación Corporal Total , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos
4.
J Appl Clin Med Phys ; 24(5): e13915, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36934441

RESUMEN

PURPOSE: We measure the dose distribution of gated delivery for different target motions and estimate the gating latency in a magnetic resonance-guided radiotherapy (MRgRT) system. METHOD: The dose distribution accuracy of the gated MRgRT system (MRIdian, Viewray) was investigated using an in-house-developed phantom that was compatible with the magnetic field and gating method. This phantom contains a simulated tumor and a radiochromic film (EBT3, Ashland, Inc.). To investigate the effect of the number of beam switching and target velocity on the dose distribution, two types of target motions were applied. One is that the target was periodically moved at a constant velocity of 5 mm/s with different pause times (0, 1, 3, 10, and 20 s) between the motions. During different pause times, different numbers of beams were switched on/off. The other one is that the target was moved at velocities of 3, 5, 8, and 10 mm/s without any pause (i.e., continuous motion). The gated method was applied to these motions at MRIdian, and the dose distributions in each condition were measured using films. To investigate the relation between target motion and dose distribution in the gating method, we compared the results of the gamma analysis of the calculated and measured dose distributions. Moreover, we analytically estimated the gating latencies from the dose distributions measured using films and the gamma analysis results. RESULTS: The gamma pass rate linearly decreased with increasing beam switching and target velocity. The overall gating latencies of beam-hold and beam-on were 0.51 ± 0.17 and 0.35 ± 0.05 s, respectively. CONCLUSIONS: Film measurements highlighted the factors affecting the treatment accuracy of the gated MRgRT system. Our analytical approach, employing gamma analysis on films, can be used to estimate the overall latency of the gated MRgRT system.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Humanos , Movimiento (Física) , Espectroscopía de Resonancia Magnética , Dosificación Radioterapéutica , Fantasmas de Imagen
5.
J Org Chem ; 85(16): 10934-10950, 2020 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-32692554

RESUMEN

An asymmetric dearomatization of indoles bearing α-diazoacetamide functionalities was developed for synthesizing high-value spiro scaffolds. A silver phosphate chemoselectively catalyzed the sterically challenging dearomatization, whereas more typically used metal catalysts for carbene transfer reactions, such as a rhodium complex, were not effective and instead resulted in a Büchner ring expansion or cyclopropanation. Mechanistic studies indicated that the spirocyclization occurred through a silver-assisted asynchronous concerted process and not via a silver-carbene intermediate. Analyses based on natural bond orbital population and a distortion/interaction model indicated that the degree of C-Ag mutual interaction is crucial for achieving a high level of enantiocontrol. In addition, an oxidative disconnection of a C(sp3)-C(sp2) bond in the product provided unconventional access to the corresponding chiral spirooxindole.

6.
BMC Urol ; 20(1): 196, 2020 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-33317509

RESUMEN

BACKGROUND: In definitive radiation therapy for prostate cancer, the SpaceOAR® System, a hydrogel spacer, is widely used to decrease the irradiated dose and toxicity of rectum. On the other hand, periprostatic abscesses formation and rectal perforation are known as rare adverse effects of SpaceOAR. Nevertheless, there is a lack of reports clarifying the association between aggravation of abscesses and radiation therapy, and hyperbaric oxygen therapy (HBOT) is effective for a peri-SpaceOAR abscess and rectal perforation. CASE PRESENTATION: We report a case of a 78-year-old high-risk prostate cancer patient. After SpaceOAR insertion into the correct space, he started to receive external beam radiation therapy (EBRT). He developed a fever, perineal pain and frequent urination after the completion of EBRT, and the magnetic resonance imaging (MRI) revealed a peri-SpaceOAR abscess. Scheduled brachytherapy was postponed, administration of antibiotics and opioid via intravenous drip was commenced, and transperineal drainage was performed. After the alleviation of the abscess, additional EBRT instead of brachytherapy was performed with MRI-guided radiation therapy (MRgRT). On the last day of the MRgRT, perineal pain reoccurred, and MRI and colonoscopy detected the rectal perforation. He received an intravenous antibiotics drip and HBOT, and fully recovered from the rectal perforation. CONCLUSIONS: Our report indicates that EBRT can lead to a severe rectum complication by causing inflammation for patients with a peri-SpaceOAR abscess. Furthermore, HBOT was effective for the peri-SpaceOAR abscess and rectal perforation associated with EBRT.


Asunto(s)
Braquiterapia/efectos adversos , Oxigenoterapia Hiperbárica , Neoplasias de la Próstata/radioterapia , Fístula Rectal/etiología , Fístula Rectal/terapia , Absceso Abdominal/etiología , Absceso Abdominal/terapia , Anciano , Braquiterapia/instrumentación , Humanos , Hidrogeles , Perforación Intestinal/etiología , Perforación Intestinal/terapia , Masculino , Dosificación Radioterapéutica , Enfermedades del Recto/etiología , Enfermedades del Recto/terapia
7.
Invest New Drugs ; 37(5): 1086-1093, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-29855823

RESUMEN

The approval of orphan anticancer drugs in Japan has increased to meet high social demand. Drug lag, namely the approval lag of new drugs, is recognized as a social issue in Japan. We investigated the approval lag and its components, submission lag and review-time lag, between Japan and the United States (US) to reveal whether an approval lag still exists, and to identify potential factors that may contribute to reducing the approval lag. Anticancer drugs approved in Japan between April 2004 and November 2017 were investigated using publicly available information. Results showed that the median approval lag of orphan anticancer drugs in 2016-2017 was 727.0 days (interquartile range, IQR, 310.0-1054.3). The approval lag was significantly correlated with the submission lag (correlation coefficient = 1.00, P < 0.001) but not with the review-time lag (correlation coefficient = -0.16, P = 0.22). The submission lag was significantly longer for orphan anticancer drugs than non-orphan drugs (median, 712.5 days [IQR, 186.0-1448.3] vs. 387.0 days [92.8-1096.0], P = 0.023). External collaboration in drug development was associated with a longer submission lag (coefficient = 762.1, P = 0.017), while breakthrough therapy designation in the US was associated with a shorter submission lag (coefficient = -832.8, P = 0.035). In conclusion, we revealed that an approval lag for orphan anticancer drugs still existed in 2016-2017. A submission lag for orphan anticancer drugs was the main component affecting the approval lag, and was longer than that for non-orphan drugs. External collaboration in drug development may be a potential factor in reducing the submission lag for orphan anticancer drugs.


Asunto(s)
Antineoplásicos/uso terapéutico , Aprobación de Drogas/legislación & jurisprudencia , Aprobación de Drogas/estadística & datos numéricos , Neoplasias/tratamiento farmacológico , Producción de Medicamentos sin Interés Comercial/legislación & jurisprudencia , Ensayos Clínicos Fase III como Asunto , Humanos , Japón , Producción de Medicamentos sin Interés Comercial/estadística & datos numéricos , Factores de Tiempo , Estados Unidos , United States Food and Drug Administration
8.
Invest New Drugs ; 36(4): 702-708, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29667133

RESUMEN

The approval of orphan anticancer drugs has increased, with the number exceeding that of non-orphan drugs in Japan in recent years. Although orphan anticancer drugs may have unique characteristics due to their rarity, these have not been fully characterized. We investigated anticancer drugs approved in Japan between April 2004 and November 2017 to reveal the characteristics of regulatory approval and pivotal studies on orphan anticancer drugs compared to non-orphan drugs. The median regulatory review time and number of patients in pivotal studies on orphan anticancer drugs (281.0 days [interquartile range, 263.3-336.0]; 222.5 patients [66.0-454.3]) were significantly lower than those on non-orphan drugs (353.0 days [277.0-535.5]; 521.0 patients [303.5-814.5], respectively) (P < 0.001). Phase II, non-randomized and non-controlled designs were more frequently used in pivotal studies on orphan anticancer drugs (45.9%, 41.9% and 43.2%) than non-orphan drugs (17.2%, 14.1% and 14.1%, respectively). Response rate was more commonly used as a primary endpoint in pivotal studies on orphan anticancer drugs (48.6%) than non-orphan drugs (17.2%). Indications limited by molecular features, second or later treatment line, and accelerated approval in the United States were associated with the use of response rate in orphan anticancer drug studies. In conclusion, we demonstrated that orphan anticancer drugs in Japan have unique characteristics compared to non-orphan drugs: shorter regulatory review and pivotal studies frequently using phase II, non-randomized, or non-controlled designs and response rate as a primary endpoint, with fewer patients.


Asunto(s)
Antineoplásicos/uso terapéutico , Aprobación de Drogas/legislación & jurisprudencia , Ensayos Clínicos Fase II como Asunto , Humanos , Japón , Proyectos de Investigación , Estados Unidos , United States Food and Drug Administration/legislación & jurisprudencia
9.
Org Biomol Chem ; 16(25): 4675-4682, 2018 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-29888358

RESUMEN

A simple protocol to directly access γ-amino acid derivatives by intermolecular regioselective hydroamination of trichloroethyl alkenyldiazoacetates with carbamate using a silver tetrafluoroborate catalyst is described. Density functional theory (DFT) calculations to analyze the reaction mechanism revealed that multiple attractive interactions occur in a transition state to promote the vinylogous addition of nitrogen nucleophiles.

10.
J Am Chem Soc ; 139(30): 10188-10191, 2017 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-28715179

RESUMEN

We report asymmetric dearomatization of phenols using Ag carbenoids from α-diazoacetamides. The Ag catalyst promoted intramolecular dearomatization of phenols, whereas a Rh or Cu catalyst caused C-H insertion and a Büchner reaction. Studies indicated Ag carbenoids have a carbocation-like character, making their behavior and properties unique. Highly enantioselective transformations using Ag carbenoids have not been reported. We achieved a Ag carbenoid-mediated chemo- and highly enantioselective phenol dearomatization with substrate generality for the first time.

11.
Imaging Sci Dent ; 54(2): 129-137, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38948189

RESUMEN

Purpose: Patients with head and neck cancer (HNC) who undergo dental procedures during radiotherapy (RT) face an increased risk of developing osteoradionecrosis (ORN). Accordingly, new tools must be developed to extract critical information regarding the dose delivered to the teeth and mandible. This article proposes a novel approach for visualizing 3-dimensional planned dose distributions on panoramic reconstruction computed tomography (pCT) images. Materials and Methods: Four patients with HNC who underwent volumetric modulated arc therapy were included. One patient experienced ORN and required the extraction of teeth after RT. In the study approach, the dental arch curve (DAC) was defined using an open-source platform. Subsequently, pCT images and dose distributions were generated based on the new coordinate system. All teeth and mandibles were delineated on both the original CT and pCT images. To evaluate the consistency of dose metrics, the Mann-Whitney U test and Student t-test were employed. Results: A total of 61 teeth and 4 mandibles were evaluated. The correlation coefficient between the 2 methods was 0.999, and no statistically significant difference was observed (P>0.05). This method facilitated a straightforward and intuitive understanding of the delivered dose. In 1 patient, ORN corresponded to the region of the root and the gum receiving a high dosage (approximately 70 Gy). Conclusion: The proposed method particularly benefits dentists involved in the management of patients with HNC. It enables the visualization of a 3-dimensional dose distribution in the teeth and mandible on pCT, enhancing the understanding of the dose delivered during RT.

12.
Sci Rep ; 14(1): 11253, 2024 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755333

RESUMEN

Accelerator-based boron neutron capture therapy (BNCT) systems employing a solid-state lithium target indicated the reduction of neutron flux over the lifetime of a target, and its reduction could represent the neutron flux model. This study proposes a novel compensatory approach for delivering the required neutron fluence and validates its clinical applicability. The proposed approach relies on the neutron flux model and the cumulative sum of real-time measurements of proton charges. The accuracy of delivering the required neutron fluence for BNCT using the proposed approach was examined in five Li targets. With the proposed approach, the required neutron fluence could be delivered within 3.0%, and within 1.0% in most cases. However, those without using the proposed approach exceeded 3.0% in some cases. The proposed approach can consider the neutron flux reduction adequately and decrease the effect of uncertainty in neutron measurements. Therefore, the proposed approach can improve the accuracy of delivering the required fluence for BNCT even if a neutron flux reduction is expected during treatment and over the lifetime of the Li target. Additionally, by adequately revising the approach, it may apply to other type of BNCT systems employing a Li target, furthering research in this direction.


Asunto(s)
Terapia por Captura de Neutrón de Boro , Litio , Neutrones , Terapia por Captura de Neutrón de Boro/métodos , Litio/química , Humanos , Aceleradores de Partículas , Dosificación Radioterapéutica
13.
Med Dosim ; 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38368182

RESUMEN

Previous plan competitions have largely focused on dose metric assessments. However, whether the submitted plans were realistic and reasonable from a quality assurance (QA) perspective remains unclear. This study aimed to investigate the relationship between aperture-based plan complexity metrics (PCM) in volumetric modulated arc therapy (VMAT) competition plans and clinical treatment plans verified through patient-specific QA (PSQA). In addition, the association of PCMs with plan quality was examined. A head and neck (HN) plan competition was held for Japanese institutions from June 2019 to July 2019, in which 210 competition plans were submitted. Dose distribution quality was quantified based on dose-volume histogram (DVH) metrics by calculating the dose distribution plan score (DDPS). Differences in PCMs between the two VMAT treatment plan groups (HN plan competitions held in Japan and clinically accepted HN VMAT plans through PSQA) were investigated. The mean (± standard deviation) DDPS for the 98 HN competition plans was 158.5 ± 20.6 (maximum DDPS: 200). DDPS showed a weak correlation with PCMs with a maximum r of 0.45 for monitor unit (MU); its correlation with some PCMs was "very weak." Significant differences were found in some PCMs between plans with the highest 20% DDPSs and the remaining plans. The clinical VMAT and competition plans revealed similar distributions for some PCMs. Deviations in PCMs for the two groups were comparable, indicating considerable variability among planners regarding planning skills. The plan complexity for HN VMAT competition plans increased for high-quality plans, as shown by the dose distribution. Direct comparison of PCMs between competition plans and clinically accepted plans showed that the submitted HN VMAT competition plans were realistic and reasonable from the QA perspective. This evaluation may provide a set of criteria for evaluating plan quality in plan competitions.

14.
Asian J Urol ; 11(2): 286-293, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38680582

RESUMEN

Objectives: Hydrogel spacer (HS) was developed to reduce rectal toxicities caused by radiotherapy, but has been reported to cause major adverse events. Our institute has attempted to introduce a hyaluronic acid (HA) as an alternative spacer. This study aimed to compare rectal doses and geometric distributions between the HS and HA implantation in prostate cancer. Methods: HS and HA were inserted in 20 and 18 patients undergoing high-dose brachytherapy, respectively. The rectum spacer volumes injected were 10 mL and 22 mL, respectively. In the treatment planning system, 13.5 Gy was administered with common catheter positions. The rectal dose indices were assessed between the spacer groups for dosimetry evaluation. Distances between the prostate and rectum and configurations of the spacers were compared. Results: The mean doses irradiated to 0.1 and 2 mL of the rectum were 10.45 Gy and 6.71 Gy for HS, and 6.73 Gy and 4.90 Gy for HA (p<0.001). The mean minimum distances between the prostate and rectum were 1.23 cm and 1.79 cm for HS and HA, respectively (p<0.05). Geometrical configuration comparisons revealed that HA has a higher ability to expand the space than HS. Conclusion: The rectal dose reduction ability of HA is significantly greater than that of HS, suggesting its potential as a new spacer.

15.
Gynecol Oncol ; 129(3): 522-7, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23480872

RESUMEN

OBJECTIVES: This is a multicenter, collaborative study to accumulate cases of small cell carcinoma of the uterine cervix (SmCC), to clarify its clinical and clinicopathologic features and prognosis, and to obtain findings to establish future individualized treatment. METHODS: At medical centers participating in the Kansai Clinical Oncology Group/Intergroup, patients diagnosed with SmCC between 1997 and 2007 were enrolled. Clinicopathologic features and prognosis were retrospectively evaluated in patients with SmCC diagnosed at a central pathologic review. RESULTS: A total of 71 patients were registered at 25 medical centers in Japan. Of these, 52 patients (73%) were diagnosed with SmCC based on a pathological review. These 52 patients diagnosed with SmCC were analyzed. The median follow-up period was 57 months. The 4-year progression-free survival (PFS) was: IB1, 59%; IB2, 68%; IIB, 13%; and IIIB, 17%. The 4-year overall survival (OS) was: IB1, 63%; IB2, 67%; IIB, 30%; IIIB, 29%; and IVB, 25%. For postoperative adjuvant therapy, postoperative chemotherapy (a platinum drug in all cases) was compared to non-chemotherapy. The 4-year PFS was 65% and 14%, and the 4-year OS was 65% and 29%. PFS was significantly better (p=0.002), and the OS tended to be better (p=0.073) in the group with postoperative chemotherapy. CONCLUSION: Even in patients with early stage SmCC, the prognosis is poor. However, in early stage patients, by adding postoperative chemotherapy, the prognosis may improve. Currently, various treatment protocols are used at each medical center, but in the future, a standardized treatment protocol for SmCC will hopefully be established.


Asunto(s)
Carcinoma de Células Pequeñas/diagnóstico , Carcinoma de Células Pequeñas/terapia , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/terapia , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Pequeñas/patología , Carcinoma de Células Pequeñas/cirugía , Terapia Combinada , Supervivencia sin Enfermedad , Femenino , Humanos , Japón , Persona de Mediana Edad , Estadificación de Neoplasias , Medicina de Precisión , Estudios Retrospectivos , Neoplasias del Cuello Uterino/patología , Neoplasias del Cuello Uterino/cirugía , Adulto Joven
16.
Int J Clin Oncol ; 18(2): 314-20, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22310898

RESUMEN

BACKGROUND: This study was designed to evaluate the efficacy of definitive radiation therapy (RT) for invasive carcinoma of the vagina. METHODS: Twenty-six patients with invasive carcinoma of the vagina who received RT were studied retrospectively. The median age was 68 years. The pathologic subtype of vaginal carcinoma was squamous cell carcinoma in 24 patients, adenosquamous cell carcinoma in one patient, and adenocarcinoma in one patient. The distribution of clinical stage according to the International Federation of Gynecology and Obstetrics staging system was as follows: stage I, seven patients; stage II, 10 patients, stage III, seven patients; and stage IVA, two patients. Twenty patients received external beam radiation therapy (EBRT) combined with high-dose rate intracavitary brachytherapy (HDR-ICBT), and three received EBRT alone. The remaining three patients with stage I disease were given HDR-ICBT alone. The median dose was 50 Gy for EBRT, and 23 Gy for HDR-ICBT. Systemic chemotherapy was administered concurrently with RT to three patients. RESULTS: The median follow-up was 90 months. The initial rate of response to RT was 100%, and complete remission was attained in 21 patients (81%). The 5-year overall survival rate (OS) and the median survival time of the 26 patients were 57% and 97 months, respectively. The 5-year OS for the three patients who received HDR-ICBT alone was 100%. Severe toxicity occurred in three patients-grade 3 rectal hemorrhage in one, grade 3 cystitis in one, and grade 4 cystitis in one. CONCLUSIONS: Our results demonstrated that definitive RT with HDR-ICBT is effective for invasive carcinoma of the vagina, with acceptable toxicity.


Asunto(s)
Braquiterapia/efectos adversos , Carcinoma/radioterapia , Neoplasias Vaginales/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Braquiterapia/métodos , Carcinoma/patología , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Invasividad Neoplásica/patología , Estadificación de Neoplasias , Dosis de Radiación , Resultado del Tratamiento , Neoplasias Vaginales/patología
17.
J Microbiol Methods ; 212: 106804, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37543109

RESUMEN

Streptococcus pneumoniae (pneumococcus) is a pathogenic gram-positive bacterium that causes pneumonia, meningitis, and sepsis. Pneumococcal surface protein A (PspA) induces antibodies that protect against lethal infections by pneumococci. PspA is a choline-binding protein present on the cell surface of almost all pneumococcal strains and is a non-capsular polysaccharide vaccine candidate. For research and development of PspA-based vaccines, an in-vitro test system to measure the activity of functional antibodies capable of killing pneumococci is essential. The opsonophagocytic killing (OPK) assay is used to evaluate the opsonic activity of functional antibodies induced by capsular polysaccharide (CPS)-based vaccines (standard OPK assay). Despite the potential of anti-PspA antibodies to protect against lethal infections in mice, the standard OPK assay fails to evaluate anti-PspA antibodies. Using a pneumococcal surface protein C-deficient strain and extending the incubation time of opsonized bacteria, complement, and HL-60 cells reportedly results in enhanced bactericidal activity (modified OPK assay). We aimed to measure the bactericidal activity of anti-PspA antibodies in intact pneumococcal strains. We optimized the pneumococcal culture method used in the OPK assay to increase the efficiency of anti-PspA antibody-mediated phagocytosis of HL-60 cells. As thick capsules hinder phagocytosis, we attempted to obtain pneumococci with thin capsules through an improved culture method. As pneumococci attached to cells exhibit thin capsules, pneumococci cultured in Todd Hewitt yeast extract (THY) broth were spread on blood agar plates and incubated for 4 h. cpsA mRNA transcript levels in pneumococci cultured on blood agar were lower than those in pneumococci cultured in THY broth. OPK activity against pneumococci expressing PspA of clades 1-5 was reasonably well detected using pneumococci cultured on blood agar in the modified OPK assay. The modified OPK assay for anti-PspA antibody using pneumococci cultured on blood agar represents a useful assay to determine the killing activity of functional anti-PspA antibodies against pneumococci.


Asunto(s)
Infecciones Neumocócicas , Streptococcus pneumoniae , Animales , Ratones , Proteínas de la Membrana , Agar , Cápsulas , Anticuerpos Antibacterianos , Polisacáridos , Proteínas Bacterianas/metabolismo , Vacunas Neumococicas
18.
Nat Commun ; 14(1): 5187, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37626028

RESUMEN

Spintronic devices are based on heterojunctions of two materials with different magnetic and electronic properties. Although an energy barrier is naturally formed even at the interface of metallic heterojunctions, its impact on spin transport has been overlooked. Here, using diffusive spin Hall currents, we provide evidence that the inherent energy barrier governs the spin transport even in metallic systems. We find a sizable field-like torque, much larger than the damping-like counterpart, in Ni81Fe19/Bi0.1Sb0.9 bilayers. This is a distinct signature of barrier-mediated spin-orbit torques, which is consistent with our theory that predicts a strong modification of the spin mixing conductance induced by the energy barrier. Our results suggest that the spin mixing conductance and the corresponding spin-orbit torques are strongly altered by minimizing the work function difference in the heterostructure. These findings provide a new mechanism to control spin transport and spin torque phenomena by interfacial engineering of metallic heterostructures.

19.
J Radiat Res ; 64(1): 186-194, 2023 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-36316958

RESUMEN

This study aimed to clarify the differences in radiotherapy dose characteristics and delivery efficiency between the supine and prone positions in patients with prostate cancer using the CyberKnife. The planning computed tomography (CT) and delineations of the prone position were obtained by rotating the supine CT images with delineations of 180° using image processing software. The optimization parameters for planning target volume (PTV) and organs at risk (OARs) were based on the prone position. The optimization parameters determined for the prone position were applied to the supine position for optimization and dose calculation. The dosimetric characteristics of the PTV and OARs, and delivery efficiency were compared between the two different patient positions. The plans in the prone position resulted in better PTV conformity index (nCI), rectum V90%, V80%, V75%, V50% and bladder V50%. A significant difference was observed in treatment time and depth along the central axis (dCAX) between the two plans. The mean treatment time per fraction and dCAX for the supine and prone positions were 20.9 ± 1.7 min versus 19.8 ± 1.3 min (P = 0.019) and 151.1 ± 33.6 mm versus 233.2 ± 8.8 mm (P < 0.001), respectively. In this study the prone position was found to improve dosimetric characteristics and delivery efficiency compared with the supine position during prostate cancer treatment with the CyberKnife.


Asunto(s)
Neoplasias de la Próstata , Radiocirugia , Radioterapia Conformacional , Radioterapia de Intensidad Modulada , Masculino , Humanos , Próstata , Radioterapia Conformacional/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Posición Supina , Dosificación Radioterapéutica , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Órganos en Riesgo , Posición Prona
20.
Respirol Case Rep ; 11(7): e01179, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37303310

RESUMEN

We present a 41-year-old man with idiopathic interstitial pneumonia and pulmonary hypertension (PH) in the setting of a non-autoimmune background whose clinical presentation masqueraded pulmonary veno-occlusive disease (PVOD). Because of no histological evidence of venous occlusion in his previous lung biopsy, phosphodiesterase type-5 inhibitor was given, resulting in sudden onset of pulmonary edema. At autopsy, there were histological features of interstitial fibrosis with occlusion of the lobular septal veins and venules. Clinical presentations of PH due to interstitial fibrosis with pulmonary venous lesions may simulate those of PVOD and careful diagnostic and therapeutic approaches are required.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA