Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Nanotechnology ; 35(20)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38350118

RESUMEN

In recent years, spatial atomic layer deposition (SALD) has gained significant attention for its remarkable capability to accelerate ALD growth by several orders of magnitude compared to conventional ALD, all while operating at atmospheric pressure. Nevertheless, the persistent challenge of inadvertent contributions from chemical vapor deposition (CVD) in SALD processes continues to impede control over film homogeneity, and properties. This research underscores the often-overlooked influence of diffusion coefficients and important geometric parameters on the close-proximity SALD growth patterns. We introduce comprehensive physical models complemented by finite element method simulations for fluid dynamics to elucidate SALD growth kinetics across diverse scenarios. Our experimental findings, in alignment with theoretical models, reveal distinctive growth rate trends in ZnO and SnO2films as a function of the deposition gap. These trends are ascribed to precursor diffusion effects within the SALD system. Notably, a reduced deposition gap proves advantageous for both diffusive and low-volatility bulky precursors, minimizing CVD contributions while enhancing precursor chemisorption kinetics. However, in cases involving highly diffusive precursors, a deposition gap of less than 100µm becomes imperative, posing technical challenges for large-scale applications. This can be ameliorated by strategically adjusting the separation distance between reactive gas outlets to mitigate CVD contributions, which in turn leads to a longer deposition time. Furthermore, we discuss the consequential impact on material properties and propose a strategy to optimize the injection head to control the ALD/CVD growth mode.

2.
Radiol Case Rep ; 19(8): 3587-3590, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38957651

RESUMEN

Filling defects within the inferior vena cava (IVC) are common findings on computed tomography (CT); nevertheless, a majority of these defects are attributed to artifacts. The documentation pertaining to pseudothrombosis specifically affecting the infrarenal vena cava is notably insufficient in current literature. The aim of this study is to present a case demonstrating a blood-contrast level in the infrarenal vena cava, resembling an intraluminal filling defect.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA