Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Orthop Surg ; 16(1): 23-33, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38304207

RESUMEN

Background: While cementless short stems have become popular in total hip arthroplasty (THA), Metha is a relatively recent development that differs from other short stems in its initial fixation concept of partial collum-sparing metaphyseal anchorage. The purpose of this study was to quantify the contact state between Metha and the femur. Additionally, we investigated the difference in contact points between Meta and Fitmore, which is one of the more popular curved short stems. Methods: We conducted a retrospective review of 42 hips that underwent THA using Metha and 41 hips using Fitmore. Stem-to-femur contact was evaluated by density mapping using a three-dimensional digital template system to quantify the contact condition according to the modified Gruen zone. The criterion for the stem-to-bone contact boundary was defined as a computed tomography value of 543 Hounsfield. Results: Quantitative evaluation of Metha according to the modified Gruen zones showed the ratio of surface area with high cortical contact in each zone. The results were 4.6% ± 5.7% in zone 1, 0.9% ± 2.3% in zone 2, 19.1% ± 12.9% in zone 3, 1.4% ± 3.2% in zone 5, 29.6% ± 16.4% in zone 6, and 25.1% ± 17.7% in zones 7. Evaluation of Fitmore for the same zones was as follows: 1.6% ± 2.4%, 18.5% ± 16.9%, 20.8% ± 17.4%, 12.7% ± 12.8%, 3.7% ± 5.8%, and 13.3% ± 10.3%. Comparing the two groups, the contact area was significantly greater for Metha in zones 1, 6 and 7 and Fitmore in zones 2 and 5 (p < 0.05). Conclusions: It is possible for Metha to achieve metaphyseal anchoring by contacting the cortical bone at the proximal femur, thus avoiding proximal offloading. To the best of our knowledge, no previous studies have quantitatively reported stem-to-cortical bone contact conditions in curved short stems.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Tomografía Computarizada por Rayos X , Fémur/diagnóstico por imagen , Fémur/cirugía , Programas Informáticos , Diseño de Prótesis
2.
Case Rep Orthop ; 2019: 8654194, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31915559

RESUMEN

A 64-year-old woman with a spontaneous fused hip sustained a left femoral neck fracture. It was revealed that her left hip joint had a long-standing spontaneous hip fusion due to end-stage osteoarthritis. Additionally, she sustained an ipsilateral femoral intertrochanteric fracture and underwent osteosynthesis using a dynamic hip screw 8 years ago. The one-stage THA was successfully treated with no major complications and good functional recovery was obtained. The hip range of motion improved remarkably at one year after surgery. The Modified Harris Hip Score improved from an estimated 70 points before fracture to 95 points at final follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA