Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Vet Anaesth Analg ; 40(6): 573-83, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23910627

RESUMEN

OBJECTIVE: To evaluate the influence of different inspired oxygen fractions (FiO2) on pulmonary oxygen exchange and Tei-index of myocardial performance in propofol-anesthetized dogs. STUDY DESIGN: Prospective crossover, randomized, experimental trial. ANIMALS: Eight adult dogs weighing 8.6 ± 1.8 kg. METHODS: The animals were anesthetized on five occasions, receiving either an FiO2 = 1.0 (F100), 0.8 (F80), 0.6 (F60), 0.4 (F40) or 0.21 (F21). Propofol was used for induction (6.45 ± 0.69 mgkg(-1) IV) followed by a continuous rate infusion (CRI, 0.7 mgkg(-1) minute(-1)). The dogs breathed spontaneously. The initial measurements of arterial partial pressures of oxygen (PaO2) and carbon dioxide (PaCO2), arterial hemoglobin saturation (SaO2), heart rate (HR), mean arterial pressure (MAP), cardiac index (CI), stroke index (SI), pre-ejection period (PEP) and left ventricular ejection time (LVET) were performed 30 minutes after beginning the CRI (T0) and then, at 15-minute intervals (T15-T60). From these measurements the following were calculated; alveolar oxygen partial pressure (PAO2), alveolar-arterial oxygen gradient (AaDO2), arterial oxygen partial pressure/inspired oxygen fraction ratio (PaO2/FiO2), arterial-to-alveolar oxygen tension ratio (PaO2/PAO2), respiratory index (RI), oxygen delivery (D·O2), PEP/LVET ratio, isovolumic relaxation time (IVRT) and Tei-index. RESULTS: At T30, PaCO2 in F100 was higher than in F21. The AaDO2 mean in F100 was greater than in other treatments. PaO2/FiO2 in F21 was lower than F100 and F80 at T0 and than in F80 and F60 at T15. At T15, PaO2/PAO2 and RI in F100 were higher than in F80, F60 and F21. At T30, PaO2/PAO2 in F21 was lower than in F100 and F60. At T30, PEP/LVET in F100 was higher than F80, F40 and F21, which was lower than F80 and F40. CONCLUSION: The Tei-index and cardiovascular parameters are not affected by different FiO2. CLINICAL RELEVANCE: An FiO2 of 1.0 and 0.21 impaired respiratory efficiency.


Asunto(s)
Anestésicos Intravenosos , Corazón/fisiología , Propofol , Intercambio Gaseoso Pulmonar/fisiología , Anestesia Intravenosa/métodos , Anestesia Intravenosa/veterinaria , Animales , Perros , Femenino , Frecuencia Cardíaca/fisiología , Masculino , Terapia por Inhalación de Oxígeno/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA