RESUMEN
BACKGROUND/OBJECTIVE: The integration of high-intensity interval training (HIIT) and circuit weight training (CWT) is seamless and practical for meeting recommended exercise guidelines. The purpose of this study was to determine the ideal combination of HIIT and CWT to elicit desired acute cardiorespiratory and metabolic responses in variables such as energy expenditure (EE), oxygen consumption (VO2), heart rate (HR), blood lactate (BLa-), excess post-exercise oxygen consumption (EPOC), rating of perceived exertion (RPE), and enjoyment. METHODS: Fourteen trained males (25.7⯱â¯4.4â¯yr) completed two exercise protocols matched for volume and recovery periods. On one day, participants performed six HIIT bouts prior to three rounds of a nine exercise CWT protocol (HIC). The second day (separated byâ¯≥â¯72â¯h) consisted of three rounds of three mini-circuits (three exercises per circuit) integrated with three HIIT bouts between the first and second and second and third mini-circuits (TRI). VO2, HR, and EE were monitored throughout both protocols. EPOC for a 20-min duration, [BLa-] (five time points), RPE, and enjoyment were measured post-exercise. RESULTS: Energy expenditure was significantly higher during the HIC compared to the TRI protocol (pâ¯=â¯.012), as well as EPOC (pâ¯=â¯.034). [BLa-] was significantly greater immediate-, 5min-, 10min- and 20min-post-exercise following HIC as compared to TRI. Mean values for HIC and TRI were similar (pâ¯>â¯.05) for HR and RPE. CONCLUSION: Performing HIIT prior to CWT elicits a higher metabolic perturbation compared to the TRI protocol. Although a significant EE difference was detected between the two trials, the practical difference (â¼20â¯kcal) between protocols indicates both protocols are similarly effective for caloric expenditure, metabolic and cardiorespiratory response.
RESUMEN
Recent examinations have shown lower maximal oxygen consumption during traditional ramp (RAMP) compared with self-paced (SPV) graded exercise testing (GXT) attributed to differences in cardiac output. The current study examined the differences in hemodynamic and metabolic responses between RAMP and SPV during treadmill exercise. Sixteen recreationally trained men (aged23.7 ± 3.0 years) completed 2 separate treadmill GXT protocols. SPV consisted of five 2-min stages (10 min total) of increasing speed clamped by the Borg RPE6-20 scale. RAMP increased speed by 0.16 km/h every 15 s until volitional exhaustion. All testing was performed at 3% incline. Oxygen consumption was measured via indirect calorimetry; hemodynamic function was measured via thoracic impedance and blood lactate (BLa-) was measured via portable lactate analyzer. Differences between SPV and RAMP protocols were analyzed as group means by using paired-samples t tests (R Core Team 2017). Maximal values for SPV and RAMP were similar (p > 0.05) for oxygen uptake (47.1 ± 3.4 vs. 47.4 ± 3.4 mL·kg-1·min-1), heart rate (198 ± 5 vs. 200 ± 6 beats·min-1), ventilation (158.8 ± 20.7 vs. 159.3 ± 19.0 L·min-1), cardiac output (26.9 ± 5.5 vs. 27.9 ± 4.2 L·min-1), stroke volume (SV) (145.9 ± 29.2 vs. 149.8 ± 25.3 mL·beat-1), arteriovenous oxygen difference (18.5 ± 3.1 vs. 19.7 ± 3.1 mL·dL-1), ventilatory threshold (VT) (78.2 ± 7.2 vs. 79.0% ± 7.6%), and peak BLa- (11.7 ± 2.3 vs. 11.5 ± 2.4 mmol·L-1), respectively. In conclusion, SPV elicits similar maximal hemodynamic responses in comparison to RAMP; however, SV kinetics exhibited unique characteristics based on protocol. These results support SPV as a feasible GXT protocol to identify useful fitness parameters (maximal oxygen uptake, oxygen uptake kinetics, and VT).