RESUMEN
An experimental protocol has been developed for the use of rat tracheal explant to evaluate the effects of inhaled chemicals on the mucociliary function. Rats were exposed for 4 h or 7 days (24 h per day) to different concentrations of toluene diisocyanate (TDI). Each rat trachea was subsequently removed rapidly and placed in a humid chamber maintained at 37 degrees C. Mucociliary function was evaluated by video measurements of the two following parameters: mucociliary beating frequency (MCBF) and number of active (A+), partially active (A +/-) and inactive areas (A-). In control tracheas; all areas were active and the MCBF showed hardly any variation around 15.3 Hz. In rats exposed to ca. 0.27 or 0.54 ppm of TDI for 4 h, tracheas showed a significant decrease in the number of active areas and a significant decrease in the MCBF. The same changes were observed in tracheas from rats exposed to approximately 0.05 and 0.10 ppm of TDI for 7 days. After a 7 days recovery period the number of active areas and the MCBF were similar in exposed and control rats except in the group exposed for 7 days to the highest concentrations; these showed only partial recovery. The results of this study showed that this ex vivo method is useful for detecting mucociliary dysfunction.
Asunto(s)
Gases/toxicidad , Depuración Mucociliar/efectos de los fármacos , Administración por Inhalación , Animales , Cilios/efectos de los fármacos , Masculino , Ratas , Ratas Sprague-Dawley , 2,4-Diisocianato de Tolueno/administración & dosificación , 2,4-Diisocianato de Tolueno/toxicidad , Toxicología/métodos , Tráquea/efectos de los fármacos , Tráquea/ultraestructuraRESUMEN
Bitumen fumes emitted during road paving or roofing contain polycyclic aromatic hydrocarbons (PAHs). Experimental studies have been previously performed to test the carcinogenic potency of bitumen fumes. Some of them have been criticised either on the grounds that the fume condensates were not representative of fumes to which humans are exposed or because the fumes were never characterised in terms of particle size and poorly in terms of composition and concentration in the chambers. For a nose-only inhalation study, we have evaluated the ability of a new fume generation system to deliver stable and reproducible atmospheres of bitumen fumes to an inhalation chamber and investigated the representativity of the fumes generated at a concentration level of 5 mg/m3. The fume generator comprises: (1) an insulated 20 l heated kettle (200 degrees C for bitumen); (2) an insulated inlet pipe with a needle valve to adjust the flow of the test compound from the kettle; (3) a fume generation chamber equipped with a series of interchangeable channels of different width. The fume concentration in the exposure chamber can be controlled by changing the channel width or by restricting the evaporation surface with aluminium foil, and/or by changing the flow rate. Samples of the atmosphere in the chamber were collected and analysed for quantitative determination of total particulate matter (TPM), soluble matter, benzo[a]pyrene (B[a]P) content of the fumes and other PAHs, and evaluation of the particle size distribution. The representativeness of the fumes has been tested by comparison with fumes generated in the Shell small-scale fume rig, which was previously validated against field fumes collected during paving operations. Evaporative losses from the filters during sampling, transport and storage have been also assessed. At 5 mg/m3 TPM, the agreement between laboratories was quite good for the TPM analyses and was good for the soluble matter and B[a]P. Evaporative losses may lead to underestimation of the true exposure level in the inhalation chambers but the use of an XAD-2 cartridge backup is one approach to partially recover losses which occur on the filter. The particle size distributions are somewhat different from those reported for fumes associated with roofing and indoor mastic laying works, in that we found more than 85% of particles to be smaller than 1 micron, compared with 40% particles in the previous analyses. In conclusion, this equipment allows reproducible generation of fumes at the 5 mg/m3 TPM that are fairly representative of those produced in the field with the same bitumen.
Asunto(s)
Hidrocarburos/análisis , Exposición Profesional/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Diseño de Equipo , Humanos , Hidrocarburos/química , Exposición por Inhalación , Reproducibilidad de los ResultadosRESUMEN
During the hot application of bitumen-containing materials, e.g. in road paving or roofing, fumes are emitted that contain traces of polycyclic aromatic compounds (PACs). Although worker's exposure to these fumes is low, it might lead to health problems. For studying DNA adduct formation as a consequence of inhalation of bitumen fumes we developed and validated an inhalation system (a dynamic fume generator plus a nose only inhalation chamber). This paper presents and discusses the analytical results from the different laboratories involved in this study on the fumes sampled in the inhalation chamber during three series of experiments where the animals were exposed to fumes at the 5 mg/m3 and 50 mg/m3 level, coming from bitumen heated at 200 degrees C and, as a positive control, fumes from coal tar, heated to 110 degrees C at the 5 mg/m3 level. The following parameters were controlled: temperatures at different key places in the generator; humidity of the chamber; the bitumen or coal tar flow rate; and Total Particulate Matter (TPM). Analyses were performed for Benzene Soluble Matter (BSM), the EPA polycyclic aromatic hydrocarbon (PAH) mixture and for a number of heteroatom-containing PACs. The data show that the coal tar fumes produced at 110 degrees C were very volatile and that most of the differences in particulate matter found between the laboratories can be attributed to evaporative losses. The bitumen fumes boil 25-50 degrees C higher and contain higher boiling compounds. A comparison is made between the PAC exposure profiles for bitumen experiments aimed at 5 and 50 mg/m3. Although the same molecules are found in both fumes their proportion is dramatically different. This effect is largest with the 2- and 3-ring PACs, the ratio of the concentrations found in the 50 mg/m3 TPM concentration to that in the 5 mg/m3 experiment gradually declines from 5500 for acenaphthene to 500 for pyrene, for the 5-ring PACs this ratio is 20-30. As function of their vapour pressure, the ratios of the concentrations of the hetero PACs follow the same trend as that of the 16 EPA PAHs and are of the same order of magnitude. In conclusion, for the compounds investigated, the equipment delivers a fume atmosphere in a reproducible manner. The 50 mg/m3 bitumen fumes are not representatives of field fumes. The reason for these quantitative differences is unclear and further work would be needed to clarify this. Nevertheless it was felt that these fumes at 50 mg/m3 might be a useful tool for qualitative detection of DNA adducts in an animal exposure study.
Asunto(s)
Hidrocarburos/análisis , Hidrocarburos Policíclicos Aromáticos/análisis , Animales , Aductos de ADN , Relación Dosis-Respuesta a Droga , Diseño de Equipo , Humanos , Hidrocarburos/efectos adversos , Exposición por Inhalación , Exposición Profesional , Hidrocarburos Policíclicos Aromáticos/efectos adversosRESUMEN
Bitumen fumes emitted during road paving and roofing contain polycyclic aromatic compounds (PACs) of potential health concern. Little information is available for an experimental device devoted to inhalation experiments with animals exposed to bitumen fumes, and in all studies the systems were never validated for a range of fume concentrations, which prohibited their use for toxicological concentration-effect studies. Therefore, the purpose of this study was to validate a new experimental device able to generate bitumen fumes at different total particulate matter (TPM) concentrations with a linear correlation between TPM and the concentrations of different PACs, thus allowing toxicological dose-response studies with fumes representative of those in the field. Atmosphere samples collected from an animal exposure chamber allowed the determination of TPM, toluene soluble matter, polycyclic aromatic hydrocarbons (PAHs) and semi-volatiles. The particulate size distributions were determined in order to assess the deposition pattern in the respiratory tract. The temperature of 170 degrees C was chosen by analogy with the upper range of the temperature used during paving operations. The temperature of the air passing over the fume emission area was regulated to 20 degrees C and stirring of the heated bitumen was restricted to 90 r.p.m. The data show that the objective of developing a static fume generation system that reproducibly produces fumes in the inhalation chamber for specified target concentrations (TPM) were successful. The within-day variation coefficients for TPM were between 2.5 and 6.1%. The day-to-day variations for TPM concentration were between 4.1 and 5.8%. The concentrations of the 4-5 ring PAHs and the polycyclic aromatic sulphur heterocycles were proportional to the TPM concentration. The 2 and 3 ring PAH concentrations showed a deviation from proportionality with the TPM, probably due to their re-evaporation during sampling. The mass median aerodynamic diameter of airborne particles varied from 1.4 micro m at a fume concentration of 5 mg/m(3) to 3.2 micro m at 100 mg/m(3). In conclusion, this equipment was suitable for nose-only inhalation studies in the 5-100 mg/m(3) range of TPM. Bitumen fumes were generated with a good reproducibility under well-controlled conditions. Finally, the PAH profiles from atmospheric samples were in good agreement with those measured during road paving.