Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Diabet Med ; : e15384, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38923618

RESUMEN

AIMS: In tackling rising diabetes-related emergencies, the need to understand and address emergency service usage by people with type 1 diabetes is vital. This review aimed to quantify current trends in presentations for type 1 diabetes-related emergencies and identify public health strategies that reduce the frequency of diabetes-related emergencies and improve glycaemic management. METHODS: Medline (OVID), Cochrane and CINAHL were searched for studies published between 2000 and 2023, focusing on people with type 1 diabetes, severe hypoglycaemia and/or diabetic ketoacidosis, and ambulance and/or emergency department usage. There were 1313 papers identified, with 37 publications meeting review criteria. RESULTS: The incidence of type 1 diabetes-related emergencies varied from 2.4 to 14.6% over one year for hypoglycaemic episodes, and between 0.07 and 11.8 events per 100 person-years for hyperglycaemic episodes. Notably, our findings revealed that ongoing diabetes education and the integration of diabetes technology, such as continuous glucose monitoring and insulin pump therapy, significantly reduced the incidence of these emergencies. However, socio-economic disparities posed barriers to accessing these technologies, subsequently shifting the cost to emergency healthcare and highlighting the need for governments to consider subsidising these technologies as part of preventative measures. CONCLUSIONS: Improving access to continuous glucose monitoring and insulin pump therapy, in combination with ongoing diabetes education focusing on symptom recognition and early management, will reduce the incidence of diabetes-related emergencies. Concurrent research assessing emergency healthcare usage patterns during the implementation of such measures is essential to ensure these are cost-effective.

2.
Diabet Med ; 41(3): e15195, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37562414

RESUMEN

AIMS: To examine the psychometric properties of the Diabetes Management Experiences Questionnaire (DME-Q). Adapted from the validated Glucose Monitoring Experiences Questionnaire, the DME-Q captures satisfaction with diabetes management irrespective of treatment modalities. METHODS: The DME-Q was completed by adults with type 1 diabetes as part of a randomized controlled trial comparing hybrid closed loop (HCL) to standard therapy. Most psychometric properties were examined with pre-randomization data (n = 149); responsiveness was examined using baseline and 26-week follow-up data (n = 120). RESULTS: Pre-randomization, participants' mean age was 44 ± 12 years, 52% were women. HbA1c was 61 ± 11 mmol/mol (7.8 ± 1.0%), diabetes duration was 24 ± 12 years and 47% used an insulin pump prior to the trial. A forced three-factor analysis revealed three expected domains, that is, 'Convenience', 'Effectiveness' and 'Intrusiveness', and a forced one-factor solution was also satisfactory. Internal consistency reliability was strong for the three subscales ( α range = 0.74-0.84) and 'Total satisfaction' ( α = 0.85). Convergent validity was demonstrated with moderate correlations between DME-Q 'Total satisfaction' and diabetes distress (PAID: rs = -0.57) and treatment satisfaction (DTSQ; rs = 0.58). Divergent validity was demonstrated with a weak correlation with prospective/retrospective memory (PRMQ: rs = -0.16 and - 0.13 respectively). Responsiveness was demonstrated, as participants randomized to HCL had higher 'Effectiveness' and 'Total satisfaction' scores than those randomized to standard therapy. CONCLUSIONS: The 22-item DME-Q is a brief, acceptable, reliable measure with satisfactory structural and construct validity, which is responsive to intervention. The DME-Q is likely to be useful for evaluation of new pharmaceutical agents and technologies in research and clinical settings.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Satisfacción del Paciente , Psicometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estudios Prospectivos , Glucemia , Encuestas y Cuestionarios
3.
Diabet Med ; 40(4): e15020, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36468784

RESUMEN

AIM: To explore the lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery, an area previously receiving minimal attention. METHODS: Semi-structured interviews were conducted with adults aged 60 years or older with long-duration type 1 diabetes who participated in a randomised, open-label, two-stage crossover trial comparing first-generation closed-loop therapy (MiniMed 670G) versus sensor-augmented pump therapy. Interview recordings were transcribed, thematically analysed and assessed. RESULTS: Twenty-one older adults participated in interviews after using closed-loop therapy. Twenty were functionally independent, without frailty or major cognitive impairment; one was dependent on caregiver assistance, including for diabetes management. Quality of life benefits were identified, including improved sleep and reduced diabetes-related psychological burden, in the context of experiencing improved glucose levels. Gaps between expectations and reality of closed-loop therapy were also experienced, encountering disappointment amongst some participants. The cost was perceived as a barrier to continued closed-loop access post-trial. Usability issues were identified, such as disruptive overnight alarms and sensor inaccuracy. CONCLUSIONS: The lived experience of older adults without frailty or major cognitive impairment using first-generation closed-loop therapy was mainly positive and concordant with glycaemic benefits found in the trial. Older adults' lived experience using automated insulin delivery beyond trial environments requires exploration; moreover, the usability needs of older adults should be considered during future device development.


Asunto(s)
Diabetes Mellitus Tipo 1 , Fragilidad , Humanos , Anciano , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Glucemia
4.
J Sleep Res ; : e14106, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38050705

RESUMEN

Hypoglycaemia during sleep is a common and clinically important issue for people living with insulin-treated diabetes. Continuous glucose monitoring devices can help to identify nocturnal hypoglycaemia and inform treatment strategies. However, sleep is generally inferred, with diabetes researchers and physicians using a fixed-overnight period as a proxy for sleep-wake status when analysing and interpretating continuous glucose monitoring data. No study to date has validated such an approach with established sleep measures. Continuous glucose monitoring and research-grade actigraphy devices were worn and sleep diaries completed for 2 weeks by 28 older adults (mean age 67 years [SD 5]; 17 (59%) women) with type 1 diabetes. Using continuous glucose monitoring data from a total of 356 nights, fixed-overnight (using the recommended period of 00:00 hours-06:00 hours) and objectively-measured sleep periods were compared. The fixed-overnight period approach missed a median 57 min per night (interquartile range: 49-64) of sleep for each participant, including five continuous glucose monitoring-detected hypoglycaemia episodes during objectively-measured sleep. Twenty-seven participants (96%) had at least 1 night with continuous glucose monitoring time-in-range and time-above-range discrepancies both ≥ 10 percentage points, a clinically significant discrepancy. The utility of fixed-overnight time continuous glucose monitoring as a proxy for sleep-awake continuous glucose monitoring is inadequate as it consistently excludes actual sleep time, obscures glycaemic patterns, and misses sensor hypoglycaemia episodes during sleep. The use of validated measures of sleep to aid interpretation of continuous glucose monitoring data is encouraged.

5.
Diabetes Spectr ; 36(2): 127-136, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37193203

RESUMEN

Regular exercise is essential to overall cardiovascular health and well-being in people with type 1 diabetes, but exercise can also lead to increased glycemic disturbances. Automated insulin delivery (AID) technology has been shown to modestly improve glycemic time in range (TIR) in adults with type 1 diabetes and significantly improve TIR in youth with type 1 diabetes. Available AID systems still require some user-initiated changes to the settings and, in some cases, significant pre-planning for exercise. Many exercise recommendations for type 1 diabetes were developed initially for people using multiple daily insulin injections or insulin pump therapy. This article highlights recommendations and practical strategies for using AID around exercise in type 1 diabetes.

6.
Diabet Med ; 39(9): e14907, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35757899

RESUMEN

AIM: Hybrid closed-loop (HCL) therapy improves glycaemic control in adolescents with type 1 diabetes; however, little is known about their lived experience using these systems. The aim of this study was to explore the lived experiences of youth with type 1 diabetes using HCL therapy, and their parents, to provide insight into their lived experiences. METHODS: Adolescents and young adults aged 12-25 years, who used Medtronic MiniMed™ 670G HCL system during a 6-month randomised clinical trial, and their parents, were invited to participate in a semi-structured interview at the end of the study. Open-ended questions were used to explore the lived experiences of families using HCL. The interviews were audio-recorded, transcribed and analysed using thematic analysis to determine the main themes. RESULTS: In all, 17 young people with type 1 diabetes mean ± SD age: 17.5 ± 4.2 years, diabetes duration: 11.0 ± 4.9 years and HbA1c 64 ± 9 mmol/mol (8.0 ± 0.8%) and 10 parents were interviewed. Three themes were identified: (1) 'Developing confidence and trust in the system', (2) 'Reduction in anxiety' and (3) 'Issues with device'. They reported a positive experience using HCL, with improvements in glucose levels and increased independence with diabetes management. However, frustration around the number of alarms and notifications associated with the system were also identified as issues. CONCLUSION: Both youth and parents acknowledged the benefits of this first-generation HCL system in improving glycaemic outcomes and in providing flexibility and independence. These lived experiences provide valuable information in the introduction and provision of targeted education with HCL therapy.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adolescente , Adulto , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Adulto Joven
7.
Diabetes Obes Metab ; 24(6): 1143-1149, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35257468

RESUMEN

AIM: To assess the feasibility of a prototype insulin infusion set (IIS) for extended wear in adults with type 1 diabetes. MATERIALS AND METHODS: The prototype Capillary Biomedical investigational extended-wear IIS (CBX IIS) incorporates a soft, flexible, reinforced kink-resistant angled nylon-derivative cannula with one distal and three proximal ports to optimize insulin delivery. Twenty adult participants with type 1 diabetes established on insulin pump therapy used the CBX IIS for two 7-day test periods while wearing a Dexcom G5 continuous glucose monitor. RESULTS: Participants were able to wear the CBX IIS for an average of 6.6 ± 1.4 days. Eighty-eight percent (36 of 41) of sets were worn for 7 days. No serious adverse events were reported. Five infusion sets failed prematurely because of: unresolvable hyperglycaemia (three); hyperglycaemia with elevated ketones (one); or infection (one). Median time in range (3.9-10.0 mmol/L) was 62% (54-76). Average glucose levels per day of infusion set wear showed a statistically significant increase over time (p < .001). CONCLUSIONS: Our preliminary observations confirm the tolerability of the prototype CBX IIS for extended wear, albeit with a deterioration in glucose control after the third day.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hiperglucemia , Adulto , Glucemia , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Estudios de Factibilidad , Humanos , Hiperglucemia/prevención & control , Hipoglucemiantes/uso terapéutico , Insulina/efectos adversos , Sistemas de Infusión de Insulina/efectos adversos
8.
Diabet Med ; 38(11): e14608, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34043837

RESUMEN

AIMS: Aim of this study is to report severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection, responsible for coronavirus disease 2019 (COVID-19), as a possible cause for type 1 diabetes by providing an illustrative clinical case of a man aged 45 years presenting with antibody-negative diabetic ketoacidosis post-recovery from COVID-19 pneumonia and to explore the potential for SARS-CoV-2 to adhere to human islet cells. METHODS: Explanted human islet cells from three independent solid organ donors were incubated with the SARS-CoV-2 spike protein receptor biding domain (RBD) fused to a green fluorescent protein (GFP) or a control-GFP, with differential adherence established by flow cytometry. RESULTS: Flow cytometry revealed dose-dependent specific binding of RBD-GFP to islet cells when compared to control-GFP. CONCLUSIONS: Although a causal basis remains to be established, our case and in vitro data highlight a potential mechanism by which SARS-CoV-2 infection may result in antibody-negative type 1 diabetes.


Asunto(s)
COVID-19/terapia , Diabetes Mellitus Tipo 1/diagnóstico , Cetoacidosis Diabética/diagnóstico , Islotes Pancreáticos/metabolismo , SARS-CoV-2/metabolismo , Glicoproteína de la Espiga del Coronavirus/metabolismo , COVID-19/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/etiología , Cetoacidosis Diabética/etiología , Cetoacidosis Diabética/terapia , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad
9.
Diabetologia ; 61(9): 1918-1922, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29992370

RESUMEN

AIMS/HYPOTHESIS: This multicentre randomised double-blind placebo-controlled clinical trial assessed the efficacy and safety of a methionine aminopeptidase 2 (MetAP2) inhibitor, beloranib, in individuals with obesity (BMI ≥30 kg/m2) and type 2 diabetes (HbA1c 53-97 mmol/mol [7-11%] and fasting glucose <15.6 mmol/l). METHODS: Participants were randomised (via a centralised interactive web response system) to placebo, 1.2 or 1.8 mg beloranib s.c. twice weekly for 26 weeks. Participants, investigators and the sponsor were blinded to group assignment. The primary endpoint was the change in weight from baseline to week 26. The trial was terminated early when beloranib development was stopped because of an imbalance of venous thromboembolism events in beloranib-treated individuals vs placebo that became evident during late-stage development of the drug. RESULTS: In total, 153 participants were randomised, 51 to placebo, 52 to 1.2 mg beloranib and 50 to 1.8 mg beloranib. In participants who completed week 26, the least squares mean ± SE weight change (baseline 111 kg) was -3.1 ± 1.2% with placebo (n = 22) vs -13.5 ± 1.1% and -12.7 ± 1.3% with 1.2 and 1.8 mg beloranib, respectively (n = 25; n = 19; p < 0.0001). The change in HbA1c (baseline 67 mmol/mol [8.3%]) was -6.6 ± 2.2 mmol/mol (-0.6 ± 0.2%) with placebo vs -21.9 ± 2.2 mmol/mol (-2.0 ± 0.2%) or -21.9 ± 3.3 mmol/mol (-2.0 ± 0.3%) with 1.2 or 1.8 mg beloranib (p < 0.0001), respectively. The most common beloranib adverse events were sleep related. One beloranib-treated participant experienced a non-fatal pulmonary embolism. CONCLUSIONS/INTERPRETATION: MetAP2 inhibitors represent a novel mechanism for producing meaningful weight loss and improvement in HbA1c. TRIAL REGISTRATION: ClinicalTrials.gov NCT02324491 FUNDING: The study was funded by Zafgen, Inc.


Asunto(s)
Aminopeptidasas/antagonistas & inhibidores , Cinamatos/uso terapéutico , Ciclohexanos/uso terapéutico , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Diabetes Mellitus Tipo 2/metabolismo , Compuestos Epoxi/uso terapéutico , Metaloendopeptidasas/antagonistas & inhibidores , Sesquiterpenos/uso terapéutico , Adolescente , Adulto , Anciano , Aminopeptidasas/metabolismo , Fármacos Antiobesidad/uso terapéutico , Glucemia/efectos de los fármacos , Peso Corporal/efectos de los fármacos , Método Doble Ciego , Femenino , Glucosa/metabolismo , Hemoglobina Glucada/metabolismo , Glicoproteínas , Humanos , Hipoglucemiantes/uso terapéutico , Masculino , Metaloendopeptidasas/metabolismo , Metionil Aminopeptidasas , Persona de Mediana Edad , Obesidad/tratamiento farmacológico , Obesidad/metabolismo , Pérdida de Peso/efectos de los fármacos , Adulto Joven
10.
Intern Med J ; 48(2): 201-204, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29415350

RESUMEN

We documented temporal changes in the use of lipid-lowering medications and achievement of cholesterol targets in an Australian diabetes clinic. The number of patients using lipid-lowering therapy for primary or secondary cardiovascular prevention increased from 6 to 69% between 1993-1995 and 2014-2016, which corresponded to a decrease in low-density lipoprotein cholesterol levels from 3.7 to 2.4 mmol/L (P < 0.01).


Asunto(s)
Anticolesterolemiantes/uso terapéutico , Enfermedades Cardiovasculares/prevención & control , LDL-Colesterol/efectos de los fármacos , Diabetes Mellitus/tratamiento farmacológico , Hipercolesterolemia/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Anticolesterolemiantes/farmacología , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/epidemiología , LDL-Colesterol/sangre , Diabetes Mellitus/sangre , Diabetes Mellitus/epidemiología , Femenino , Humanos , Hipercolesterolemia/sangre , Hipercolesterolemia/epidemiología , Masculino , Persona de Mediana Edad , Prevención Primaria/métodos , Prevención Secundaria/métodos , Victoria/epidemiología
11.
Intern Med J ; 48(9): 1080-1086, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29573166

RESUMEN

BACKGROUND: In people with type 1 diabetes (T1D), nocturnal hypoglycaemia (NH) can be slept through and can cause seizures, arrhythmias and death. Hypoglycaemia avoidance can induce hyperglycaemia and ketosis. Patient behaviour impacts clinical outcomes and may be changed by education. AIM: To develop and utilise a survey to evaluate patient self-management of overnight glycaemia in adults with T1D. METHODS: Adults with T1D attending two Australian tertiary referral diabetes clinics completed a survey about their diabetes self-management and glycaemic control, including responses to hypothetical pre-bed blood glucose (BG) levels (4-20 mmol/L). Statistical analyses included t-tests, Chi square tests and ANOVA with significance considered at P < 0.05. RESULTS: There were 205 participants (103 females), with a mean (SD) age of 41 (17) years, T1D duration of 20 (16) years, HbA1c of 7.8(1.4)%, (61.3(8.2) mmol/mol), 38% on insulin pump therapy (CSII) and 36% with impaired hypoglycaemia awareness (IHA). Mean (SD) number of BG tests/day was 5.4 (2.7). Patients set higher BG target levels at bedtime and overnight: 7.5(1.4) and 7.1(1.3) mmol/L, respectively, compared to daytime (6.9(1.0); P < 0.0001 and P = 0.002 respectively). Only 36% of participants reported treating nocturnal hypoglycaemia (NH) with the recommended refined, then complex, carbohydrate. Only 28% of patients made safe choices in all bedtime BG scenarios, with higher rates for CSII users, P = 0.0005. Further education was desired by 32% of respondents, with higher rates in those with (44%) versus without IHA (25%), P = 0.006. CONCLUSIONS: Many adults with T1D have suboptimal knowledge and behaviour regarding overnight BG self-management. A survey, piloted herein, may facilitate the identification of patients who could benefit from further education.


Asunto(s)
Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Conocimientos, Actitudes y Práctica en Salud , Hipoglucemia/prevención & control , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Adulto , Australia/epidemiología , Glucemia/análisis , Femenino , Hemoglobina Glucada/análisis , Humanos , Hipoglucemia/sangre , Sistemas de Infusión de Insulina , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Autoinforme , Automanejo
12.
Aust J Prim Health ; 23(1): 23-30, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27465014

RESUMEN

The aim was to examine predictors of duration of inpatient hospital stay in people with diabetes mellitus to assist implementation of strategies to reduce hospital stay. This audit prospectively studied patients with diabetes mellitus admitted to a medical unit of an Australian community public hospital. Other outcome measures included glucose treatment optimisation and access to GP and diabetes-specific healthcare professionals. Comparison was made to patients without diabetes mellitus who were admitted concomitantly. Diabetes patients represented 26% of admissions over a 2-month period. In total, 73% had seen a GP within the prior 6 months. Patients with diabetes mellitus (n=79) had a median age of 69 years; 53% were male and median HbA1c was 65mmolmol-1 (8.1%). Diabetes mellitus was associated with a longer inpatient stay (P=0.03), particularly among patients admitted with vascular disease. Age >65 years and seeing <3 members of the community-based diabetes mellitus multidisciplinary team (MDT) in the 2-years pre-admission were independently associated with a longer stay (P=0.02). In total, 10% were referred to an endocrinologist on discharge. Involvement of more of the diabetes-specific MDT, with a skilled GP, in primary care is recommended as it may shorten inpatient hospital stay, improve glycaemia and reduce demand for limited specialist endocrinologists.


Asunto(s)
Diabetes Mellitus , Hospitales Públicos , Tiempo de Internación , Australia , Femenino , Hospitalización , Hospitales Públicos/estadística & datos numéricos , Humanos , Masculino , Atención Primaria de Salud
13.
Diabetologia ; 59(8): 1636-44, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27168135

RESUMEN

AIMS/HYPOTHESIS: The aim of this study was to investigate the effects of exercise, vs rest, on circulating insulin and glucose, following pre-exercise insulin pump basal rate reduction. METHODS: This was an open-label, two-stage randomised crossover study of 14 adults (seven women, seven men) with type 1 diabetes established on insulin pump therapy. In each stage, participants fasted and insulin delivery was halved following a single insulin basal rate overnight. Exercise (30 min moderate-intensity stationary bicycle exercise, starting 60 min post-basal reduction) and rest stages were undertaken in random order at a university hospital. Randomisation was computer-generated, and allocation concealed via sequentially numbered sealed opaque envelopes. Venous blood was collected at 15 min intervals from 60 min pre- until 210 min post-basal rate reduction. Changes in plasma free insulin (the primary outcome), and changes in plasma glucose, with exercise were compared with changes when resting. Outcomes were assessed blinded to group assignment. RESULTS: Following basal rate reduction when rested, mean (± SE) free insulin decreased by 4.9 ± 2.9%, 16.2 ± 2.6% and 18.6 ± 3.2% at 1, 2 and 3 h, respectively (p < 0.05 after 75 min). With exercise, relative to rest, mean free insulin increased by 6 ± 2 pmol/l after 15 min and 5 ± 2 pmol/l after 30 min (p < 0.001), then declined post-exercise (p < 0.001). Three participants (mean baseline glucose 5.0 ± 0.1 mmol/l) required glucose supplementation to prevent or treat exercise-related hypoglycaemia. In the other 11 participants (mean baseline glucose 8.4 ± 0.5 mmol/l), glucose increased by 0.8 ± 0.3 mmol/l with exercise (p = 0.028). CONCLUSIONS/INTERPRETATION: Halving the basal insulin rate 1 h prior to exercise did not significantly reduce circulating free insulin by exercise commencement. Exercise itself transiently increased insulin levels. In participants with low-normal glucose pre-exercise, hypoglycaemia was not prevented by insulin basal rate reduction alone. Greater insulin basal rate reduction and supplemental carbohydrate may be required to prevent exercise-induced hypoglycaemia. TRIAL REGISTRATION: ANZCTR.org.au ACTRN12613000581763 FUNDING: Australian Diabetes Society, Hugh DT Williamson Foundation, Lynne Quayle Charitable Trust Fund.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/terapia , Ejercicio Físico/fisiología , Hipoglucemiantes/uso terapéutico , Sistemas de Infusión de Insulina , Insulina/uso terapéutico , Adulto , Glucemia/efectos de los fármacos , Estudios Cruzados , Diabetes Mellitus Tipo 1/sangre , Femenino , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Masculino , Persona de Mediana Edad
14.
BMC Fam Pract ; 15: 82, 2014 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-24886287

RESUMEN

BACKGROUND: Insulin initiation and titration in primary care is necessary to respond to the growing epidemic of type 2 diabetes (T2D). The INITIATION study aims to evaluate the impact of implementing a new model of care with Primary Care Physician and Practice Nurse (PN) teams supported by a Credentialed Diabetes Educator-Registered Nurse (CDE-RN) and endocrinologist in initiating and titrating basal and prandial insulin for T2D patients in the Australian healthcare system over 24 weeks. This study also explores the feasibility and efficacy of retrospective continuous glucose monitoring (r-CGM) in comparison with self-monitoring of blood glucose (SMBG) among people with T2D in primary care. METHODS/DESIGN: The study employs a before and after design with a nested exploratory trial of SMBG and r-CGM. A total of 102 insulin naïve T2D patients with a glycated haemoglobin (HbA1c) level of >7.5% in the previous 6 months while treated with maximal oral therapy will be recruited and screened from 22 primary care practices in Melbourne, Australia. All patients will be commenced on a basal insulin regimen following randomization into one of the two blood glucose monitoring arms, with intensification to a "basal plus" regimen if required. The outcomes of the new model of care will be benchmarked with data collected over the same period from a specialist setting in Melbourne, Australia. DISCUSSION: This article describes the study protocol and insulin treatment algorithm employed in the first study to explore r-CGM use among T2D in primary care. Findings from the INITIATION study will inform development of a larger randomized controlled trial. TRIAL REGISTRATION: ACTRN12610000797077.


Asunto(s)
Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Atención Primaria de Salud , Administración Oral , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Automonitorización de la Glucosa Sanguínea , Protocolos Clínicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Victoria
15.
Heart Lung Circ ; 23(11): 997-1008, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24996388

RESUMEN

The health burden of type 2 diabetes mellitus (T2DM) is increasing worldwide, with a substantial portion of this burden being due to the development of cardiovascular (CV) disease. Multiple individual randomised clinical trials of intensive versus conventional glucose control, based on the use of traditional oral hypoglycaemic agents, have failed to convincingly show that intensive glucose control significantly reduces CV disease outcomes. In recent times, two new approaches to lowering glucose levels have become available. One targets the "incretin effect" which involves the modulation of peptide hormones that normally regulate glucose levels when nutrients are given orally. The other approach is based on inhibiting the sodium-glucose co-transporter 2 (SGLT-2) in the tubules of the kidney to promote glycosuria. Incretin-based therapies, especially glucagon-like peptide-1 receptor analogues, reduce glucose levels, with a low risk of hypoglycaemia, by increasing insulin secretion, inhibiting glucagon release and increasing satiety. Clinical and experimental studies have also shown favourable effects on CV disease risk factors such as dyslipidaemia, blood pressure, and improvements in endothelial function and cardiac contractility. Similarly, SGLT-2 inhibitors reduce glucose levels with a low risk for hypoglycaemia and have positive effects on multiple CV disease risk factors. Whether the beneficial effects of these new glucose lowering approaches on surrogate markers of CV disease risk translates to an improvement in CV events remains unknown. Several CV outcome trials are currently being performed to show that at a minimum, these novel glucose lowering agents are safe, but also have positive CV benefits.


Asunto(s)
Diabetes Mellitus Tipo 1/tratamiento farmacológico , Péptido 1 Similar al Glucagón/uso terapéutico , Incretinas/uso terapéutico , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Glucemia/metabolismo , Complicaciones de la Diabetes/sangre , Complicaciones de la Diabetes/orina , Diabetes Mellitus Tipo 1/sangre , Diabetes Mellitus Tipo 1/orina , Humanos , Túbulos Renales/metabolismo , Transportador 2 de Sodio-Glucosa/metabolismo
16.
J Diabetes Sci Technol ; 18(4): 764-770, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38372246

RESUMEN

BACKGROUND: Glycemia risk index (GRI) is a novel composite metric assessing overall glycemic risk, accounting for both hypoglycemia and hyperglycemia and weighted toward extremes. Data assessing GRI as an outcome measure in closed-loop studies and its relation with conventional key continuous glucose monitoring (CGM) metrics are limited. METHODS: A post hoc analysis was performed to evaluate the sensitivity of GRI in assessing glycemic quality in adults with type 1 diabetes randomized to 26 weeks hybrid closed-loop (HCL) or manual insulin delivery (control). The primary outcome was GRI comparing HCL with control. Comparisons were made with changes in other CGM metrics including time in range (TIR), time above range (TAR), time below range (TBR), and glycemic variability (standard deviation [SD] and coefficient of variation [CV]). RESULTS: GRI with HCL (N = 61) compared with control (N = 59) was significantly lower (mean [SD] 33.5 [11.7] vs 56.1 [14.4], respectively; mean difference -22.8 [-27.2, -18.3], P = .001). The mean increase in TIR was +14.8 (11.0, 18.5)%. GRI negatively correlated with TIR for combined arms (r = -.954; P = .001), and positively with TAR >250 mg/dL (r = .901; P = .001), TBR < 54 mg/dL (r = .416; P = .001), and glycemic variability (SD [r = .916] and CV [r = .732]; P = .001 for both). CONCLUSIONS: Twenty-six weeks of HCL improved GRI, in addition to other CGM metrics, compared with standard insulin therapy. The improvement in GRI was proportionally greater than the change in TIR, and GRI correlated with all CGM metrics. We suggest that GRI may be an appropriate primary outcome for closed-loop trials.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 1 , Hipoglucemiantes , Sistemas de Infusión de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/sangre , Insulina/administración & dosificación , Adulto , Masculino , Femenino , Glucemia/análisis , Glucemia/efectos de los fármacos , Hipoglucemiantes/administración & dosificación , Automonitorización de la Glucosa Sanguínea/métodos , Persona de Mediana Edad , Hipoglucemia/inducido químicamente , Hipoglucemia/sangre , Hipoglucemia/prevención & control , Hipoglucemia/epidemiología , Control Glucémico/métodos , Hiperglucemia/sangre , Hiperglucemia/tratamiento farmacológico
17.
Diabetes Technol Ther ; 26(S3): 84-96, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38377316

RESUMEN

The physical and psychological benefits of exercise are particularly pertinent to people with type 1 diabetes (T1D). The variability in subcutaneous insulin absorption and the delay in offset and onset in glucose lowering action impose limitations, given the rapidly varying insulin requirements with exercise. Simultaneously, there are challenges to glucose monitoring. Consequently, those with T1D are less likely to exercise because of concerns regarding glucose instability. While glucose control with exercise can be enhanced using automated insulin delivery (AID), all commercially available AID systems remain limited by the pharmacokinetics of subcutaneous insulin delivery. Although glycemic responses may vary with exercises of differing intensities and durations, the principles providing the foundation for guidelines include minimization of insulin on board before exercise commencement, judicious and timely carbohydrate supplementation, and when possible, a reduction in insulin delivered in anticipation of planned exercise. There is an increasing body of evidence in support of superior glucose control with AID over manual insulin dosing in people in T1D who wish to exercise. The MiniMed™ 780G AID system varies basal insulin delivery with superimposed automated correction boluses. It incorporates a temporary (elevated glucose) target of 8.3 mmol/L (150 mg/dL) and when it is functioning, the autocorrection boluses are stopped. As the device has recently become commercially available, there are limited data assessing glucose control with the MiniMed™ 780G under exercise conditions. Importantly, when exercise was planned and implemented within consensus guidelines, %time in range and %time below range targets were met. A practical approach to exercising with the device is provided with illustrative case studies. While there are limitations to spontaneity imposed on any AID device due to the pharmacokinetics associated with the subcutaneous delivery of current insulin formulations, the MiniMed™ 780G system provides people with T1D an excellent option for exercising safely if the appropriate strategies are implemented.


Asunto(s)
Diabetes Mellitus Tipo 1 , Insulina , Humanos , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Glucemia , Automonitorización de la Glucosa Sanguínea , Sistemas de Infusión de Insulina , Insulina Regular Humana/uso terapéutico
18.
J Diabetes Complications ; 38(3): 108702, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38387103

RESUMEN

AIMS: To relate adverse events with glucose correction rates in diabetic ketoacidosis (DKA) using variable rate intravenous insulin-infusions (VRIII). METHODS: Retrospective, observational study in adults with DKA who received insulin infusions between 2012 and 2017 at St Vincent's Hospital, Melbourne. Early correction of hyperglycaemia (<10 mmol/L) was evaluated for association with hypoglycaemia (<4.0 mmol/L), hypokalaemia (potassium <3.3 mmol/L) and clinical outcomes via regression analysis. RESULTS: The study involved 97 patients, with 93 % having type 1 diabetes. The mean age was 38 years, 47 % were women and 35 % were admitted to intensive care. Hypoglycaemia rates during 12 and 24 h of treatment were 6.2 % and 8.2 %, respectively with 58 % of patients recording their first BGL <10 mmol/L within 12 h and 88 % within 24 h. Ketone clearance time averaged at 15.6 h. Hyperglycaemia correction rates to <10 mmol/L were not different in those with/without hypoglycaemia at 12/24 h, in multivariate analysis including admission BGL. Hypokalaemia occurred in 40.2 % of patients and was associated with lower pH but not BGL correction rates. CONCLUSION: The VRIII protocol achieved early hyperglycaemia correction and ketoacidosis reversal with low hypoglycaemia risk. However, high hypokalaemia rates suggest the need for aggressive potassium replacement, especially in markedly acidotic patients.


Asunto(s)
Diabetes Mellitus , Cetoacidosis Diabética , Hiperglucemia , Hipoglucemia , Hipopotasemia , Adulto , Femenino , Humanos , Masculino , Cetoacidosis Diabética/tratamiento farmacológico , Cetoacidosis Diabética/epidemiología , Hiperglucemia/prevención & control , Hipoglucemia/inducido químicamente , Hipoglucemia/prevención & control , Hipopotasemia/inducido químicamente , Hipopotasemia/epidemiología , Insulina/efectos adversos , Insulina Regular Humana , Potasio , Estudios Retrospectivos
19.
J Diabetes Investig ; 15(5): 594-597, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38366869

RESUMEN

The gold standard for measuring insulin sensitivity (IS) is the hyperinsulinemic-euglycemic clamp, a time, costly, and labor-intensive research tool. A low insulin sensitivity is associated with a complication-risk in type 1 diabetes. Various formulae using clinical data have been developed and correlated with measured IS in type 1 diabetes. We consolidated multiple formulae into an online calculator (bit.ly/estimated-GDR), enabling comparison of IS and its probability of IS <4.45 mg/kg/min (low) or >6.50 mg/kg/min (high), as measured in a validation set of clamps in 104 adults with type 1 diabetes. Insulin sensitivity calculations using different formulae varied significantly, with correlations (R2) ranging 0.005-0.87 with agreement in detecting low and high glucose disposal rates in the range 49-93% and 89-100%, respectively. We demonstrate that although the calculated IS varies between formulae, their interpretation remains consistent. Our free online calculator offers a user-friendly tool for individual IS calculations and also offers efficient batch processing of data for research.


Asunto(s)
Diabetes Mellitus Tipo 1 , Técnica de Clampeo de la Glucosa , Resistencia a la Insulina , Humanos , Diabetes Mellitus Tipo 1/sangre , Femenino , Adulto , Masculino , Glucemia/análisis , Persona de Mediana Edad , Insulina
20.
J Clin Endocrinol Metab ; 109(8): 1984-1995, 2024 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-38373265

RESUMEN

CONTEXT: Omnipod DASH Insulin Management System is a tubeless insulin pump that overcomes the physical inconveniences of conventional tubed insulin pump therapy (IPT). OBJECTIVE: We compared treatment satisfaction with Omnipod DASH System to usual care (multiple daily injections [MDIs] or tubed IPT) in adults with type 1 diabetes using self-monitoring blood glucose (SMBG). METHODS: Adults with type 1 diabetes on MDI (n = 40) or IPT (n = 25) from 4 diabetes centers in Australia were randomly assigned in a 1:1 nonblinded manner to Omnipod DASH System (Omnipod group) or continue usual care (Usual Care group) for 12 weeks, followed by a further 12-week extension during which all participants used the device. The primary outcome was treatment satisfaction assessed by change in Diabetes Technology Questionnaire "current" (ΔDTQ-current) score at 12 weeks (study end). Secondary outcomes included ΔDTQ-current following extension and other participant-reported outcomes (PROs) measuring quality of life, burden of disease treatment, and glycemic and device-related outcomes at 12 weeks (study end) and 24 weeks (end extension). RESULTS: Treatment satisfaction improved more in the Omnipod group vs the Usual Care group (ΔDTQ-current score of 16.4 [21.2] vs 0.0 [12.8]; P < .001) at study end. Significantly greater improvements in other PROs and glycated hemoglobin A1c were also observed. Improvements in DTQ-current and other PROs comparing study end and end extension were similar. While percentage in time in range change from baseline did not differ at study end (-2.0 [12.7] %), it was significantly greater at end extension (5.6 [10.9] %; P = .016). CONCLUSION: The Omnipod DASH System resulted in greater treatment satisfaction at 12 weeks in adults with type 1 diabetes using SMBG that was sustained after 24 weeks of device use without compromising sleep quality and fear of hypoglycemia. Improvements in glycemia were also observed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA