Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Lipid Res ; 53(5): 1012-1020, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22345709

RESUMEN

Quantitative analysis of mitochondrial FA ß-oxidation (FAO) has drawn increasing interest for defining lipid-induced metabolic dysfunctions, such as in obesity-induced insulin resistance, and evaluating pharmacologic strategies to improve ß-oxidation function. The aim was to develop a new assay to quantify ß-oxidation function in intact mitochondria and with a low amount of cell material. Cell membranes of primary human fibroblasts were permeabilized with digitonin prior to a load with FFA substrate. Following 120 min of incubation, the various generated acylcarnitines were extracted from both cells and incubation medium by protein precipitation/desalting and subjected to solid-phase extraction. A panel of 30 acylcarnitines per well was quantified by MS/MS and normalized to citrate synthase activity to analyze mitochondrial metabolite flux. Pretreatment with bezafibrate and etomoxir revealed stimulating and inhibiting regulatory effects on ß-oxidation function, respectively. In addition to the advantage of a much shorter assay time due to in situ permeabilization compared with whole-cell incubation systems, the method allows the detection of multiple acylcarnitines from an only limited amount of intact cells, particularly relevant to the use of primary cells. This novel approach facilitates highly sensitive, simple, and fast monitoring of pharmacological effects on FAO.


Asunto(s)
Membrana Celular/metabolismo , Ácidos Grasos/metabolismo , Metabolómica/métodos , Línea Celular , Permeabilidad de la Membrana Celular , Niño , Fibroblastos/citología , Humanos , Recién Nacido , Metabolómica/economía , Mitocondrias/metabolismo , Oxidación-Reducción , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Factores de Tiempo
2.
Clin Chem ; 57(4): 623-6, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21335445

RESUMEN

BACKGROUND: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) has been used in the Bavarian newborn screening (NBS) program since 1999. The use of ESI-MS/MS has led to the inclusion of isovaleric acidemia (IVA) into NBS. We retrospectively evaluated data on more than 1.6 million newborns screened during 9.5 years. METHODS: Acylcarnitines from whole blood spotted on filter paper were converted to their corresponding butyl esters, and the samples were analyzed by use of ESI-MS/MS with stable isotope labeled internal standards. RESULTS: A total of 24 individuals with IVA were detected by use of a multiparametric threshold criteria panel including isovalerylcarnitine (C5) and the ratios of C5 to octanoyl-, butyryl-, and propionylcarnitine. A cutoff set at the 99.99th percentile for isolated C5 or at the 99th percentile for C5 plus at least 2 ratios resulted in a positive predictive value for IVA screening of 7.0% and an overall recall rate of 0.024%. Adjusted reference ranges for age and birth weight were applied, and the incidence of IVA in the study population was calculated to be 1 in 67,000. Missed cases were not brought to our attention. IVA was also detectable in cord blood and early postnatal blood samples. CONCLUSIONS: IVA can be reliably detected in NBS through acylcarnitine analysis in dried blood spots by using multiparametric threshold criteria. Further improvement (positive predictive value 13.0%, recall rate 0.01%) can be achieved by using more stringent recall criteria. In view of the potentially life-threatening natural course of IVA in early life, presymptomatic diagnosis may thus prevent mortality and morbidity.


Asunto(s)
Tamizaje Neonatal , Ácidos Pentanoicos/sangre , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Hemiterpenos , Humanos , Recién Nacido
3.
Orphanet J Rare Dis ; 16(1): 153, 2021 03 31.
Artículo en Inglés | MEDLINE | ID: mdl-33789695

RESUMEN

BACKGROUND: Spinal muscular atrophy (SMA) is the most common neurodegenerative disease in childhood. Since motor neuron injury is usually not reversible, early diagnosis and treatment are essential to prevent major disability. Our objective was to assess the impact of genetic newborn screening for SMA on outcome. METHODS: We provided clinical data from 43 SMA patients, identified via polymerase chain reaction of the SMN1 gene from dried blood spots between January 2018 and January 2020 in Germany. Follow-up included neurophysiological examinations and standardized physiotherapeutic testing. RESULTS: Detection of SMA with newborn screening was consistent with known incidence in Germany. Birth prevalence was 1:6910; 39.5% had 2 SMN2 copies, 23% had 3 SMN2 copies, 32.5% had 4 copies, and 4.5% had 5 copies of the SMN2 gene. Treatment with SMA-specific medication could be started at the age of 14-39 days in 21 patients. Pre-symptomatically treated patients remained throughout asymptomatic within the observation period. 47% of patients with 2 SMN2 copies showed early, presumably intrauterine onset of disease. These patients reached motor milestones with delay; none of them developed respiratory symptoms. Untreated children with 2 SMN2 copies died. Untreated children with 3 SMN2 copies developed proximal weakness in their first year. In patients with ≥ 4 SMN2 copies, a follow-up strategy of "watchful waiting" was applied despite the fact that one of them was treated from the age of 6 months. Two infant siblings with 4 SMN2 copies were identified with a missed diagnosis of SMA type 3. CONCLUSION: Identification of newborns with infantile SMA and prompt SMA-specific treatment substantially improves neurodevelopmental outcome, and we recommend implementation in the public newborn screening in countries where therapy is available. Electrophysiology is a relevant parameter to support the urgency of therapy. There has to be a short time interval between a positive screening result and referral to a therapy-ready specialized treatment center.


Asunto(s)
Atrofia Muscular Espinal , Enfermedades Neurodegenerativas , Atrofias Musculares Espinales de la Infancia , Niño , Alemania , Humanos , Lactante , Recién Nacido , Atrofia Muscular Espinal/diagnóstico , Atrofia Muscular Espinal/genética , Tamizaje Neonatal , Atrofias Musculares Espinales de la Infancia/diagnóstico , Atrofias Musculares Espinales de la Infancia/genética , Proteína 1 para la Supervivencia de la Neurona Motora/genética
4.
Anal Chem ; 81(9): 3571-5, 2009 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-19323528

RESUMEN

OBJECTIVE: Electrospray ionization-tandem mass spectrometry (ESI-MS/MS) is increasingly used in newborn screening programs. Acylcarnitine profiles from dried blood spots (DBS) are used to detect fatty acid oxidation disorders, carnitine cycle disorders, and organic acidurias. Stored dried blood is also a valuable source for postmortem investigations to unravel the cause of unexplained death in early childhood. However, diagnostic uncertainties arising from the unknown stability of acylcarnitines and free carnitine during prolonged storage have not yet been studied in a systematic manner. METHODS: Whole blood spiked with acylcarnitines was stored either at -18 degrees C or at room temperature up to 1000 days. At regular time intervals 3.2 mm spots of these samples were extracted with 150 microL of methanol. Free carnitine and acylcarnitines were converted to their corresponding butyl esters and analyzed by ESI-MS/MS. RESULTS: At -18 degrees C acylcarnitines are stable for at least 330 days. If stored for prolonged periods at room temperature (>14 days), acylcarnitines are hydrolyzed to free carnitine and the corresponding fatty acids. The velocity of decay is logarithmic and depends on the chain length of the acylcarnitines. Short-chain acylcarnitines hydrolyze quicker than long-chain acylcarnitines. CONCLUSION: The data indicate that stored filter cards should only be used for retrospective quantitation of acylcarnitines if appropriate correction for sample decay during storage is applied. Free carnitine increases upon storage but can reliably be quantitated under standardized derivatization conditions. Furthermore, carnitine transporter (OCTN2) deficiency can reliably be diagnosed by examining acylcarnitine profiles, which can supplement free carnitine levels as a discriminatory marker.


Asunto(s)
Carnitina/análogos & derivados , Carnitina/sangre , Errores Innatos del Metabolismo/diagnóstico , Tamizaje Neonatal , Proteínas de Transporte de Catión Orgánico/deficiencia , Manejo de Especímenes/métodos , Carnitina/química , Carnitina/metabolismo , Desecación , Humanos , Recién Nacido , Modelos Lineales , Errores Innatos del Metabolismo/sangre , Reproducibilidad de los Resultados , Estudios Retrospectivos , Miembro 5 de la Familia 22 de Transportadores de Solutos , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Temperatura
5.
Anal Bioanal Chem ; 393(5): 1481-97, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19043700

RESUMEN

Newborn screening for inborn errors of metabolism and endocrinopathies has expanded during the last two decades, mainly owing to the introduction of new technologies such as tandem mass spectrometry and DNA analysis. However, every expansion of the screening panel requires critical review, discussion, and pilot studies. Different legal regulations and ethical concerns may lead to different decisions. Without claiming to be comprehensive, this review tries to give an overview of newborn screening, including its main problems and target diseases.


Asunto(s)
Enfermedades del Sistema Endocrino , Errores Innatos del Metabolismo , Tamizaje Neonatal , Enfermedades del Sistema Endocrino/diagnóstico , Enfermedades del Sistema Endocrino/epidemiología , Enfermedades del Sistema Endocrino/terapia , Humanos , Recién Nacido , Errores Innatos del Metabolismo/diagnóstico , Errores Innatos del Metabolismo/epidemiología , Errores Innatos del Metabolismo/terapia
6.
Eur J Pediatr ; 168(5): 553-8, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-18651177

RESUMEN

Newborn screening programs use whole blood dried on filter paper as the standard specimen. Metabolites are reasonably stable and can easily be sent to screening laboratories by regular mail. The recommended sample collection procedure is to spot native blood without anticoagulants onto the filter paper, because anticoagulants can interfere with the different laboratory methods. However, visual examination of the blood spots cannot always detect contamination. In this study, whole blood was drawn by venous puncture from a healthy volunteer, spiked with the corresponding metabolites and EDTA, and spotted onto filter paper. TSH and 17alpha-hydroxyprogesterone were determined by time resolved fluoroimmunoassays with the AutoDelfia system. Total galactose, biotinidase activity, and galactose-1-phosphate uridyltransferase activity were measured photometrically or fluorometrically. Succinyl acetone was estimated indirectly through the inhibition of porphobilinogen synthase activity (PBGS assay). EDTA, amino acids, and acylcarnitines were converted to the corresponding butyl esters, after extraction with methanol, and analysed by LC-MS/MS. EDTA contamination gives falsely elevated 17-OHP values and falsely reduced TSH and PBGS values. The inclusion of an EDTA determination in routine screening revealed that at least 0.06% of newborn screening samples were contaminated with EDTA. In conclusion, non-conformity during the pre-analytical phase is a source of false positive and false negative screening results. Determination of EDTA from NBS blood spots can reliably identify these samples and prevent screening errors.


Asunto(s)
Ácido Edético/sangre , Tamizaje Neonatal , Espectrometría de Masas en Tándem/métodos , Humanos , Recién Nacido
7.
Acta Cytol ; 53(4): 396-401, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19697723

RESUMEN

OBJECTIVE: To determine whether the absence ofHPV1i6 LI capsid protein is a prognostic parameter for the histologic outcome of cervical intraepithelial neoplasia (CIN) 2+ in cytologically diagnosed cervical dysplasia. STUDY DESIGN: Papanicolaou-stained microscopic slides of 95 HPV16-positive cervical samples that had a cytologic diagnosis of cervical dysplasia or borderline cytology were immunostained using an HPV16-specific anti-L1 viral capsid antibody. In parallel to the cytologic examination, HPV16 DNA and E6*I mRNA were quantitated using real-time polymerase chain reaction. Expression of L1 protein was correlated with relative levels of HPV16 DNA and E6*I mRNA as well as histologic diagnoses/cytologic follow-up. RESULTS: Thirty-five cases with a histologic diagnosis of CIN 2+ (61%) were negative for HPV16 L1 protein; 22 (39%) were positive. Of the cases that either were CIN 1 or regressed to normal cytology, 10 cases (26%) were positive for HPV16 L1 protein, while 28 (74%) were negative. L1-negative and L1-positive cases showed no statistically significant difference (p = 0.22) in their histologic diagnosis/cytologic follow-up. The positive predictive value for CIN 2+ was 56% if L1 protein was absent; the negative predictivre value for CIN 1/regression to normal cytology was 31% if L1 protein was present. HPV16 Ll-positive cases had significantly higher HPV16 DNA concentrations than L1-negative cases (p < 0.001), while levels of HPV16 E6*I mRNA were comparable in both types of cases (p = 0.36). CONCLUSION: The expression of HPV16 L1 capsid protein is correlated with viral DNA load but does not predict the histologic outcome of HPV16-positive cervical dysplasia.


Asunto(s)
Proteínas de la Cápside/metabolismo , ADN Viral/análisis , Papillomavirus Humano 16/genética , Proteínas Oncogénicas Virales/metabolismo , Proteínas Represoras/metabolismo , Displasia del Cuello del Útero/virología , Biomarcadores/análisis , Femenino , Humanos , Inmunohistoquímica , Valor Predictivo de las Pruebas , ARN Mensajero/análisis , Displasia del Cuello del Útero/patología
8.
J Neuromuscul Dis ; 6(4): 503-515, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31594245

RESUMEN

OBJECTIVE: Spinal muscular atrophy (SMA) is the most common neurodegenerative disease in childhood. The study was conducted to assess the impact of early detection of SMA by newborn screening (NBS) on the clinical course of the disease. METHODS: Screening was performed in two federal states of Germany, Bavaria and North Rhine Westphalia, between January 2018 and February 2019. The incidence in the screening population was calculated as number of detected patients with a homozygous deletion in the SMN1-gene per number of screened patients. To get an idea about the incidence of newly diagnosed SMA in the year prior to screening a survey covering all neuropediatric centers in the state of Bavaria was conducted, identifying all SMA-cases in 2017 and 2018. Following positive NBS and confirmatory diagnostic test, treatment was advised according to the recommendations of the "American SMA NBS Multidisciplinary Working Group". Immediate treatment with Nusinersen was recommended in children with 2 and 3 SMN2 copies and a conservative strict follow-up strategy in children with ≥4 copies. All children underwent regular standardized neuropediatric examination, CHOP INTEND and HINE-2 testing as well as electrophysiological exams every 2-3 months. RESULTS: 165,525 children were screened. 22 cases of SMA were identified, meaning an incidence rate of 1:7524. SMN2 copy number analysis showed 2 SMN2 copies in 45% of patients, 3 SMN2 copies in 19 % and 4 SMN2 copies in 36%. These findings are confirmed in the most recent statistical data-cut from 31st August 2019 (incidence 1:7089, 2 SMN2 copies in 44%, 3 in 15% and 4 in 38%). Comparison with up-to-date German data on SMA incidence and the Bavarian survey give evidence that NBS did not lead to a relevant increase in incidence. 10 patients with 2 or 3 SMN2 copies were treated with Nusinersen, starting between 15- 39 days after birth, in 7/10 patients before onset of symptoms. Presymptomatically treated patients (age at last examination: 1- 12 months, median 8 months) showed no muscle weakness by the age of one month to one year. One child with 4 SMN2 copies became symptomatic at the age of 8 months. CONCLUSIONS: Newborn screening, resulting in presymptomatic treatment, improves outcome in children with genetically proven SMA. Newborn screening for SMA should be introduced in all countries where therapy is available. An immediate therapy in cases with 4 SMN2 copies should be considered.


Asunto(s)
Atrofia Muscular Espinal/genética , Enfermedades Neurodegenerativas/genética , Eliminación de Secuencia/genética , Atrofias Musculares Espinales de la Infancia/genética , Adulto , Niño , Preescolar , Femenino , Homocigoto , Humanos , Lactante , Recién Nacido , Masculino , Atrofia Muscular Espinal/terapia , Tamizaje Neonatal/métodos , Enfermedades Neurodegenerativas/terapia , Fenotipo , Proyectos Piloto , Atrofias Musculares Espinales de la Infancia/tratamiento farmacológico , Proteína 1 para la Supervivencia de la Neurona Motora/genética , Proteína 2 para la Supervivencia de la Neurona Motora/genética
9.
Hum Mutat ; 27(8): 748-59, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16835865

RESUMEN

New technology enables expansion of newborn screening (NBS) of inborn errors aimed to prevent adverse outcome. In conditions with a large share of asymptomatic phenotypes, the potential harm created by NBS must carefully be weighed against benefit. Policies vary throughout the United States, Australia, and Europe due to limited data on outcome and treatability of candidate screening conditions. We elaborated the rationale for decision making in 3-methylcrotonyl-coenzyme A (CoA) carboxylase deficiency (MCCD), which afflicts leucine catabolism, with reported outcomes ranging from asymptomatic to death. In Bavaria, we screened 677,852 neonates for 25 conditions, including MCCD, based on elevated concentrations of 3-hydroxyisovalerylcarnitine (3-HIVA-C). Genotypes of MCCA (MCCC1) and MCCB (MCCC2) were assessed in identified newborns, their relatives, and in individuals (n = 17) from other regions, and correlated to biochemical and clinical phenotypes. NBS revealed eight newborns and six relatives with MCCD, suggesting a higher frequency than previously assumed (1:84,700). We found a strikingly heterogeneous spectrum of 22 novel and eight reported mutations. Allelic variants were neither related to biochemical nor anamnestic data of our probands showing all asymptomatic or benign phenotypes. Comparative analysis of case reports with NBS data implied that only few individuals (< 10%) develop symptoms. In addition, none of the symptoms reported so far can clearly be attributed to MCCD. MCCD is a genetic condition with low clinical expressivity and penetrance. It largely represents as nondisease. So far, there are no genetic or biochemical markers that would identify the few individuals potentially at risk for harmful clinical expression. The low ratio of benefit to harm was pivotal to the decision to exclude MCCD from NBS in Germany. MCCD may be regarded as exemplary of the ongoing controversy arising from the inclusion of potentially asymptomatic conditions, which generates a psychological burden for afflicted families and a financial burden for health care systems.


Asunto(s)
Ligasas de Carbono-Carbono/deficiencia , Heterogeneidad Genética , Mutación , Tamizaje Neonatal/legislación & jurisprudencia , Alelos , Ligasas de Carbono-Carbono/genética , Estudios de Cohortes , Enfermedades Carenciales/diagnóstico , Enfermedades Carenciales/genética , Femenino , Genotipo , Alemania , Humanos , Recién Nacido , Masculino , Penetrancia , Medición de Riesgo
10.
Hum Mutat ; 25(5): 443-52, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15832312

RESUMEN

Medium-chain acyl-CoA dehydrogenase deficiency (MCADD) is the most frequent inherited defect of fatty acid oxidation, with a significant morbidity and mortality in undiagnosed patients. Adverse outcomes can effectively be prevented by avoiding metabolic stress and following simple dietary measures. Therefore, prospective newborn screening (NBS) is being proposed for this condition. However, technical validation of MCADD population screening and assessment of its overall benefit require broadening of the as-yet-scarce knowledge of the MCADD genetic heterogeneity unraveled by NBS and its phenotypic consequences. Here, we describe the entire spectrum of sequence variations occurring in newborns with MCADD in the population of Bavaria, Germany, in relation to the biochemical phenotype. Among 524,287 newborns, we identified 62 cases of MCADD, indicating a birth incidence of 1 in 8,456. In all of the 57 newborns available for analysis, two alterations within the MCADD gene (ACADM) were identified. The most prevalent alteration c.985A>G (Lys329Glu) occurred in 27 (47%) newborns in the homozygous and in 18 (32%) in the heterozygous state (63% of defective alleles). The mild folding variant c.199T>C (Tyr67His) was identified in nine individuals, six of them being compound heterozygous with c.985A>G (Lys329Glu). Neither of the prevalent alterations were found in the remaining nine newborns. A total of 18 sequence variations were identified; 13 of them were novel: eight missense mutations, one nonsense mutation, two splice variants, and two small deletions. The remaining five were previously reported in MCADD patients. The ACADM heterogeneity uncovered was larger as anticipated from previous c.985A>G (Lys329Glu) carrier screening data. In addition, we show that MCADD appears to occur as frequently in Turkish newborns as in the native German population. Our data validate that biochemical NBS for MCADD is a highly specific procedure for disease detection, with the identification of a significant share of milder biochemical phenotypes, such as c.199T>C (Tyr67His). These show statistically lower acylcarnitine markers, allowing us to distinguish subgroups within the spectrum of ACADM sequence variations that correlate to biochemical MCADD disease expression. Our data might provide technical and medical guidance for decision making in the worldwide efforts to introduce MCADD population screening.


Asunto(s)
Acil-CoA Deshidrogenasa/deficiencia , Acil-CoA Deshidrogenasa/genética , Tamizaje Neonatal , Secuencia de Bases , Biomarcadores , Enfermedades Carenciales/diagnóstico , Enfermedades Carenciales/epidemiología , Predisposición Genética a la Enfermedad , Alemania/epidemiología , Humanos , Recién Nacido , Espectrometría de Masas , Datos de Secuencia Molecular , Mutación , Fenotipo , Análisis de Secuencia de ADN , Turquía/epidemiología
11.
J Clin Endocrinol Metab ; 88(12): 5790-4, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14671170

RESUMEN

Newborn screening procedures for congenital adrenal hyperplasia (CAH) are still suboptimal because of low specificity, particularly in premature infants. This study evaluated a multitiered strategy for reporting abnormal 17-hydroxyprogesterone screening values that simultaneously takes into account not only birth weight but also age at sampling. A cautious three-tiered cut-off scheme was used during the initial 24 months of CAH screening in Bavaria. Data were then reanalyzed using five birth weight classes to reflect more precisely the markedly higher values in low-birth-weight newborns. Because 17-hydroxyprogesterone values apparently decline with increasing age, these classes were then further subdivided into a total of 21 groups according to the age at sampling. Based on this reanalysis, we defined new multitiered cut-off levels and used them for the next 18 months. A total of 538466 newborns were screened from January 1999 to June 2002; 51 CAH cases were detected. Application of the new threshold values resulted in a 35% reduction of the total recall rate (from 1.13% to 0.74%) and an increase in the positive predictive value from 0.84% to 1.29% without reducing diagnostic sensitivity. This improvement of CAH screening can be achieved by simply using request forms that ask for both age and birth weight at the time of sampling.


Asunto(s)
17-alfa-Hidroxiprogesterona/sangre , Hiperplasia Suprarrenal Congénita/diagnóstico , Envejecimiento , Peso al Nacer , Tamizaje Neonatal , Hiperplasia Suprarrenal Congénita/sangre , Hiperplasia Suprarrenal Congénita/epidemiología , Reacciones Falso Negativas , Alemania/epidemiología , Humanos , Incidencia , Lactante , Recién Nacido , Tamizaje Neonatal/métodos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
12.
Dtsch Arztebl Int ; 108(1-2): 11-21; quiz 22, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21285998

RESUMEN

BACKGROUND: Neonatal screening for treatable endocrinopathies and inborn errors of metabolism is an important preventive measure. Advances in the diagnosis and treatment of these diseases have made it necessary to expand the screening program. METHODS: This article is based on a selective literature review and our clinical experience. RESULTS: In 2005, neonatal screening in Germany was expanded from 3 to 14 diseases, as mandated by the responsible governmental authority (the Gemeinsamer Bundesausschuss, i.e., Joint Federal Committee). From 2005 to 2008, screening revealed diseases requiring treatment in 1932 out of a total of 2,758,633 newborns (prevalence, 1 in 1428). The expansion of the screening program resulted in a 57% increase in the overall number of cases detected and a 92% increase for metabolic diseases alone. CONCLUSION: The German neonatal screening program for treatable endocrinopathies and inborn errors of metabolism is a complex and integrated preventive measure that has become markedly more effective as a result of its expansion in 2005.


Asunto(s)
Enfermedades del Sistema Endocrino/diagnóstico , Enfermedades del Sistema Endocrino/prevención & control , Enfermedades Metabólicas/diagnóstico , Enfermedades Metabólicas/prevención & control , Tamizaje Neonatal/métodos , Tamizaje Neonatal/tendencias , Femenino , Humanos , Recién Nacido , Masculino
13.
J Clin Microbiol ; 43(4): 1564-9, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15814966

RESUMEN

We present a sensitive and specific assay for reliable and flexible detection of members of the Mycobacterium tuberculosis complex (MTBC) in clinical samples. This real-time PCR assay, which uses the LightCycler 2.0 instrument and 100-mul glass capillaries, can provide a result within 1 h after DNA extraction. The primers amplify a 206-bp fragment of the MTBC 16S rRNA gene. The sensor hybridization probe targets a region highly specific to members of the MTBC. The assay also includes a novel type of internal control that monitors the function of the reaction components and can detect potential inhibitors. Template DNA was extracted by the same procedure used for the COBAS AMPLICOR M. tuberculosis assay, so the LightCycler assay could be directly compared to the COBAS AMPLICOR assay. The LightCycler assay was evaluated with 146 clinical samples of various types. Very good agreement (100% sensitivity, 98.6% specificity) could be shown between the LightCycler and COBAS AMPLICOR assays. Specificity was checked with a panel of nontuberculous mycobacteria, as well as a large panel of bacterial and fungal organisms.


Asunto(s)
Mycobacterium tuberculosis/aislamiento & purificación , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Juego de Reactivos para Diagnóstico , Tuberculosis Pulmonar/diagnóstico , Tuberculosis Pulmonar/microbiología , ADN Bacteriano/análisis , ADN Bacteriano/aislamiento & purificación , Humanos , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Técnicas de Amplificación de Ácido Nucleico/métodos , Sondas de Oligonucleótidos , Sensibilidad y Especificidad , Manejo de Especímenes , Factores de Tiempo
14.
Clin Chem ; 51(2): 298-304, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15608154

RESUMEN

BACKGROUND: Neonatal screening for steroid 21-hydroxylase (CYP21) deficiency is performed to identify congenital adrenal hyperplasia (CAH). The immunologic assay for 17alpha-hydroxyprogesterone (17-OHP) has a high rate of false positives. We assessed the potential for increasing the specificity for CAH by use of a second step involving analysis of the CYP21 gene. METHODS: Between January 1999 and December 2003, a total of 810,000 newborns were screened. Of these, 7920 had to be retested because their 17-OHP values were above the cutoff of the assay. Sixty-one had positive 17-OHP values in their recall samples and were diagnosed as having CAH. We used a rapid assay for common mutations of the CYP21 gene to analyze these 61 samples. In a prospective study, 198 consecutive samples that had increased 17-OHP and 100 samples that had normal 17-OHP concentrations were genotyped. RESULTS: Fifty-nine of 61 cases diagnosed as having CAH were confirmed genetically as CYP21 deficiencies. One patient had a 3beta-hydroxysteroid dehydrogenase deficiency, and one patient carried no CYP21 mutations. The 198 increased 17-OHP results were designated as false positives after immunologic testing of recall samples. None of these samples exhibited the genetic pattern consistent with CYP21 deficiency. CONCLUSIONS: If samples with increased 17-OHP values were screened genetically, the number of retests would decrease by approximately 90%, but the overall sensitivity of CAH screening would remain the same. Adding a second-tier genetic step would require a modest increase in costs, but is counterbalanced by fewer recalls, less clinical follow-up, and a reduction in unnecessary worry for families.


Asunto(s)
Hiperplasia Suprarrenal Congénita/genética , Tamizaje Neonatal/métodos , Esteroide 21-Hidroxilasa/genética , 17-alfa-Hidroxiprogesterona/sangre , Hiperplasia Suprarrenal Congénita/enzimología , Autoanálisis , Reacciones Falso Positivas , Humanos , Inmunoensayo , Recién Nacido , Reacción en Cadena de la Polimerasa , Estudios Prospectivos , Sensibilidad y Especificidad
15.
Clin Chem ; 50(5): 819-25, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15010426

RESUMEN

BACKGROUND: In real-time PCR assays, the most accurate way to identify false-negative results, e.g., those caused by PCR inhibitors, is to add to samples an internal control that will be coamplified with the target (e.g., pathogen) DNA. Current internal control procedures, however, which usually involve the introduction of a DNA fragment, are complex, time-consuming, and expensive. METHODS: Single-stranded oligonucleotides, which contain little more than primer and probe binding sites, were used as internal controls in real-time PCR assays. Mismatches were included in the probe-binding region of the internal control oligonucleotide (ICO) to prevent probe-control hybridization during the fluorescence acquisition step of the PCR. Amplified ICOs were detected by melting point analysis. ICOs could be added directly to the sample material before DNA extraction. RESULTS: To demonstrate the feasibility of the new approach, we designed ICOs for the LightCycler hybridization probe assays for Mycobacterium tuberculosis complex, hepatitis B virus, herpes simplex virus, and varicella zoster virus. In each case, the controls did not interfere with detection of the pathogen, but were clearly detectable during a subsequent melting point analysis. CONCLUSIONS: A single-stranded oligonucleotide that mimics the target region of the pathogen but is clearly distinguishable from the target during melting point analysis can serve as a simple, cost-effective internal control for real-time amplification assays. Such control oligonucleotides are easy to design and inexpensive. A costly second probe system is not necessary. Moreover, the internally controlled assay uses only one fluorescence detection channel of the instrument, leaving the second channel free for multiplex applications.


Asunto(s)
Oligonucleótidos/química , Reacción en Cadena de la Polimerasa/métodos , Secuencia de Bases , Reacciones Falso Negativas , Estudios de Factibilidad , Fluorescencia , Virus de la Hepatitis B/genética , Herpesvirus Humano 3/genética , Datos de Secuencia Molecular , Mycobacterium bovis/genética , Mycobacterium tuberculosis/genética , Simplexvirus/genética
16.
Eur J Pediatr ; 162 Suppl 1: S67-76, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14618396

RESUMEN

UNLABELLED: Gas chromatography/mass spectrometry became available more than 30 years ago and has subsequently profoundly contributed not only in the identification of a wide range of inborn errors but also as a key tool for clinical diagnostic screening of genetic metabolic disease. Due to extraordinary advances in liquid chromatography and mass spectrometry (MS) developed in the last decade, the utilisation of MS and the potential number of applications for the purpose of metabolic screening is currently undergoing considerable expansion. CONCLUSIONS: This overview aims to describe only current new developments in clinically most relevant applications, in particular with focus on low molecular weight compounds.


Asunto(s)
Espectrometría de Masas/tendencias , Errores Innatos del Metabolismo , Humanos , Recién Nacido , Errores Innatos del Metabolismo/clasificación , Errores Innatos del Metabolismo/diagnóstico , Errores Innatos del Metabolismo/genética
17.
Clin Chem Lab Med ; 41(6): 787-91, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12880142

RESUMEN

Human papillomaviruses (HPV) are known to cause cervical dysplasia and cervical carcinoma. We used a 3-step PCR protocol that allows rapid type-specific HPV testing in a routine laboratory setting: HPV-16-positive samples were determined using a specific LightCycler PCR; HPV-16-negative samples were amplified by nested PCR and typed by sequence analysis. During a period of 7 months, 1275 PCR-based HPV tests were performed. Of the 1275 samples, 829 samples tested negative for HPV and 446 tested positive, including 124 positives found in the initial HPV-16-specific LightCycler assay. Sequence analysis of 132 samples detected 18 HPV types that are not included in the widely used Hybrid Capture II assay. For comparison, the first 100 cervical specimens were tested in parallel using PCR and direct hybridisation (Hybrid Capture II assay). PCR detected HPV DNA in 23 samples that tested negative in the Hybrid Capture assay. Four out of 37 samples that tested positive for HPV in the Hybrid Capture test may be false positives, because sequence analysis detected HPV types not included in the probe mixtures. As rare and novel HPV types may also confer an oncogenic risk, highly sensitive and specific PCR assays will help in understanding cervical HPV infection and cervical cancer of unknown causes.


Asunto(s)
ADN Viral/genética , Papillomaviridae/genética , Infecciones por Papillomavirus/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cuello del Útero/virología , ADN Viral/química , Femenino , Humanos , Hibridación in Situ/métodos , Persona de Mediana Edad , Papillomaviridae/clasificación , Infecciones por Papillomavirus/virología , Sensibilidad y Especificidad , Análisis de Secuencia de ADN/métodos
18.
Prev Med ; 34(2): 127-31, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11817906

RESUMEN

OBJECTIVES: In Bavaria, Germany, an expanded MS-MS-based newborn screening program was implemented in 1999. The coverage of new additional conditions and novelty of technology required introduction of written parental consent. Here we evaluated the influence of the consent procedure on compliance by systematic demographic tracking. METHODS: Comprehensive information was provided for parents, professionals, and the public. Screening notifications were matched with all birth notifications on name and date of birth. Parents of children without screening notification were contacted and counseled. RESULTS: Between August 1, 1999, and July 31, 2000, 123,284 children eligible for screening were born. Of these, 116,652 were matched successfully. Among 6,632 parents contacted, 2,516 (2%) did not respond. Three thousand thirty-four children were screened but the parents initially refused to participate in tracking. Five hundred ninety-four were screened outside the program. Four hundred eighty-eight untested newborns were identified. Three hundred twenty-five screening failures due to logistic problems were tested subsequently. Screening was definitely refused by the parents of 163 children (0.1% of target population). CONCLUSIONS: With appropriate information provided and surveillance by tracking, high compliance with newborn screening can be achieved despite a written consent requirement.


Asunto(s)
Espectrometría de Masas/estadística & datos numéricos , Errores Innatos del Metabolismo/diagnóstico , Tamizaje Neonatal/estadística & datos numéricos , Cooperación del Paciente , Consentimiento por Terceros , Adulto , Femenino , Alemania , Humanos , Recién Nacido , Masculino
19.
Prev Med ; 34(2): 132-7, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11817907

RESUMEN

OBJECTIVES: Expansion of newborn screening programs may increase the risk of missing cases through procedural failures. A coordinated process quality assurance procedure to track recalls was, therefore, introduced in parallel to expansion (including MS-MS and 17alpha-OHP) in Bavaria. METHODS: Using comprehensive computerized registration and automated monitoring a state-funded center coordinated all individual measures to achieve complete testing of all repeat requests-case-specific contacts to physicians, midwives, and parents. Mailing and phoning from the center were supplemented by local public health activities including home visits if needed. RESULTS: Among 243,422 children tested in 1999 and 2000 overall recall was 3.62% (8,809 children): 0.30% (726) were due to sample inadequacy, 1.35% (3,282) to early sampling (<48 h), and 1.97% (4,801) to abnormal results. Of all recalls, 80.9% were received following the initial request, 1,679 (19.1%) required special efforts. Of these, 873 were achieved following a single and 601 following repeated central activities, and 102 were achieved following local support. Sixty-three cases of parental refusal and 47 untraceable children remained. Altogether, 98.8% recalls were achieved, corresponding to 99.96% of all tested children for which definite screening results could be obtained. CONCLUSIONS: Expansion of newborn screening programs does not necessarily mean unsolvable problems in tracking of recalls if adequate logistics is established in parallel.


Asunto(s)
Espectrometría de Masas/estadística & datos numéricos , Tamizaje Neonatal/organización & administración , Cooperación del Paciente , Alemania , Humanos , Recién Nacido , Tamizaje Neonatal/estadística & datos numéricos , Consentimiento por Terceros