Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38729166

RESUMEN

BACKGROUND: The increasing presence of female doctors in the field of cardiac surgery has raised questions about their surgical quality compared to their male colleagues. Despite their success, female surgeons are still underrepresented in leadership positions, and biases and concerns regarding their performance persist. This study aims to examine whether female surgeons perform worse, equally well, or better than their male counterparts in commonly performed procedures that have a significant number of female patients. METHOD: A retrospective cohort of patients from 2011 to 2020 who underwent isolated coronary artery bypass graft (CABG) and aortic valve surgery was studied. To compare the surgical quality of men and women, a 1:1 propensity score matching (two groups of 680 patients operated by men and women, respectively, factors: age, logarithm of EuroSCORE (ES), elective, urgent or emergent surgery, isolated aortic valve, or isolated CABG) was performed. Procedure time, bypass time, x-clamp time, hospital stay, and early mortality were compared. RESULTS: After propensity score matching between surgeons of both sexes, patients operated by males (PoM) did not differ from patients operated by females (PoF) in mean age (PoM: 66.72 ± 9.33, PoF: 67.24 ± 9.19 years, p = 0.346), log. ES (PoM: 5.58 ± 7.35, PoF: 5.53 ± 7.26, p = 0.507), or urgency of operation (PoM: 43.09% elective, 48.97% urgent, 7.94% emergency, PoF: 40.88% elective, 55.29% urgent, 3.83% emergency, p = 0.556). This was also the case for male and female patients separately. Female surgeons had higher procedure time (PoM: 224.35 ± 110.54 min; PoF: 265.41 ± 53.60 min), bypass time (PoM: 107.46 ± 45.09 min, PoF: 122.42 ± 36.18 min), and x-clamp time (PoM: 61.45 ± 24.77 min; PoF: 72.76 ± 24.43 min). Hospitalization time (PoM: 15.96 ± 8.12, PoF: 15.98 ± 6.91 days, p = 0,172) as well as early mortality (PoM: 2.21%, PoF: 3.09%, p = 0.328) did not differ significantly. This was also the case for male and female patients separately. CONCLUSION: Our study reveals that in routine heart surgery, the gender of the surgeon does not impact the success of the operation or the early outcome of patients. Despite taking more time to perform procedures, female surgeons demonstrated comparable surgical outcomes to their male counterparts. It is possible that women's inclination for thoroughness contributes to the longer duration of procedures, while male surgeons may prioritize efficiency. Nevertheless, this difference in duration did not translate into significant differences in primary outcomes following routine cardiac surgery. These findings highlight the importance of recognizing the equal competence of female surgeons and dispelling biases regarding their surgical performance.

2.
Artículo en Inglés | MEDLINE | ID: mdl-37884029

RESUMEN

OBJECTIVE: Endocarditis as a potentially life-threatening disease with high complication and mortality rates. In recent years, an increase in the incident of endocarditis has been reported throughout Europe. In the aging society, successful treatment is complex and challenging owing to the high rate of multimorbidity. METHODS: We initiated a statewide prospective multicenter endocarditis registry in 2020. Perioperative risk factors, comorbidities, microbiological, laboratory and imaging diagnostics, complications, and mortality including 1-year follow-up were collected. The present midterm analysis includes factors influencing mortality in the first 313 patients. RESULT: In-hospital mortality and 1-year mortality were 28.4 and 40.9%, respectively. Preoperative risk factors include age (p < 0.001), EuroSCORE II (p < 0.001), coronary artery disease (p = 0.022), pacemaker probe infection (p = 0.033), preoperative left ventricular ejection fraction (LVEF), systemic inflammatory response syndrome (SIRS), pulmonary edema, heart failure, septic emboli, acute renal failure, impaired coagulation, hypalbuminemia (p < 0.001), and N-terminal prohormone of brain natriuretic peptide (NTproBNP) (p = 0.001). The presence of peri-annular abscess, perforation, and shunt were associated with increased mortality (p = 0.004, 0.001, and 0.004, respectively). In addition, cardiopulmonary bypass time influenced mortality (p = 0.002). The main postoperative causes of death were multi-organ failure, renal failure, vasoplegia, and low-output syndrome (p < 0.001). Previous endocarditis was 7.7%, while 35.5% were prosthetic valve recipients and 33.6% were redo surgeries. CONCLUSION: Our first registry data show the complexity of endocarditis patients and the challenging treatment. Some risk factors can be treated preoperatively. For instance, hypalbuminemia and the duration of the procedure can be controlled with adequate albumin substitution and carefully planned procedures restricted to the essential requirements, that is, hybrid approaches with consecutive interventions.

3.
Thorac Cardiovasc Surg ; 71(5): 366-375, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35144290

RESUMEN

OBJECTIVE: According to our nationwide registry, total numbers of surgical aortic valve implantation (sAVR) are constantly declining, while transcathether aortic valve implantation (TAVI) indications are widened toward intermediate- and low-risk patients. So, is there still room for conventionally implanted valves? Can results compete with TAVI or will sAVR be marginalized in the near future? METHODS: Between 2011 and 2019, 1,034 patients (67.1% male, mean = 72.2 years) were enrolled receiving stented biological valves with or without concomitant coronary artery bypass grafting (CABG), atrial ablation, or wrapping of the ascending aorta. Odds ratios for the early and late mortality were calculated regarding comorbidities as potential risk factors. Statistical analysis was performed using SPSS. RESULTS: Overall, early mortality (EM) was 6.1%, 1-year mortality was 11.2%, and 5-year mortality was 19.9%. In low-risk patients (EuroSCORE II <4%), it was 1.0, 2.7, and 9.3%. Incidence of EM was significantly increased following decompensation, prosthetic valve, pacemaker carrier, dialysis, and pulmonary hypertension. Postoperative complications, such as systemic inflammatory response syndrome (SIRS), sepsis, multiorgan failure, hepatic failure, dialysis, gastrointestinal bleeding, and ileus, also increased EM. Late mortality was significantly increased by dialysis, hepatic cirrhosis, infected port system, aortic valve endocarditis, prosthetic valve carrier, and chronic hemodialysis. CONCLUSION: Conventionally implanted aortic valves do well early and late. The fate of the patient is dependent on individual risk-factors. Particularly, in low-risk patients, sAVR can compete with TAVI showing overall good early, as well as late results being even superior in some important aspects such as pacemaker implantation rate. Thus, the time is yet not ripe for TAVI to take over primary indications for AVR in low-risk patient.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo
4.
Thorac Cardiovasc Surg ; 71(1): 12-21, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35785809

RESUMEN

BACKGROUND: Endocarditis is continuously increasing. Evidence exist that the prognosis is adversely affected by the extent of the disease. We looked at risk factors influencing in-hospital mortality (HM). PATIENTS AND METHODS: Between 2010 and 2019, 484 patients, 338 males (69.8%) with mean age of 66.1 years were operated on because of proven endocarditis. In a retrospective study, a risk factor analysis was performed. RESULTS: Overall HM was 30.17%. Significant influencing factors (odds ratios [ORs] or p-value) for HM were: age (p = 0.004), logistic EuroSCORE (p< 0.001), gender (OR = 1.64), dialysis (OR = 2.64), hepatic insufficiency (OR = 2.17), reoperation (OR = 1.77), previously implanted valve (OR = 1.97), periannular abscess (OR = 9.26), sepsis on admission (OR = 12.88), and number of involved valves (OR = 1.96). Development of a sepsis and HM was significantly lower if Streptococcus mitis was the main pathogen in contrast to other bacteria (p< 0.001). Staphylococcus aureus was significantly more often found in patients with a previously implanted prosthesis (p = 0.03) and in recurrent endocarditis (p = 0.02), while it significantly more often showed peripheral septic emboli than the other pathogens (p< 0.001). CONCLUSION: Endocarditis remains life-threatening. Severe comorbidities adversely affected early outcome, particularly, in presence of periannular abscesses. Patients with suspected endocarditis should be admitted to a specialized heart center as early as possible. Streptococcus mitis appears to be less virulent than S. aureus. Further studies are required to verify these findings.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Prótesis Valvulares Cardíacas , Infecciones Relacionadas con Prótesis , Sepsis , Masculino , Humanos , Anciano , Mortalidad Hospitalaria , Estudios Retrospectivos , Staphylococcus aureus , Resultado del Tratamiento , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Relacionadas con Prótesis/microbiología , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/cirugía , Endocarditis Bacteriana/microbiología , Factores de Riesgo , Prótesis Valvulares Cardíacas/efectos adversos , Endocarditis/etiología
5.
Medicina (Kaunas) ; 59(2)2023 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-36837420

RESUMEN

Objective: Cardiosurgical mitral valve repair (MVR) cannot be easily replaced by other interventional procedures due to the complexity of mitral valve regurgitation as well as physiologic and anatomic repair techniques. A wide variety of techniques have been adopted for proper reconstruction of posterior leaflet prolapse. We investigated the long-term results of quadrangular resections and compared them with a simplified reconstruction maneuver, the inverse plication. Methods: We retrospectively collected data from 1977 patients after mitral valve repair between 2004 and 2022. After considering inclusion and exclusion criteria, we analyzed data from 180 patients after MVR with and without concomitant procedures such as CABG and/or aortic valve replacement (AVR). All MVRs were performed with a semi-rigid annuloplasty ring. A total of 180 patients received quadrangular resection (QuadRes, N = 120)) or inverse plication (InvPlic, N = 60) of the posterior leaflet, among other measures. Demographic data, risk factors, procedure times, hospitalization time, early and long-term mortality as well as Kaplan-Meier survival were analyzed. Results: Age (65.3 vs. 63.1 years) and sex (28.8% female vs. 337.5% female) did not differ significantly, and the EuroSCORE was significantly higher in the InvPlic group (6.46 ± 2.75) than in the QuadRes group (5.68 ± 3.1). Procedural times did not differ for cardiopulmonary bypass, and were as follows: InvPlic 136 ± 44 min; QuadRes 140 ± 48 min; X-Clamp: InvPlic 91 ± 31 min; QuadRes 90 ± 32 min. Hospitalization time was slightly but insignificantly lower in the InvPlic group (15.5 days) than in the QuadRes group (16.1 days). Early mortality (5.08% vs. 8.33%) and re-do procedures (1.69% InvPlic; 6.67% QuadRes) did not differ significantly. However, long-term mortality was significantly lower in the InvPlic group (15.25% vs. 32.32%, p = 0.029). Conclusions: Among the surgical measures for the posterior leaflet, inverse plication appears to be non-inferior to quadrangular resection in unselected all-comer patients. Long-term results and absence of re-do procedures indicate very good stability. Thus, inverse plication not only allows correction of PML, but is also completely safe in the long term and can replace quadrangular resection, especially in patients where a reduction in technical challenges and procedure duration is desired.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Femenino , Masculino , Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Estudios Retrospectivos , Procedimientos Quirúrgicos Cardíacos/métodos , Resultado del Tratamiento
6.
Thorac Cardiovasc Surg ; 70(8): 637-644, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-33461219

RESUMEN

BACKGROUND: Atherosclerosis, hypertension, age, and fibrillopathies are well-known risk factors for the development of aortic aneurysm. We discovered that a significant proportion of our patients were previously on chemotherapy treatment or long-term treatment with cytostatic agents or immunosuppressive drugs. Thus, we examined this phenomenon. METHODS: A total of 224 patients with thoracic aorta aneurysm were retrospectively analyzed after aortic surgery from 2006 to 2016. Seventy-three patients received aortic wrapping and 151 patients underwent aortic replacement of which 89 had a valve-carrying conduit and 62 a supracoronary ascending replacement. Aortic morphology was assessed by means of compute tomography scan before and after surgery. Demographic data, risk profile, and postoperative complications were collected. Short- and long-term survival analysis was performed. Statistical analysis was performed with SPSS 19.0. RESULTS: Eighty-eight of 224 patients undergoing aortic surgery because of aortic aneurysm had previously or currently been treated with immunosuppressive agents. Dilatation of the ascending aorta was more pronounced in patients without such therapy. Demographic profile, intraoperative, as well as short- and long-term postoperative results did not differ significantly between both groups. CONCLUSION: The potential effect of immunosuppressant and cytostatic therapies on the development of an aortic aneurysm needs further study. Because of the astoundingly high proportion of these patients being found in an unselected aortic aneurysm cohort with immunosuppressive therapy in the past should be monitored for potential development of aortic aneurysm. If it occurs and requires treatment these patients can fortunately be operated upon with the same short- and long-term outcome than patients without such previous therapy.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Humanos , Inmunosupresores , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta/cirugía , Válvula Aórtica/cirugía , Aorta Torácica/cirugía
7.
Surg Technol Int ; 40: 119-123, 2022 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-35546495

RESUMEN

BACKGROUND: Patients undergoing pancreatic surgery are predominately very ill and therefore have a high potential for postoperative complications, which often has a life-limiting effect. As leakage of aggressive pancreatic secretions into the abdomen is one of the main reasons for an adverse outcome, measures to reduce it can be beneficial. Platelet-Rich Fibrin (PRF) is often used to seal areas that are already leaking or are susceptible to leakage at the end of the procedure. We sought to determine whether this positive intraoperative effect is associated with a positive postoperative outcome with regard to a reduction of complications. METHODS: We investigated 85 patients who underwent pancreatic surgery in our surgical department. All patients were treated intraoperatively with PRF in the surgical field. The occurrence of fistulas (biochemical leakage, post-operatic pancreatic fistula (POPF) grade B and POPF grade C). We compared our clinical data with patient data from the literature. RESULTS: The production of PRF from the patient's own blood is simple, safe, and not stressful for the patient. Complications related to production or use were not observed. Our patient group showed a lower fistula rate compared to those patient groups in the literature (POPF grade B and C: <13% vs. 16-72%). CONCLUSION: The results showed that use of PRF had a beneficial effect in patients undergoing pancreatic surgery, as reflected by a reduction in postsurgical fistula formation and better outcomes.


Asunto(s)
Pancreaticoduodenectomía , Fibrina Rica en Plaquetas , Humanos , Páncreas/cirugía , Fístula Pancreática/epidemiología , Fístula Pancreática/etiología , Fístula Pancreática/prevención & control , Pancreaticoduodenectomía/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Estudios Retrospectivos , Factores de Riesgo
8.
Medicina (Kaunas) ; 58(8)2022 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-36013522

RESUMEN

Background and Objectives: Friable or infected tissue remains a challenge in surgical aortic valve replacement. We recently described the "Caput medusae" method, in which circumferential tourniquets temporarily secure the prosthesis and are then gently knotted. Tourniquets have been shown to develop significantly less force than knots. The current study investigates the critical threshold forces for tissue damage to the aortic annulus. Materials and Methods: In 14 fresh porcine hearts, the aortic valve leaflets were removed and several pledgeted sutures were placed along the annulus at defined locations. The hearts were mounted in a self-constructed device. Incremental traction force was applied to every suture and continuously recorded. The movement of each Teflon pledget was filmed with a high-speed camera. Forces at the moment of pledget "cut-in" as well as complete "tear-out" were determined from the recordings. Results: The average threshold force was determined 9.31 ± 6.04 N for cut-in and 20.41 ± 10.02 N for tear-out. Detailed analysis showed that the right coronary region had lower threshold forces than the other regions (4.77 ± 3.28 N (range, 1.67-12.75 N) vs. 10.67 ± 6.04 N (1.62-26.00 N) for cut-in and 10.67 ± 4.04 N (5.40-18.64 N) vs. 23.33 ± 9.42 N (9.22-51.23 N) for tear-out). The findings are discussed in conjunction with the knot and tourniquet forces from our previous study. Conclusions: Even in healthy tissue, moderate forces can reach a critical level at which a Teflon pledget will cut into the annulus, while a complete tear-out is unlikely. The right coronary portion is more susceptible to damage than the remaining regions. When compared to previous data, forces during manual knotting may exceed the critical cut-in level, while rubber tourniquets may provide a higher safety margin against tissue rupture.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Animales , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Politetrafluoroetileno , Técnicas de Sutura , Porcinos , Tracción
9.
Medicina (Kaunas) ; 58(9)2022 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-36143897

RESUMEN

Background and Objectives: Increasing reluctance to perform surgical mitral valve repair or replacement particularly in high-risk patients with poor left-ventricular function is trending. These patients are increasingly treated interventionally, e.g., by MitraClip, but often show only low to moderate improvement. The primary objective of the study was to investigate whether left ventricular ejection fraction (LVEF) influences postoperative mortality. Materials and Methods: The study included 903 patients undergoing mitral valve repair or replacement between 2009 and 2021. Statistical comparison was performed between patients with LVEF ≤ 30% and LVEF > 30%. Finally, statistical analysis was performed according to propensity score matching (1:3 PS matching). Results: No significant difference in in-hospital mortality was found before and after matching regarding LVEF ≤ 30% and LVEF > 30% (Pre: 10.8% vs. 15.1%, p = 0.241, after: 11.6% vs. 18.1%, p = 0.142). After PS matching, the 112 patients with LVEF ≤ 30% compared with 336 patients with LVEF > 30% showed a significantly higher preoperative NT-proBNP (p < 0.001), larger diameters at preoperative left ventricle and atrium (p < 0.001), lower preoperative TAPSE (p = 0.003) and PAP (p = 0.003), and more dilated cardiomyopathy and chronic kidney disease (p < 0.001, p = 0.045). Conclusions: The results of this study demonstrate that poor preoperative LVEF alone does not play a significant role in postoperative outcome and long-term mortality. Prognosis appears to be multifactorial. Poor preoperative LVEF is not a contraindication for surgery and does not justify primary interventional treatment accepting inferior hemodynamic results impeding outcome.


Asunto(s)
Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/cirugía , Función Ventricular Izquierda
10.
Medicina (Kaunas) ; 58(11)2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36422234

RESUMEN

Background and Objectives: Developing a prosthetic heart valve that combines the advantageous hemodynamic properties of its biological counterpart with the longevity of mechanical prostheses has been a major challenge for heart valve development. Anatomically inspired artificial polymeric heart valves have the potential to combine these beneficial properties, and innovations in 3D printing have given us the opportunity to rapidly test silicone prototypes of new designs to further the understanding of biophysical properties of artificial heart valves. TRISKELION is a promising prototype that we have developed, tested, and further improved in our institution. Materials and Methods: STL files of our prototypes were designed with FreeCad 0.19.2 and 3D printed with an Agilista 3200W (Keyence, Osaka, Japan) using silicones of Shore hardness 35 or 65. Depending on the valve type, the support structures were printed in AR-M2 plastics. The prototypes were then tested using a hemodynamic pulse duplicator (HKP 2.0) simulating an aortic valve cycle at 70 bpm with 70 mL stroke volume (cardiac output 4.9 L/min). Valve opening cycles were visualized with a high-speed camera (Phantom Miro C320). The resulting values led to further improvements of the prototype (TRISKELION) and were compared to a standard bioprosthesis (Edwards Perimount 23 mm) and a mechanical valve (Bileaflet valve, St. Jude Medical). Results: We improved the silicone prototype with currently used biological and mechanical valves measured in our setup as benchmarks. The regurgitation fractions were 22.26% ± 4.34% (TRISKELION) compared to 8.55% ± 0.22% (biological) and 13.23% ± 0.79% (mechanical). The mean systolic pressure gradient was 9.93 ± 3.22 mmHg (TRISKELION), 8.18 ± 0.65 mmHg (biological), and 10.15 ± 0.16 mmHg (mechanical). The cardiac output per minute was at 3.80 ± 0.21 L/min (TRISKELION), 4.46 ± 0.01 L/min (biological), and 4.21 ± 0.05 L/min (mechanical). Conclusions: The development of a heart valve with a central structure proves to be a promising concept. It offers another principle to address the problem of longevity in currently used heart valves. Using 3D printing to develop new prototypes provides a fast, effective, and accurate way to deepen understanding of its physical properties and requirements. This opens the door for translating and combining results into modern prototypes using highly biocompatible polymers, internal structures, and advanced valve layouts.


Asunto(s)
Prótesis Valvulares Cardíacas , Válvulas Cardíacas , Humanos , Impresión Tridimensional , Polímeros , Siliconas
11.
Artif Organs ; 45(5): E79-E88, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33084066

RESUMEN

Extracorporeal circulation (ECC) is an integral part of cardiac surgery. Yet, the contact with artificial surfaces, mechanical stress, shear, and suction forces within the ECC pose a pronounced risk for damaging the corpuscular components of the blood. These suction forces may be reduced by a repositioning of the roller pumps employed below the reservoir. Furthermore, the repeated compression of the involved silicone tubing is likely to cause degradation. We present our observations regarding changes in the ECC performance following this degradation process. In vitro experiments were performed in a standard as well as a simplified ECC setup and included measurements of pressure, effective flow, and tubing restoring force over a time frame of 12 hours with two different pump positions utilizing transit time flow measurement. Suction forces within the tubing could be significantly reduced by shifting the pump position below the reservoir. Regardless of the setup, the tubing showed significant loss of restoring force as well as effective flow over time. A shift of the pump position within the ECC setup can be recommended to prevent blood damaging negative pressures. Further research is necessary to evaluate the exact cause of the reduction of restoring force overtime as well as its risks for the patients. Finally, our results underline the importance of transit time flow measurements to collect reliable flow data.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Circulación Extracorporea/instrumentación , Estrés Mecánico , Hidrodinámica , Presión/efectos adversos , Resistencia al Corte , Vacio
12.
Thorac Cardiovasc Surg ; 69(1): 43-48, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-31858496

RESUMEN

BACKGROUND: Polymeric heart valves are constructed from flexible synthetic materials, therefore aiming to combine the advantageous hemodynamic of biological and the longevity of mechanical valve prostheses. One such valve prototype in development is the PIZZA valve constructed of flexible triangular silicone leaflets on a foldable metal base for perspective transcatheter implantation. Here we present further improvements in its performance through structural modifications. METHODS: Structurally modified prototypes were constructed from silicone sheets and stainless-steel wires. Their performance was then tested in a hemodynamic testing device of the type HKP 2.0. RESULTS: Shift from a planar to a cone shape as well as overlapping of the leaflets significantly improved the valves performance, reducing regurgitation as well as systolic pressure gradients. CONCLUSIONS: The results of the modified prototypes expressed superior performance and represented a step forward on the road to an easily producible, polymeric transcatheter valvular prosthesis.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Válvulas Cardíacas/cirugía , Siliconas , Acero Inoxidable , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvulas Cardíacas/fisiopatología , Hemodinámica , Humanos , Ensayo de Materiales , Diseño de Prótesis , Estrés Mecánico
13.
Surg Technol Int ; 39: 313-316, 2021 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-34736287

RESUMEN

OBJECTIVE: Disturbed wound healing is a significant problem in patients after cardiac surgery. Problems with deep sternal wound healing are rare, but can be quite difficult to treat. Furthermore, the therapy is highly expensive and consumes many of the patient's personal resources. Another major obstacle in this patient group is reinfection after secondary wound closure. We examined how to prevent early reinfection through the use of growth factors in combination with local antibiotics. METHODS: Our study included 232 patients with a deep sternal wound healing problem. After initial vacuum therapy, we planned secondary wound closure. During wound closure, we used only platelet-rich fibrin in a PRF group (109 patients). In another group (123 patients), we covered the wounds intraoperatively with a combination of PRF and local antibiotics (PRF CoDelivery). All patients were observed for 30 days for signs of early surgical site infection. RESULTS: After 30 days, 22 patients (20.2%) in the PRF group showed a persistent problem with wound healing with or without reinfection. In contrast, only 12 patients (9.8%) in the PRF CoDelivery group had this problem (p=0.023 PRF vs. PRF CoDelivery). CONCLUSION: The combination of growth factors and antibiotics was associated with a significantly reduced incidence of early reinfection and thus can be expected to have a positive impact on wound healing in complicated scenarios. Furthermore, the combination of PRF and local antibiotics was easy to use. Further studies are needed to verify these initial findings.


Asunto(s)
Fibrina Rica en Plaquetas , Antibacterianos/uso terapéutico , Humanos , Reinfección , Infección de la Herida Quirúrgica/tratamiento farmacológico , Infección de la Herida Quirúrgica/prevención & control , Cicatrización de Heridas
14.
Thorac Cardiovasc Surg ; 68(4): 322-327, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31747695

RESUMEN

BACKGROUND: Prosthetic replacement of aneurysms of the ascending aorta is the gold standard in terms of long-term stability. Wrapping seems to be a less invasive procedure. It has not yet been shown if it is as safe in terms of long-term outcome. METHODS: We present a single-center analysis of our experience over 13 years. We retrospectively analyzed data from patients who received either aortic prosthetic wrapping (AW) or aortic prosthetic replacement (AR) with or without aortic valve replacement and assessed them through phone calls. We used propensity score matching to adjust the baseline of the groups. RESULTS: Before propensity matching, 144 patients received AW and 91 patients underwent AR. Mean age was 64 ± 11.8 years. After propensity score matching and adjusting for significant differences in age, gender, body mass index, logistic EuroSCORE I, and left ventricular function, 69 patients in each group remained for further analysis. Rate of early reoperation due to tamponade, inhospital mortality, and survival rates did not differ. In both groups, the surgically treated aortic segment did not show enlargement, whereas the nontreated aortic arch showed comparable aneurysmatical progression. CONCLUSIONS: AW is safe and feasible and can be used in elderly or frail patients in order to avoid an AR. Progression of the remaining native aortic segments occurs, thus requiring strict life-long follow-up to ensure an elective and thus safe approach for appropriate consecutive surgical measures, if required.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Quirúrgicos Vasculares , Anciano , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
15.
Thorac Cardiovasc Surg ; 68(7): 557-566, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-30669172

RESUMEN

BACKGROUND: Conventional stented valves (CV) remain gold standard for aortic valve disease. Bovine prostheses have been improved and rapid deployment valves (RDV) have arrived in the recent decade. We compare clinical and hemodynamic short-term outcome of six bovine valves. METHODS: We retrospectively evaluated 829 consecutive patients (all-comers) receiving bovine aortic valve replacement (AVR). Four CV from different manufacturers (Mitroflow, Crown, Perimount, Trifecta) and two RDV (Perceval, Intuity) were compared in terms of pre-, intra-, and postprocedural data. A risk model for mortality was created. RESULTS: All valves reduced gradients. From 23 mm, all CV showed acceptable gradients. Twenty-one millimeter Mitroflow/Perceval and 19 mm Crown showed above-average gradients. As baseline data differed, we performed propensity matching between aggregated isolated CV and RDV groups. Cardiopulmonary bypass (CPB), clamp, and surgery times were shorter with RDV (87.4 ± 34.0 min vs 111.0 ± 34.2, 54.3 ± 21.1 vs 74.9 ± 20.4, 155.2 ± 42.9 vs 178.0 ± 46.8, p < 0.001). New pacemaker rate (10.1 vs 1.3%, p = 0.016) and the tendency toward neurologic events (8.9 vs 2.5%, p = 0.086) were higher using RDV, induced mainly by the Perceval. Early mortality was equal (2.5 vs 1.3%, p = 0.560). Revision for bleeding, dialysis, blood products, length-of-stay, gradients, and regurgitation was also equal. Risk analysis showed that low valve size, low ejection fraction, endocarditis, administration of red cells, and prolonged CPB time were predictors of elevated mortality. CONCLUSION: Isolated bovine AVR has low mortality. Valves ≥ 23 mm show comparable gradients while the valve model matters < 23 mm. RDV should be used with care. Procedure-related times are shorter than those of CV but pacemaker implantation and neurologic events are more frequent (Perceval). Early mortality is low and valve performance comparable to CV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Hemodinámica , Anciano , Animales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Bovinos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
16.
Thorac Cardiovasc Surg ; 67(4): 257-265, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29739020

RESUMEN

BACKGROUND: Transcatheter heart valve (THV) as valve-in-ring is increasingly used in the mitral position. Semi-rigid rings may serve as a more appropriate scaffold for proper anchoring of a THV as they may change from their oval to a round shape thereby fitting to the implanted THV. METHODS: One rigid and five semi-rigid rings of four manufacturers, Edwards Physio I and II, Sorin 3D Memo, Medtronic Simulus, and St. Jude Medical (SJM) Saddle and SJM Sequin, with sizes 28 to 36 mm and Edwards Sapien III THV 23, 26, and 29 mm were used. Preevaluation comprised insertion/inflation of the THV into the ring and visual inspection for the paravalvular gap ≥ 4 mm2. Only valves not showing paravalvular gap were then submitted to hemodynamic evaluation with a pulse duplicator. Cusp movement was assessed with a high-speed-camera. Mean transvalvular gradients (TVGs) were measured. RESULTS: SJM Saddle ring of all sizes and SJM Sequin ring 34 showed marked gaps combined with all THV sizes, thus not undergoing hemodynamic testing. It was further shown that ring sizes ≥ 36 mm did not allow for a proper fit of even the largest THV into the ring of all the manufacturers and were consequently not hemodynamically evaluated. The 23 mm THV was too small for any ring size. The lowest gradients were achieved with the 26 mm THV in 30 and 32 mm and the 29 mm THV in 32 and 34 mm rings. CONCLUSION: Not all currently available annuloplasty rings are ideal scaffolds for THV placement. It appears that a more proper fit can be achieved with semi-rigid rings than with rigid ones. Note that 23 mm THV appeared to be too small for an adequate anchoring in even the smallest available ring. Thus, 26 mm as well as 29 mm THV fit properly in ring sizes between 28 and 34 mm. Surgeons may consider to choose from those ring brands and sizes which allow for good placement of a THV in view of possible valve degeneration in the later course.


Asunto(s)
Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral/instrumentación , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Hemodinámica , Ensayo de Materiales , Anuloplastia de la Válvula Mitral/efectos adversos , Falla de Prótesis , Estrés Mecánico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
Thorac Cardiovasc Surg ; 67(8): 616-623, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31042804

RESUMEN

BACKGROUND: Endocarditis remains one of the most threatening diagnoses in cardiac surgery and is still increasing. Particularly, device-related as well as prosthetic endocarditis appears to be on the rise. Early mortality and periprocedural complications are high jeopardizing the success of surgical efforts. We looked at the development of the numbers and the distribution of endocarditis in an all-comer analysis. METHODS: From 2003 to 2017, 752 patients with endocarditis were transferred to our cardiosurgical institution (mean age 65 ± 13 years; mean logistic EuroSCORE 28.01%; males 74.33%). A total of 89.49% of them were surgically treated; 30.01% redo cases thereof; and 9.17% had been operated previously for acute endocarditis. RESULTS: While the total number of cardiosurgical procedures remained relatively stable throughout the years, 20 patients were admitted in 2003 and 79 in 2017 yielding more than fourfold increase (p < 0.001). Early mortality of all patients was 25.1%. Septic emboli occurred in 23.7% and 43.8% cerebral emboli thereof. A significant increase of aortic, mitral, and tricuspid valves involvement was observed (p < 0.001). An increase of device-related endocarditis was also noted (p < 0.001). CONCLUSION: Endocarditis remains a serious problem with high early mortality and morbidity. The vast increase of electrophysiological device implantations has resulted in an increase of tricuspid valve involvement. Liberalization of endocarditis prophylaxis, that is, more restrictive use of antibiotics in 2007 may have at least partially contributed to an increase of the individual risk to suffer from acute endocarditis. A renaissance of a stricter endocarditis-prophylaxis may thus be considered.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Infecciones Relacionadas con Catéteres/cirugía , Endocarditis Bacteriana/cirugía , Infecciones Relacionadas con Prótesis/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Profilaxis Antibiótica , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Infecciones Relacionadas con Catéteres/diagnóstico , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/mortalidad , Desfibriladores Implantables/efectos adversos , Farmacorresistencia Bacteriana Múltiple , Endocarditis Bacteriana/diagnóstico , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/mortalidad , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/mortalidad , Reoperación , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
Thorac Cardiovasc Surg ; 66(7): 537-544, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-28922672

RESUMEN

BACKGROUND: MitraClip (Abbott Inc.) is propagated as a palliative option for high-risk patients with mitral insufficiency considered not qualifying for surgical repair. A proportion of patients requires consecutive surgery because of technical failure or inappropriate clinical improvement. Furthermore, surgical reconstruction is impossible in almost all patients after MitraClip implantation. Consequently, these patients receive replacement although primary repair may have been possible. The outcome of those patients compared with patients receiving primary mitral valve replacement (MVR) or mitral valve repair (MVP) was analyzed. METHODS: A total of 23 patients were retrospectively analyzed after MVR following MitraClip. Overall, 46 patients with corresponding demographic data and risk profile receiving primary MVR (23 patients) or MVP (23 patients) were retrieved for matched pair analysis. RESULTS: Mean age was 70 years in all groups, log European system for cardiac operative risk evaluation (EuroSCORE) was 22.47% ± 16.30 in MVR after MitraClip (MC), 22.34% ± 16.23 in MVP, and 22.33% ± 16.14 in MVR group. Preoperative left ventricular ejection fraction (LVEF) was 44%, and postoperative LVEF was 48% in all groups. The 30-day mortality was 21.7% in the MitraClip group whereas it was 4.3% in the MVR and 13.0% in the MVP group. The 1-year survival was 56.5% in the MitraClip group while it was 95.6% in the MVR group and 82.6% in the MVP group (Wilcoxon test: p = 0.007; chi-square test: p = 0.001 MitraClip vs. MVR; p = 0.054 MitraClip vs. MVP). CONCLUSIONS: Patients requiring surgical MVR after the previous MitraClip fared worse than matched cohorts receiving primary MVR or MVP. Indication for MitraClip should, therefore, be made very cautiously given the excellent results gained with primary surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Toma de Decisiones Clínicas , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Cuidados Paliativos , Anciano , Anciano de 80 o más Años , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/mortalidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Selección de Paciente , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
19.
Thorac Cardiovasc Surg Rep ; 12(1): e44-e47, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37434778

RESUMEN

Background Prosthetic valve endocarditis is becoming more common because many patients live long enough to experience bacteremia, while insufficient antibiotic prophylaxis eventually leads to graft infection. Valve-bearing conduit infections are the most feared because of technical challenges. Case Description Two young patients were coincidental twins in terms of diagnosis and therapy. Both underwent complete replacement of the conduit, aortic arch prosthesis, and additional strategies to reconnect the coronary ostia and the brachiocephalic trunk. Both were discharged without significant residual problems. Conclusion Even most demanding infectious problems can be solved. Thus, surgery should not be denied.

20.
J Clin Med ; 12(15)2023 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-37568512

RESUMEN

BACKGROUND AND OBJECTIVES: Jehovah's Witnesses (JW) reject the transfusion of blood components based on their religious beliefs, even if they are in danger of harm or death. In cardiac surgery, this significantly reduces the margin of safety and leads to ethical conflicts. Informed consent should be carefully documented and the patient's family should be involved. This study aims to compare the postoperative course of JW who underwent major cardiac surgery with a similar population of non-Witnesses (NW). PATIENTS AND METHODS: Demographic, procedural, and postoperative data of all consecutive JW who underwent cardiac surgery at our institution were obtained from the records. They were compared with a propensity-score-matched group of NW. Anemic JW were treated with erythropoietin and/or iron as needed. Cardiac surgery was performed by experienced surgeons using median sternotomy and cardiopulmonary bypass. Common blood-sparing techniques were routinely used. Periprocedural morbidity and mortality were statistically evaluated for both groups. RESULTS: A total of 32 JW and 64 NW were part of the matched dataset, showing no demographic or procedural differences. EPO was used preoperatively in 34.4% and postoperatively in 15.6% of JW but not in NW. Preoperative hemoglobin levels were similar (JW, 8.09 ± 0.99 mmol/L; NW, 8.18 ± 1.06; p = 0.683). JW did not receive any transfusions except for one who revoked, while NW transfusion rates were 2.5 ± 3.1 units for red cells (p < 0.001) and 0.3 ± 0.8 for platelets (p = 0.018). Postoperative levels differed significantly for hemoglobin (JW, 6.05 ± 1.00 mmol/L; NW, 6.88 ± 0.87; p < 0.001), and hematocrit (JW, 0.29 ± 0.04; NW, 0.33 ± 0.04; p < 0.001) but not for creatinine. Early mortality was similar (JW, 6.3%; NW, 4.7%; p = 0.745). There were more pacemakers and pneumonias in JW, while all other postoperative conditions were not different. CONCLUSIONS: Real-world data indicate that Jehovah's Witnesses can safely undergo cardiac surgery provided that patients are preconditioned and treated by experienced surgeons who use blood-saving strategies. Postoperative anemia is observed but does not translate into a worse clinical outcome. This is consistent with other studies. Finally, the results of this study suggest that all patients should benefit from optimal pretreatment and blood-sparing strategies in cardiac surgery, not just Jehovah's Witnesses.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA