Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Mikrochim Acta ; 187(5): 288, 2020 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-32333119

RESUMEN

A label-free biosensor is developed for the determination of plasma-based Aß1-42 biomarker in Alzheimer's disease (AD). The platform is based on highly conductive dual-layer of graphene and electrochemically reduced graphene oxide (rGO). The modification of dual-layer with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) is achieved to facilitate immobilization of H31L21 antibody. The effect of these modifications were studied with morphological, spectral and electrochemical techniques. The response of the biosensor was evaluated using differential pulse voltammetry (DPV). The data was acquired at a working potential of ~ 180 mV and a scan rate of 50 mV s-1. A low limit of detection (LOD) of 2.398 pM is achieved over a wide linear range from 11 pM to 55 nM. The biosensor exhibits excellent specificity over Aß1-40 and ApoE ε4 interfering species. Thus, it provides a viable tool for electrochemical determination of Aß1-42. Spiked human and mice plasmas were used for the successful validation of the sensing platform in bio-fluidic samples. The results obtained from mice plasma analysis concurred with the immunohistochemistry (IHC) and magnetic resonance imaging (MRI) data obtained from brain analysis. Graphical abstract Schematic representation of the electrochemical system proposed for Aß1-42 determination: (a) modification of graphene screen-printed electrode (SPE) with monolayer graphene oxide (GO) followed by its electrochemical reduction generating graphene/reduced graphene oxide (rGO) dual-layer (b), modification of dual-layer with linker (c), Aß1-42 antibody (H31L21) (d), bovine serum albumin (BSA) (e) and Aß1-42 peptide (f).


Asunto(s)
Péptidos beta-Amiloides/sangre , Técnicas Biosensibles , Técnicas Electroquímicas , Grafito/química , Fragmentos de Péptidos/sangre , Animales , Biomarcadores/sangre , Humanos , Ratones , Estructura Molecular , Oxidación-Reducción
2.
Mikrochim Acta ; 187(6): 338, 2020 05 20.
Artículo en Inglés | MEDLINE | ID: mdl-32430539

RESUMEN

The published version of this article, unfortunately, contains errors. Corrections in references were incorrectly carried out. Also, the reduction of graphene oxide was carried out between the potential of -1.5 and 0.5 V, instead of 0.5 and 1.5 V.

3.
Sensors (Basel) ; 18(1)2018 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-29361679

RESUMEN

Clusterin (CLU) has been associated with the clinical progression of Alzheimer's disease (AD) and described as a potential AD biomarker in blood plasma. Due to the enormous attention given to cerebrospinal fluid (CSF) biomarkers for the past couple of decades, recently found blood-based AD biomarkers like CLU have not yet been reported for biosensors. Herein, we report the electrochemical detection of CLU for the first time using a screen-printed carbon electrode (SPCE) modified with 1-pyrenebutyric acid N-hydroxysuccinimide ester (Pyr-NHS) and decorated with specific anti-CLU antibody fragments. This bifunctional linker molecule contains succinylimide ester to bind protein at one end while its pyrene moiety attaches to the carbon surface by means of π-π stacking. Cyclic voltammetric and square wave voltammetric studies showed the limit of detection down to 1 pg/mL and a linear concentration range of 1-100 pg/mL with good sensitivity. Detection of CLU in spiked human plasma was demonstrated with satisfactory recovery percentages to that of the calibration data. The proposed method facilitates the cost-effective and viable production of label-free point-of-care devices for the clinical diagnosis of AD.


Asunto(s)
Clusterina/análisis , Enfermedad de Alzheimer , Biomarcadores , Técnicas Biosensibles , Electrodos , Humanos , Límite de Detección , Pirenos
4.
Biosensors (Basel) ; 12(2)2022 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-35200358

RESUMEN

The ability to detect double-stranded DNA (dsDNA) as a biomarker without denaturing it to single-stranded DNA (ss-DNA) continues to be a major challenge. In this work, we report a sandwich biosensor for the detection of the ds-methylated MGMT gene, a potential biomarker for brain tumors and breast cancer. The purpose of this biosensor is to achieve simultaneous recognition of the gene sequence, as well as the presence of methylation. The biosensor is based on reduced graphene oxide (rGO) electrodes decorated with gold nanoparticles (AuNPs) and uses Peptide Nucleic Acid (PNA) that binds to the ds-MGMT gene. The reduction of GO was performed in two ways: electrochemically (ErGO) and thermally (TrGO). XPS and Raman spectroscopy, as well as voltammetry techniques, showed that the ErGO was more efficiently reduced, had a higher C/O ratio, showed a smaller crystallite size of the sp2 lattice, and was more stable during measurement. It was also revealed that the electro-deposition of the AuNPs was more successful on the ErGO surface due to the higher At% of Au on the ErGO electrode. Therefore, the ErGO/AuNPs electrode was used to develop biosensors to detect the ds-MGMT gene. PNA, which acts as a bio-recognition element, was used to form a self-assembled monolayer (SAM) on the ErGO/AuNPs surface via the amine-AuNPs interaction, recognizing the ds-MGMT gene sequence by its invasion of the double-stranded DNA and the formation of a triple helix. The methylation was then detected using biotinylated-anti-5mC, which was then measured using the amperometric technique. The selectivity study showed that the proposed biosensor was able to distinguish between blank, non-methylated, non-complementary, and target dsDNA spiked in mouse plasma. The LOD was calculated to be 0.86 pM with a wide linear range of 1 pM to 50 µM. To the best of our knowledge, this is the first report on using PNA to detect ds-methylated DNA. This sandwich design can be modified to detect other methylated genes, making it a promising platform to detect ds-methylated biomarkers.


Asunto(s)
Técnicas Biosensibles , Grafito , Nanopartículas del Metal , Ácidos Nucleicos de Péptidos , Animales , Biomarcadores , Técnicas Biosensibles/métodos , ADN/química , Técnicas Electroquímicas/métodos , Electrodos , Oro , Grafito/química , Nanopartículas del Metal/química , Ratones
5.
Nanomaterials (Basel) ; 11(4)2021 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-33921234

RESUMEN

In this work, we developed a sandwich DNA-immunosensor for quantification of the methylated tumour suppressor gene O-6-methylguanine-DNA methyltransferase (MGMT), which is a potential biomarker for brain tumours and breast cancer. The biosensor is based on aminated reduced graphene oxide electrode, which is achieved by ammonium hydroxide chemisorption and anti-5-methylcytosine (anti-5mC) as a methylation bioreceptor. The target single-strand (ss) MGMT oligonucleotide is first recognised by its hybridisation with complementary DNA to form double-stranded (ds) MGMT, which is then captured by anti-5mC on the electrode surface due to the presence of methylation. Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and Scanning electron microscopy (SEM) techniques were used to characterise the electrode surface. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were used for electrochemical measurements. Under optimised conditions, the proposed biosensor is able to quantify a linear range of concentrations of the MGMT gene from 50 fM to 100 pM with a limit of detection (LOD) of 12 fM. The sandwich design facilitates the simultaneous recognition and quantification of DNA methylation, and the amination significantly improves the sensitivity of the biosensor. This biosensor is label-, bisulfite- and PCR-free and has a simple design for cost-efficient production. It can also be tailor-made to detect other methylated genes, which makes it a promising detection platform for DNA methylation-related disease diagnosis and prognosis.

6.
Sci Rep ; 8(1): 17394, 2018 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-30478411

RESUMEN

Revealing the relationship between dysfunctional genes in blood and brain tissues from patients with Alzheimer's Disease (AD) will help us to understand the pathology of this disease. In this study, we conducted the first such large systematic analysis to identify differentially expressed genes (DEGs) in blood samples from 245 AD cases, 143 mild cognitive impairment (MCI) cases, and 182 healthy control subjects, and then compare these with DEGs in brain samples. We evaluated our findings using two independent AD blood datasets and performed a gene-based genome-wide association study to identify potential novel risk genes. We identified 789 and 998 DEGs common to both blood and brain of AD and MCI subjects respectively, over 77% of which had the same regulation directions across tissues and disease status, including the known ABCA7, and the novel TYK2 and TCIRG1. A machine learning classification model containing NDUFA1, MRPL51, and RPL36AL, implicating mitochondrial and ribosomal function, was discovered which discriminated between AD patients and controls with 85.9% of area under the curve and 78.1% accuracy (sensitivity = 77.6%, specificity = 78.9%). Moreover, our findings strongly suggest that mitochondrial dysfunction, NF-κB signalling and iNOS signalling are important dysregulated pathways in AD pathogenesis.


Asunto(s)
Enfermedad de Alzheimer/genética , Biomarcadores/sangre , Biomarcadores/metabolismo , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/metabolismo , Sangre/metabolismo , Encéfalo/metabolismo , Estudios de Casos y Controles , Disfunción Cognitiva/sangre , Disfunción Cognitiva/genética , Disfunción Cognitiva/metabolismo , Estudio de Asociación del Genoma Completo , Humanos , Aprendizaje Automático , Mitocondrias/genética , FN-kappa B/genética , Óxido Nítrico Sintasa de Tipo II/genética , Ribosomas/genética , Sensibilidad y Especificidad , Transducción de Señal/genética
7.
Biosensors (Basel) ; 7(3)2017 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-28704926

RESUMEN

We report on a label-free immunosensor based on graphene field effect transistors (G-FETs) for the ultrasensitive detection of Human Chorionic Gonadotrophin (hCG), as an indicator of pregnancy and related disorders, such as actopic pregnancy, choriocarcinoma and orchic teratoma. Pyrene based bioactive ester was non-covalently anchored onto the graphene channel in order to retain the sp² lattice. The G-FET transfer characteristics showed repeatable and reliable responses in all surface modifying steps using a direct current (DC) readout system. The hCG concentration gradient showed a detection limit of ~1 pg·mL-1. The proposed method facilitates the cost-effective and viable production of graphene point-of-care devices for clinical diagnosis.


Asunto(s)
Técnicas Biosensibles , Gonadotropina Coriónica/aislamiento & purificación , Grafito/química , Femenino , Oro/química , Humanos , Embarazo , Transistores Electrónicos
8.
Dis Markers ; 2016: 4250480, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27418712

RESUMEN

Blood-based biomarkers for Alzheimer's disease would be very valuable because blood is a more accessible biofluid and is suitable for repeated sampling. However, currently there are no robust and reliable blood-based biomarkers for practical diagnosis. In this study we used a knowledge-based protein feature pool and two novel support vector machine embedded feature selection methods to find panels consisting of two and three biomarkers. We validated these biomarker sets using another serum cohort and an RNA profile cohort from the brain. Our panels included the proteins ECH1, NHLRC2, HOXB7, FN1, ERBB2, and SLC6A13 and demonstrated promising sensitivity (>87%), specificity (>91%), and accuracy (>89%).


Asunto(s)
Enfermedad de Alzheimer/sangre , Proteoma/análisis , Biomarcadores/sangre , Encéfalo/metabolismo , Isomerasas de Doble Vínculo Carbono-Carbono/genética , Isomerasas de Doble Vínculo Carbono-Carbono/metabolismo , Fibronectinas/genética , Fibronectinas/metabolismo , Proteínas Transportadoras de GABA en la Membrana Plasmática/genética , Proteínas Transportadoras de GABA en la Membrana Plasmática/metabolismo , Proteínas de Homeodominio/genética , Proteínas de Homeodominio/metabolismo , Humanos , Bases del Conocimiento , ARN Mensajero/genética , ARN Mensajero/metabolismo , Receptor ErbB-2/genética , Receptor ErbB-2/metabolismo , Sensibilidad y Especificidad , Transcriptoma
9.
Biosens Bioelectron ; 72: 313-9, 2015 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-26002015

RESUMEN

A novel printed graphene electrode modified with electrochemically reduced graphene oxide was developed for the detection of a specific oligonucleotide sequence. The graphene oxide was immobilized onto the surface of a graphene electrode via π-π bonds and electrochemical reduction of graphene oxide was achieved by cyclic voltammetry. A much higher redox current was observed from the reduced graphene oxide-graphene double-layer electrode, a 42% and 36.7% increase, respectively, in comparison with that of a bare printed graphene or reduced graphene oxide electrode. The good electron transfer activity is attributed to a combination of the large number of electroactive sites in reduced graphene oxide and the high conductivity nature of graphene. The probe ssDNA was further immobilized onto the surface of the reduced graphene oxide-graphene double-layer electrode via π-π bonds and then hybridized with its target cDNA. The change of peak current due to the hybridized dsDNA could be used for quantitative sensing of DNA concentration. It has been demonstrated that a linear range from 10(-7)M to 10(-12)M is achievable for the detection of human immunodeficiency virus 1 gene with a detection limit of 1.58 × 10(-13)M as determined by three times standard deviation of zero DNA concentration.


Asunto(s)
ADN/análisis , Técnicas Electroquímicas/instrumentación , Grafito/química , Óxidos/química , Técnicas Biosensibles/instrumentación , Sondas de ADN/química , ADN de Cadena Simple/química , Electrodos , Genes Virales , Infecciones por VIH/virología , VIH-1/genética , Humanos , Ácidos Nucleicos Inmovilizados/química , Límite de Detección , Hibridación de Ácido Nucleico , Oxidación-Reducción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA