Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Am J Ophthalmol Case Rep ; 35: 102072, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38841152

RESUMEN

Purpose: To evaluate outcomes of slow coagulation transscleral cyclophotocoagulation (SC-TSCPC) in a primarily African American patient population with glaucoma. Methods: A retrospective chart review was performed for 104 consecutive cases of SC-TSCPC by a single surgeon between November 6, 2019-September 7, 2023. Power ranged from 1150 to 1500 mW, duration was 4 s, and number of spots ranged from 10 to 25. Exclusion criteria were diagnosis of neovascular glaucoma, prior CPC, visual acuity (VA) of no light perception or unable to be assessed due to patient's mental status, aphakia, or follow-up <3 months. The primary outcome measure was surgical success defined as an intraocular pressure (IOP) of 6-21 mmHg with a ≥20 % reduction from baseline, no glaucoma re-operation, and no loss of light-perception. Secondary outcome measures included VA, glaucoma medication use, and post-surgical complications. Analysis was also stratified by lens status as literature suggests a greater IOP-lowering effect in pseudophakic eyes after CPC. Results: There were 28 eligible patients (6 phakic, 22 pseudophakic) included in this analysis. Mean follow-up was 11.6 ± 8.3 months, and 14 patients had postoperative year 1 data available. The mean age was 75.2 ± 13.9 years, 42.9 % were female, and 92.9 % were African American, reflective of the demographics of the local community. The cumulative success rate was 68.5 % at 1 year and did not differ significantly between phakic and pseudophakic patients. Mean VA worsened from 20/600 preoperatively to 20/1050 at last follow-up (P = 0.04) and was marginally worse in the phakic group (P = 0.15). Mean IOP decreased from 31.1 ± 13.2 mmHg on 4.0 ± 1.5 medications preoperatively to 13.8 ± 7.1 mmHg on 2.6 ± 1.5 medications at last follow-up (P < 0.001; P < 0.01), with a more pronounced effect among pseudophakic patients. 85.7 % of patients had prolonged anterior chamber (AC) inflammation beyond 1 month, which persisted in 10.7 % at last follow-up. The cystoid macular edema (CME) rate was 21.4 %, with 10.7 % persistent at last follow-up. Conclusions: SC-TSCPC is an effective, non-incisional IOP-lowering procedure in phakic and pseudophakic eyes that may not otherwise be ideal candidates for incisional glaucoma surgery. Pseudophakic eyes may experience larger reductions in IOP, however, laser settings can be titrated on a case-by-case basis depending on individual patients' goals. There was a higher incidence of prolonged AC inflammation and CME in our cohort compared to similar studies which report rates of 12.7 % and 2.7 %, respectively. Although the significance of such complications may differ based on the visual potential of each patient, these findings support existing literature that African American patients can have greater incidence of inflammation and subsequent sequalae after ocular surgery.

2.
Am J Ophthalmol Case Rep ; 32: 101948, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38020209

RESUMEN

Purpose: To describe two surgical techniques for removing Baerveldt-350 Glaucoma Implants (BGI-350). Observations and plan: A 91-year-old female with history of bilateral BGI-350s and prior history of tube associated endophthalmitis in the left eye requiring tube removal and resultant phthisis was referred for tube erosion and hypopyon in the right only-seeing eye, and we recommended tube removal. On exam, the left phthisical eye still had a BGI-350 plate attached under the lateral rectus muscle by one anchoring stalk, as it had not been fully removed previously, and the patient recalled severe pain during attempted tube removal in the left eye. We performed concurrent removal of both BGI-350s under general anesthesia. We describe a surgical technique for removing a BGI-350 when the conjunctiva does not need to be spared for future surgery. We also present a second case of BGI-350 removal with a different technique that aims to spare the conjunctiva for future surgery. Conclusions and importance: BGI-350s can develop complications requiring repositioning, revision, or removal. Improper removal of BGI-350s can lead to patient discomfort and future complications. We highlight two different techniques to remove a BGI-350, depending on whether the conjunctiva is intended to be spared for future surgery or not. With either technique, we advocate for general anesthesia and a posterior scleral traction suture to provide patient comfort and optimal exposure of the surgical field.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA