1.
Magn Reson Med ; 91(4): 1419-1433, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38115639

RESUMEN

PURPOSE: To validate single reference variable flip angle (SR-VFA) dynamic T1 mapping with and without T2 * correction against inversion recovery (IR) T1 measurements. METHODS: A custom cylindrical phantom with three concentric compartments was filled with variably doped agar to produce a smooth spatial gradient of the T1 relaxation rate as a function of angle across each compartment. IR T1 , VFA T1 , and B1 + measurements were made on the phantom before rotation, and multi-echo stack-of-radial dynamic images were acquired during rotation via an MRI-compatible motor. B1 + -corrected SR-VFA and SR-VFA-T2 * T1 maps were computed from the sliding window reconstructed images and compared against rotationally registered IR and VFA T1 maps to determine the percentage error. RESULTS: Both VFA and SR-VFA-T2 * T1 maps fell within 10% of IR T1 measurements for a low rotational speed, with a mean accuracy of 2.3% ± 2.6% and 2.8% ± 2.6%, respectively. Increasing rotational speed was found to decrease the accuracy due to increasing temporal smoothing over ranges where the T1 change had a nonconstant slope. SR-VFA T1 mapping was found to have similar accuracy as the SR-VFA-T2 * and VFA methods at low TEs (˜<2 ms), whereas accuracy degraded strongly with later TEs. T2 * correction of the SR-VFA T1 maps was found to consistently improve accuracy and precision, especially at later TEs. CONCLUSION: SR-VFA-T2 * dynamic T1 mapping was found to be accurate against reference IR T1 measurements within 10% in an agar phantom. Further validation is needed in mixed fat-water phantoms and in vivo.


Asunto(s)
Imagen por Resonancia Magnética , Agua , Agar , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen
2.
Magn Reson Med ; 89(6): 2171-2185, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36656135

RESUMEN

PURPOSE: To develop an efficient MRI pulse sequence to simultaneously measure multiple parameters that have been shown to correlate with tissue nonviability following thermal therapies. METHODS: A 3D segmented EPI pulse sequence was used to simultaneously measure proton resonance frequency shift (PRFS) MR thermometry (MRT), T1 relaxation time, and shear wave velocity induced by focused ultrasound (FUS) push pulses. Experiments were performed in tissue mimicking gelatin phantoms and ex vivo bovine liver. Using a carefully designed FUS triggering scheme, a heating duty cycle of approximately 65% was achieved by interleaving FUS ablation pulses with FUS push pulses to induce shear waves in the tissue. RESULTS: In phantom studies, temperature increases measured with PRFS MRT and increases in T1 correlated with decreased shear wave velocity, consistent with material softening with increasing temperature. During ablation in ex vivo liver, temperature increase measured with PRFS MRT initially correlated with increasing T1 and decreasing shear wave velocity, and after tissue coagulation with decreasing T1 and increasing shear wave velocity. This is consistent with a previously described hysteresis in T1 versus PRFS curves and increased tissue stiffness with tissue coagulation. CONCLUSION: An efficient approach for simultaneous and dynamic measurements of PRSF, T1 , and shear wave velocity during treatment is presented. This approach holds promise for providing co-registered dynamic measures of multiple parameters, which correlates to tissue nonviability during and following thermal therapies, such as FUS.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Animales , Bovinos , Protones , Ultrasonografía , Temperatura , Imagen por Resonancia Magnética , Fantasmas de Imagen
3.
Neuroradiology ; 65(2): 287-295, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36278979

RESUMEN

PURPOSE: Covert brain infarctions (CBIs) and cerebral microbleeds (CMBs) represent subclinical sequelae of ischemic and hemorrhagic cerebral small vessel disease, respectively. In addition to thromboembolic stroke, carotid atherosclerosis has been associated with downstream vascular brain injury, including inflammation and small vessel disease. The specific plaque features responsible for this are unknown. We aimed to determine the association of specific vulnerable carotid plaque features to CBIs and CMBs to better understand the relation of large and small vessel disease in a single-center retrospective observational study. METHODS: Intraplaque hemorrhage (IPH) and plaque ulceration were recorded on carotid MRA and total, cortical, and lacunar CBIs and CMBs were recorded on brain MR in 349 patients (698 carotid arteries). Multivariable Poisson regression was performed to relate plaque features to CBIs and CMBs. Within-subject analysis in those with unilateral IPH and ulceration was performed with Poisson regression. RESULTS: Both IPH and plaque ulceration were associated with total CBI (prevalence ratios (PR) 3.33, 95% CI: 2.16-5.15 and 1.91, 95% CI: 1.21-3.00, respectively), after adjusting for stenosis, demographic, and vascular risk factors. In subjects with unilateral IPH, PR was 2.83, 95% CI: 1.76-4.55, for CBI in the ipsilateral hemisphere after adjusting for stenosis. Among those with unilateral ulceration, PR was 1.82, 95% CI: 1.18-2.81, for total CBI ipsilateral to ulceration after adjusting for stenosis. No statistically significant association was seen with CMBs. CONCLUSION: Both IPH and plaque ulceration are associated with total, cortical, and lacunar type CBIs but not CMBs suggesting that advanced atherosclerosis contributes predominantly to ischemic markers of subclinical vascular injury.


Asunto(s)
Estenosis Carotídea , Placa Aterosclerótica , Humanos , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Constricción Patológica/complicaciones , Imagen por Resonancia Magnética , Arterias Carótidas , Placa Aterosclerótica/complicaciones , Placa Aterosclerótica/diagnóstico por imagen , Factores de Riesgo , Infarto Encefálico , Hemorragia Cerebral/diagnóstico por imagen , Hemorragia Cerebral/complicaciones
4.
Neurocrit Care ; 38(2): 235-241, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36002634

RESUMEN

BACKGROUND: In this study, we identify factors associated with ketamine success in the treatment of refractory status epilepticus (SE). We also evaluate for adverse events including systemic and cerebral hemodynamic stability and fluid volume overload. METHODS: In this retrospective, large, single-center, observational study over a 10-year period, 879 consecutive patients receiving intravenous (IV) ketamine were reviewed, and 81 patients were identified as receiving IV ketamine for the treatment of SE. Descriptive analysis was done to determine treatment response and adverse events in patients receiving IV ketamine for SE. Multivariable logistic regression analyses were fitted to determine prediction models for seizure cessation. RESULTS: Permanent cessation of SE was achieved in 49 of 81 (60.5%) of patients for whom ketamine was part of the treatment plan. Of those, 36 (44.4%) were attributed to ketamine as the last drug used (ketamine-associated cessation [AC]). Prior history of epilepsy had an odds ratio of 3.19 (confidence interval 0.83-12.67, p = 0.09) associated with efficacious medication response. Increased latency to ketamine was associated with cessation of SE specifically in patients in the AC group (p = 0.077). Longer SE duration (p = 0.04), administration of ketamine loading dose (bolus; p = 0.03), and anoxia (p = 0.007) were negatively associated with AC. Administration of ketamine loading dose (p = 0.02) and anoxia (p = 0.009) were negatively associated with overall SE cessation. There was no significant impact of ketamine on cerebral hemodynamics, but evidence of fluid volume overload was seen (28.4% of patients). CONCLUSIONS: Our cohort is a large observational study showing a high success rate of permanent cessation of SE after the addition of ketamine. Using multivariable analysis, we demonstrate a significant association with seizure cessation in patients with prior history of epilepsy and those with prolonged latency to ketamine initiation. Furthermore, we describe the impact of fluid volume overload as an anticipated complication with ketamine use.


Asunto(s)
Ketamina , Estado Epiléptico , Humanos , Ketamina/uso terapéutico , Anticonvulsivantes/uso terapéutico , Estudios Retrospectivos , Estado Epiléptico/etiología , Convulsiones/tratamiento farmacológico
5.
Magn Reson Med ; 88(3): 1098-1111, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35576148

RESUMEN

PURPOSE: Present a method to use change in phase in repeated Cartesian k-space measurements to monitor the change in magnetic field for dynamic MR temperature imaging. METHODS: The method is applied to focused ultrasound heating experiments in a gelatin phantom and an ex vivo salt pork sample, without and with simulated respiratory motion. RESULTS: In each experiment, phase variations due to B0 field drift and respiration were readily apparent in the measured phase difference. With correction, the SD of the temperature over time was reduced from 0.18°C to 0.14°C (no breathing) and from 0.81°C to 0.22°C (with breathing) for the gelatin phantom, and from 0.68°C to 0.13°C (no breathing) and from 1.06°C to 0.17°C (with breathing) for the pork sample. The accuracy in nonheated regions, assessed as the RMS error deviation from 0°C, improved from 1.70°C to 1.11°C (no breathing) and from 4.73°C to 1.47°C (with breathing) for the gelatin phantom, and from 5.95°C to 0.88°C (no breathing) and from 13.40°C to 1.73°C (with breathing) for the pork sample. The correction did not affect the temperature measurement accuracy in the heated regions. CONCLUSION: This work demonstrates that phase changes resulting from variations in B0 due to drift and respiration, commonly seen in MR thermometry applications, can be measured directly from 3D Cartesian acquisition methods. The correction of temporal field variations using the presented technique improved temperature accuracy, reduced variability in nonheated regions, and did not reduce accuracy in heated regions.


Asunto(s)
Gelatina , Termometría , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen , Temperatura , Termometría/métodos
6.
Int J Hyperthermia ; 39(1): 1387-1396, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36336401

RESUMEN

PURPOSE: To develop and evaluate susceptibility corrected 2D proton resonance frequency (PRF)-based magnetic resonance (MR)-thermometry for the accurate assessment of the ablation zone of hepatic microwave ablation (MWA). METHODS AND MATERIALS: Twelve hepatic MWA were performed in five LEWE minipigs with human-like fissure-free liver. Temperature maps during ablation of PRF-based MR-thermometry were corrected by modeling heat induced susceptibility changes. Ablation zones were determined using cumulative equivalent minutes at 43 °C (CEM43) as tissue damage model. T1 weighted (w) post-ablation contrast-enhanced (CE) MR-imaging and manually segmented postmortem histology were used for validation. The agreement of uncorrected (raw) and susceptibility corrected (corr) MR-thermometry with T1w post-ablation CE MR-imaging and histology was evaluated. The Wilcoxon-signed rank test and Bland-Altman analysis were applied. RESULTS: With the susceptibility corrected MR-thermometry a significantly increased dice coefficient (raw: 77% vs. corr: 83%, p < 0.01) and sensitivity (raw: 72% vs. corr: 82%, p < 0.01) was found for the comparison to T1w-CE imaging as well as histopathology (dice coefficients: raw: 76% vs. corr: 79%, p < 0.001; sensitivity: raw: 72% vs. corr: 74%, p < 0.001). While major axis length was significantly increased (7.1 mm, p < 0.001) and minor axis length significantly decreased (2.2 mm, p < 0.001) in uncorrected MR-thermometry compared to T1w-CE MR-imaging, no significant bias was found after susceptibility correction. CONCLUSION: Using susceptibility corrected 2D PRF-based MR-thermometry to predict the ablation zones of hepatic MWA provided a good agreement in comparison to T1w post-ablation CE MR-imaging and histopathology.

7.
NMR Biomed ; 34(11): e4582, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34296793

RESUMEN

Ischemic events related to carotid disease are far more strongly associated with plaque instability than stenosis. 3D high-resolution diffusion-weighted (DW) imaging can provide quantitative diffusion measurements on carotid atherosclerosis and may improve detection of vulnerable intraplaque hemorrhage (IPH). The 3D DW-stack of stars (SOS) sequence was implemented with 3D SOS acquisition combined with DW preparation. After simulation of signals created from 3D DW-SOS, phantom studies were performed. Three healthy subjects and 20 patients with carotid disease were recruited. Apparent diffusion coefficient (ADC) values were statistically analyzed on three subgroups by using a two-group comparison Wilcoxon-Mann-Whitney U test with p values less than 0.05: symptomatic versus asymptomatic; IPH-positive versus IPH-negative; and IPH-positive symptomatic versus asymptomatic plaques to determine the relationship with plaque vulnerability. ADC values calculated by 3D DW-SOS provided values similar to those calculated from other techniques. Mean ADC of symptomatic plaque was significantly lower than asymptomatic plaque (0.68 ± 0.18 vs. 0.98 ± 0.16 x 10-3  mm2 /s, p < 0.001). ADC was also significantly lower in IPH-positive versus IPH-negative plaque (0.68 ± 0.13 vs. 1.04 ± 0.11 x 10-3  mm2 /s, p < 0.001). Additionally, ADC was significantly lower in symptomatic versus asymptomatic IPH-positive plaque (0.57 ± 0.09 vs. 0.75 ± 0.11 x 10-3  mm2 /s, p < 0.001). Our results provide strong evidence that ADC measurements from 3D DW-SOS correlate with the symptomatic status of extracranial internal carotid artery plaque. Further, ADC improved discrimination of symptomatic plaque in IPH. These data suggest that diffusion characteristics may improve detection of destabilized plaque leading to elevated stroke risk.


Asunto(s)
Estenosis Carotídea/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Hemorragia/diagnóstico por imagen , Imagenología Tridimensional , Simulación por Computador , Humanos , Fantasmas de Imagen , Procesamiento de Señales Asistido por Computador
8.
Artículo en Inglés | MEDLINE | ID: mdl-34899097

RESUMEN

PURPOSE: Although full-wave simulations could be used to aid in RF coil design, the algorithms may be too slow for an iterative optimization algorithm. If quasistatic simulations are accurate within the design tolerance, then their use could reduce simulation time by orders of magnitude compared to full-wave simulations. This paper examines the accuracy of quasistatic and full-wave simulations at 3 Tesla. METHODS: Three sets of eight coils ranging from 3-10 cm (24 total) were used to measure SNR on three phantoms with conductivities of 0.3, 0.6, and 0.9 S/m. The phantom conductivities were chosen to represent those typically found in human tissues. The range of coil element sizes represents the sizes of coil elements seen in typical coil designs. SNR was determined using the magnetic and electric fields calculated by quasistatic and full-wave simulations. Each simulated SNR dataset was scaled to minimize the root mean squared error (RMSE) when compared against measured SNR data. In addition, the noise values calculated by each simulation were compared against benchtop measured noise values. RESULTS: The RMSE was 0.285 and 0.087 for the quasistatic and full-wave simulations, respectively. The maximum and minimum quotient values, when taking the ratio of simulated to measured SNR values, were 1.69 and 0.20 for the quasistatic simulations and 1.29 and 0.75 for the full-wave simulations, respectively. The ratio ranges, for the calculated quasistatic and full-wave total noise values compared to benchtop measured noise values, were 0.83-1.06 and 0.27-3.02, respectively. CONCLUSIONS: Full-wave simulations were on average 3x more accurate than the quasistatic simulations. Full-wave simulations were more accurate in characterizing the wave effects within the sample, though they were not able to fully account for the skin effect when calculating coil noise.

9.
Int J Hyperthermia ; 37(1): 283-290, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32204632

RESUMEN

Purpose: To develop and characterize a tissue-mimicking phantom that enables the direct comparison of magnetic resonance (MR) and ultrasound (US) imaging techniques useful for monitoring high-intensity focused ultrasound (HIFU) treatments. With no additions, gelatin phantoms produce little if any scattering required for US imaging. This study characterizes the MR and US image characteristics as a function of psyllium husk concentration, which was added to increase US scattering.Methods: Gelatin phantoms were constructed with varying concentrations of psyllium husk. The effects of psyllium husk concentration on US B-mode and MR imaging were evaluated at nine different concentrations. T1, T2, and T2* MR maps were acquired. Acoustic properties (attenuation and speed of sound) were measured at frequencies of 0.6, 1.0, 1.8, and 3.0 MHz using a through-transmission technique. Phantom elastic properties were evaluated for both time and temperature dependence.Results: Ultrasound image echogenicity increased with increasing psyllium husk concentration while quality of gradient-recalled echo MR images decreased with increasing concentration. For all phantoms, the measured speed of sound ranged between 1567-1569 m/s and the attenuation ranged between 0.42-0.44 dB/(cm·MHz). Measured T1 ranged from 974-1051 ms. The T2 and T2* values ranged from 97-108 ms and 48-88 ms, respectively, with both showing a decreasing trend with increased psyllium husk concentration. Phantom stiffness, measured using US shear-wave speed measurements, increased with age and decreased with increasing temperature.Conclusions: The presented dual-use tissue-mimicking phantom is easy to manufacture and can be used to compare and evaluate US-guided and MR-guided HIFU imaging protocols.


Asunto(s)
Gelatina/química , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética/métodos , Fantasmas de Imagen/normas , Psyllium/química , Ultrasonografía/métodos , Humanos
10.
Artículo en Inglés | MEDLINE | ID: mdl-34867110

RESUMEN

Phased array (PA) receive coils are built such that coil elements approximate independent antenna behavior. One method of achieving this goal is to use an available decoupling method to decouple adjacent coil elements. The purpose of this work was to compare the relative performance of two decoupling methods as a function of variation in sample load. Two PA receive coils with 5 channels (5-ch) each, equal outer dimensions, and formed on 12 cm diameter cylindrical phantoms of conductivities 0.3, 0.6, and 0.9 S/m were evaluated for relative signal-to-noise ratio (SNR) and parallel imaging performance. They were only tuned and matched to the 0.6 S/m phantom. Simulated and measured axial, sagittal, and coronal 5-ch PA coil SNR ratios were compared by dividing the overlap by the capacitive decoupled coil SNR results. Issues related to the selection of capacitor values for the two decoupling methods were evaluated by taking the ratio of the match and tune capacitors for large and small 2 channel (2-ch) PA coils. The SNR ratios showed that the SNR of the two decoupling methods were very similar. The inverse geometry-factor maps showed similar but better overall parallel imaging performance for the capacitive decoupled method. The quotients for the 2-ch PA coils' maximum and minimum capacitor value ratios are 3.28 and 1.38 for the large and 3.28 and 2.22 for the small PA. The results of this paper demonstrate that as the sample load varies, the capacitive and overlap decoupling methods are very similar in relative SNR and this similarity continues for parallel imaging performance. Although, for the 5-ch coils studied, the capacitive decoupling method has a slight SNR and parallel imaging advantage and it was noted that the capacitive decoupled coil is more likely to encounter unbuildable PA coil configurations.

11.
Magn Reson Med ; 81(1): 247-257, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30058224

RESUMEN

PURPOSE: To construct a predictive model that describes how the duration and symmetry of a k-space-weighted image contrast (KWIC) window affects the temporal resolution of differently sized ultrasound foci when using a pseudo-golden angle stack-of-stars acquisition. METHODS: We performed a modulation analysis of proton resonance frequency temperature measurements to create the temporal modulation transfer function for KWIC windows of different symmetry and temporal duration. We reconstructed simulated ultrasound heating trajectories and stack-of-stars k-space data as well as experimental phantom data using the same trajectories. Images were reconstructed using symmetric and asymmetric KWIC windows of 3 different temporal durations. Simulated results were compared against temporal modulation transfer function predictions, experimental results, and the original simulated temperatures. RESULTS: The temporal modulation transfer function shows that temporal resolution with KWIC reconstructions depend on the object size. The KWIC window duration affected SNR and severity of undersampling artifacts. Accuracy and response delay improved as the KWIC window duration decreased or the size of the heated region within the KWIC plane increased. Precision worsened as the window duration decreased. Using a symmetric window eliminated the response delay to heated region size but introduced a large reconstruction delay. CONCLUSION: The accuracy and precision of proton resonance frequency temperature measurements from a stack-of-stars acquisition using a sliding KWIC window reconstruction are dependent on the size of the KWIC window and the size and shape of the heated region. The temporal modulation transfer function of KWIC reconstructions for any object size can predict the temporal response to changes in signal being acquired, such as temperature and contrast enhancement.


Asunto(s)
Mama/diagnóstico por imagen , Diagnóstico por Imagen , Procesamiento de Imagen Asistido por Computador/métodos , Termometría/métodos , Ultrasonografía , Acústica , Algoritmos , Artefactos , Simulación por Computador , Femenino , Análisis de Fourier , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Distribución Normal , Fantasmas de Imagen , Protones , Reproducibilidad de los Resultados , Relación Señal-Ruido , Temperatura
12.
Magn Reson Med ; 81(2): 1104-1117, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30257059

RESUMEN

PURPOSE: To implement and evaluate an efficient multiple-point MR acoustic radiation force imaging pulse sequence that can volumetrically measure tissue displacement and evaluate tissue stiffness using focused ultrasound (FUS) radiation force. METHODS: Bipolar motion-encoding gradients were added to a gradient-recalled echo segmented EPI pulse sequence with both 2D and 3D acquisition modes. Multiple FUS-ON images (FUS power > 0 W) were interleaved with a single FUS-OFF image (FUS power = 0 W) on the TR level, enabling simultaneous measurements of volumetric tissue displacement (by complex subtraction of the FUS-OFF image from the FUS-ON images) and proton resonance frequency shift MR thermometry (from the OFF image). Efficiency improvements included partial Fourier acquisition, parallel imaging, and encoding up to 4 different displacement positions into a single image. Experiments were performed in homogenous and dual-stiffness phantoms, and in ex vivo porcine brain. RESULTS: In phantoms, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 5 s to 10 s for a 2D slice, and 60 s for a 3D volume, using parallel imaging and encoding 2 displacement positions/image. In ex vivo porcine brain, 16-point multiple-point magnetic resonance acoustic radiation force imaging maps could be acquired in 20 s for a 3D volume, using partial Fourier and parallel imaging and encoding 4 displacement positions/image. In 1 experiment it was observed that tissue displacement in ex vivo brain decreased by approximately 22% following FUS ablation. CONCLUSION: With the described efficiency improvements it is possible to acquire volumetric multiple-point magnetic resonance acoustic radiation force imaging maps, with simultaneous proton resonance frequency shift MR thermometry maps, in clinically acceptable times.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagenología Tridimensional/métodos , Termometría , Algoritmos , Animales , Diagnóstico por Imagen de Elasticidad , Análisis de Fourier , Imagen por Resonancia Magnética , Movimiento (Física) , Fantasmas de Imagen , Porcinos , Ultrasonografía
13.
Magn Reson Med ; 81(5): 3138-3152, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30652347

RESUMEN

PURPOSE: Implement simultaneous proton resonance frequency (PRF) shift and T1 measurements with equivalent temporal resolution using a single reference variable flip angle method. This novel method allows for simultaneous thermometry in both aqueous and fatty tissue. METHODS: This method acquires a single reference image at the lower flip angle and all dynamic images at the higher angle. T1 is calculated using a single reference variable flip angle method, which accounts for the reference image temperature remaining constant. Monte Carlo simulations determined the optimal dynamic flip angle for combined PRF and T1 measurements. This method was evaluated in MR-guided focused ultrasound heating experiments using a gelatin phantom and human cadaver breasts. In vivo measurement precision was demonstrated in healthy female volunteers under nonheating conditions. RESULTS: Temperature rise during MR-guided focused ultrasound heating was measured in aqueous tissue with both PRF and T1 . Both measures show good qualitative agreement in both space and time in aqueous tissue. The T1 change due to temperature increase was measured in fat, demonstrating the expected temporal response. The dynamic flip angle that produces optimal SNR for PRF measurements is lower than the optimal angle for T1 measurements, necessitating the selection of a compromise angle. CONCLUSION: The single reference variable flip angle method provides a reliable way to simultaneously measure PRF temperature and T1 change and overcomes PRF's inability to simultaneously monitor temperature in aqueous and adipose tissues. Future work will calibrate T1 change to temperature, enabling real-time temperature in fat and increasing patient safety and treatment efficacy during thermal interventional treatments.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Mama/diagnóstico por imagen , Imagen por Resonancia Magnética , Termometría/métodos , Algoritmos , Cadáver , Calibración , Simulación por Computador , Femenino , Gelatina , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Método de Montecarlo , Fantasmas de Imagen , Protones , Valores de Referencia , Reproducibilidad de los Resultados , Temperatura
14.
Magn Reson Med ; 81(5): 3153-3167, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30663806

RESUMEN

PURPOSE: To present a novel MR shear wave elastography (MR-SWE) method that efficiently measures the speed of propagating wave packets generated using acoustic radiation force (ARF) impulses. METHODS: ARF impulses from a focused ultrasound (FUS) transducer were applied sequentially to a preselected set of positions and motion encoded MRI was used to acquire volumetric images of the propagating shear wavefront emanating from each point. The wavefront position at multiple propagation times was encoded in the MR phase image using a train of motion encoding gradient lobes. Generating a transient propagating wavefront at multiple spatial positions and sampling each at multiple time-points allowed for shear wave speed maps to be efficiently created. MR-SWE was evaluated in tissue mimicking phantoms and ex vivo bovine liver tissue before and after ablation. RESULTS: MR-SWE maps, covering an in-plane area of ~5 × 5 cm, were acquired in 12 s for a single slice and 144 s for a volumetric scan. MR-SWE detected inclusions of differing stiffness in a phantom experiment. In bovine liver, mean shear wave speed significantly increased from 1.65 ± 0.18 m/s in normal to 2.52 ± 0.18 m/s in ablated region (n = 581 pixels; P-value < 0.001). CONCLUSION: MR-SWE is an elastography technique that enables precise targeting and excitation of the desired tissue of interest. MR-SWE may be particularly well suited for treatment planning and endpoint assessment of MR-guided FUS procedures because the same device used for therapy can be used as an excitation source for tissue stiffness quantification.


Asunto(s)
Acústica , Diagnóstico por Imagen de Elasticidad , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Animales , Bovinos , Modelos Animales , Movimiento (Física) , Fantasmas de Imagen , Resistencia al Corte , Estrés Mecánico , Transductores
15.
Neuroradiology ; 61(6): 643-650, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30675639

RESUMEN

PURPOSE: Quantitative measures of vessel wall magnetic resonance imaging (vwMRI) for the evaluation of intracranial atherosclerotic disease (ICAD) offers standardization not available with previously used qualitative approaches that may be difficult to replicate. METHODS: vwMRI studies performed to evaluate ICAD that had caused a stroke were analyzed. Two blinded reviewers qualitatively rated culprit lesions for the presence of enhancement on T1 delay alternating with nutation for tailored excitation (DANTE) SPACE images. At least 3 months later, quantitative analysis was performed of the same images, comparing lesion enhancement to reference structures. Cohen's kappa and intraclass correlation coefficients were calculated to assess agreement. Ratios of enhancement of lesions to references were compared to qualitative ratings. RESULTS: Studies from 54 patients met inclusion criteria. A mean of 49 (90.7%) lesions were qualitatively rated as enhancing, with good inter-rater agreement (κ = 0.783). Among reference structure candidates, low infundibulum demonstrated the highest inter-rater agreement on pre- and post-contrast imaging. The ratio of percentage increase in plaque signal following contrast to the same measure in low infundibulum demonstrated the highest agreement with qualitative assessment, with highest agreement seen with a ratio of 0.8 set as a threshold (κ = 0.675). CONCLUSION: Quantitative metrics can yield objective data to better standardize techniques and acceptance of vwMRI evaluation of ICAD. The low infundibulum had the highest inter-rater agreement on both pre- and post-contrast images and is best suited as a normally enhancing reference structure. Such quantitative techniques should be implemented in future research of vwMRI for the evaluation of ICAD.


Asunto(s)
Aumento de la Imagen/métodos , Arteriosclerosis Intracraneal/diagnóstico por imagen , Angiografía por Resonancia Magnética/métodos , Anciano , Medios de Contraste , Femenino , Humanos , Arteriosclerosis Intracraneal/complicaciones , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Accidente Cerebrovascular/etiología
16.
Lasers Surg Med ; 51(3): 286-300, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30645017

RESUMEN

OBJECTIVES: To develop, test and evaluate improved 2D and 3D protocols for proton resonance frequency shift magnetic resonance temperature imaging (MRTI) of laser interstitial thermal therapy (LITT). The objective was to develop improved MRTI protocols in terms of temperature measurement precision and volume coverage compared to the 2D MRTI protocol currently used with a commercially available LITT system. METHODS: Four different 2D protocols and four different 3D protocols were investigated. The 2D protocols used multi-echo readouts to prolong the total MR sampling time and hence the MRTI precision, without prolonging the total acquisition time. The 3D protocols provided volumetric thermometry by acquiring a slab of 12 contiguous slices in the same acquisition time as the 2D protocols. The study only considered readily available pulse sequences (Cartesian 2D and 3D gradient recalled echo and echo planar imaging [EPI]) and methods (partial Fourier and parallel imaging) to ensure wide availability and rapid clinical implementation across vendors and field strengths. In vivo volunteer studies were performed to investigate and compare MRTI precision and image quality. Phantom experiments with LITT heating were performed to investigate and compare MRTI precision and accuracy. Different coil setups were used in the in vivo studies to assess precision differences between using local (such as flex and head coils) and non-local (i.e., body coil) receive coils. Studies were performed at both 1.5 T and 3 T. RESULTS: The improved 2D protocols provide up to a factor of two improvement in the MRTI precision in the same acquisition time, compared to the currently used clinical protocol. The 3D echo planar imaging protocols provide comparable precision as the currently used 2D clinical protocol, but over a substantially larger field of view, without increasing the acquisition time. As expected, local receive coils perform substantially better than the body coil, and 3 T provides better MRTI accuracy and precision than 1.5 T. 3D data can be zero-filled interpolated in all three dimensions (as opposed to just two dimensions for 2D data), reducing partial volume effects and measuring higher maximum temperature rises. CONCLUSIONS: With the presented protocols substantially improved MRTI precision (for 2D imaging) or greatly improved field of view coverage (for 3D imaging) can be achieved in the same acquisition time as the currently used protocol. Only widely available pulse sequences and acquisition methods were investigated, which should ensure quick translation to the clinic. Lasers Surg. Med. 51:286-300, 2019. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Encéfalo/diagnóstico por imagen , Hipertermia Inducida , Imagenología Tridimensional , Imagen por Resonancia Magnética , Termometría/métodos , Protocolos Clínicos , Imagen Eco-Planar , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados
17.
J Stroke Cerebrovasc Dis ; 28(5): 1168-1172, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30683492

RESUMEN

BACKGROUND: Hypertensive emergency is commonly associated with acute ischemic stroke and can be a predictor of poor outcome in these patients. Nicardipine and labetalol are commonly administered for the treatment of acute hypertension following stroke. Yet, data are lacking on the safety of these agents in this setting. OBJECTIVE: This study aimed to determine all-cause in-hospital mortality, medication-related hypotensive episodes, development of hospital acquired infections and hospital length of stay between nicardipine and labetalol use for the management of hypertension after acute ischemic stroke. METHODS: This retrospective study used a prospective database of individuals admitted to the neurointensive care unit at a university-based hospital over 39 months. Patients with confirmed ischemic strokes were included in this analysis. Data were recorded for administration of nicardipine and labetalol following acute stroke. RESULTS: A total of 244 patients with acute ischemic stroke were included in this analysis (mean age, 64.3 ± 15 years; 52.2% males). Nicardipine use after acute ischemic stroke was associated with an increased risk of 30-day mortality (odds ratio [OR]: 4.6, 95% confidence interval [CI] 1.3-15.7; P = .02). A single episode of hypotension in the first 72hours of admission was also significantly associated with mortality (OR 4.35 [95% CI 1.2-14.9]; P = .02). CONCLUSIONS: Nicardipine was associated with an increased risk of short-term mortality after acute ischemic stroke. This may have been due to hypotension, tachycardia, or pulmonary edema which were not apparent in our study. Further studies are required to elucidate the cause of this association.


Asunto(s)
Antihipertensivos/efectos adversos , Isquemia Encefálica/tratamiento farmacológico , Isquemia Encefálica/mortalidad , Mortalidad Hospitalaria , Hipertensión/tratamiento farmacológico , Hipertensión/mortalidad , Nicardipino/efectos adversos , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/mortalidad , Anciano , Presión Sanguínea/efectos de los fármacos , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatología , Enfermedad Crítica , Bases de Datos Factuales , Femenino , Humanos , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Hipotensión/inducido químicamente , Hipotensión/mortalidad , Hipotensión/fisiopatología , Labetalol/efectos adversos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
18.
Stroke ; 49(10): 2337-2344, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30355108

RESUMEN

Background and Purpose- Cervical artery dissection is a major cause of ischemic stroke in the young and presents with various imaging findings, including stenosis and intramural hematoma (IMH). Our goal was to determine the relative contribution of lumen findings and IMH to acute ischemic stroke and whether a heavily T1-weighted sequence could more reliably detect IMH. Methods- Institutional review board approval was obtained for this retrospective study of 254 patients undergoing magnetic resonance imaging/magnetic resonance angiography for suspected dissection. Imaging included standard turbo spin-echo (TSE) T1-fat saturation and heavily T1-weighted flow-suppressed magnetization-prepared rapid acquisition gradient-recalled echo sequences. Subjects with stents (1) or atherosclerotic disease (26) were excluded, leaving 227 subjects. Kappa analysis was used to determine IMH interrater reliability on magnetization-prepared rapid acquisition gradient-recalled echo and T1-fat saturation in 4 vessels per subject. Lumen findings, cardiovascular risk factors, medications, and nondissection stroke sources were recorded. Mixed-effects multivariate Poisson regression was used to determine the prevalence ratio of each factor with acute ischemic stroke, accounting for 4 vessels per patient with backward elimination to a threshold P value of 0.10. Results- Patients were 41.9% men, mean age of 47.3±16.6 years, with 114 dissections and 107 strokes. IMH interrater reliability was significantly higher for magnetization-prepared rapid acquisition gradient-recalled echo (κ=0.83; 95% CI, 0.78-0.86) versus T1-fat saturation (0.58; 95% CI, 0.57-0.68). The final acute stroke prediction model included magnetization-prepared rapid acquisition gradient-recalled echo-detected IMH (prevalence ratio, 2.0; 95% CI, 1.1-3.9; P=0.034), stenosis, pseudoaneurysm, male sex, current smoking, and nondissection stroke sources. The final model had high discrimination for acute stroke (area under the curve, 0.902; 95% CI, 0.872-0.932), compared with models without stenosis (0.861; 95% CI, 0.821-0.902), and without stenosis and IMH (0.831; 95% CI, 0.783-0.879). All 3 models were significantly different at P<0.05. Conclusions- Along with stenosis, IMH detection significantly contributed to acute ischemic stroke pathogenesis in patients with suspected cervical artery dissection. In addition, IMH detection can be made more reliable with heavily T1-weighted sequences.


Asunto(s)
Arterias/cirugía , Isquemia Encefálica/diagnóstico por imagen , Hematoma/patología , Accidente Cerebrovascular/diagnóstico por imagen , Adulto , Anciano , Arterias/patología , Imagen de Difusión por Resonancia Magnética/métodos , Femenino , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
19.
Magn Reson Med ; 79(3): 1407-1419, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28643383

RESUMEN

PURPOSE: Implement and evaluate a 3D MRI method to measure temperature changes with high spatial and temporal resolution and large field of view. METHODS: A multiecho pseudo-golden angle stack-of-stars (SOS) sequence with k-space weighted image contrast (KWIC) reconstruction was implemented to simultaneously measure multiple quantities, including temperature, initial signal magnitude M(0), transverse relaxation time ( T2*), and water/fat images. Respiration artifacts were corrected using self-navigation. KWIC artifacts were removed using a multi-baseline library. The phases of the multiple echo images were combined to improve proton resonance frequency precision. Temperature precision was tested through in vivo breast imaging (N = 5 healthy volunteers) using both coronal and sagittal orientations and with focused ultrasound (FUS) heating in a pork phantom using a breast specific MR-guided FUS system. RESULTS: Temperature measurement precision was significantly improved after echo combination when compared with the no echo combination case (spatial average of the standard deviation through time of 0.3-1.0 and 0.7-1.9°C, respectively). Temperature measurement accuracy during heating was comparable to a 3D seg-EPI sequence. M(0) and T2* values showed temperature dependence during heating in pork adipose tissue. CONCLUSION: A self-navigated 3D multiecho SOS sequence with dynamic KWIC reconstruction is a promising thermometry method that provides multiple temperature sensitive quantitative values. Magn Reson Med 79:1407-1419, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Termometría/métodos , Adulto , Algoritmos , Animales , Mama/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Fantasmas de Imagen , Porcinos , Adulto Joven
20.
Magn Reson Med ; 79(3): 1515-1524, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28795419

RESUMEN

PURPOSE: A novel and practical method for simultaneously performing MR acoustic radiation force imaging (ARFI) and proton resonance frequency (PRF)-shift thermometry has been developed and tested. This could be an important tool for evaluating the success of MR-guided focused ultrasound procedures for which MR-thermometry measures temperature and thermal dose and MR-ARFI detects changes in tissue mechanical properties. METHODS: MR imaging was performed using a gradient recalled echo segmented echo-planar imaging pulse sequence with bipolar motion encoding gradients (MEG). Images with ultrasound pulses (ON) and without ultrasound pulses (OFF) during the MEG were interleaved at the repetition time (TR) level. ARFI displacements were calculated by complex subtraction of ON-OFF images, and PRF temperature maps were calculated by baseline subtraction. Evaluations in tissue-mimicking phantoms and ex vivo porcine brain tissue were performed. Constrained reconstruction improved the temporal resolution of dynamic measurements. RESULTS: Simultaneous maps of displacement and temperature were acquired in 2D and 3D while keeping tissue heating < 1°C. Accuracy of the temperature maps was comparable to the standard PRF sequence. Using constrained reconstruction and subsampled k-space (R = 4.33), 3D simultaneous temperature and displacement maps can be acquired every 4.7 s. CONCLUSION: This new sequence acquires simultaneous temperature and displacement maps with minimal tissue heating, and can be applied dynamically for monitoring tissue mechanical properties during ablation procedures. Magn Reson Med 79:1515-1524, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Termometría/métodos , Animales , Encéfalo/diagnóstico por imagen , Fantasmas de Imagen , Porcinos