Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Acta Biomater ; 2024 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-39233254

RESUMEN

Heart valve tissue engineering holds the potential to transform the surgical management of congenital heart defects affecting the pediatric pulmonary valve (PV) by offering a viable valve replacement. While aiming to recapitulate the native valve, the minimum requirement for tissue engineered heart valves (TEHVs) has historically been adequate mechanical function at implantation. However, long-term in situ functionality of TEHVs remains elusive, suggesting that a closer approximation of the native valve is required. The realization of biomimetic engineered pediatric PV is impeded by insufficient characterization of healthy pediatric tissue. In this study, we comprehensively characterized the planar biaxial tensile behaviour, extracellular matrix (ECM) composition and organization, and valvular interstitial cell (VIC) phenotypes of PVs from piglets to provide benchmarks for TEHVs. The piglet PV possessed an anisotropic and non-linear tension-strain profile from which material constants for a predictive constitutive model were derived. The ECM of the piglet PV possessed a trilayer organization populated by collagen, glycosaminoglycans, and elastin. Biochemical quantification of ECM content normalized to wet weight and DNA content of PV tissue revealed homogeneous distribution across sampled regions of the leaflet. Finally, VICs in the piglet PV were primarily quiescent vimentin-expressing fibroblasts, with a small proportion of activated α-smooth muscle actin-expressing myofibroblasts. Overall, piglet PV properties were consistent with those reported anecdotally for pediatric human PVs and distinct from those of adult porcine and human PVs, supporting the utility of the properties determined here to inform the design of tissue engineered pediatric PVs. STATEMENT OF SIGNIFICANCE: Heart valve tissue engineering has the potential to transform treatment for children born with defective pulmonary valves by providing living replacement tissue that can grow with the child. The design of tissue engineered heart valves is best informed by native valve properties, but native pediatric pulmonary valves have not been fully described to date. Here, we provide comprehensive characterization of the planar biaxial tensile behaviour, extracellular matrix composition and organization, and valvular interstitial cell phenotypes of pulmonary valves from piglets as a model for the native human pediatric valve. Together, these findings provide standards that inform engineered heart valve design towards generation of biomimetic pediatric pulmonary valves.

2.
Artículo en Inglés | MEDLINE | ID: mdl-39368732

RESUMEN

OBJECTIVE: There is a high burden of reintervention after repair of Tetralogy of Fallot (TOF). We compare procedural burden and late outcomes in valve sparing repair (VSR) and transannular patch (TAP) cohorts over 30 years. METHODS: Patients undergoing TOF repair (1990-2021, excluding complex TOF) were included in this study (n=1239) with subsequent comparisons between TAP (n=550) and VSR (n=648) cohorts. Descriptive statistics, cumulative incidence frequencies, survival analysis and propensity matching (n=425) were used to analyze reintervention burden and survival. RESULTS: Overall survival of the cohort was 96.7% at 15 years and 95.6% at 25 years, with similar survival between TAP and VSR cohorts (p=0.22). TAP cohort had increased incidence of procedural burden at 25 years (TAP 69.8% versus VSR 37.2%, p<0.001), with 34.6% undergoing ≥2 reinterventions. TAP cohort had higher incidence of surgical PV replacement at 15 years (TAP 20.7% versus VSR 7.6%, p<0.001) and placement of PA stents (TAP 20.2% versus VSR 4.9%, p<0.001). By contrast, VSR had higher incidence of RVOT reoperation at 15 years (VSR 7.3% versus TAP 3.6%, p=0.047). After propensity matching there was no survival advantage between the VSR and TAP cohorts (Era 2) whereas the need for RVOT reoperation was not different between the two cohorts (p=0.060). CONCLUSIONS: The procedural burden remains high following TOF repair. TAP is associated with higher procedural burden in matched and non-matched cohorts. VSR has increased risk of reoperation for RVOT obstruction only in non-matched comparisons. Anatomical complexity and surgical repair strategy influence procedural burden following TOF repair.

3.
Stem Cell Res Ther ; 14(1): 96, 2023 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-37076906

RESUMEN

BACKGROUND: Constructs currently used to repair or replace congenitally diseased pediatric heart valves lack a viable cell population capable of functional adaptation in situ, necessitating repeated surgical intervention. Heart valve tissue engineering (HVTE) can address these limitations by producing functional living tissue in vitro that holds the potential for somatic growth and remodelling upon implantation. However, clinical translation of HVTE strategies requires an appropriate source of autologous cells that can be non-invasively harvested from mesenchymal stem cell (MSC)-rich tissues and cultured under serum- and xeno-free conditions. To this end, we evaluated human umbilical cord perivascular cells (hUCPVCs) as a promising cell source for in vitro production of engineered heart valve tissue. METHODS: The proliferative, clonogenic, multilineage differentiation, and extracellular matrix (ECM) synthesis capacities of hUCPVCs were evaluated in a commercial serum- and xeno-free culture medium (StemMACS™) on tissue culture polystyrene and benchmarked to adult bone marrow-derived MSCs (BMMSCs). Additionally, the ECM synthesis potential of hUCPVCs was evaluated when cultured on polycarbonate polyurethane anisotropic electrospun scaffolds, a representative biomaterial for in vitro HVTE. RESULTS: hUCPVCs had greater proliferative and clonogenic potential than BMMSCs in StemMACS™ (p < 0.05), without differentiation to osteogenic and adipogenic phenotypes associated with valve pathology. Furthermore, hUCPVCs cultured with StemMACS™ on tissue culture plastic for 14 days synthesized significantly more total collagen, elastin, and sulphated glycosaminoglycans (p < 0.05), the ECM constituents of the native valve, than BMMSCs. Finally, hUCPVCs retained their ECM synthesizing capacity after 14 and 21 days in culture on anisotropic electrospun scaffolds. CONCLUSION: Overall, our findings establish an in vitro culture platform that uses hUCPVCs as a readily-available and non-invasively sourced autologous cell population and a commercial serum- and xeno-free culture medium to increase the translational potential of future pediatric HVTE strategies. This study evaluated the proliferative, differentiation and extracellular matrix (ECM) synthesis capacities of human umbilical cord perivascular cells (hUCPVCs) when cultured in serum- and xeno-free media (SFM) against conventionally used bone marrow-derived MSCs (BMMSCs) and serum-containing media (SCM). Our findings support the use of hUCPVCs and SFM for in vitro heart valve tissue engineering (HVTE) of autologous pediatric valve tissue. Figure created with BioRender.com.


Asunto(s)
Células Madre Mesenquimatosas , Ingeniería de Tejidos , Adulto , Humanos , Niño , Cordón Umbilical , Diferenciación Celular , Medios de Cultivo , Células Cultivadas , Proliferación Celular
4.
Ann Biomed Eng ; 50(9): 1073-1089, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35622208

RESUMEN

Repair and replacement solutions for congenitally diseased heart valves capable of post-surgery growth and adaptation have remained elusive. Tissue engineered heart valves (TEHVs) offer a potential biological solution that addresses the drawbacks of existing valve replacements. Typically, TEHVs are made from thin, fibrous biomaterials that either become cell populated in vitro or in situ. Often, TEHV designs poorly mimic the anisotropic mechanical properties of healthy native valves leading to inadequate biomechanical function. Mechanical conditioning of engineered tissues with anisotropic strain application can induce extracellular matrix remodelling to alter the anisotropic mechanical properties of a construct, but implementation has been limited to small-scale set-ups. To address this limitation for TEHV applications, we designed and built a mechanobioreactor capable of modulating biaxial strain anisotropy applied to large, thin, biomaterial sheets in vitro. The bioreactor can independently control two orthogonal stretch axes to modulate applied strain anisotropy on biomaterial sheets from 13 × 13 mm2 to 70 × 40 mm2. A design of experiments was performed using experimentally validated finite element (FE) models and demonstrated that biaxial strain was applied uniformly over a larger percentage of the cell seeded area for larger sheets (13 × 13 mm2: 58% of sheet area vs. 52 × 31 mm2: 86% of sheet area). Furthermore, bioreactor prototypes demonstrated that over 70% of the cell seeding area remained uniformly strained under different prescribed protocols: equibiaxial amplitudes between 5 to 40%, cyclic frequencies between 0.1 to 2.5 Hz and anisotropic strain ratios between 0:1 (constrained uniaxial) to 2:1. Lastly, proof-of-concept experiments were conducted where we applied equibiaxial (εx = εy = 8.75%) and anisotropic (εx = 12.5%, εy = 5%) strain protocols to cell-seeded, electrospun scaffolds. Cell nuclei and F-actin aligned to the vector-sum strain direction of each prescribed protocol (nuclei alignment: equibiaxial: 43.2° ± 1.8°, anisotropic: 17.5° ± 1.7°; p < 0.001). The abilities of this bioreactor to prescribe different strain amplitude, frequency and strain anisotropy protocols to cell-seeded scaffolds will enable future studies into the effects of anisotropic loading protocols on mechanically conditioned TEHVs and other engineered planar connective tissues.


Asunto(s)
Materiales Biocompatibles , Ingeniería de Tejidos , Anisotropía , Matriz Extracelular , Válvulas Cardíacas , Estrés Mecánico , Ingeniería de Tejidos/métodos
5.
Can J Cardiol ; 37(7): 1064-1077, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33839245

RESUMEN

Surgical replacement remains the primary option to treat the rapidly growing number of patients with severe valvular heart disease. Although current valve replacements-mechanical, bioprosthetic, and cryopreserved homograft valves-enhance survival and quality of life for many patients, the ideal prosthetic heart valve that is abundantly available, immunocompatible, and capable of growth, self-repair, and life-long performance has yet to be developed. These features are essential for pediatric patients with congenital defects, children and young adult patients with rheumatic fever, and active adult patients with valve disease. Heart valve tissue engineering promises to address these needs by providing living valve replacements that function similarly to their native counterparts. This is best evidenced by the long-term clinical success of decellularised pulmonary and aortic homografts, but the supply of homografts cannot meet the demand for replacement valves. A more abundant and consistent source of replacement valves may come from cellularised valves grown in vitro or acellular off-the-shelf biomaterial/tissue constructs that recellularise in situ, but neither tissue engineering approach has yet achieved long-term success in preclinical testing. Beyond the technical challenges, heart valve tissue engineering faces logistical, economic, and regulatory challenges. In this review, we summarise recent progress in heart valve tissue engineering, highlight important outcomes from preclinical and clinical testing, and discuss challenges and future directions toward clinical translation.


Asunto(s)
Materiales Biocompatibles/análisis , Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas , Ingeniería de Tejidos , Enfermedades de las Válvulas Cardíacas/complicaciones , Prótesis Valvulares Cardíacas/normas , Prótesis Valvulares Cardíacas/tendencias , Humanos , Efectos Adversos a Largo Plazo/etiología , Efectos Adversos a Largo Plazo/prevención & control , Ensayo de Materiales/métodos , Ingeniería de Tejidos/métodos , Ingeniería de Tejidos/normas , Ingeniería de Tejidos/tendencias , Investigación Biomédica Traslacional
6.
Adv Drug Deliv Rev ; 96: 161-75, 2016 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-26555371

RESUMEN

Surgical replacement of dysfunctional valves is the primary option for the treatment of valvular disease and congenital defects. Existing mechanical and bioprosthetic replacement valves are far from ideal, requiring concomitant anticoagulation therapy or having limited durability, thus necessitating further surgical intervention. Heart valve tissue engineering (HVTE) is a promising alternative to existing replacement options, with the potential to synthesize mechanically robust tissue capable of growth, repair, and remodeling. The clinical realization of a bioengineered valve relies on the appropriate combination of cells, biomaterials, and/or bioreactor conditioning. Biomechanical conditioning of valves in vitro promotes differentiation of progenitor cells to tissue-synthesizing myofibroblasts and prepares the construct to withstand the complex hemodynamic environment of the native valve. While this is a crucial step in most HVTE strategies, it also may contribute to fibrosis, the primary limitation of engineered valves, through sustained myofibrogenesis. In this review, we examine the progress of HVTE and the role of mechanical conditioning in the synthesis of mechanically robust tissue, and suggest approaches to achieve myofibroblast quiescence and prevent fibrosis.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvulas Cardíacas/fisiología , Ingeniería de Tejidos/métodos , Animales , Fenómenos Biomecánicos , Reactores Biológicos , Diferenciación Celular , Matriz Extracelular/química , Válvulas Cardíacas/anatomía & histología , Válvulas Cardíacas/citología , Humanos , Hidrogeles/química , Miofibroblastos/citología , Nanofibras/química , Porosidad , Andamios del Tejido/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA