Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Rapid Commun Mass Spectrom ; 31(21): 1813-1824, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28836303

RESUMEN

RATIONALE: The presence of impurities and degradation products will affect the pharmacokinetic, pharmacodynamic properties and alter the safety of a drug. Hence, the development of a stability-indicating assay method is an integral part of quality product development and is crucial for the regulatory approval of drug products. METHODS: Acotiamide was subjected to stress degradation under hydrolytic, oxidative, photo and thermal stress conditions. The resulted degradation products (DPs), as well as a process-related impurity (IMP), were selectively separated from the drug on a Waters Acquity HSS cyano column (100 × 2.1 mm, 1.8 µm) with a mobile phase containing a gradient mixture of 0.1% formic acid and acetonitrile (ACN) at a flow rate of 0.25 mL min-1 . RESULTS: The drug was found to degrade under hydrolytic (acidic and basic), oxidative and photolytic stress while it remained stable under neutral hydrolytic and thermal stress conditions. The seven degradation products (DPs) and one process-related impurity (IMP) were observed. All the DPs and process-related IMP were well separated by the developed ultra-high-performance liquid chromatography (UHPLC) method and subsequently characterized by UHPLC/electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). The proposed UHPLC method was validated with respect to specificity, linearity, accuracy, precision and robustness as per ICH guideline, Q2 (R1). CONCLUSIONS: All the observed DPs were new and formed by hydrolysis of an amide bond, phenyl ring hydroxylation and hydrolysis of the methoxy group of the phenyl ring. The despropyl process-related impurity was observed and well separated from the drug. The proposed UHPLC mass spectrometric method has greater utility in the identification of DPs in much less time with excellent selectivity.

2.
Rapid Commun Mass Spectrom ; 31(9): 771-781, 2017 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-28233930

RESUMEN

RATIONALE: Saquinavir mesylate (SQM) is an antiviral drug used for the treatment of HIV infections. The identification and characterization of all degradation products are essential for achieving the quality in pharmaceutical product development and also for patient safety. METHODS: The drug was subjected to hydrolytic (HCl, NaOH and water), oxidative (H2 O2 ), photolytic (UV and fluorescence light) and thermal (dry heat) forced degradation conditions as per ICH guidelines. The best chromatographic separation of the drug and all degradation products (DPs) was achieved on a CSH-Phenyl Hexyl column (100 × 2.1 mm, 1.7 µm) with ammonium acetate (10 mM, pH 5.0) and methanol as mobile phase in gradient mode at a flow rate of 0.28 mL/min. RESULTS: Nine DPs were obtained under various forced degradation conditions. All the DPs were characterized by using ultra-high-performance liquid chromatography/electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UHPLC/ESI-QTOF MS/MS) and the degradation pathway of the drug was justified by mechanistic explanations. The main DPs were formed by amide hydrolysis, conversion into diastereomers, an N-oxide and dehydration as well as oxidation of the alcohol from the drug. The method was validated and can be used in a quality control (QC) laboratory to assure the quality of SQM in bulk and finished formulations. CONCLUSIONS: A simple UHPLC/photodiode array (PDA) method was developed and successfully transferred to UHPLC/ESI-Q-TOF MS/MS for the identification and characterization of DPs. Very interestingly, diastereomeric DPs were obtained and successfully resolved by the chromatographic method. Copyright © 2017 John Wiley & Sons, Ltd.

3.
Biomed Chromatogr ; 31(7)2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27943342

RESUMEN

Acotiamide hydrochloride (ACT) is a drug used for the treatment of functional dyspepsia. Understanding which metabolites are likely to be formed in vivo is essential for interpreting pharmacology, pharmacokinetic and toxicology data. The metabolism of ACT has been investigated using a specific and sensitive liquid chromatography positive ion electrospray ionization high-resolution tandem mass spectrometry method. In vivo samples including rat plasma, urine and feces were collected separately after dosing healthy Sprague-Dawley rats at a dose of 20 mg kg -1 ACT at different time points up to 24 h. The metabolites were enriched by optimized sample preparation involving protein precipitation using acetonitrile followed by solid-phase extraction. The mass defect filter technique was used for better detection of both predicted and unexpected drug metabolites with the majority of interference ions removed. The structural elucidation of the metabolites was performed by comparing their [M + H]+ ions and their product ions with those of the parent drug. As a result, a total of seven hitherto unknown metabolites were characterized from the biosamples. The only phase I metabolite detected was N-despropyl acotiamide, whereas six phase II glucuronide conjugate metabolites were identified.


Asunto(s)
Benzamidas/metabolismo , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Tiazoles/metabolismo , Animales , Masculino , Ratas , Ratas Sprague-Dawley
4.
Biomed Chromatogr ; 30(3): 363-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26153099

RESUMEN

A novel, sensitive and selective ultra-high-performance liquid chromatography-electrospray ionization mass spectrometry method was developed and validated for the quantification of acotiamide (ACT), a first-in-class drug used in functional dyspepsia, in rat plasma. A simple protein precipitation method with acetonitrile as precipitating solvent was used to extract ACT from rat plasma. ACT and an internal standard (mirabegron, IS) were separated on an Agilent poroshell EC C18 column (50 × 3.0 mm, 2.7 µm) using methanol-10 mM ammonium acetate binary gradient mobile phase at a flow rate of 0.4 mL/min over 4 min run time. Detection was performed using target ions of [M + H](+) at m/z 451.2010 for ACT and m/z 397.1693 for IS in selective ion mode. The method was validated in the calibration range of 1.31-1000 ng/mL. All the validation parameters were well within the limits. The method demonstrated good performances in terms of intra- and inter-day precision (3.27-12.60% CV) and accuracy (87.96-104.94%). Thus the present ultra-high-pressure liquid chromatograhy-high-resolution mass spectrometry method for determination of ACT in rat plasma, is highly sensitive and rapid with a short run-time of 4 min, can be suitable for high sample throughput and for large batches of biological samples in pharmacokinetic studies. This method can be extended to measure plasma concentrations of ACT in humans to understand drug metabolism, drug interaction and adverse effects.


Asunto(s)
Benzamidas/sangre , Benzamidas/farmacocinética , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas/métodos , Tiazoles/sangre , Tiazoles/farmacocinética , Animales , Benzamidas/química , Estabilidad de Medicamentos , Modelos Lineales , Masculino , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tiazoles/química
5.
Rapid Commun Mass Spectrom ; 29(15): 1437-47, 2015 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-26147484

RESUMEN

RATIONALE: Azilsartan medoxomil potassium (AZM) is a new antihypertensive drug introduced in the year 2011. The presence of degradation products not only affects the quality, but also the safety aspects of the drug. Thus, it is essential to develop an efficient analytical method which could be useful to selectively separate and identify the degradation products of azilsartan medoxomil potassium. METHODS: AZM was subjected to forced degradation under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions. Separation of the drug and degradation products was achieved by a liquid chromatography (LC) method using an Acquity UPLC(®) C18 CSH column with mobile phase consisting of 0.02% trifluoroacetic acid and acetonitrile using a gradient method. Identification and characterization of the degradation products was carried out using LC/electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-QTOFMS). RESULTS: A total of five degradation products (DP 1 to DP 5) were formed under various stress conditions and their structures were proposed with the help of tandem mass spectrometry (MS/MS) experiments and accurate mass data. A common degradation product (DP 4) was observed under all the degradation conditions. DP 1, DP 2 and DP 5 were observed under acid hydrolytic conditions whereas DP 3 was observed under alkaline conditions. CONCLUSIONS: AZM was found to degrade under hydrolytic, oxidative and photolytic stress conditions. The structures of all the degradation products were proposed. The degradation pathway for the formation of degradation products was also hypothesized. A selective method was developed to quantify the drug in the presence of degradation products which is useful to monitor the quality of AZM.


Asunto(s)
Bencimidazoles/análisis , Bencimidazoles/química , Cromatografía Liquida/métodos , Oxadiazoles/análisis , Oxadiazoles/química , Espectrometría de Masas en Tándem/métodos , Hidrólisis , Estrés Oxidativo
6.
J Sep Sci ; 38(19): 3354-62, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26235225

RESUMEN

Quality-by-design-based methods hold greater level of confidence for variations and greater success in method transfer. A quality-by-design-based ultra high performance liquid chromatography method was developed for the simultaneous assay of sumatriptan and naproxen along with their related substances. The first screening was performed by fractional factorial design comprising 44 experiments for reversed-phase stationary phases, pH, and organic modifiers. The results of screening design experiments suggested phenyl hexyl column and acetonitrile were the best combination. The method was further optimized for flow rate, temperature, and gradient time by experimental design of 20 experiments and the knowledge space was generated for effect of variable on response (number of peaks ≥ 1.50 - resolution). Proficient design space was generated from knowledge space by applying Monte Carlo simulation to successfully integrate quantitative robustness metrics during optimization stage itself. The final method provided the robust performance which was verified and validated. Final conditions comprised Waters® Acquity phenyl hexyl column with gradient elution using ammonium acetate (pH 4.12, 0.02 M) buffer and acetonitrile at 0.355 mL/min flow rate and 30°C. The developed method separates all 13 analytes within a 15 min run time with fewer experiments compared to the traditional quality-by-testing approach.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Naproxeno/análisis , Sumatriptán/análisis , Cromatografía Líquida de Alta Presión/normas , Cromatografía Líquida de Alta Presión/estadística & datos numéricos , Combinación de Medicamentos , Contaminación de Medicamentos , Humanos , Método de Montecarlo , Naproxeno/administración & dosificación , Control de Calidad , Sumatriptán/administración & dosificación , Comprimidos/análisis
7.
J Pharm Biomed Anal ; 115: 388-94, 2015 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-26279369

RESUMEN

Fingolimod (FGL), an immunomodulator drug for treating multiple sclerosis, was subjected to hydrolysis (acidic, alkaline and neutral), oxidation, photolysis and thermal stress, as per International Conference on Harmonization specified conditions. The drug showed extensive degradation under base hydrolysis, however, it was stable under all other conditions. A total of three degradation products (DPs) were observed. The chromatographic separation of the drug and its degradation products was achieved on a Fortis C18 (100×2.1mm, 1.7µm) column with a mobile phase composed of 0.1% formic acid (Solvent A) and acetonitrile (Solvent B) in gradient mode. All the DPs were identified and characterized by liquid chromatography-quadrupole time of flight-mass spectrometry (LC-Q-TOF-MS) in combination with accurate mass measurements. The major DP was isolated and characterized by Nuclear Magnetic resonance spectroscopy. This is a typical case of degradation where acetonitrile used as co-solvent in stress studies, reacts with FGL in base hydrolytic conditions to produce acetylated DPs. Hence, it can be suggested that acetonitrile is not preferable as a co-solvent for stress degradation of FGL. The developed UHPLC method was validated as per ICH guidelines.


Asunto(s)
Cromatografía Liquida/métodos , Clorhidrato de Fingolimod/química , Factores Inmunológicos/química , Espectroscopía de Protones por Resonancia Magnética , Solventes/química , Espectrometría de Masas en Tándem , Tecnología Farmacéutica/métodos , Acetonitrilos/química , Estabilidad de Medicamentos , Formiatos/química , Calor , Concentración de Iones de Hidrógeno , Hidrólisis , Estructura Molecular , Oxidación-Reducción , Fotólisis , Reproducibilidad de los Resultados
8.
J Pharm Biomed Anal ; 102: 353-65, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25459935

RESUMEN

The present study reports the degradation behavior of a new antidepressant drug, vilazodone, under various stress conditions as per International Conference on Harmonization guidelines (ICH, Q1A(R2). The investigation involved monitoring decomposition of the drug under hydrolytic (acidic, basic and neutral), oxidative, photolytic and thermal stress conditions and identifying degradation products. A rapid, precise, accurate and robust ultra high performance liquid chromatography (UPLC) method has been developed on a Waters CSH Phenyl-Hexyl column (100 mm × 2.1 mm, 1.7 µm) using gradient elution of 10mM ammonium acetate buffer (pH 5.0) and acetonitrile as mobile phase. The drug was found to be degraded in hydrolytic (acidic and basic) and oxidative conditions, whereas it was stable under neutral hydrolytic, photolytic and thermal stress conditions. The method was extended to quadrupole time-of-flight mass spectrometry (QTOF-MS) for the structural characterization of degradation products. It has been observed that isomeric N-oxide degradation products were formed under oxidative stress condition. The exact location of N-oxidation in the drug was investigated using atmospheric pressure chemical ionization (APCI) due to the formation of characteristic fragment ions. These fragment ions resulted from Meisenheimer rearrangement owing to thermal energy activation at the vaporizer of APCI source. All degradation products were comprehensively characterized by UPLC-ESI-MS/MS and UPLC-APCI-MS experiments. The most probable mechanisms for the formation of degradation products have also been proposed. The method was validated in terms of specificity, linearity, accuracy, precision, and robustness as per ICH guidelines.


Asunto(s)
Benzofuranos/análisis , Benzofuranos/metabolismo , Indoles/análisis , Indoles/metabolismo , Piperazinas/análisis , Piperazinas/metabolismo , Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masas en Tándem/métodos , Benzofuranos/química , Cromatografía Liquida/métodos , Hidrólisis , Indoles/química , Isomerismo , Piperazinas/química , Clorhidrato de Vilazodona
9.
J Mass Spectrom ; 50(11): 1222-33, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26505767

RESUMEN

Tinoridine is a nonsteroidal anti-inflammatory drug and also has potent radical scavenger and antiperoxidative activity. However, metabolism of tinoridine has not been thoroughly investigated. To identify in vivo metabolites, the drug was administered to Sprague-Dawley rats (n = 5) at a dose of 20 mg kg(-1), and blood, urine and feces were collected at different time points up to 24 h. In vitro metabolism was delved by incubating the drug with rat liver microsomes and human liver microsomes. The metabolites were enriched by optimized sample preparation involving protein precipitation using acetonitrile, followed by solid-phase extraction. Data processes were carried out using multiple mass defects filters to eliminate false-positive ions. A total of 11 metabolites have been identified in urine samples including hydroxyl, dealkylated, acetylated and glucuronide metabolites; among them, some were also observed in plasma and feces samples. Only two major metabolites were formed using liver microsomal incubations. These metabolites were also observed in vivo. All the 11 metabolites, which are hitherto unknown and novel, were characterized by using ultrahigh-performance liquid chromatography-quadrupole time-of-flight tandem mass spectrometry in combination with accurate mass measurements. Finally, in silico toxicological screening of all metabolites was evaluated, and two metabolites were proposed to show a certain degree of lung or liver toxicity.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Tienopiridinas/análisis , Tienopiridinas/farmacocinética , Administración Oral , Animales , Antiinflamatorios no Esteroideos/análisis , Antiinflamatorios no Esteroideos/metabolismo , Antiinflamatorios no Esteroideos/farmacocinética , Antiinflamatorios no Esteroideos/toxicidad , Simulación por Computador , Heces , Femenino , Humanos , Masculino , Ratones , Microsomas Hepáticos/efectos de los fármacos , Microsomas Hepáticos/metabolismo , Estructura Molecular , Ratas Sprague-Dawley , Programas Informáticos , Extracción en Fase Sólida , Espectrometría de Masa por Ionización de Electrospray/métodos , Tienopiridinas/metabolismo , Tienopiridinas/toxicidad , Pruebas de Toxicidad/métodos
10.
J Mass Spectrom ; 50(7): 918-28, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26349647

RESUMEN

Pazopanib (PZ), an anti-cancer drug, was subjected to forced degradation under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions as per International Conference on Harmonization guidelines. A selective stability indicating validated method was developed using a Waters Acquity UPLC HSS T3 (100 × 2.1 mm, 1.7 µm) column in gradient mode with ammonium acetate buffer (10 mM, pH 5.0) and acetonitrile. PZ was found to degrade only in photolytic conditions to produce six transformation products (TPs). All the TPs were identified and characterized by liquid chromatography/atmospheric pressure chemical ionization-quadrupole-time of flight mass spectrometry experiments in combination with accurate mass measurements. Plausible mechanisms have been proposed for the formation of TPs. In silico toxicity was predicted using TOPKAT and DEREK softwares for all the TPs. The TP, N4-(2,3-dimethyl-2H-indazol-6-yl)-N4-methylpyrimidine-2,4-diamine, was found to be genotoxic, whereas all other TPs with sulfonamide moiety were hepatotoxic. The data reported here are expected to be of significance as this study foresees the formation of one potential genotoxic and five hepatotoxic degradation/transformation products.


Asunto(s)
Mutágenos/química , Mutágenos/toxicidad , Pirimidinas/química , Pirimidinas/toxicidad , Sulfonamidas/química , Sulfonamidas/toxicidad , Animales , Cromatografía Líquida de Alta Presión/métodos , Simulación por Computador , Estabilidad de Medicamentos , Femenino , Indazoles , Límite de Detección , Masculino , Ratones , Ratas , Reproducibilidad de los Resultados , Espectrometría de Masa por Ionización de Electrospray/métodos
11.
J Mass Spectrom ; 50(2): 344-53, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25800016

RESUMEN

A validated stability-indicating HPLC method was established, and comprehensive stress testing of ivabradine, a cardiotonic drug, was carried out as per ICH guidelines. Ivabradine was subjected to acidic, basic and neutral hydrolysis, oxidation, photolysis and thermal stress conditions, and the resulting degradation products were investigated by LC-PDA and LC-HR-MS/MS. The drug was found to degrade in acid and base hydrolysis. An efficient and selective stability assay method was developed on Phenomenex Luna C18 (250 × 4.6 mm, 5.0 µm) column using ammonium formate (10 mM, pH 3.0) and acetonitrile as mobile phase at 30 °C in gradient elution mode. The flow rate was 0.7 ml/min and detection wavelength was 286 nm. A total of five degradation products (I-1 to I-5) were identified and characterized by LC-HR-MS/MS in combination with accurate mass measurements. The drug exhibited different degradation behaviour in HCl and H2SO4 hydrolysis conditions. It is a unique example where two of the five degradation products in HCl hydrolysis were absent in H2SO4 acid hydrolysis. The present study provides guidance to revise the stress test for the determination of inherent stability of drugs containing lactam moiety under hydrolytic conditions. Most probable mechanisms for the formation of degradation products have been proposed on the basis of a comparison of the fragmentation pattern of the drug and its degradation products. In silico toxicity revealed that the degradation products (I-2 to I-5) were found to be severe irritants in case of ocular irritancy. The analytical assay method was validated with respect to specificity, linearity, range, precision, accuracy and robustness.


Asunto(s)
Benzazepinas/química , Cromatografía Liquida/métodos , Ácido Clorhídrico/química , Ácidos Sulfúricos/química , Espectrometría de Masas en Tándem/métodos , Simulación por Computador , Estabilidad de Medicamentos , Calor , Hidrólisis , Ivabradina , Oxidación-Reducción , Reproducibilidad de los Resultados
12.
Chem Biol Interact ; 240: 146-52, 2015 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-26282489

RESUMEN

There has been a search for new anticancer agents to treat cancer resistance throughout the globe. Salinomycin (SAL), a broad spectrum antibiotic and a coccidiostat has been found to counter tumour resistance and kill cancer stem cells with better efficacy than the existing chemotherapeutic agents; paclitaxel and doxorubicin. This refocused its importance for treatment of human cancers. In this study, we studied the in vitro drug metabolism and pharmacokinetic parameters of SAL. SAL undergoes rapid metabolism in liver microsomes and has a high intrinsic clearance. SAL metabolism is mainly mediated by CYP enzymes; CYP3A4 the major enzyme metabolising SAL. The percent plasma protein binding of SAL in human was significantly lower as compared to mouse and rat plasma. CYP inhibition was carried out by chemical inhibition and recombinant enzyme studies. SAL was found to be a moderate inhibitor of CYP2D6 as well as CYP3A4. As CYP3A4 was the major enzyme responsible for metabolism of SAL, in vivo pharmacokinetic study in rats was done to check the effect of concomitant administration of Ketoconazole (KTC) on SAL pharmacokinetics. KTC, being a selective CYP3A4 inhibitor increased the systemic exposure of SAL significantly to 7-fold in AUC0-α and 3-fold increase in Cmax of SAL in rats with concomitant KTC administration.


Asunto(s)
Sistemas de Liberación de Medicamentos , Células Madre Neoplásicas/efectos de los fármacos , Piranos/farmacología , Piranos/farmacocinética , Animales , Antineoplásicos/química , Antineoplásicos/farmacocinética , Antineoplásicos/farmacología , Relación Dosis-Respuesta a Droga , Evaluación Preclínica de Medicamentos , Humanos , Masculino , Ratones , Microsomas Hepáticos/efectos de los fármacos , Piranos/química , Ratas , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA