Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(29): 2604-2616, 2024 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-38759110

RESUMEN

BACKGROUND AND AIMS: Patterns of atrial fibrillation (AF) recurrence post-catheter ablation for persistent AF (PsAF) are not well described. This study aimed to describe the pattern of AF recurrence seen following catheter ablation for PsAF and the implications for healthcare utilization and quality of life (QoL). METHODS: This was a post-hoc analysis of the CAPLA study, an international, multicentre study that randomized patients with symptomatic PsAF to pulmonary vein isolation plus posterior wall isolation or pulmonary vein isolation alone. Patients underwent twice daily single lead ECG, implantable device monitoring or three monthly Holter monitoring. RESULTS: 154 of 333 (46.2%) patients (median age 67.3 years, 28% female) experienced AF recurrence at 12-month follow-up. Recurrence was paroxysmal in 97 (63%) patients and persistent in 57 (37%). Recurrence type did not differ between randomization groups (P = .508). Median AF burden was 27.4% in PsAF recurrence and .9% in paroxysmal AF (PAF) recurrence (P < .001). Patients with PsAF recurrence had lower baseline left ventricular ejection fraction (PsAF 50% vs. PAF 60%, P < .001) and larger left atrial volume (PsAF 54.2 ± 19.3 mL/m² vs. PAF 44.8 ± 11.6 mL/m², P = .008). Healthcare utilization was significantly higher in PsAF (45 patients [78.9%]) vs. PAF recurrence (45 patients [46.4%], P < .001) and lowest in those without recurrence (17 patients [9.5%], P < .001). Patients without AF recurrence had greater improvements in QoL as assessed by the Atrial Fibrillation Effect on Quality-of-Life (AFEQT) questionnaire (Δ33.3 ± 25.2 points) compared to those with PAF (Δ24.0 ± 25.0 points, P = .012) or PsAF (Δ13.4 ± 22.9 points, P < .001) recurrence. CONCLUSIONS: AF recurrence is more often paroxysmal after catheter ablation for PsAF irrespective of ablation strategy. Recurrent PsAF was associated with higher AF burden, increased healthcare utilization and antiarrhythmic drug use. The type of AF recurrence and AF burden may be considered important endpoints in clinical trials investigating ablation of PsAF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Calidad de Vida , Recurrencia , Humanos , Fibrilación Atrial/cirugía , Femenino , Masculino , Ablación por Catéter/métodos , Anciano , Persona de Mediana Edad , Venas Pulmonares/cirugía , Electrocardiografía Ambulatoria , Aceptación de la Atención de Salud/estadística & datos numéricos , Resultado del Tratamiento
2.
Heart Lung Circ ; 33(6): 828-881, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38702234

RESUMEN

Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Australia , Cardiología/normas , Ablación por Catéter/métodos , Ablación por Catéter/normas , Nueva Zelanda , Sociedades Médicas
3.
J Phys Chem A ; 127(29): 6071-6080, 2023 Jul 27.
Artículo en Inglés | MEDLINE | ID: mdl-37463028

RESUMEN

Cyclopropenone (HCCOCH, "CPN") is an exotic quasi-aromatic cyclic carbene that abounds in the interstellar medium (ISM). Astronomical observations suggest that (i) stagnate CPN exhibits a tendency to polymerize and that (ii) interactions may occur between CPN and water that is also ubiquitous in the ISM. In this light, density functional theory investigations reveal cooperative hydrogen bonding, which leads to stable polymeric conformations of (CPN)n, tracked up to n = 14. Stable agglomerations with water, however, constitute at best only two CPN and two water molecules, signifying that while CPN exhibits remarkable cooperativity for "cohesive" clustering via hydrogen bonding, this tendency is markedly diminished for "hetero"-interactions. Multifaceted data are employed to probe cogent molecular descriptors, such as structure and energetics of various conformers, vibrational spectroscopic response, molecular electrostatic potential (MESP), effective atomic charges: all these, in unison, describe the evolution of the characteristics upon cluster formation. Salient stretching frequency shifts, as well as charge redistribution gleaned from MESP morphology, have a direct bearing on variegated hydrogen bonding patterns: linear, nonlinear, as well as bifurcated. In particular, characteristic C-H, C═O stretching, and O-H vibrations in the water complexes reveal a "softening" (downshift) of frequencies. While small conformers have markedly distinct MESP variations, the differences become less pronounced with incremental clustering, an effect substantiated by corresponding emergent atomic charges.

4.
JAMA ; 329(2): 127-135, 2023 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-36625809

RESUMEN

Importance: Pulmonary vein isolation (PVI) alone is less effective in patients with persistent atrial fibrillation (AF) compared with paroxysmal AF. The left atrial posterior wall may contribute to maintenance of persistent AF, and posterior wall isolation (PWI) is a common PVI adjunct. However, PWI has not been subjected to randomized comparison. Objective: To compare PVI with PWI vs PVI alone in patients with persistent AF undergoing first-time catheter ablation. Design, Setting, and Participants: Investigator initiated, multicenter, randomized clinical trial involving 11 centers in 3 countries (Australia, Canada, UK). Symptomatic patients with persistent AF were randomized 1:1 to either PVI with PWI or PVI alone. Patients were enrolled July 2018-March 2021, with 1-year follow-up completed March 2022. Interventions: The PVI with PWI group (n = 170) underwent wide antral pulmonary vein isolation followed by posterior wall isolation involving linear ablation at the roof and floor to achieve electrical isolation. The PVI-alone group (n = 168) underwent wide antral pulmonary vein isolation alone. Main Outcomes and Measures: Primary end point was freedom from any documented atrial arrhythmia of more than 30 seconds without antiarrhythmic medication at 12 months, after a single ablation procedure. The 23 secondary outcomes included freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures, freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures, AF burden between study groups at 12 months, procedural outcomes, and complications. Results: Among 338 patients randomized (median age, 65.6 [IQR, 13.1] years; 76.9% men), 330 (97.6%) completed the study. After 12 months, 89 patients (52.4%) assigned to PVI with PWI were free from recurrent atrial arrhythmia without antiarrhythmic medication after a single procedure, compared with 90 (53.6%) assigned to PVI alone (between-group difference, -1.2%; hazard ratio [HR], 0.99 [95% CI, 0.73-1.36]; P = .98). Of the secondary end points, 9 showed no significant difference, including freedom from atrial arrhythmia with/without antiarrhythmic medication after multiple procedures (58.2% for PVI with PWI vs 60.1% for PVI alone; HR, 1.10 [95% CI, 0.79-1.55]; P = .57), freedom from symptomatic AF with/without antiarrhythmic medication after multiple procedures (68.2% vs 72%; HR, 1.20 [95% CI, 0.80-1.78]; P = .36) or AF burden (0% [IQR, 0%-2.3%] vs 0% [IQR, 0%-2.8%], P = .47). Mean procedural times (142 [SD, 69] vs 121 [SD, 57] minutes, P < .001) and ablation times (34 [SD, 21] vs 28 [SD, 12] minutes, P < .001) were significantly shorter for PVI alone. There were 6 complications for PVI with PWI and 4 for PVI alone. Conclusions and Relevance: In patients undergoing first-time catheter ablation for persistent AF, the addition of PWI to PVI alone did not significantly improve freedom from atrial arrhythmia at 12 months compared with PVI alone. These findings do not support the empirical inclusion of PWI for ablation of persistent AF. Trial Registration: anzctr.org.au Identifier: ACTRN12616001436460.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Femenino , Humanos , Masculino , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/cirugía , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento , Persona de Mediana Edad , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos
5.
Am Heart J ; 243: 210-220, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34619143

RESUMEN

BACKGROUND: The success of pulmonary vein isolation (PVI) is reduced in persistent AF (PsAF) compared to paroxysmal AF. Adjunctive ablation strategies have failed to show consistent incremental benefit over PVI alone in randomized studies. The left atrial posterior wall is a potential source of non-PV triggers and atrial substrate which may promote the initiation and maintenance of PsAF. Adding posterior wall isolation (PWI) to PVI had shown conflicting outcomes, with earlier studies confounded by methodological limitations. OBJECTIVES: To determine whether combining PWI with PVI significantly improves freedom from AF recurrence, compared to PVI alone, in patients with PsAF. METHODS: This is a multi-center, prospective, international randomized clinical trial. 338 patients with symptomatic PsAF refractory to anti-arrhythmic therapy (AAD) will be randomized to either PVI alone or PVI with PWI in a 1:1 ratio. PVI involves wide antral circumferential pulmonary vein (PV) isolation, utilizing contact force sensing ablation catheters. PWI involves the creation of a floor line connecting the inferior aspect of the PVs, and a roof line connecting the superior aspect of the PVs. Follow up is for a minimum of 12 months with rhythm monitoring via implantable cardiac device and/or loop monitor, or frequent intermittent monitoring with an ECG device. The primary outcome is freedom from any documented atrial arrhythmia of > 30 seconds off AAD at 12 months, after a single ablation procedure. CONCLUSIONS: This randomized study aims to determine the success and safety of adjunctive PWI to PVI in patients with persistent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Humanos , Estudios Prospectivos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
6.
J Phys Chem A ; 126(34): 5721-5728, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35998414

RESUMEN

Cyclopropenylidene (c-C3H2, abbreviated CPD) is a highly reactive, planar, partially aromatic carbene discovered in the interstellar medium, and, also recently, in the outer solar system. It is demonstrated herein on cogent quantum chemical grounds that CPD which possesses an electric dipole moment of 3.4 D is capable of forming stable dimer and trimer clusters through hydrogen-bonding. These attributes of CPD are conducive to the formation of stable hydrogen-bonded conformations with one- and two-water molecules. Having determined its consistency with the second-order Møller-Plesset perturbation theory MP2, we employ the ωB97xD hybrid density functional theory in conjunction with a 6-311++G(2d,2p) basis set for a credible description of noncovalent interactions involved in clustering. Molecular electrostatic potential (MESP) and characteristic vibrational frequency shifts upon clustering are presented.

7.
J Phys Chem A ; 124(5): 943-954, 2020 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-31877045

RESUMEN

One-electron properties for molecules such as electron density, electrostatic potential (ESP), and electron momentum density (EMD) are experimentally tractable quantities, useful in understanding chemical characteristics. In this work, effects of a uniform homogeneous external electric field on some characteristic one-electron properties of simple molecules are analyzed. EMDs and ESPs were used to understand the response of water, hydrogen fluoride, carbon monoxide, chloroacetylene, and ammonia in an electric field. Remarkably, the EMD maxima for these molecules get rotated as the electric field strength is varied. A greater order of change in EMD than in ESP with increasing electric field strength brings out the sensitivity of the EMDs, especially for the valence electronic region, which in the momentum space is mapped onto the vicinity of its origin. The eigenvectors of the EMD Hessian maxima at the momentum-space origin are seen to rotate as a function of increasing field strength, with the extra angular momentum imparted by the field manifesting itself as reconfiguration of the EMD distribution. In the presence of the field, valence states may couple with higher electronic states, leading to a mixing of the states resulting in avoided crossings as a function of the field strength. The avoided crossings legitimately estimate maximal field strength limits for the calculation, prior to ionization.

8.
J Electrocardiol ; 60: 118-125, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32361086

RESUMEN

BACKGROUND: Implantable Cardiac Monitors (ICMs) are used for long-term monitoring of arrhythmias. BIOMONITOR III is a novel ICM with a miniaturized profile, long sensing vector due to a flexible antenna, simplified implantation with a dedicated insertion tool for pocket formation and ICM placement in a single step, and daily automatic Home Monitoring (HM) function. METHODS: In 47 patients undergoing BIOMONITOR III insertion for any ICM indication, 16 investigators at 10 Australian sites assessed handling characteristics of the insertion tool, R-wave amplitudes, noise burden, P-wave visibility, and HM transmission success. Patients were followed for 1 month. RESULTS: All 47 attempted insertions were successful. Median time from skin incision to removal of the insertion tool after ICM insertion was 39 s (IQR 19-65) and to wound closure and cleaning was 4.7 min (IQR 3.5-7.8). All aspects of the insertion tool were rated as "good" or "excellent" in ≥97.9% and "fair" in ≤2.1% of patients, except for "force needed for tunnelling" (91.5% good/excellent, 8.5% fair). Based on HM data, R-waves in the first month were stable at 0.70 ± 0.37 mV. Median noise burden (disabling automatic rhythm evaluation) was 0.19% (IQR 0.00-0.93), equivalent to 2.7 min (IQR 0.0-13.4) per day. In HM-transmitted ECG strips with regular sinus rhythm, P-waves were visible in 89 ± 24% of heart cycles. Patient-individual automatic Home Monitoring transmission success was 98.0% ± 5.5%. CONCLUSIONS: The novel ICM performed well in all aspects studied, including fast insertion, reliable R-wave sensing, good P-wave visibility, and highly successful HM transmissions.


Asunto(s)
Electrocardiografía Ambulatoria , Electrocardiografía , Arritmias Cardíacas/diagnóstico , Australia , Humanos
9.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32451232

RESUMEN

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Pandemias , Neumonía Viral , Australia/epidemiología , COVID-19 , Infecciones por Coronavirus/epidemiología , Infecciones por Coronavirus/fisiopatología , Infecciones por Coronavirus/terapia , Humanos , Neumonía Viral/epidemiología , Neumonía Viral/fisiopatología , Neumonía Viral/terapia , SARS-CoV-2
10.
Eur Heart J ; 39(31): 2859-2866, 2018 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-30020440

RESUMEN

Sudden cardiac death (SCD) accounts for approximately one-third of all deaths among patients with non-ischaemic cardiomyopathy (NICM). Implantable cardioverter-defibrillator (ICD) therapy has been the primary intervention for managing individuals at high risk for SCD. However, individual ICD trials in the NICM population have failed to demonstrate a mortality benefit with prophylactic ICD implantation. Current guidelines recommend ICD implantation in NICM patients with symptomatic heart failure and a left ventricular ≤35% and are based on meta-analyses of multiple trials that span three decades and include the recent Danish Study to Assess the Efficacy of ICDs in Patients with Non-ischaemic Heart Failure on Mortality (DANISH) trial. These pooled analyses report a significant reduction in all-cause mortality with ICD implantation compared with medical therapy alone. In addition, each of these trials has demonstrated consistently a reduction in the risk of SCD compared with medical therapy alone. As a result, a refined approach of risk stratification that selects patients at the highest risk for SCD may lead to a significant improvement in ICD efficacy. In this clinical review, we first discuss the evolution of clinical trials that have evaluated ICDs in the NICM population. We then highlight some key markers of arrhythmia risk that hold promise in personalizing risk stratification for SCD.


Asunto(s)
Arritmias Cardíacas/prevención & control , Cardiomiopatías/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Prevención Primaria , Arritmias Cardíacas/etiología , Cardiomiopatías/genética , Cardiomiopatías/fisiopatología , Marcadores Genéticos , Humanos , Medición de Riesgo , Remodelación Ventricular
11.
Heart Lung Circ ; 28(1): 102-109, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30554597

RESUMEN

Ventricular arrhythmias (VA) are observed in the setting of structural heart disease. However, in a proportion of patients presenting with VT, the routine diagnostic modalities fail to demonstrate overt myocardial abnormality. These arrhythmias have been called idiopathic VAs. They consist of various subtypes that have been defined by their anatomic location of origin within the heart and/or their underlying mechanism. While the majority of patients are asymptomatic, some experience debilitating symptoms and may develop reversible ventricular dysfunction. Catheter ablation has been traditionally reserved for patients with incapacitating symptoms or progressive ventricular dysfunction. However, as many patients are young, and catheter ablation can be curative in >90% of cases with a low risk (<1%) of serious complications, it is increasingly being offered as a first-line treatment in symptomatic patients. The approach to arrhythmia mapping is guided by the 12-lead electrocardiograph (ECG) morphology of the ventricular tachycardia (VT). Use of three dimensional (3D) electroanatomic mapping systems and intra-cardiac echocardiography are helpful in localising sites for successful ablation.


Asunto(s)
Ablación por Catéter/métodos , Electrocardiografía , Sistema de Conducción Cardíaco/cirugía , Taquicardia Ventricular/cirugía , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 29(12): 1654-1663, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30106213

RESUMEN

BACKGROUND: Catheter ablation of ventricular arrhythmias (VA) from the papillary muscles (PM) is challenging due to limited catheter stability and contact on the PMs with their anatomic complexity and mobility. OBJECTIVE: This study aimed to evaluate the effectiveness of cryoablation as an adjunctive therapy for PM VAs when radiofrequency (RF) ablation has failed. METHODS: We evaluated a retrospective series of patients who underwent cryoablation for PM VAs when RF ablation had failed. The decision to switch to cryoablation was at the operator's discretion when intracardiac echocardiography (ICE) suggested that cryoablation might be more effective in achieving catheter stability and energy delivery. RESULTS: Sixteen patients underwent cryoablation of PM VAs between 2014 and 2016 after RF ablation was unsuccessful. VAs originated from the anterolateral left ventricle (LV) PM (six patients), posterolateral LV PM (six patients), and right ventricle PM (four patients). VAs were predominantly frequent premature ventricular complexes (PVCs); however, patients with sustained ventricular tachycardia and PVC-triggered VF were also represented. Fifteen of the 16 patients were treated with cryoablation; in one patient, a procedural complication with retrograde aortic access precluded treatment. In all patients treated with cryoablation, contact and stability was confirmed with ICE to be superior to the RF catheter, and there was acute and long-term elimination of VAs. CONCLUSION: Cryoablation is a useful adjunctive therapy in ablation of PM VAs, providing excellent procedural outcomes even when RF ablation has failed. Cryoablation catheters are less maneuverable than RF ablation catheters and care is required to avoid complications.


Asunto(s)
Ablación por Catéter/métodos , Criocirugía/métodos , Músculos Papilares/diagnóstico por imagen , Músculos Papilares/cirugía , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Intraoperatorio/métodos , Estudios Retrospectivos , Taquicardia Ventricular/fisiopatología , Insuficiencia del Tratamiento , Adulto Joven
13.
J Cardiovasc Electrophysiol ; 29(6): 823-832, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29513397

RESUMEN

INTRODUCTION: Whether successful catheter ablation for atrial fibrillation (AF) reduces risk of cerebrovascular events (CVEs) remains controversial and whether oral anticoagulation therapy (OAT) can be safely discontinued in patients rendered free of AF recurrences remains unknown. We evaluated OAT use patterns and examined long-term rates of CVEs (stroke/TIA) and major bleeding episodes (MBEs) in patients with nonparoxysmal AF treated with catheter ablation. METHODS AND RESULTS: Four hundred patients with nonparoxysmal AF (200 persistent, 200 longstanding persistent; mean age 60.3 ± 9.7 years, 82% male) undergoing first AF ablation were followed for 3.6 ± 2.4 years. OAT discontinuation during follow-up was permitted in selected patients per physician discretion. At last follow-up, allowing for multiple ablations, 172 (43.0%) patients were free of AF recurrence. Two hundred and seven (51.8%) discontinued OAT at some point; 174 (43.5%) were off OAT at last follow-up. Patients without AF recurrence were more likely to remain off OAT (HR 0.23 [95% CI 0.17-0.33]). Patients with persistent (versus longstanding persistent) AF type prior to ablation (HR 0.6 [CI 0.44-0.83]) and those with CHA2 DS2 -VASc score <2 (HR 0.56 [0.39-0.80]) were less likely to continue OAT. Seven patients had CVEs (incidence: 0.49/100 patient years) and 14 experienced MBE during follow-up (incidence: 0.98/100 patient years). Older age (P  =  0.001) and coronary artery disease (P  =  0.028) were associated with CVE. CONCLUSION: Anticoagulation discontinuation in well selected, closely monitored patients following successful ablation of nonparoxysmal AF was associated with a low rate of clinical embolic CVEs. Prospective studies are required to confirm safety of OAT discontinuation after successful AF ablation.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Ablación por Catéter , Ataque Isquémico Transitorio/prevención & control , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Anciano de 80 o más Años , Anticoagulantes/efectos adversos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Esquema de Medicación , Femenino , Hemorragia/inducido químicamente , Humanos , Ataque Isquémico Transitorio/diagnóstico , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/fisiopatología , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/fisiopatología , Factores de Tiempo
14.
Europace ; 20(12): 1929-1935, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29912366

RESUMEN

Aims: Atrial fibrillation (AF) is a progressive disease. Obesity is associated with progression of AF. This study evaluates the impact of weight and risk factor management (RFM) on progression of the AF. Methods and results: As described in the Long-Term Effect of Goal-Directed Weight Management in an Atrial Fibrillation Cohort: A Long-Term Follow-Up (LEGACY) Study, of 1415 consecutive AF patients, 825 had body mass index ≥ 27 kg/m2 and were offered weight and RFM. After exclusion, 355 were included for analysis. Weight loss was categorized as: Group 1 (<3%), Group 2 (3-9%), and Group 3 (≥10%). Change in AF type was determined by clinical review and 7-day Holter yearly. Atrial fibrillation type was categorized as per the Heart Rhythm Society consensus. There were no differences in baseline characteristic or follow-up duration between groups (P = NS). In Group 1, 41% progressed from paroxysmal to persistent and 26% from persistent to paroxysmal or no AF. In Group 2, 32% progressed from paroxysmal to persistent and 49% reversed from persistent to paroxysmal or no AF. In Group 3, 3% progressed to persistent and 88% reversed from persistent to paroxysmal or no AF (P < 0.001). Increased weight loss was significantly associated with greater AF freedom: 45 (39%) in Group 1, 69 (67%) in Group 2, and 116 (86%) in Group 3 (P ≤ 0.001). Conclusion: Obesity is associated with progression of the AF disease. This study demonstrates the dynamic relationship between weight/risk factors and AF. Weight-loss management and RFM reverses the type and natural progression of AF.


Asunto(s)
Fibrilación Atrial/terapia , Obesidad/terapia , Pérdida de Peso , Técnicas de Ablación , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Índice de Masa Corporal , Estimulación Cardíaca Artificial , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Obesidad/fisiopatología , Supervivencia sin Progresión , Estudios Prospectivos , Recurrencia , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
15.
Europace ; 20(FI_3): f366-f376, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29267853

RESUMEN

Aims: Several techniques have been utilized for the ablation of persistent (P) and long-standing persistent (LsP) atrial fibrillation (AF); however, the best approach of substrate ablation remains poorly defined. This study aims to examine the impact of ablation approach on outcomes associated with P or LsP AF ablation by conducting a meta-analysis and regression on contemporary literature. Methods and results: A systematic literature review was conducted up to 29 July 2015 for scientific literature reporting on outcomes associated with P or LsP AF ablation. One hundred and thirteen studies reported outcomes in a total of 18 657 patients undergoing various ablation approaches for the treatment of P-LsP AF between 2001 and 2015. The point efficacy estimate of a single-AF ablation procedure without the use of anti-arrhythmic drugs was 43% (95% CI; 39-47%). Multiple procedures and/or the use of anti-arrhythmic drugs increase success to 69% (95% CI; 66-71%). Meta-regression revealed that ablation technique (P < 0.001) and left atrial size (P = 0.02) were predictive of single procedure, drug-free success. The addition of extra-pulmonary substrate approaches was associated with declining efficacy when compared to a pulmonary vein ablation alone. Conclusion: The efficacy of a single-AF ablation procedure for P or LsP AF is 43%; however, can be increased to 69% with the use of multiple procedures and/or anti-arrhythmic drugs. Current literature supports the finding that pulmonary vein antrum ablation/isolation is at least equivalently efficacious to other contemporary P-LsP ablation strategies.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Anciano , Antiarrítmicos/uso terapéutico , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación , Factores de Riesgo , Factores de Tiempo
16.
J Cardiovasc Electrophysiol ; 28(1): 115-119, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27569577

RESUMEN

Most premature ventricular contractions (PVCs) arise from the right or left ventricular outflow tract. Some VPCs originate near the His-bundle region. However, there remains a paucity of information on PVCs originating directly from the cardiac conduction system. We describe 2 cases with idiopathic frequent PVCs that were mapped directly to the left bundle branch itself. We also provide an anatomic-based mapping and ablation approach for management of these uncommon and challenging arrhythmias. In both cases we were able to either eliminate or significantly suppress the ectopic source by applying radiofrequency at this location without causing any significant impairment of the atrioventricular conduction.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Electrocardiografía , Complejos Prematuros Ventriculares/diagnóstico , Potenciales de Acción , Anciano , Fascículo Atrioventricular/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Valor Predictivo de las Pruebas , Resultado del Tratamiento , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/cirugía
17.
J Cardiovasc Electrophysiol ; 28(3): 280-288, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27997060

RESUMEN

INTRODUCTION: Bipolar voltage criteria to delineate left atrial (LA) scar have been derived using point-by-point (PBP) contact electroanatomical mapping. It remains unclear how PBP-derived LA scar correlates with multielectrode fast automated mapping (ME-FAM) derived scar. We aimed to correlate scar and bipolar voltages from LA maps created using PBP versus ME-FAM. METHODS AND RESULTS: In consecutive patients undergoing repeat AF ablation, 2 separate LA maps were created using PBP and ME-FAM during sinus rhythm before ablation. Contiguous areas in the LA with a bipolar voltage cutoff of ≤0.2 mV represented dense scar; LA scar percentage was calculated for each map. Each LA shell was divided into 9 regions and each region further subdivided into 4 quadrants for additional analysis; mean voltages of all points obtained using PBP versus ME-FAM in each region were compared. Forty maps (20 PBP: mean 228.5 ± 95.6 points; 20 ME-FAM: 923.0 ± 382.6 points) were created in 20 patients. Mapping time with ME-FAM was shorter compared with PBP (13.3 ± 5.3 vs. 34.4 ± 13.1 minutes; P < 0.001). Mean LA scar percentage was higher with PBP compared with ME-FAM (15.5 ± 17.1% vs. 12.8 ± 17.6%; P = 0.04). Mean PBP voltage distribution was lower (compared with ME-FAM) in the septum (0.95 ± 0.73 vs. 1.46 ± 0.99 mV; P = 0.009), posterior wall (0.84 ± 0.42 vs. 1.40 ± 0.83 mV; P = 0.0008), roof (0.78 ± 0.80 vs. 1.39 ± 1.09 mV; P = 0.0003), and right PV-LA junction (0.34 ± 0.25 vs. 0.59 ± 0.50 mV; P = 0.01) regions, while voltages were similar in all other LA regions (all P > 0.05). CONCLUSIONS: In AF patients undergoing repeat ablation, bipolar voltage is greater in certain LA segments with ME-FAM compared with PBP mapping.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Cicatriz/diagnóstico , Cicatriz/cirugía , Técnicas Electrofisiológicas Cardíacas/métodos , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/fisiopatología , Automatización , Ablación por Catéter/efectos adversos , Cicatriz/etiología , Cicatriz/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Reoperación
18.
J Cardiovasc Electrophysiol ; 28(10): 1179-1186, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28677887

RESUMEN

BACKGROUND: Most idiopathic ventricular arrhythmias (VAs) originate from the outflow tracts and are characterized by an inferior axis on the 12-lead ECG. A group of patients will exhibit inferior lead discordance (ILD), demonstrating a positive QRS in lead II with negative QRS in III or the opposite finding. METHODS AND RESULTS: We identified patients undergoing ablation of idiopathic premature ventricular contractions (PVCs) or ventricular tachycardia (VT) between 2013 and 2015. The site of earliest activation was determined using electroanatomic mapping and intracardiac echocardiography. Out of 281 patients, 25 (8.9%) exhibited ILD. In patients with positive/negative discordance (n = 18), the source was mapped to the parahisian region in 14 cases and to the right ventricular (RV) moderator band (MB) or papillary muscles (PMs) in 4, while all those with negative/positive discordance (n = 7) were mapped to the anterolateral PM (ALPM). In the group with positive/negative discordance, a later precordial transition (>V4), wider QRS duration, and the presence of notch in the inferior leads pointed toward a RV MB/PM origin. Complete PVC/VT suppression was achieved in 72%. In 2 patients with parahisian PVCs, ablation was not attempted due to risk of heart block. CONCLUSIONS: The presence of ILD is associated with particular anatomical locations, namely, the parahisian region, RV MB/PM, and ALPM. The outcomes of ablation are more modest compared to other idiopathic VAs, reflecting the technical difficulties associated with these anatomical locations, such as the proximity to the conduction system in parahisian VAs or stability issues when ablating the PMs or MB.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Ablación por Catéter , Estudios de Cohortes , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Músculos Papilares/fisiopatología , Valor Predictivo de las Pruebas , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Resultado del Tratamiento , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/fisiopatología , Complejos Prematuros Ventriculares/terapia
19.
J Cardiovasc Electrophysiol ; 28(5): 504-514, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28233951

RESUMEN

INTRODUCTION: In outflow tract ventricular arrhythmias (OT-VAs), an abrupt loss of the R wave in lead V2 compared to V1 and V3 (pattern break in V2-PBV2) suggests an origin close to the anterior interventricular sulcus (anatomically opposite to lead V2) and adjacent to proximal coronaries. We studied the outcome of catheter ablation of OT-VAs with a PBV2. METHODS AND RESULTS: Of 130 consecutive patients with idiopathic left bundle block morphology OT-VAs and transition ≤V4, 12 (9%) had PBV2. Outcomes in this group were compared to the remaining 118 patients. Patients with PBV2 were more likely to be younger (41 ± 18 vs. 50 ± 14 years, P = 0.0384) and women (11 [92%] vs. 70 [59%], P = 0.0302). The earliest activation was at the RVOT in seven, left coronary cusp (LCC) in one, anterior interventricular vein (AIV) in two and the epicardium in two. In five (42%) cases (earliest activation in the AIV in two, epicardium in two, and RVOT below the valve level in one), ablation was aborted due to proximity to the left anterior descending (LAD) coronary artery. After 36 ± 17 months and 1.3 ± 0.5 procedures, VAs elimination was achieved in 58% of patients with PBV2 compared to 89% of the reference population (P = 0.0125) with effective site in five of seven at the most anterior and leftward RVOT adjacent to the pulmonic valve (PV). CONCLUSIONS: OT-VAs with PBV2 demonstrate a unique ECG pattern and challenging catheter ablation. Proximity to LAD precludes ablation in about half. Long-term VA suppression could be achieved in only 58% of cases most commonly when the earliest site is at the anterior and leftward RVOT just under the PV.


Asunto(s)
Bloqueo de Rama/diagnóstico , Bloqueo de Rama/cirugía , Ablación por Catéter , Electrocardiografía , Ventrículos Cardíacos/cirugía , Potenciales de Acción , Adulto , Bloqueo de Rama/fisiopatología , Ablación por Catéter/efectos adversos , Técnicas Electrofisiológicas Cardíacas , Femenino , Frecuencia Cardíaca , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
20.
Pacing Clin Electrophysiol ; 40(6): 624-628, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28294359

RESUMEN

BACKGROUND: Medical technology has made significant advances over the last few decades with smaller and more dynamic pacemakers. However, technical failures leading to premature replacement is a cause of concern. We present a series of Medtronic EnRhythm devices that reached premature elective replacement indicator (ERI). METHODS: The database of Centre of Heart Rhythm Disorders was searched for EnRhythm device implantation from 2006 to 2011. Battery depletion <8.5 years was considered premature considering the projected average longevity to be 8.5-10.5 years. An unexpected premature ERI was defined when it was reached within 3 months of last normal check. Device follow-up was conducted every 3 months after advisory. RESULTS: A total of 88 EnRhythm pacemakers were implanted. Over a median follow-up of 6.2 years (range: 0.3-9.2), 39 (44.3%) EnRhythm devices reached premature ERI. In 11 (28%), ERI was not recognized and patients were being investigated for other causes of unsteadiness or dyspnea prior to device check. Notably, three (7%) patients had premature ERI < 3.5 years. Ten (25.6%) had sudden and unexpected premature ERI. While asynchronous pacing was observed, there were no cases of absence of pacing. CONCLUSIONS: The rate of premature ERI for EnRhythm devices was 44.3%, significantly higher than reported by the manufacturer. Of concern, a sizeable proportion occurred unexpectedly, warranting more frequent reviews and empirical replacement in some patients. With the experience of the EnRhythm, appropriate monitoring strategies are recommended for future advisories.


Asunto(s)
Remoción de Dispositivos/estadística & datos numéricos , Suministros de Energía Eléctrica/estadística & datos numéricos , Análisis de Falla de Equipo/estadística & datos numéricos , Falla de Equipo/estadística & datos numéricos , Seguridad de Equipos/estadística & datos numéricos , Recall de Suministro Médico , Marcapaso Artificial/estadística & datos numéricos , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Seguridad del Paciente/estadística & datos numéricos , Australia del Sur/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA