Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Exp Allergy ; 52(2): 265-275, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34962661

RESUMEN

BACKGROUND: To determine the proportion and reproducibility of cat-allergic mild asthmatics with early asthmatic response (EAR) during cat allergen exposure in a naturalistic exposure chamber (NEC). METHODS: This was a prospective, observational study in 30 cat-allergic mild asthmatics who received two 180-min cat-allergen (Felis domesticus allergen 1 [Fel d 1]) challenges 27 days apart in an NEC. RESULTS: An EAR (≥20% reduction from baseline in forced expiratory volume in 1 s [FEV1]) was observed in 67% and 52% of subjects at first and second NEC exposure, respectively, with similar median time to EAR; 44% of subjects had an EAR on days 1 and 28. Late asthmatic response (≥15% reduction in FEV1 within 24 h of NEC exit) was observed in 33% of subjects following either exposure. Average FEV1 and total nasal symptom score during NEC exposure were highly correlated within subjects between NEC exposures (r = 0.91, p < 0.0001; r = 0.73, p < 0.001), but total ocular symptom score was not. Time to EAR, but not average FEV1, was significantly associated with NEC Fel d 1 concentration, which was variable. There were no serious adverse events; 12/30 subjects experienced 20 adverse events (including asthma, 10%; headache, 10%). CONCLUSIONS: The NEC model demonstrates that average FEV1 change is highly reproducible and has a low correlation with cat allergen levels. However, time to EAR and incidence of EAR are less reproducible and are highly correlated with NEC allergen levels. Average FEV1, rather than incidence of EAR or time to EAR, could be considered as an endpoint for interventional trials testing cat-specific anti-allergy therapies using an NEC.


Asunto(s)
Asma , Hipersensibilidad , Alérgenos , Pruebas de Provocación Bronquial , Volumen Espiratorio Forzado , Humanos , Hipersensibilidad/complicaciones , Estudios Prospectivos , Reproducibilidad de los Resultados
2.
Patient Saf Surg ; 12: 5, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29560028

RESUMEN

BACKGROUND: Retrieval of inferior vena cava filters (IVCFs) is important to decrease the long-term risk of complications associated with indwelling devices. Our hospital experienced low retrieval rates and implemented a low-cost intervention and evaluation for quality improvement. The working hypothesis was that a simple, mailed letter intervention could increase retrieval rates by increasing patient and primary care provider knowledge of the need for retrieval. METHODS: For all prospective patients who received a retrievable IVCF during the intervention period from January 1, 2014 to February 29, 2016, patients and their primary care providers were mailed letters encouraging contact with the clinic for evaluation of eligibility for retrieval. The main outcome was retrieval of the IVCF if clinically indicated with a secondary outcome of time-to-retrieval. A pre-intervention control group from October 1, 2011 to December 31, 2013 was used to evaluate the impact of the intervention. Competing risks, time-to-event analysis was used to compare the pre- and post-intervention period retrieval rates correcting for patients who died during follow-up. RESULTS: Between the pre- and post-intervention periods, crude retrieval rates increased from 4.4% to 8.1% with a 12-fold change at comparable time points. The time-to-retrieval in the pre-intervention period was a mean (SD) of 503 (207) days with a median (IQR) of 505 (301-742). In the post-intervention period, time-to-retrieval was a mean (SD) of 119 (83) days and with median (IQR) of 128 (38-164) days. CONCLUSIONS: This low-cost intervention significantly increased retrieval rates in a single clinic. However, retrieval rates remain low and can be further improved. Ongoing interventions, including improved patient follow-up and physician education, are being implemented to further improve retrieval and use of inferior vena cava filters. Implanting clinics should implement quality improvement initiatives to improve patient care and follow-up with IVCFs to ensure retrievals occur once clinically relevant in order to minimize long-term complications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA