Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 24(2): e13876, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36560887

RESUMEN

BACKGROUND: The clinical introduction of dedicated treatment units for online adaptive radiation therapy (OART) has led to widespread adoption of daily adaptive radiotherapy. OART allows for rapid generation of treatment plans using daily patient anatomy, potentially leading to reduction of treatment margins and increased normal tissue sparing. However, the OART workflow does not allow for measurement of patient-specific quality assurance (PSQA) during treatment delivery sessions and instead relies on secondary dose calculations for verification of adapted plans. It remains unknown if independent dose verification is a sufficient surrogate for PSQA measurements. PURPOSE: To evaluate the plan quality of previously treated adaptive plans through multiple standard PSQA measurements. METHODS: This IRB-approved retrospective study included sixteen patients previously treated with OART at our institution. PSQA measurements were performed for each patient's scheduled and adaptive plans: five adaptive plans were randomly selected to perform ion chamber measurements and two adaptive plans were randomly selected for ArcCHECK measurements. The same ArcCHECK 3D dose distribution was also sent to Mobius3D to evaluate the second-check dosimetry system. RESULTS: All (n = 96) ion chamber measurements agreed with the planned dose within 3% with a mean of 1.4% (± 0.7%). All (n = 48) plans passed ArcCHECK measurements using a 95% gamma passing threshold and 3%/2 mm criteria with a mean of 99.1% (± 0.7%). All (n = 48) plans passed Mobius3D second-check performed with 95% gamma passing threshold and 5%/3 mm criteria with a mean of 99.0% (± 0.2%). CONCLUSION: Plan measurement for PSQA may not be necessary for every online-adaptive treatment verification. We recommend the establishment of a periodic PSQA check to better understand trends in passing rates for delivered adaptive treatments.


Asunto(s)
Radioterapia de Intensidad Modulada , Humanos , Estudios Retrospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Garantía de la Calidad de Atención de Salud , Radiometría
2.
J Appl Clin Med Phys ; 24(12): e14133, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37643456

RESUMEN

PURPOSE: With the clinical implementation of kV-CBCT-based daily online-adaptive radiotherapy, the ability to monitor, quantify, and correct patient movement during adaptive sessions is paramount. With sessions lasting between 20-45 min, the ability to detect and correct for small movements without restarting the entire session is critical to the adaptive workflow and dosimetric outcome. The purpose of this study was to quantify and evaluate the correlation of observed patient movement with machine logs and a surface imaging (SI) system during adaptive radiation therapy. METHODS: Treatment machine logs and SGRT registration data log files for 1972 individual sessions were exported and analyzed. For each session, the calculated shifts from a pre-delivery position verification CBCT were extracted from the machine logs and compared to the SGRT registration data log files captured during motion monitoring. The SGRT calculated shifts were compared to the reported shifts of the machine logs for comparison for all patients and eight disease site categories. RESULTS: The average (±STD) net displacement of the SGRT shifts were 2.6 ± 3.4 mm, 2.6 ± 3.5 mm, and 3.0 ± 3.2 in the lateral, longitudinal, and vertical directions, respectively. For the treatment machine logs, the average net displacements in the lateral, longitudinal, and vertical directions were 2.7 ± 3.7 mm, 2.6 ± 3.7 mm, and 3.2 ± 3.6 mm. The average difference (Machine-SGRT) was -0.1 ± 1.8 mm, 0.2 ± 2.1 mm, and -0.5 ± 2.5 mm for the lateral, longitudinal, and vertical directions. On average, a movement of 5.8 ± 5.6 mm and 5.3 ± 4.9 mm was calculated prior to delivery for the CBCT and SGRT systems, respectively. The Pearson correlation coefficient between CBCT and SGRT shifts was r = 0.88. The mean and median difference between the treatment machine logs and SGRT log files was less than 1 mm for all sites. CONCLUSION: Surface imaging should be used to monitor and quantify patient movement during adaptive radiotherapy.


Asunto(s)
Radioterapia Guiada por Imagen , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Radioterapia Guiada por Imagen/métodos , Posicionamiento del Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Movimiento , Dosificación Radioterapéutica , Tomografía Computarizada de Haz Cónico/métodos
3.
J Appl Clin Med Phys ; 24(10): e14152, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37703545

RESUMEN

PURPOSE: Knowledge-based planning (KBP) offers the ability to predict dose-volume metrics based on information extracted from previous plans, reducing plan variability and improving plan quality. As clinical integration of KBP is increasing there is a growing need for quantitative evaluation of KBP models. A .NET-based application, RapidCompare, was created for automated plan creation and analysis of Varian RapidPlan models. METHODS: RapidCompare was designed to read calculation parameters and a list of reference plans. The tool copies the reference plan field geometry and structure set, applies the RapidPlan model, optimizes the KBP plan, and generates data for quantitative evaluation of dose-volume metrics. A cohort of 85 patients, divided into training (50), testing (10), and validation (25) groups, was used to demonstrate the utility of RapidCompare. After training and tuning, the KBP model was paired with three different optimization templates to compare various planning strategies in the validation cohort. All templates used the same set of constraints for the planning target volume (PTV). For organs-at-risk, the optimization template provided constraints using the whole dose-volume histogram (DVH), fixed-dose/volume points, or generalized equivalent uniform dose (gEUD). The resulting plans from each optimization approach were compared using DVH metrics. RESULTS: RapidCompare allowed for the automated generation of 75 total plans for comparison with limited manual intervention. In comparing optimization techniques, the Dose/Volume and Lines optimization templates generated plans with similar DVH metrics, with a slight preference for the Lines technique with reductions in heart V30Gy and spinal cord max dose. The gEUD model produced high target heterogeneity. CONCLUSION: Automated evaluation allowed for the exploration of multiple optimization templates in a larger validation cohort than would have been feasible using a manual approach. A final KBP model using line optimization objectives produced the highest quality plans without human intervention.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Órganos en Riesgo , Radioterapia de Intensidad Modulada/métodos , Benchmarking
4.
J Appl Clin Med Phys ; 24(10): e14058, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37289550

RESUMEN

PURPOSE: To commission and assess the clinical performance of a new commercial surface imaging (SI) system by analyzing intra-fraction motion from the initial cohort of patients treated with frameless stereotactic radiosurgery (fSRS). METHODS: The IDENTIFYTM SI system was commissioned for clinical use on an Edge (Varian Medical Systems, Palo Alto, CA) linear accelerator. All patients who received intracranial radiotherapy with HyperArcTM (Varian Medical Systems, Palo Alto, CA) were immobilized with the EncompassTM (Qfix, Avondale, PA) thermoplastic mask and monitored for intra-fraction motion with SI. IDENTIFYTM log files were correlated with trajectory log files to correlate treatment parameters with SI-reported offsets. IDENTIFYTM reported offsets were correlated with gantry and couch angles to assess system performance for obstructed and clear camera field of view. Data were stratified by race to evaluate performance differences due to skin tone. RESULTS: All commissioning data were found to meet recommended tolerances. IDENTIFYTM was used to monitor intra-fraction motion on 1164 fractions from 386 patients. The median magnitude of translational SI reported offsets at the end of treatment was 0.27 mm. SI reported offsets were shown to increase when camera pods are blocked by the gantry with larger increases seen at non-zero couch angles. With camera obstruction, the median magnitude of the SI reported offset was 0.50 and 0.80 mm for White and Black patients, respectively. CONCLUSIONS: IDENTIFYTM performance during fSRS is comparable to other commercially available SI systems where offsets are shown to increase at non-zero couch angles and during camera pod blockage.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Radiocirugia/métodos , Posicionamiento del Paciente/métodos , Aceleradores de Partículas , Fantasmas de Imagen , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Neoplasias Encefálicas/radioterapia
5.
J Appl Clin Med Phys ; 24(7): e13961, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36920871

RESUMEN

PURPOSE: Online Adaptive Radiation Therapy (oART) follows a different treatment paradigm than conventional radiotherapy, and because of this, the resources, implementation, and workflows needed are unique. The purpose of this report is to outline our institution's experience establishing, organizing, and implementing an oART program using the Ethos therapy system. METHODS: We include resources used, operational models utilized, program creation timelines, and our institutional experiences with the implementation and operation of an oART program. Additionally, we provide a detailed summary of our first year's clinical experience where we delivered over 1000 daily adaptive fractions. For all treatments, the different stages of online adaption, primary patient set-up, initial kV-CBCT acquisition, contouring review and edit of influencer structures, target review and edits, plan evaluation and selection, Mobius3D 2nd check and adaptive QA, 2nd kV-CBCT for positional verification, treatment delivery, and patient leaving the room, were analyzed. RESULTS: We retrospectively analyzed data from 97 patients treated from August 2021-August 2022. One thousand six hundred seventy seven individual fractions were treated and analyzed, 632(38%) were non-adaptive and 1045(62%) were adaptive. Seventy four of the 97 patients (76%) were treated with standard fractionation and 23 (24%) received stereotactic treatments. For the adaptive treatments, the generated adaptive plan was selected in 92% of treatments. On average(±std), adaptive sessions took 34.52 ± 11.42 min from start to finish. The entire adaptive process (from start of contour generation to verification CBCT), performed by the physicist (and physician on select days), was 19.84 ± 8.21 min. CONCLUSION: We present our institution's experience commissioning an oART program using the Ethos therapy system. It took us 12 months from project inception to the treatment of our first patient and 12 months to treat 1000 adaptive fractions. Retrospective analysis of delivered fractions showed that the average overall treatment time was approximately 35 min and the average time for the adaptive component of treatment was approximately 20 min.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Estudios Retrospectivos , Fraccionamiento de la Dosis de Radiación , Dosificación Radioterapéutica
6.
J Appl Clin Med Phys ; 23(8): e13697, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35819973

RESUMEN

PURPOSE: To validate surface imaging (SI)-reported offsets using a six degree-of-freedom couch and an anthropomorphic phantom for commissioning and routine quality assurance of an SI system used for stereotactic radiosurgery (SRS). METHODS: An anthropomorphic phantom with a radiopaque ball bearing (BB) placed either anterior, midline, or posterior, was tracked with SI with a typical SRS region of interest. Couch motion in all six degrees of freedom was programmed and delivered on a linac. SI system logs were synchronized with linac trajectory logs. Ten random couch positions were selected at couch 0°, 45°, 90°, 270°, 315° with megavolt (MV) images taken to account for couch walkout. The SI residual error (ε), the difference between SI reported offset and MV or trajectory log position, was calculated. Residual errors were measured with and without one SI pod blocked. RESULTS: The median [range] of magnitude of translational ε was 0.13 [0.07, 0.21], 0.16 [0.11, 0.26], 0.61 [0.50, 0.68], 0.49 [0.42, 0.55], 0.55 [0.38, 0.72] mm for couch rotations of 0°, 45°, 90°, 270°, 315°, respectively, for the midline BB and no pod blocked. The range of all translational ε from all couch angles (with and without pod block) at different BB positions is [0.05, 0.96] mm. The absolute range of difference when changing BB position when no pod is blocked in median translational ε is [0.01, 0.40] mm with the maximum at BB posterior. The absolute range of difference when not changing BB positions with and without pod block in median translational ε is [0.01, 0.37] mm with the maximum at BB posterior and couch 315°. CONCLUSION: SI system and linac trajectory log analysis can be used to assess SI system performance with automated couch motion to validate SI accuracy.


Asunto(s)
Radiocirugia , Humanos , Movimiento (Física) , Aceleradores de Partículas , Fantasmas de Imagen , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos
7.
J Appl Clin Med Phys ; 23(5): e13562, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35157356

RESUMEN

A multileaf collimator (MLC), virtual-cone treatment technique has been commissioned for trigeminal neuralgia (TGN) at Tri-Cities Cancer Center (TCCC). This novel technique was initially developed at the University of Alabama in Birmingham (UAB); it is designed to produce a spherical dose profile similar to a fixed, 5-mm conical collimator distribution. Treatment is delivered with a 10-MV flattening-filter-free (FFF) beam using a high-definition MLC on a Varian Edge linear accelerator. Absolute dose output and profile measurements were performed in a 20 × 20 × 14 cm3 solid-water phantom using an Exradin W2 scintillation detector and Gafchromic EBT3 film. Dose output constancy for the virtual cone was evaluated over 6 months using an Exradin A11 parallel plate chamber. The photo-neutron dose generated by these treatments was assessed at distances of 50 and 100 cm from isocenter using a Ludlum Model 30-7 Series Neutron Meter. TGN treatments at TCCC have been previously delivered at 6-MV FFF using a 5-mm stereotactic cone. To assess the dosimetric impact of using a virtual cone, eight patients previously treated for TGN with a 5-mm cone were re-planned using a virtual cone. Seven patients have now been treated for TGN using a virtual cone at TCCC. Patient-specific quality assurance was performed for each patient using Gafchromic EBT-XD film inside a Standard Imaging Stereotactic Dose Verification Phantom. The commissioning results demonstrate that the virtual-cone dosimetry, first described at UAB, is reproducible on a second Edge linear accelerator at an independent clinical site. The virtual cone is a credible alternative to a physical, stereotactic cone for the treatment of TGN at TCCC.


Asunto(s)
Radiocirugia , Neuralgia del Trigémino , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Radiometría , Radiocirugia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Neuralgia del Trigémino/radioterapia , Neuralgia del Trigémino/cirugía
8.
J Appl Clin Med Phys ; 22(8): 273-279, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34247454

RESUMEN

PURPOSE: The task of software development has become an increasing part of the medical physicist's role. Many physicists who are untrained in the best practices of software development have begun creating scripts for clinical use. There is an increasing need for guidance for both developers and medical physicists to code wisely in the clinic. MATERIALS AND METHODS: We created a novel model for assessing risk for custom clinical software analogous to failure modes and effects analysis and propose minimum best practices that should be followed to mitigate the risks. Using this risk model, we integrated a literature review and institutional experience to form a practical guide for risk mitigation. RESULTS: Using this new risk assessment model, we outlined several risk mitigation techniques including unit testing, code review, source control, end-user testing, and commissioning from the literature while sharing our institutional guidelines for evaluating software for risk and implementing these strategies. CONCLUSION: We found very little literature for custom software development guidelines targeted at medical physicists. We have shared our institutional experience and guidelines to help facilitate safe software development for the evolving role of the medical physicist.


Asunto(s)
Programas Informáticos , Humanos , Medición de Riesgo
9.
J Appl Clin Med Phys ; 22(12): 203-210, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34725909

RESUMEN

PURPOSE: To evaluate a two-dimensional diode array for patient-specific quality assurance of VMAT stereotactic radiosurgery (SRS) plans. METHODS: The diode array, an SRS MapCHECK (SRSMC), was composed of a 77 mm ×77 mm face-centered array having a spacing of 2.47 mm. Sixty SRS plans were selected from our clinical database, 30 for treatment of a single target and 30 for multiple targets. The target sizes ranged from 2.4 mm to 44.7 mm equivalent diameter (median 8.7 mm). The plans were delivered to the diode array. For multiple target plans, two measurements were obtained at two locations, one corresponding to the largest target and the other to the smallest target. Gamma using a 3%/1 mm criteria and the dose to the center diode were compared with radiochromic film (RCF). Dose to selected regions of the detector electronics was calculated. RESULTS: The mean difference between the center diode and RCF was -1.2%. For a threshold of at least 95% of detectors/pixels having gamma < 1 for a 3%/1 mm criteria, SRSMC and RCF gave consistent results for 79 of the 90 measurements. For plans with an arc having a patient support angle of 90° or 270°, the median dose to the electronics was 0.65% of the prescription dose. CONCLUSIONS: SRSMC is an efficient tool for accurate patient-specific quality assurance of VMAT single and multiple target radiosurgery, yielding similar clinical decisions as radiochromic film.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
10.
J Appl Clin Med Phys ; 21(3): 192-195, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32039543

RESUMEN

PURPOSE: To create automated tools within the treatment planning system (TPS) that eliminate the common error pathway of providing incorrect shift instructions to therapists. MATERIALS/METHODS: Two scripts were created within the TPS using the Eclipse API (Varian Medical Systems, Palo Alto, CA). One script detects whether or not the user origin has been placed correctly at the intersection of the simulation markers while the other calculates a shift instruction sheet that can be printed for treatment. RESULTS: Analysis of our RO-ILS database identified eight errors caused by improper setting of the user origin in the treatment planning system. The user origin script flagged all of the treatment plans for markers inconsistent with user origin. Automated calculation of shifts eliminated the error pathway of miscalculating or transcribing shift values. CONCLUSION: Automation can eliminate the common error pathway of providing the wrong shifts to therapists. The scripts have been made available as open-source software for implementation at other radiotherapy clinics.


Asunto(s)
Neoplasias/radioterapia , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Programas Informáticos , Automatización , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos
11.
J Appl Clin Med Phys ; 21(12): 90-95, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33095971

RESUMEN

PURPOSE: To report on the use of surface guided imaging during frameless intracranial stereotactic radiotherapy with automated delivery via HyperArcTM (Varian Medical Systems, Palo Alto, CA). METHODS: All patients received intracranial radiotherapy with HyperArcTM and were monitored for intrafraction motion by the AlignRT® (VisionRT, London, UK) surface imaging (SI) system. Immobilization was with the EncompassTM (Qfix, Avondale, PA) aquaplast mask device. AlignRT® log files were correlated with trajectory log files to correlate treatment parameters with SI reported offsets. SI reported offsets were correlated with gantry angle and analyzed for performance issues at non-zero couch angles and during camera-pod blockage during gantry motion. Demographics in the treatment management system were used to identify race and determine if differences in SI reported offsets are due to skin tone settings. RESULTS: A total of 981 fractions were monitored over 14 months and 819 were analyzed. The median AlignRT® reported motion from beginning to the end of treatment was 0.24 mm. The median offset before beam on at non-zero couch angles was 0.55 mm. During gantry motion when camera pods are blocked, the median magnitude was below 1 mm. Median magnitude of offsets at non-zero couch angles was not found to be significantly different for patients stratified by race. CONCLUSIONS: Surface image guidance is a viable alternative to scheduled mid-treatment imaging for monitoring intrafraction motion during stereotactic radiosurgery with automated delivery.


Asunto(s)
Radiocirugia , Tomografía Computarizada de Haz Cónico , Humanos , Inmovilización , Movimiento (Física) , Posicionamiento del Paciente , Planificación de la Radioterapia Asistida por Computador
12.
Acta Oncol ; 58(9): 1275-1282, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31257960

RESUMEN

Introduction: Stereotactic radiosurgery (SRS) is a promising treatment option for patients with multiple brain metastases (BM). Recent technical advances have made LINAC based SRS a patient friendly technique, allowing for accurate patient positioning and a short treatment time. Since SRS is increasingly being used for patients with multiple BM, it remains essential that SRS be performed with the highest achievable quality in order to prevent unnecessary complications such as radionecrosis. The purpose of this article is to provide guidance for high-quality LINAC based SRS for patients with BM, with a focus on single isocenter non-coplanar volumetric modulated arc therapy (VMAT). Methods: The article is based on a consensus statement by the study coordinators and medical physicists of four trials which investigated whether patients with multiple BM are better palliated with SRS instead of whole brain radiotherapy (WBRT): A European trial (NCT02353000), two American trials and a Canadian CCTG lead intergroup trial (CE.7). This manuscript summarizes the quality assurance measures concerning imaging, planning and delivery. Results: To optimize the treatment, the interval between the planning-MRI (gadolinium contrast-enhanced, maximum slice thickness of 1.5 mm) and treatment should be kept as short as possible (< two weeks). The BM are contoured based on the planning-MRI, fused with the planning-CT. GTV-PTV margins are minimized or even avoided when possible. To maximize efficiency, the preferable technique is single isocenter (non-)coplanar VMAT, which delivers high doses to the target with maximal sparing of the organs at risk. The use of flattening filter free photon beams ensures a lower peripheral dose and shortens the treatment time. To bench mark SRS treatment plan quality, it is advisable to compare treatment plans between hospitals. Conclusion: This paper provides guidance for quality assurance and optimization of treatment delivery for LINAC-based radiosurgery for patients with multiple BM.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundario , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Encefálicas/diagnóstico por imagen , Ensayos Clínicos como Asunto , Consenso , Medios de Contraste , Gadolinio , Humanos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal , Posicionamiento del Paciente , Selección de Paciente , Garantía de la Calidad de Atención de Salud , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia de Intensidad Modulada/normas , Tomografía Computarizada por Rayos X
13.
J Appl Clin Med Phys ; 20(9): 163-165, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31536666

RESUMEN

PURPOSE: Compliance with TG-263 nomenclature standards can be challenging. We introduce an open source solution to this problem and evaluate its impact on compliance within our institution. MATERIALS/METHODS: The TG-236 nomenclature standards were implemented in our clinic in two phases. In phase 1, we deployed TG-263 compliant templates for each disease site. In phase 2, we developed and deployed a script for evaluating compliance which presented errors to the user. After each phase the compliance was recorded. RESULTS: Mean compliance errors prior to phase 1 was 31.8% ± 17.4%. Error rates dropped to 8.1% ± 12.2% across phase 1 and dropped further to 2.2% ± 6.9% during the automation system deployed in phase 2. CONCLUSION: Both structure templates and automation scripts are very useful for increasing compliance with structure naming standards. Our software solution is made available on GitHub for other institutions to implement.


Asunto(s)
Neoplasias/clasificación , Neoplasias/radioterapia , Garantía de la Calidad de Atención de Salud/normas , Oncología por Radiación , Planificación de la Radioterapia Asistida por Computador/normas , Terminología como Asunto , Humanos , Dosificación Radioterapéutica
14.
J Appl Clin Med Phys ; 20(9): 143-148, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31538717

RESUMEN

PURPOSE: To evaluate a scintillator detector for patient-specific quality assurance of VMAT radiosurgery plans. METHODS: The detector was comprised of a 1 mm diameter, 1 mm high scintillator coupled to an acrylic optical fiber. Sixty VMAT SRS plans for treatment of single targets having sizes ranging from 3 mm to 30.2 mm equivalent diameter (median 16.3 mm) were selected. The plans were delivered to a 20 cm × 20 cm x 15 cm water equivalent plastic phantom having either the scintillator detector or radiochromic film at the center. Calibration films were obtained for each measurement session. The films were scanned and converted to dose using a 3-channel technique. RESULTS: The mean difference between scintillator and film was -0.45% (95% confidence interval -0.1% to 0.8%). For target equivalent diameter smaller than the median, the mean difference was 1.1% (95% confidence interval 0.5% to 1.7%). For targets larger than the median, the mean difference was -0.2% (95% confidence interval -0.7% to 0.1%). CONCLUSIONS: The scintillator detector response is independent of target size for targets as small as 3 mm and is well-suited for patient-specific quality assurance of VMAT SRS plans. Further work is needed to evaluate the accuracy for VMAT plans that treat multiple targets using a single isocenter.


Asunto(s)
Fantasmas de Imagen , Plásticos , Garantía de la Calidad de Atención de Salud/normas , Radiocirugia/instrumentación , Radiocirugia/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Conteo por Cintilación/instrumentación , Calibración , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica
15.
J Appl Clin Med Phys ; 20(5): 135-140, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30933414

RESUMEN

PURPOSE: To assess the feasibility of using portal dosimetry (PD) for pre-treatment quality assurance of single target, flattening filter free (FFF), volumetric arc therapy intracranial radiosurgery plans. METHODS: A PD algorithm was created for a 10X FFF beam on a Varian Edge linear accelerator (Varian Inc, Palo Alto, CA, USA). Treatment plans that were previously evaluated with Gafchromic EBT-XD (Ashland, Bridgewater, NJ, USA) film were measured via PD and analyzed with the ARIA Portal Dosimetry workspace. Absolute dose evaluation for film and PD was done by computing the mean dose in the region receiving greater than or equal to 90% of the max dose and comparing to the mean dose in the same region calculated by the treatment planning system (TPS). Gamma analysis with 10% threshold and 3%/2 mm passing criteria was performed on film and portal images. RESULTS: Thirty-six PD verification plans were delivered and analyzed. The average PD to TPS dose was 0.989 ± 0.01 while film to TPS dose was 1.026 ± 0.01. All PD plans passed the gamma analysis with 100% of points having gamma <1. Overall, PD to TPS dose agreement was found to be target size dependent. As target size decreases, PD to TPS dose ratio decreased from 1.004 for targets with diameters between 15-31 mm and 0.978 for targets with diameters less than 15 mm. CONCLUSION: The agreement of PD to TPS mean dose in the high dose region was found to be dependent on target size. Film measurements did not exhibit size dependence. All PD plans passed the 3%/2 mm gamma analysis, but caution should be used when using PD to assess overall dosimetric accuracy of the treatment plan for small targets.


Asunto(s)
Algoritmos , Neoplasias/cirugía , Aceleradores de Partículas/instrumentación , Garantía de la Calidad de Atención de Salud/normas , Radiometría/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios de Factibilidad , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
16.
J Appl Clin Med Phys ; 20(5): 84-98, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30977297

RESUMEN

PURPOSE: To measure dosimetric and spatial accuracy of stereotactic radiosurgery (SRS) delivered to targets as small as the trigeminal nerve (TN) using a standard external beam treatment planning system (TPS) and multileaf collimator-(MLC) equipped linear accelerator without cones or other special attachments or modifications. METHODS: Dosimetric performance was assessed by comparing computed dose distributions to film measurements. Comparisons included the γ-index, beam profiles, isodose lines, maximum dose, and spatial accuracy. Initially, single static 360° arcs of MLC-shaped fields ranging from 1.6 × 5 to 30 × 30 mm2 were planned and delivered to an in-house built block phantom having approximate dimensions of a human head. The phantom was equipped with markings that allowed accurate setup using planar kV images. Couch walkout during multiple-arc treatments was investigated by tracking a ball pointer, initially positioned at cone beam computed tomography (CBCT) isocenter, as the couch was rotated. Tracks were mapped with no load and a 90 kg stack of plastic plates simulating patient treatment. The dosimetric effect of walkout was assessed computationally by comparing test plans that corrected for walkout to plans that neglected walkout. The plans involved nine 160° arcs of 2.4 × 5 mm2 fields applied at six different couch angles. For end-to-end tests that included CT simulation, target contouring, planning, and delivery, a cylindrical phantom mimicking a 3 mm lesion was constructed and irradiated with the nine-arc regimen. The phantom, lacking markings as setup aids was positioned under CBCT guidance by registering its surface and internal structures with CTs from simulation. Radiochromic film passing through the target center was inserted parallel to the coronal and the sagittal plane for assessment of spatial and dosimetric accuracy. RESULTS: In the single-arc block phantom tests computed maximum doses of all field sizes agreed with measurements within 2.4 ± 2.0%. Profile widths at 50% maximum agreed within 0.2 mm. The largest targeting error was 0.33 mm. The γ-index (3%, 1 mm) averaged over 10 experiments was >1 in only 1% of pixels for field sizes up to 10 × 10 mm2 and rose to 4.4% as field size increased to 20 × 20 mm2 . Table walkout was not affected by load. Walkout shifted the target up to 0.6 mm from CBCT isocenter but, according to computations shifted the dose cloud of the nine-arc plan by only 0.16 mm. Film measurements verified the small dosimetric effect of walkout, allowing walkout to be neglected during planning and treatment. In the end-to-end tests average and maximum targeting errors were 0.30 ± 0.10 and 0.43 mm, respectively. Gamma analysis of coronal and sagittal dose distributions based on a 3%/0.3 mm agreement remained <1 at all pixels. To date, more than 50 functional SRS treatments using MLC-shaped static field arcs have been delivered. CONCLUSION: Stereotactic radiosurgery (SRS) can be planned and delivered on a standard linac without cones or other modifications with better than 0.5 mm spatial and 5% dosimetric accuracy.


Asunto(s)
Malformaciones Arteriovenosas/cirugía , Neoplasias Encefálicas/cirugía , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
17.
J Appl Clin Med Phys ; 20(6): 91-98, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-31095866

RESUMEN

PURPOSE: To evaluate the accuracy of monitoring intrafraction motion during stereotactic radiotherapy with the optical surface monitoring system. Prior studies showing a false increase in the magnitude of translational offsets at non-coplanar couch positions prompted the vendor to implement software changes. This study evaluated two software improvements intended to address false offsets. METHODS: The vendor implemented two software improvements: a volumetric (ACO) rather than planar calibration and, approximately 6 months later, an improved calibration workflow (CIB) designed to better compensate for thermal drift. Offsets relative to the reference position, obtained at table angle 0 following image-guided setup, were recorded before beam-on at each table position and at the end of treatment the table returned to 0° for patients receiving SRT. RESULTS: Prior to ACO, between ACO and CIB, and after CIB, 223, 155, and 436 fractions were observed respectively. The median magnitude of translational offsets at the end of treatment was similar for all three intervals: 0.29, 0.33, and 0.27 mm. Prior to ACO, the offset magnitude for non-zero table positions had a median of 0.79 mm and was found to increase with increasing distance from isocenter to the anterior patient surface. After ACO, the median magnitude was 0.74 mm, but the dependence on surface-to-isocenter distance was eliminated. After CIB, the median magnitude for non-zero table positions was reduced to 0.57 mm. CONCLUSION: Ongoing improvements in software and calibration procedures have decreased reporting of false offsets at non-zero table angles. However, the median magnitude for non-zero table angles is larger than that observed at the end of treatment, indicating that accuracy remains better when the table is not rotated.


Asunto(s)
Neoplasias Encefálicas/cirugía , Posicionamiento del Paciente , Fantasmas de Imagen , Radiocirugia/instrumentación , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Cirugía Asistida por Computador/instrumentación , Neoplasias Encefálicas/patología , Humanos , Inmovilización , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Programas Informáticos
18.
J Appl Clin Med Phys ; 20(1): 17-22, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30387242

RESUMEN

PURPOSE: To assess the long-term stability of the anchored radiofrequency transponders and compare displacement rates with other commercially available lung fiducial markers. We also sought to describe late toxicity attributable to fiducial implantation or migration. MATERIALS AND METHODS: The transponder cohort was comprised of 17 patients at our institution who enrolled in a multisite prospective clinical trial and underwent bronchoscopic implantation of three anchored transponders into small (2-2.5 mm) airways. We generated a comparison cohort of 34 patients by selecting patients from our institutional lung SBRT database and matching 2:1 based on the lobe containing tumor and proximity to the bronchial tree. Assessment of migration was performed by rigidly registering the most recent follow-up CT scan to the simulation scan, and assessing whether the relative geometry of the fiducial markers had changed by more than 5 mm. Toxicity outcomes of interest were hemoptysis and pneumothorax. RESULTS: The median follow-up of patients in the transponder cohort was 25.3 months and the median follow-up in the comparison cohort was 21.7 months. When assessing the most recent CT, all fiducial markers were within 5 mm of their position at CT simulation in 11 (65%) patients in the transponder group as compared to 23 (68%) in the comparison group (P = 0.28). One case of hemoptysis was identified in the transponder cohort, and bronchoscopy confirmed bleeding from recurrent tumor; no cases of hemoptysis were noted in the comparison cohort. No case of pneumothorax was noted in either group. CONCLUSION: No significant difference in the rates of fiducial marker retention and migration were noted when comparing patients who had anchored transponders placed into small airways and a 2:1 matched cohort of patients who had other commercially available lung fiducial markers placed. In both groups, no late or chronic toxicity appeared to be related to the implanted fiducial markers.


Asunto(s)
Fenómenos Electromagnéticos , Neoplasias Pulmonares/cirugía , Prótesis e Implantes , Radiocirugia , Planificación de la Radioterapia Asistida por Computador/métodos , Terapia Asistida por Computador/instrumentación , Marcadores Fiduciales , Humanos , Estudios Longitudinales , Pronóstico , Estudios Prospectivos , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
19.
J Appl Clin Med Phys ; 17(3): 52-60, 2016 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-27167259

RESUMEN

The purpose of this study was to evaluate the accuracy and calculation speed of electron dose distributions calculated by the Eclipse electron Monte Carlo (eMC) algorithm for use with bolus electron conformal therapy (ECT). The recent com-mercial availability of bolus ECT technology requires further validation of the eMC dose calculation algorithm. eMC-calculated electron dose distributions for bolus ECT have been compared to previously measured TLD-dose points throughout patient-based cylindrical phantoms (retromolar trigone and nose), whose axial cross sections were based on the mid-PTV (planning treatment volume) CT anatomy. The phantoms consisted of SR4 muscle substitute, SR4 bone substitute, and air. The treatment plans were imported into the Eclipse treatment planning system, and electron dose distributions calculated using 1% and < 0.2% statistical uncertainties. The accuracy of the dose calculations using moderate smoothing and no smooth-ing were evaluated. Dose differences (eMC-calculated less measured dose) were evaluated in terms of absolute dose difference, where 100% equals the given dose, as well as distance to agreement (DTA). Dose calculations were also evaluated for calculation speed. Results from the eMC for the retromolar trigone phantom using 1% statistical uncertainty without smoothing showed calculated dose at 89% (41/46) of the measured TLD-dose points was within 3% dose difference or 3 mm DTA of the measured value. The average dose difference was -0.21%, and the net standard deviation was 2.32%. Differences as large as 3.7% occurred immediately distal to the mandible bone. Results for the nose phantom, using 1% statistical uncertainty without smoothing, showed calculated dose at 93% (53/57) of the measured TLD-dose points within 3% dose difference or 3 mm DTA. The average dose difference was 1.08%, and the net standard deviation was 3.17%. Differences as large as 10% occurred lateral to the nasal air cavities. Including smoothing had insignificant effects on the accuracy of the retromolar trigone phantom calculations, but reduced the accuracy of the nose phantom calculations in the high-gradient dose areas. Dose calculation times with 1% statistical uncertainty for the retromolar trigone and nose treatment plans were 30 s and 24 s, respectively, using 16 processors (Intel Xeon E5-2690, 2.9 GHz) on a framework agent server (FAS). In comparison, the eMC was significantly more accurate than the pencil beam algorithm (PBA). The eMC has comparable accuracy to the pencil beam redefinition algorithm (PBRA) used for bolus ECT planning and has acceptably low dose calculation times. The eMC accuracy decreased when smoothing was used in high-gradient dose regions. The eMC accuracy was consistent with that previously reported for accuracy of the eMC electron dose algorithm and shows that the algorithm is suitable for clinical implementation of bolus ECT.


Asunto(s)
Algoritmos , Electrones , Método de Montecarlo , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/normas , Radioterapia Conformacional/normas , Humanos , Dosificación Radioterapéutica
20.
J Appl Clin Med Phys ; 17(4): 246-253, 2016 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-27455506

RESUMEN

Stereotactic radiosurgery (SRS) places great demands on spatial accuracy. Steel BBs used as markers in quality assurance (QA) phantoms are clearly visible in MV and planar kV images, but artifacts compromise cone-beam CT (CBCT) isocenter localization. The purpose of this work was to develop a QA phantom for measuring with sub-mm accuracy isocenter congruence of planar kV, MV, and CBCT imaging systems and to design a practical QA procedure that includes daily Winston-Lutz (WL) tests and does not require computer aid. The salient feature of the phantom (Universal Alignment Ball (UAB)) is a novel marker for precisely localizing isocenters of CBCT, planar kV, and MV beams. It consists of a 25.4mm diameter sphere of polymethylmetacrylate (PMMA) containing a concentric 6.35mm diameter tungsten carbide ball. The large density difference between PMMA and the polystyrene foam in which the PMMA sphere is embedded yields a sharp image of the sphere for accurate CBCT registration. The tungsten carbide ball serves in finding isocenter in planar kV and MV images and in doing WL tests. With the aid of the UAB, CBCT isocenter was located within 0.10 ± 0.05 mm of its true positon, and MV isocenter was pinpointed in planar images to within 0.06 ± 0.04mm. In clinical morning QA tests extending over an 18 months period the UAB consistently yielded measurements with sub-mm accuracy. The average distance between isocenter defined by orthogonal kV images and CBCT measured 0.16 ± 0.12 mm. In WL tests the central ray of anterior beams defined by a 1.5 × 1.5 cm2 MLC field agreed with CBCT isocenter within 0.03 ± 0.14 mm in the lateral direction and within 0.10 ± 0.19 mm in the longitudinal direction. Lateral MV beams approached CBCT isocenter within 0.00 ± 0.11 mm in the vertical direction and within -0.14 ± 0.15 mm longitudinally. It took therapists about 10 min to do the tests. The novel QA phantom allows pinpointing CBCT and MV isocenter positions to better than 0.2 mm, using visual image registration. Under CBCT guidance, MLC-defined beams are deliverable with sub-mm spatial accuracy. The QA procedure is practical for daily tests by therapists.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Aceleradores de Partículas/instrumentación , Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/métodos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/normas , Humanos , Posicionamiento del Paciente , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA