Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Klin Padiatr ; 236(2): 97-105, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38224687

RESUMEN

Relapsing polychondritis (RP) is a rare immune-mediated disease that primarily affects the cartilaginous structures of the ears, nose and airways. The clinical spectrum ranges from mild to severe disease characterized by progressive destruction of cartilage in the tracheobronchial tree leading to airway obstruction and acute respiratory failure. Early diagnosis is crucial to prevent irreversible airway damage and life-threatening complications. Due to its rarity and variability of symptoms, the diagnosis of RP is often delayed particularly in childhood. To address this and increase awareness of this rare disease, we present a detailed case report of two adolescent females affected by RP. We aim to describe the clinical findings, consequences of a delayed diagnosis and provide a review of the current literature.


Asunto(s)
Policondritis Recurrente , Adolescente , Femenino , Humanos , Policondritis Recurrente/complicaciones , Policondritis Recurrente/diagnóstico
2.
Clin Otolaryngol ; 45(4): 495-499, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32246580

RESUMEN

OBJECTIVES: To determine the levels of endogenous α1-antitrypsin in the perilymph of patients undergoing cochlear implant (CI), and its reverse association with the severity of hearing loss. STUDY DESIGN: Retrospective study. SETTING: Tertiary care university hospital. PARTICIPANTS: The study includes 38 patients undergoing CI surgery, 11 patients diagnosed with congenital deafness and 27 non-congenital deafness, eight patients diagnosed with moderate hearing loss (N = 8; PTA = 70 dB), severe hearing loss (N = 11; PTA 70-90 dB) and profound hearing loss (N = 19; PTA > 90 dB). MAIN OUTCOME AND MEASURE: 1 to 12 µL perilymphatic fluids were collected by micropipette. α1-antitrypsin levels were determined, and current and historic audiological parameters were obtained. RESULTS: The congenital and non-congenital group exhibited AAT concentrations of 2.5 ± 1.9 × 106 LFQ and 3.2 ± 1.2 × 106 LFQ, respectively (mean ± SD; P = .38). Mean levels of α1-antitrypsin in the perilymph fluid within the moderate group was 3.64 × 106  ± 2.1 × 106 LFQ vs 3.5 × 106  ± 1.2 × 106 in severe hearing loss (P = .81) and 2.4 × 106  ± 1.1 × 106 LFQ in the profound hearings loss group (P = .06). The difference in levels of AAT in samples from the severe hearings loss group vs the profound hearings loss group reached statistical significance (P = .04). CONCLUSION: Insufficiency in α1-antitrypsin levels in the perilymph fluid of the inner ear appears to display a relationship with the severity of hearing loss. The prospect of introducing clinical-grade plasma-purified α1-antitrypsin directly onto the site of cochlear injury deserves thorough investigation.


Asunto(s)
Pérdida Auditiva/cirugía , Fragmentos de Péptidos/metabolismo , Perilinfa/química , alfa 1-Antitripsina/metabolismo , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Pérdida Auditiva/congénito , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
3.
Artículo en Inglés | MEDLINE | ID: mdl-29902786

RESUMEN

OBJECTIVE: To evaluate possible increases in bone conduction (BC) hearing thresholds in patients undergoing subtotal petrosectomy (SP) with fat obliteration and blind sac closure of the outer ear canal and subsequent round window vibroplasty. PATIENTS AND INTERVENTIONS: Between 1997 and 2013, 43 patients (45 ears) with combined hearing loss and recurrent chronic otitis or status post formation of a radical cavity underwent SP around 6 months prior to implantation of a Vibrant SoundbridgeTM. Pure tone audiograms (0.5, 1, 1.5, 2, 3, 4, and 6 kHz) prior to SP, after SP, prior to implantation, after implantation, and at first fitting around 5 weeks after implantation were collected and statistically analyzed. RESULTS: The comparison between BC thresholds before SP and at first fitting showed an overall decline during the two-step procedure between 2.8 and 6 dB that was significant (p < 0.05, Student t test) at 2, 3, 4, and 6 kHz. CONCLUSION: In some cases, SP is the only way to eradicate chronic otitis and to achieve a suitable environment for the implantation of active middle ear implants. The present data demonstrate a relatively small but significant decline in BC thresholds throughout the whole procedure. Knowledge of its extent is mandatory for a correct indication for later implantation of a Vibrant SoundbridgeTM.


Asunto(s)
Conducción Ósea , Perdida Auditiva Conductiva-Sensorineural Mixta/cirugía , Prótesis Osicular , Reemplazo Osicular/métodos , Hueso Petroso/cirugía , Ventana Redonda/cirugía , Audiometría , Audífonos , Perdida Auditiva Conductiva-Sensorineural Mixta/rehabilitación , Humanos , Persona de Mediana Edad
4.
Eur Arch Otorhinolaryngol ; 274(2): 751-756, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27783138

RESUMEN

The exact pathomechanism of deafening in Meniere's disease (MD) is still unknown; intoxication of hair cells and neural damage from endolymphatic hydrops is discussed. In the literature, there are only a few reports on hearing outcome of MD patients after treatment with cochlear implantation (CI) whereby especially the comparison of MD vs. non-MD patients with CI differs. In this retrospective study, results in speech understanding [Freiburger Einsilber (FES65) and Hochmair-Schulz-Moser test in quiet (HSM) and in noise (HSM + 10 dB)] of 27 implanted MD patients were collected and compared to a matched standard CI cohort. Alternative diagnoses were excluded as far as possible by re-analyzing neuroradiologic imaging. After first fitting, MD patients showed significantly better results in FES and HSM testing compared to controls. At 1-year refitting, this effect could not be seen anymore. To conclude, cochlear implantation is a safe and effective treatment for deafness in MD patients. Results in speech understanding are at least equal compared to general CI recipients. To the best of our knowledge, this retrospective study examined the largest collective of CI users deafened by MD so far.


Asunto(s)
Implantes Cocleares , Sordera/cirugía , Enfermedad de Meniere/complicaciones , Audiometría de Tonos Puros , Estudios de Casos y Controles , Implantación Coclear , Sordera/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Percepción del Habla , Hueso Temporal/diagnóstico por imagen
5.
J Mater Sci Mater Med ; 26(1): 5334, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25577215

RESUMEN

Chronic inflammation can irreversibly damage components of the ossicular chain which may lead to sound conduction deafness. The replacement of impaired ossicles with prostheses does not reduce the risk of bacterial infections which may lead to loss of function of the implant and consequently to additional damage of the connected structures such as inner ear, meninges and brain. Therefore, implants that could do both, reconstruct the sound conduction and in addition provide antibacterial protection are of high interest for ear surgery. Layered double hydroxides (LDHs) are promising novel biomaterials that have previously been used as an antibiotic-releasing implant coating to curb bacterial infections in the middle ear. However, animal studies of LDHs are scarce and there exist only few additional data on the biocompatibility and hardly any on the biodegradation of these compounds. In this study, middle ear prostheses were coated with an LDH compound, using suspensions of nanoparticles of an LDH containing Mg and Al as well as carbonate ions. These coatings were characterized and implanted into the middle ear of healthy rabbits for 10 days. Analysis of the explanted prostheses showed only little signs of degradation. A stable health constitution was observed throughout the whole experiment in every animal. The results show that LDH-based implant coatings are biocompatible and dissolve only slowly in the middle ear. They, therefore, appear as promising materials for the construction of controlled drug delivery vehicles.


Asunto(s)
Materiales Biocompatibles , Materiales Biocompatibles Revestidos/química , Oído Medio/patología , Hidróxidos/química , Prótesis e Implantes , Animales , Masculino , Microscopía Electrónica de Rastreo , Conejos
6.
Sci Rep ; 14(1): 8214, 2024 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-38589426

RESUMEN

The feasibility of low frequency pure tone generation in the inner ear by laser-induced nonlinear optoacoustic effect at the round window was demonstrated in three human cadaveric temporal bones (TB) using an integral pulse density modulation (IPDM). Nanosecond laser pulses with a wavelength in the near-infrared (NIR) region were delivered to the round window niche by an optical fiber with two spherical lenses glued to the end and a viscous gel at the site of the laser focus. Using IPDM, acoustic tones with frequencies between 20 Hz and 1 kHz were generated in the inner ear. The sound pressures in scala tympani and vestibuli were recorded and the intracochlear pressure difference (ICPD) was used to calculate the equivalent sound pressure level (eq. dB SPL) as an equivalent for perceived loudness. The results demonstrate that the optoacoustic effect produced sound pressure levels ranging from 140 eq. dB SPL at low frequencies ≤ 200 Hz to 90 eq. dB SPL at 1 kHz. Therefore, the produced sound pressure level is potentially sufficient for patients requiring acoustic low frequency stimulation. Hence, the presented method offers a potentially viable solution in the future to provide the acoustic stimulus component in combined electro-acoustic stimulation with a cochlear implant.


Asunto(s)
Ventana Redonda , Sonido , Humanos , Estimulación Acústica , Ventana Redonda/fisiología , Rampa Timpánica/fisiología , Rayos Láser , Cóclea/fisiología
7.
J Mater Sci Mater Med ; 24(1): 129-36, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23053799

RESUMEN

Chronic otitis media is a common disease often accompanied by recurrent bacterial infections. These may lead to the destruction of the middle ear bones such that prostheses have to be implanted to restore sound transmission. Surface coatings with layered double hydroxides (LDHs) are evaluated here as a possibility for drug delivery systems with convenient advantages such as low cytotoxicity and easy synthesis. Male New Zealand White rabbits were implanted with Bioverit(®) II middle ear prostheses coated with the LDH Mg(4)Al(2)(OH)(12)(SO(4))(2)·6H(2)O impregnated with ciprofloxacin. 12 (group 1) were directly infected with Pseudomonas aeruginosa and another 12 (group 2) 1 week after the implantation. Clinical outcome, blood counts, histological analyses and microbiological examination showed an excellent antimicrobial activity for group 1, whereas this effect was attenuated in animals where infection was performed 1 week after implantation. This is the first study to demonstrate an efficient drug delivery system with an LDH coating on prostheses in the middle ear.


Asunto(s)
Antibacterianos/administración & dosificación , Ciprofloxacina/administración & dosificación , Sistemas de Liberación de Medicamentos , Oído Medio/metabolismo , Hidróxidos/química , Infecciones por Pseudomonas/tratamiento farmacológico , Animales , Antibacterianos/uso terapéutico , Ciprofloxacina/uso terapéutico , Masculino , Conejos
8.
Front Neurosci ; 17: 1202429, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37564369

RESUMEN

Introduction: In a previous study, an inner ear catheter was used to deliver low- and high-dose steroids into the cochlea prior to cochlear implant electrode insertion. With this approach, more apical regions of the cochlea could be reached and a reduction of electrode impedances in the short term was achieved in cochlear implant recipients. Whether intracochlear application of drugs via the catheter is a safe method also for patients with residual hearing has not been investigated hitherto. The aim of the present study was therefore to investigate the effect of intracochlear triamcinolone application in cochlear implant recipients with residual hearing. Patients and methods: Patients with residual hearing were administered triamcinolone-acetonide (4 mg/ml; n = 10) via an inner ear catheter just prior to insertion of a MED-EL FLEX28 electrode. Impedances were measured at defined time points (intra-operatively, post-operatively and at first fitting) and retrospectively compared with a control group (no steroid application) and low- and high-dose group. Hearing thresholds were measured preoperatively, 3 days after surgery and at first fitting by pure tone audiometry. Pre- to postoperative hearing loss was determined at first fitting and compared to results from a previous study. Results: The median hearing loss after implantation (125-1,500 Hz) was 20.6 dB. Four patients (40%) showed a median hearing loss of less than 15 dB, three patients (30%) between 15 and 30 dB and three patients (30%) more than 30 dB. The median hearing loss was similar to the results obtained from our previous study showing a median hearing loss of 24 dB when using FLEX28 electrode arrays. Conclusion: No difference in residual hearing loss was found when comparing application of triamcinolone-acetonide using an inner ear catheter prior to the insertion of a FLEX28 electrode array to the use of the FLEX28 electrode array without the catheter. Thus, we conclude that application of drugs to the cochlea with an inner ear catheter could be a feasible approach in patients with residual hearing.

9.
J Neurol ; 270(2): 1004-1010, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36331613

RESUMEN

Sjögren's syndrome is a potentially treatable cause of Small Fiber Neuropathy (SFN)-a condition that severely affects patients' quality of life. We therefore aimed to characterize patients with SFN and Sjögren's syndrome to raise awareness of this disease and facilitate its early recognition as an essential step for appropriate treatment. In 97 SFN patients (median age 48 years, 77% female), we studied the clinical features associated with Sjögren's syndrome compared to the idiopathic SFN subtype. According to the current ACR/EULAR classification criteria (Shiboski et al., Ann Rheum Dis 76:9-16, 2017), 24/97 individuals (25%, median age 48.5 years, 75% female) were diagnosed with Sjögren's syndrome. We did not observe any differences in SFN-defining sensory plus symptoms. Furthermore, intraepidermal nerve fiber densities (IENFD) were significantly lower in patients with SFN and Sjögren's syndrome (mean 2.6 ± 1.2/mm) compared to patients with idiopathic SFN (mean 3.2 ± 1.5/mm; p = 0.048). There were no significant group differences when analyzing cerebrospinal fluid (CSF) parameters. We conclude that Sjögren's syndrome-associated SFN is difficult to distinguish from idiopathic forms based on initial clinical symptoms and CSF results. However, lower IENFD values in patients with Sjögren's syndrome-associated SFN might indicate a distinct different pathomechanism in this entity compared to idiopathic SFN.


Asunto(s)
Síndrome de Sjögren , Neuropatía de Fibras Pequeñas , Humanos , Femenino , Persona de Mediana Edad , Masculino , Neuropatía de Fibras Pequeñas/complicaciones , Neuropatía de Fibras Pequeñas/diagnóstico , Síndrome de Sjögren/complicaciones , Síndrome de Sjögren/diagnóstico , Calidad de Vida , Biopsia/efectos adversos
10.
J Neurol ; 270(6): 2987-2996, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36802030

RESUMEN

OBJECTIVE: Neurological manifestations of Sjögren's syndrome can be severe but also treatment-responsive. We aimed to systematically evaluate neurological manifestations of primary Sjögren's syndrome and find clinical features allowing sufficient identification of affected patients (pSSN) among those with Sjögren's syndrome without neurological involvement (pSS). METHODS: Para-/clinical features of patients with primary Sjögren's syndrome (2016 ACR/EULAR classification criteria) were compared between pSSN and pSS. At our university-based center, patients with suggestive neurological symptoms undergo screening for Sjögren's syndrome, and newly diagnosed pSS patients are thoroughly evaluated for neurologic involvement. pSSN disease activity was rated by the Neurological Involvement of Sjögren's Syndrome Disease Activity Score (NISSDAI). RESULTS: 512 patients treated for pSS/pSSN at our site between 04/2018 and 07/2022 were included (238 pSSN patients [46%] vs. 274 pSS patients [54%], cross-sectional design). Independent predictors of neurological involvement in Sjögren's syndrome were male sex [p < 0.001], older age at disease onset [p < 0.0001], hospitalization at first presentation [p < 0.001], lower IgG levels [p = 0.04] and higher eosinophil values (treatment-naïve) [p = 0.02]. Univariate regression additionally showed older age at diagnosis [p < 0.001], lower prevalence of rheumatoid factor [p = 0.001], SSA(Ro)/SSB(La) antibodies [p = 0.03; p < 0.001], higher white blood cell count [p = 0.02] and CK levels [p = 0.02] (treatment-naïve) in pSSN. INTERPRETATION: Patients with pSSN had different clinical characteristics than patients with pSS and represented a large proportion of the cohort. Our data suggest that neurological involvement in Sjögren's syndrome has been underestimated. Intensified screening for neurologic involvement should be included in the diagnostic algorithm for Sjögren's syndrome, especially in males of older age and with severe disease course requiring hospitalization.


Asunto(s)
Síndrome de Sjögren , Humanos , Masculino , Femenino , Síndrome de Sjögren/complicaciones , Síndrome de Sjögren/diagnóstico , Estudios Transversales , Prevalencia , Progresión de la Enfermedad
11.
Hear Res ; 433: 108765, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37094529

RESUMEN

OBJECTIVES: Test feasibility of a means to distinguish artifact from relevant signal in an experimental method for pre-clinical assessment of bone conduction (BC) stimulation efficiency based on measurement of intracochlear pressure (ICP). METHODS: Experiments were performed on fresh-frozen human temporal bones and cadaver heads. In a first step, fiber optic pressure sensors inserted into the cochlea through cochleostomies were intentionally vibrated to generate relative motion versus the stationary specimen, and the resulting ICP artifact recorded, before and after attaching the sensor fiber to the bone with glue. In a second step, BC stimulation was applied in the conventional location for a commercial bone anchored implant, as well as two alternative locations closer to the otic capsule. Again, ICP was recorded and compared with an estimated artifact, calculated from the previous measurements with intentional vibration of the fiber. RESULTS: Intentional vibration of the sensor fiber creates relative motion between fiber and bone, as intended, and causes an ICP signal. The stimulus does not create substantial promontory vibration, indicating that the measured ICP is all artifact, i.e. would not occur if the sensor were not in place. Fixating the sensor fiber to the bone with glue reduces the ICP artifact by at least 20 dB. BC stimulation also creates relative motion between sensor fiber and bone, as expected, from which an estimated ICP artifact level can be calculated. The ICP signal measured during BC stimulation is well above the estimated artifact, at least in some specimens and at some frequencies, indicating "real" cochlear stimulation, which would result in an auditory percept in a live subject. Stimulation at the alternative locations closer to the otic capsule appear to result in higher ICP (no statistical analysis performed), indicating a trend towards more efficient stimulation than at the conventional location. CONCLUSIONS: Intentional vibration of the fiber optic sensor for measurement of ICP can be used to derive an estimate of the artifact to be expected when measuring ICP during BC stimulation, and to characterize the effectiveness of glues or other means of reducing the artifact caused by relative motion of fiber and bone.


Asunto(s)
Artefactos , Vibración , Humanos , Estimulación Acústica/métodos , Cóclea/fisiología , Conducción Ósea/fisiología , Cadáver
12.
Hear Res ; 421: 108369, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-34728110

RESUMEN

OBJECTIVES: The output performance of a novel semi-implantable transcutaneous bone conduction device was compared to an established percutaneous bone-anchored hearing system device using cadaver heads. The influence of actuator position, tissue growth below the actuator and mounting it on the surface or in a flattened bone bed on the performance of the implanted actuator was investigated. MATERIALS AND METHODS: The percutaneous and the new transcutaneous device were sequentially implanted at two sites in five human cadaver heads: 55 mm superior-posterior to the ear canal opening (position A) and, closer to the cochlea, about 20 mm inferior-posterior to the ear canal opening behind the pinna on the mastoid (position B). The ipsi- and contralateral cochlear promontory (CP) velocity magnitude responses to percutaneous and transcutaneous stimulation were measured using laser Doppler vibrometry. In addition, the CP vibration of the transcutaneous device placed directly on the skull bone surface was compared with the placement in a flattened bone bed at a depth of about 3 mm. Finally, the influence of placing a thin silicone interposition layer under the implanted transducer was also explored. RESULTS: The percutaneous device provided about an 11 dB higher average CP vibration level than the transcutaneous device at frequencies between 0.5 and 10 kHz. The ipsilateral CP vibration responses with stimulations at position B were on average 13 dB higher compared to stimulation at position A. The placement of the transcutaneous transducer at position B provided similar or higher average vibration magnitudes than the percutaneous transducer at position A. The 3 mm deep flattened bone bed had no significant effects on the output performance. Placing a thin silicone layer under the transcutaneous transducer had no significant influence on the output of the transcutaneous device. CONCLUSIONS: Our results using the CP vibration responses show that at frequencies above 500 Hz the new transcutaneous device at position B provides similar output levels as the percutaneous device at position A. The results also indicated that neither a bone bed for the placement of the transcutaneous transducer nor a simulated tissue growth between the actuator and the bone affect the output performance of the device.


Asunto(s)
Conducción Ósea , Audífonos , Conducción Ósea/fisiología , Cadáver , Cóclea/fisiología , Humanos , Siliconas , Vibración
13.
PLoS One ; 17(3): e0263765, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35239655

RESUMEN

Modern proteomic analysis and reliable surgical access to gain liquid inner ear biopsies have enabled in depth molecular characterization of the cochlea microenvironment. In order to clarify whether the protein composition of the perilymph can provide new insights into individual hearing performance after cochlear implantation (CI), computational analysis in correlation to clinical performance after CI were performed based on the proteome profile derived from perilymph samples (liquid biopsies). Perilymph samples from cochlear implant recipients have been analyzed by mass spectrometry (MS). The proteins were identified using the shot-gun proteomics method and quantified and analyzed using Max Quant, Perseus and IPA software. A total of 75 perilymph samples from 68 (adults and children) patients were included in the analysis. Speech perception data one year after implantation were available for 45 patients and these were used for subsequent analysis. According to their hearing performance, patients with excellent (n = 22) and poor (n = 14) performance one year after CI were identified and used for further analysis. The protein composition and statistically significant differences in the two groups were detected by relative quantification of the perilymph proteins. With this procedure, a selection of 287 proteins were identified in at least eight samples in both groups. In the perilymph of the patients with excellent and poor performance, five and six significantly elevated proteins were identified respectively. These proteins seem to be involved in different immunological processes in excellent and poor performer. Further analysis on the role of specific proteins as predictors for poor or excellent performance among CI recipients are mandatory. Combinatory analysis of molecular inner ear profiles and clinical performance data using bioinformatics analysis may open up new possibilities for patient stratification. The impact of such prediction algorithms on diagnosis and treatment needs to be established in further studies.


Asunto(s)
Proteoma
14.
J Clin Med ; 11(20)2022 Oct 16.
Artículo en Inglés | MEDLINE | ID: mdl-36294411

RESUMEN

Anatomical malformations, obliterations of the cochlea, or re-implantations pose particular challenges in cochlear implantation. Treatment methods rely on radiological and intraoperative findings and include incomplete insertion, the implantation of a double array, and radical cochleostomy. In addition, a stiff electrode array, e.g., the IE stiff (IES) custom-made device (CMD, MED-EL), was prescribed individually for those special cases and pre-inserted prior to facilitate cochlear implantation in challenging cases. Data on outcomes after implantation in obliterated cochleae are usually based on individual case reports since standardised procedures are lacking. A retrospective analysis was conducted to analyse our cases on obliterated cochleae treated with MED-EL devices in order to allow the different cases to be compared. Impedances and speech perception data of patients treated with the IES CMD and the double array were retrospectively compared to patients treated with a STANDARD or FLEX electrode array (the REGULAR group). Patients with a Split-Array CMD had a poor speech perception when compared to patients treated with the IES CMD device. Thus, the IES CMD can successfully be used in patients with obliterated cochleae who would otherwise be non-users, candidates for a Split-Array CMD, or candidates for partial insertion with insufficient cochlear coverage.

15.
J Clin Med ; 11(15)2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-35956101

RESUMEN

BACKGROUND: Patients with Sjögren's syndrome and polyneuropathy more frequently develop cranial nerve affection when compared to patients with chronic inflammatory demyelinating polyneuropathy (CIDP). We therefore aimed to analyze trigeminal corneal nerve fibre characteristics in both patient groups. METHODS: A total of 26 patients with Sjögren's syndrome associated neuropathy and 29 patients with CIDP were recruited at our university hospital and compared to 6 healthy controls. Dry eye symptoms and signs were assessed via clinical examination and the Ocular Disease Surface Index questionnaire. Trigeminal corneal nerve fibres were analyzed via corneal confocal microscopy (CCM) as a non-invasive in vivo microscopy. RESULTS: CCM revealed significantly reduced corneal nerve fibre density and corneal nerve fibre main branch density in the Neuro-Sjögren group when compared with healthy controls. There were no significant group differences between the Neuro-Sjögren and the CIDP group for any of the microscopic parameters. Dry eye assessment showed similarly reduced scores for both patient groups, while healthy controls showed better results for objective dry eye signs. There was no correlation between microscopic parameters of the corneal confocal microscopy and parameters of dry eye assessment. CONCLUSIONS: Our data revealed trigeminal corneal nerve affection in patients with neuropathy associated with Sjögren's syndrome and patients with CIDP detected by CCM. No difference was found between both neuropathy groups indicating that CCM is not able to distinguish between both entities.

16.
Otol Neurotol ; 42(6): e690-e697, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34111049

RESUMEN

INTRODUCTION: This study aims to investigate the performance of an active middle ear implant actuator for various coupling configurations. Actuator output and conductive losses were measured, and the stability of coupling was evaluated by challenging the link between actuator and ossicles through pressure events in magnitudes that occur in daily life. METHODS: Actuator coupling efficiency and the occurrence of conductive losses were measured in 10 temporal bones through laser Doppler vibrometry on the stapes footplate for various coupling types (incus short process with and without laser hole, incus long process, stapes head). To test the stability of coupling, actuator output was measured before and after daily-life pressure events that were simulated; Valsalva maneuvers (500 cycles of -40 to +60 hPa) and jumping into a swimming pool and diving 3 m deep (a step change of 300 hPa). RESULTS: Actuator output was similarly high for all types of coupling to the incus (short process and long process) and most efficient for coupling to the stapes head. Conductive losses occurred in two temporal bones (TBs) for short process coupling but for seven TBs for coupling to the incus long process. All coupling types were stable and did not lose efficiency after pressure events in the low-frequency range (<1 kHz). Losses in output of 13 to 24 dB were observed in one TB at frequencies from 3 to 6 kHz. CONCLUSION: Actuator output was similarly high for all types of coupling to the incus but coupling to the incus long process led to a higher occurrence of conductive losses. All three coupling configurations connected the actuator securely to the ossicular chain, under variations of barometric pressure that can be expected in daily life.


Asunto(s)
Prótesis Osicular , Oído Medio/cirugía , Humanos , Yunque/cirugía , Estribo , Hueso Temporal/cirugía , Vibración
17.
J Neuroimaging ; 31(6): 1156-1165, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34270142

RESUMEN

BACKGROUND AND PURPOSE: The phenotype of Sjögren's syndrome-associated neuropathy has been better characterized in recent years. However, Sjögren's syndrome-associated neuropathy remains an underdiagnosed entity with only few insights considering the pathomechanisms of nerve damage. Nerve ultrasound has proven to be a useful and efficient tool in detecting nerve damage of autoimmune origin. We, therefore, aimed to evaluate this method for Sjögren's syndrome-associated neuropathy. METHODS: Patients with Sjögren's syndrome and clinical signs of neuropathy underwent sonographic examination of both median and ulnar nerves. Nerve thickening was classified for cross-sectional areas of >12 mm² at the median nerve and for >10 mm² at the ulnar nerve. Fascicle thickening was documented for cross-sectional areas ≥5 mm² at the median and ≥3 mm² at the ulnar nerve. RESULTS: Forty-three patients were included in the analysis (median age 60 years [interquartile range 53-73 years], female rate 60%). 31/43 patients (72%) showed abnormalities on nerve ultrasound, while nerve thickening was found more frequently than fascicle thickening (90% vs. 52% of patients with sonographic abnormalities, respectively). Abnormal findings were observed more frequently at the median nerve and in proximal localization. Abnormal findings on nerve conduction studies were evident in 36/43 patients (84%). Nerve conduction studies revealed a tendency of demyelinating nerve damage patterns being associated with abnormal findings on nerve ultrasound. CONCLUSIONS: In addition to nerve conduction studies, nerve ultrasound may have a supporting role in the diagnosis of Sjögren's syndrome-associated neuropathy. Also, our data support an immune-mediated inflammatory demyelinating pathogenesis of Sjögren's syndrome-associated neuropathy.


Asunto(s)
Enfermedades del Sistema Nervioso Periférico , Síndrome de Sjögren , Femenino , Humanos , Examen Neurológico/efectos adversos , Enfermedades del Sistema Nervioso Periférico/diagnóstico por imagen , Enfermedades del Sistema Nervioso Periférico/etiología , Síndrome de Sjögren/complicaciones , Síndrome de Sjögren/diagnóstico por imagen , Ultrasonografía/efectos adversos
18.
ACS Omega ; 6(33): 21241-21254, 2021 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34471729

RESUMEN

Despite a vast amount of data generated by proteomic analysis on cochlear fluid, novel clinically applicable biomarkers of inner ear diseases have not been identified hitherto. The aim of the present study was to analyze the proteome of human perilymph from cochlear implant patients, thereby identifying putative changes of the composition of the cochlear fluid perilymph due to specific diseases. Sampling of human perilymph was performed during cochlear implantation from patients with clinically or radiologically defined inner ear diseases like enlarged vestibular aqueduct (EVA; n = 14), otosclerosis (n = 10), and Ménière's disease (n = 12). Individual proteins were identified by a shotgun proteomics approach and data-dependent acquisition, thereby revealing 895 different proteins in all samples. Based on quantification values, a disease-specific protein distribution in the perilymph was demonstrated. The proteins short-chain dehydrogenase/reductase family 9C member 7 and esterase D were detected in nearly all samples of Ménière's disease patients, but not in samples of patients suffering from EVA and otosclerosis. The presence of both proteins in the inner ear tissue of adult mice and neonatal rats was validated by immunohistochemistry. Whether these proteins have the potential for a biomarker in the perilymph of Ménière's disease patients remains to be elucidated.

19.
J Neurol ; 268(8): 2908-2912, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33611611

RESUMEN

BACKGROUND: This study addresses the challenging characterisation and differentiation of CIDP versus CIDP in association with Sjögren's syndrome to facilitate the process in clinical routine. METHODS: Patients with both CIDP and Sjögren's syndrome and CIDP without Sjögren's syndrome were compared concerning relevant differences in clinical, laboratory and electrophysiological findings. 154 patients who fulfilled the diagnostic EFNS/PNS criteria for CIDP were included in the analysis. 54 of these patients additionally fulfilled the ACR/EULAR classification criteria for Sjögren's syndrome. RESULTS: The frequency of female patients was higher in patients with CIDP and Sjögren's syndrome (52%) versus CIDP patients without Sjögren's syndrome (28%). Furthermore, the occurrence of cranial nerve impairment was significantly higher in patients with Sjögren's syndrome (39% versus 14%). There were no significant group differences in the evaluation of initial symptoms, severity of disability judged by INCAT disability scale score, presence or distribution of sensory deficits, limb weakness and the presence of ataxia, pain or dysautonomia, CSF laboratory or electrophysiological findings. CONCLUSIONS: In conclusion, our data indicate that cranial nerve impairment and female gender might represent red flags for an additional Sjögren's syndrome in patients with CIDP. The patterns of clinical disabilities and electrophysiological findings due to peripheral nerve damage are similar in both CIDP entities.


Asunto(s)
Polirradiculoneuropatía Crónica Inflamatoria Desmielinizante , Síndrome de Sjögren , Ataxia , Femenino , Humanos , Debilidad Muscular , Polirradiculoneuropatía Crónica Inflamatoria Desmielinizante/complicaciones , Polirradiculoneuropatía Crónica Inflamatoria Desmielinizante/diagnóstico , Polirradiculoneuropatía Crónica Inflamatoria Desmielinizante/epidemiología , Síndrome de Sjögren/complicaciones , Síndrome de Sjögren/diagnóstico , Síndrome de Sjögren/epidemiología
20.
J Extracell Vesicles ; 10(8): e12094, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34136108

RESUMEN

Extracellular vesicles (EVs) derived from the secretome of human mesenchymal stromal cells (MSC) contain numerous factors that are known to exert anti-inflammatory effects. MSC-EVs may serve as promising cell-based therapeutics for the inner ear to attenuate inflammation-based side effects from cochlear implantation which represents an unmet clinical need. In an individual treatment performed on a 'named patient basis', we intraoperatively applied allogeneic umbilical cord-derived MSC-EVs (UC-MSC-EVs) produced according to good manufacturing practice. A 55-year-old patient suffering from Menière's disease was treated with intracochlear delivery of EVs prior to the insertion of a cochlear implant. This first-in-human use of UC-MSC-EVs demonstrates the feasibility of this novel adjuvant therapeutic approach. The safety and efficacy of intracochlear EV-application to attenuate side effects of cochlea implants have to be determined in controlled clinical trials.


Asunto(s)
Implantación Coclear/métodos , Vesículas Extracelulares/trasplante , Trasplante de Células Madre Mesenquimatosas/métodos , Diferenciación Celular , Implantes Cocleares/efectos adversos , Citocinas/metabolismo , Oído Interno/citología , Vesículas Extracelulares/metabolismo , Humanos , Masculino , Células Madre Mesenquimatosas/fisiología , Persona de Mediana Edad , Proyectos Piloto , Cordón Umbilical/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA