1.
J Nucl Cardiol ; 23(1): 11-20, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26012642

RESUMEN

BACKGROUND: Previous studies have demonstrated accurate diagnosis of reduced dose myocardial perfusion imaging (MPI) using Cadmium-Zinc-Telluride (CZT) technology. We compared the diagnostic performances of very low stress-dose (<2 mSv) with standard-dose stress-first, quantitative MPI using a CZT camera. METHODS: Patients without known coronary artery- disease who underwent a stress-first Tc-99 m sestamibi CZT-MPI and invasive coronary angiography (ICA), and low-risk patients without ICA were included. A stress-rest standard-dose (10/30 mCi) MPI and a low-dose (5/15 mCi) MPI were compared. Normal limits for quantification were developed from 40 (20 males) low-risk patients, and total perfusion deficit (TPD) was derived. RESULTS: 208 patients who underwent MPI and ICA, and 76 low-risk patients were included. Of these, 128 had a standard-dose MPI and 156 had a low-dose MPI. Stress-doses in low-dose and standard-dose groups were 5.9 ± 1.2 vs 10.2 ± 0.5 mCi (1.7 ± 0.3 vs 3.0 ± 0.1 mSv), respectively, P < 0.001, and stress-rest effective radiation was 6.9 ± 1.1 vs 11.7 ± 0.4 mSv, respectively, P < 0.001. Sensitivity, specificity, and accuracy values in the low-dose and standard-dose groups were 86.1%, 76.6%, and 81.4%; and 90.6%, 78.1%, and 84.4%, respectively, P = ns. Using TPD prone, specificity values were 84.9% and 80.3%, respectively, P = ns. CONCLUSION: One-day stress-first MPI with 50% radiation reduction and a very low stress-dose (<2 mSv) using CZT technology and quantitative supine and prone analysis provided a high diagnostic value, similar to standard-dose MPI.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Cámaras gamma , Imagen de Perfusión Miocárdica/instrumentación , Reconocimiento de Normas Patrones Automatizadas/métodos , Tecnecio Tc 99m Sestamibi/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Relación Dosis-Respuesta a Droga , Diseño de Equipo , Análisis de Falla de Equipo , Prueba de Esfuerzo/instrumentación , Prueba de Esfuerzo/métodos , Femenino , Humanos , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/métodos , Radiofármacos/administración & dosificación , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad
2.
Harefuah ; 154(4): 224-7, 281, 2015 Apr.
Artículo en Hebreo | MEDLINE | ID: mdl-26065214

RESUMEN

BACKGROUND: Myocardial perfusion imaging (MPI) is valuable for diagnosing coronary disease and assessing the risk of cardiac events. New technology based on semiconductors (Cadmium zinc telluride-CZT) enables reducing imaging time and improving image quality. METHODS: We retrospectively identified 57 patients who underwent MPI at Assuta using a CZT camera and invasive coronary angiography (ICA) within 60 days following nuclear testing without an intervening cardiac event, and without history of coronary disease. In addition, 25 patients with low pretest likelihood who did not undergo ICA were included in the study. All 82 patients underwent fast-acquisition, stress-first Tc-99m sestamibi MPI using very short imaging time (stress: 5:00 min., prone: 3:40 min. and rest: 2:00 min]. A low-dose stress injection (9-12 mCi, ≤ 3.5 mSv) and high rest-dose (25-32 mCi) with adjustment to patient weight were administered. Semi-quantitative visual analysis utilized a 17-segment model, 0-4 scale (0 = normal uptake, 4 = absent uptake). The summed stress score (SSS) representing stress perfusion abnormality was converted to a percentage of abnormal myocardium (SSS% = SSS/68*100). ICA served as a gold standard for the nuclear perfusion findings. RESULTS: The mean age was 60.1 ± 11 years and most subjects were men (58, 70.7%). Compared to low-risk patients, patients who underwent ICAwere older, and had a higher frequency of hypertension, diabetes mellitus and dyslipidemia. A low-dose stress-only test with low radiation exposure ≤ 3.5 mSv) was frequent among low-risk patients (18/25-72%). ROC analysis for identification of angiographic coronary disease by SSS% demonstrated area under curve of 0.923, 95% confidence interval 0.859-0.988, p < 0.001. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were: 91.4%, 81.2%, 78.3%, 97.2% and 86.6%, respectively. CONCLUSION: Fast, low-dose stress MPI using CZT technology enables semi-quantitative analysis with high diagnostic value for coronary disease.


Asunto(s)
Cadmio , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico , Imagen de Perfusión Miocárdica/métodos , Telurio , Zinc , Anciano , Enfermedad Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Tecnecio Tc 99m Sestamibi , Factores de Tiempo