Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Mol Pharm ; 7(1): 12-21, 2010 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-19621944

RESUMEN

Simultaneous labeling of the drug compartment and shell of delivery vehicles with optical and positron emission tomography (PET) probes is developed and employed to inform a hybrid physiologically based pharmacokinetic model. Based on time-dependent estimates of the concentration of these tracers within the blood pool, reticuloendothelial system (RES) and tumor interstitium, we compare the stability and circulation of long-circulating and temperature-sensitive liposomes. We find that rates of transport to the RES for long-circulating and temperature-sensitive particles are 0.046 and 0.19 h(-1), respectively. Without the application of exogenous heat, the rates of release from the long-circulating and temperature-sensitive particles circulating within the blood pool are 0.003 and 0.2 h(-1), respectively. Prolonged lifetime in circulation and slow drug release from liposomes result in a significantly greater drug area under the curve for the long-circulating particles. Future studies will couple these intrinsic parameters with exogenous heat-based release. Finally, we develop a transport constant for the transport of liposomes from the blood pool to the tumor interstitium, which is on the order of 0.01 h(-1) for the Met-1 tumor system.


Asunto(s)
Sistemas de Liberación de Medicamentos , Liposomas , Modelos Biológicos , Animales , Permeabilidad Capilar , Diseño de Fármacos , Estabilidad de Medicamentos , Femenino , Colorantes Fluorescentes , Técnicas In Vitro , Ratones , Sistema Mononuclear Fagocítico/diagnóstico por imagen , Sistema Mononuclear Fagocítico/metabolismo , Nanopartículas , Neoplasias Experimentales/irrigación sanguínea , Neoplasias Experimentales/diagnóstico por imagen , Neoplasias Experimentales/metabolismo , Farmacocinética , Tomografía de Emisión de Positrones
2.
J Acoust Soc Am ; 128(3): 1511-21, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20815486

RESUMEN

The Rayleigh-Plesset (RP) equation for a clean gas bubble in an incompressible and infinite liquid has previously been applied to approximately simulate the behavior of ultrasound contrast agents (UCA) in vivo, and extended RP equations have been proposed to account for the effects of the UCA shell or surrounding soft tissue. These models produce results that are consistent with experimental measurements for low acoustic pressure scenarios. For applications of UCAs in therapeutic medicine, the transmitted acoustic pulse can have a peak negative pressure (PNP) up to a few megapascals, resulting in discrepancies between measurements and predictions using these extended RP equations. Here, a model was developed to describe the dynamics of UCAs in vivo while taking account of the effects of liquid compressibility, the shell and the surrounding tissue. Liquid compressibility is approximated to first order and the shell is treated either as a Voigt viscoelastic solid or a Newtonian viscous liquid. Finite deformation of the shell and tissue is derived. Dynamics of UCAs with a shell of lipid, polymer, albumin and liquid are investigated for typical therapeutic ultrasound pulses. The effects of liquid compressibility and shell and tissue parameters are analyzed.


Asunto(s)
Medios de Contraste/química , Microburbujas , Modelos Químicos , Ultrasonografía/métodos , Medios de Contraste/administración & dosificación , Elasticidad , Presión , Reproducibilidad de los Resultados , Propiedades de Superficie , Factores de Tiempo , Viscosidad
3.
Phys Med Biol ; 54(6): R27-57, 2009 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-19229096

RESUMEN

Microbubble contrast agents and the associated imaging systems have developed over the past 25 years, originating with manually-agitated fluids introduced for intra-coronary injection. Over this period, stabilizing shells and low diffusivity gas materials have been incorporated in microbubbles, extending stability in vitro and in vivo. Simultaneously, the interaction of these small gas bubbles with ultrasonic waves has been extensively studied, resulting in models for oscillation and increasingly sophisticated imaging strategies. Early studies recognized that echoes from microbubbles contained frequencies that are multiples of the microbubble resonance frequency. Although individual microbubble contrast agents cannot be resolved-given that their diameter is on the order of microns-nonlinear echoes from these agents are used to map regions of perfused tissue and to estimate the local microvascular flow rate. Such strategies overcome a fundamental limitation of previous ultrasound blood flow strategies; the previous Doppler-based strategies are insensitive to capillary flow. Further, the insonation of resonant bubbles results in interesting physical phenomena that have been widely studied for use in drug and gene delivery. Ultrasound pressure can enhance gas diffusion, rapidly fragment the agent into a set of smaller bubbles or displace the microbubble to a blood vessel wall. Insonation of a microbubble can also produce liquid jets and local shear stress that alter biological membranes and facilitate transport. In this review, we focus on the physical aspects of these agents, exploring microbubble imaging modes, models for microbubble oscillation and the interaction of the microbubble with the endothelium.


Asunto(s)
Medios de Contraste/uso terapéutico , Ingeniería , Microburbujas , Fenómenos Físicos , Ultrasonido , Animales , Humanos , Modelos Biológicos
4.
J Acoust Soc Am ; 125(5): EL183-9, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19425620

RESUMEN

Insonified microbubbles were observed in vessels within a gel with a Young's modulus similar to that of tissue, demonstrating shape instabilities, liquid jets, and the formation of small tunnels. In this study, tunnel formulation occurred in the direction of the propagating ultrasound wave, where radiation pressure directed the contact of the bubble and gel, facilitating the activity of the liquid jets. Combinations of ultrasonic parameters and microbubble concentrations that are relevant for diagnostic imaging and drug delivery and that lead to tunnel formation were applied and the resulting tunnel formation was quantified.


Asunto(s)
Microburbujas , Fantasmas de Imagen , Ultrasonido , Ultrasonografía , Módulo de Elasticidad
5.
Ultrasound Med Biol ; 34(6): 1014-20, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18395962

RESUMEN

Silica, cellulose and polymethylmethacrylate tubes with inner diameters of ten to a few hundred microns are commonly used as blood vessel phantoms in in vitro studies of microbubble or nanodroplet behavior during insonation. However, a detailed investigation of the ultrasonic fields within these micro-tubes has not yet been performed. This work provides a theoretical analysis of the ultrasonic fields within micro-tubes. Numerical results show that for the same tube material, the interaction between the micro-tube and megaHertz-frequency ultrasound may vary drastically with incident frequency, tube diameter and wall thickness. For 10 MHz ultrasonic insonation of a polymethylmethacrylate (PMMA) tube with an inner diameter of 195 microm and an outer diameter of 260 microm, the peak pressure within the tube can be up to 300% of incident pressure amplitude. However, using 1 MHz ultrasound and a silica tube with an inner diameter of 12 microm and an outer diameter of 50 microm, the peak pressure within the tube is only 12% of the incident pressure amplitude and correspondingly, the spatial-average-time-average intensity within the tube is only 1% of the incident intensity.


Asunto(s)
Algoritmos , Capilares/diagnóstico por imagen , Simulación por Computador , Fantasmas de Imagen , Ultrasonografía/métodos , Aluminio , Celulosa , Medios de Contraste , Diseño de Equipo , Vidrio , Humanos , Microburbujas , Polimetil Metacrilato , Presión , Dióxido de Silicio , Ultrasonografía/instrumentación
6.
Sci Rep ; 8(1): 16347, 2018 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-30397280

RESUMEN

Microbubble contrast agents are widely used in ultrasound imaging and therapy, typically with transmission center frequencies in the MHz range. Currently, an ultrasound center frequency near 250 kHz is proposed for clinical trials in which ultrasound combined with microbubble contrast agents is applied to open the blood brain barrier, since at this low frequency focusing through the human skull to a predetermined location can be performed with reduced distortion and attenuation compared to higher frequencies. However, the microbubble vibrational response has not yet been carefully evaluated at this low frequency (an order of magnitude below the resonance frequency of these contrast agents). In the past, it was assumed that encapsulated microbubble expansion is maximized near the resonance frequency and monotonically decreases with decreasing frequency. Our results indicated that microbubble expansion was enhanced for 250 kHz transmission as compared with the 1 MHz center frequency. Following 250 kHz insonation, microbubble expansion increased nonlinearly with increasing ultrasonic pressure, and was accurately predicted by either the modified Rayleigh-Plesset equation for a clean bubble or the Marmottant model of a lipid-shelled microbubble. The expansion ratio reached 30-fold with 250 kHz at a peak negative pressure of 400 kPa, as compared to a measured expansion ratio of 1.6 fold for 1 MHz transmission at a similar peak negative pressure. Further, the range of peak negative pressure yielding stable cavitation in vitro was narrow (~100 kPa) for the 250 kHz transmission frequency. Blood brain barrier opening using in vivo transcranial ultrasound in mice followed the same trend as the in vitro experiments, and the pressure range for safe and effective treatment was 75-150 kPa. For pressures above 150 kPa, inertial cavitation and hemorrhage occurred. Therefore, we conclude that (1) at this low frequency, and for the large oscillations, lipid-shelled microbubbles can be approximately modeled as clean gas microbubbles and (2) the development of safe and successful protocols for therapeutic delivery to the brain utilizing 250 kHz or a similar center frequency requires consideration of the narrow pressure window between stable and inertial cavitation.


Asunto(s)
Medios de Contraste , Microburbujas , Ondas Ultrasónicas , Animales , Barrera Hematoencefálica/metabolismo , Medios de Contraste/metabolismo , Imagen por Resonancia Magnética , Ratones , Imagen Óptica , Presión
7.
Ultrasound Med Biol ; 33(7): 1140-8, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17478030

RESUMEN

Ultrasound contrast agents (UCAs) are under intensive investigation for their applications in physiological and molecular imaging and drug delivery. Prediction of the natural frequency of the oscillation of UCAs in microvessels has drawn increasing attention. To our knowledge, the existing models to predict the natural frequency of oscillation of UCAs in microvessels all apply the linear approximation and treat the blood vessel wall as a rigid boundary. In the potential applications of ultrasound imaging drug and gene delivery, the compliance of small vessels may play an important role in the bubble's oscillation. The goal of this work is to provide a lumped-parameter model to study the natural frequency of nonlinear oscillation of UCAs in microvessels. Three types of the blood vessel conditions have been considered: i.e., rigid vessels, normal compliable vessels and vessels with increasing stiffness that could correspond to tumor vasculature. The corresponding bubble oscillation frequencies in vessels with a radius less than 100 microm are examined in detail. When a bubble with a radius of 4 microm is confined in a compliable vessel (inner radius 5 microm and length 100 microm), the natural frequency of bubble oscillation increases by a factor of 1.7 compared with a bubble in an unbounded field. The natural frequency of oscillation of a bubble in a compliable vessel increases with decreasing vessel size while decreasing with increasing values of vessel rigidity. This model suggests that contrast agent size, blood vessel size distribution and the type of vasculature should comprehensively be considered for choosing the transmitted frequency in ultrasound contrast imaging and drug delivery.


Asunto(s)
Microburbujas , Microcirculación , Animales , Anuros , Capilares/anatomía & histología , Elasticidad , Modelos Cardiovasculares , Estrés Mecánico , Ultrasonido
8.
Ultrasound Med Biol ; 33(12): 1978-87, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17900793

RESUMEN

The use of ultrasound radiation force to manipulate microbubbles in blood vessels has attracted recent interest as a method to increase the efficiency of ultrasonic molecular imaging and drug delivery. However, recent studies indicate that microbubble oscillation is diminished within small blood vessels, and therefore we investigate microbubble oscillation and translation within 12 microm vessels using high-speed photography. With each 0.1- to 1-MPa ultrasound pulse, microbubbles (radius of 1, 1.5 and 2 microm) within 12 microm tubes translate 5 to 10 times less than those within 200 microm tubes. Application of a pulse train with a high pulse repetition frequency displaces bubbles to the wall of 12- and 200-microm tubes within an interval ( approximately 1 s) that is reasonable for clinical translation. Modeling of coupled oscillation and translation for unconstrained microbubbles, based on a modified Rayleigh-Plesset (RP) and the trajectory equations, is compared with experimental observations and demonstrates agreement for the larger displacements observed within the 200 microm tubes. This study has implications for contrast-assisted ultrasound applications, aiding the manipulation of targeted microbubbles and for further theoretical understanding of the complex bubble dynamics within constrained vessel.


Asunto(s)
Microburbujas , Microcirculación/diagnóstico por imagen , Medios de Contraste , Humanos , Modelos Cardiovasculares , Fantasmas de Imagen , Fotograbar , Ultrasonografía
9.
J Acoust Soc Am ; 122(2): 1191-200, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17672665

RESUMEN

Many thousands of contrast ultrasound studies have been conducted in clinics around the world. In addition, the microbubbles employed in these examinations are being widely investigated to deliver drugs and genes. Here, for the first time, the oscillation of these microbubbles in small vessels is directly observed and shown to be substantially different than that predicted by previous models and imaged within large fluid volumes. Using pulsed ultrasound with a center frequency of 1 MHz and peak rarefactional pressure of 0.8 or 2.0 MPa, microbubble expansion was significantly reduced when microbubbles were constrained within small vessels in the rat cecum (p<0.05). A model for microbubble oscillation within compliant vessels is presented that accurately predicts oscillation and vessel displacement within small vessels. As a result of the decreased oscillation in small vessels, a large resting microbubble diameter resulting from agent fusion or a high mechanical index was required to bring the agent shell into contact with the endothelium. Also, contact with the endothelium was observed during asymmetrical collapse, not during expansion. These results will be used to improve the design of drug delivery techniques using microbubbles.


Asunto(s)
Arteriolas/fisiología , Microcirculación/fisiología , Ultrasonido , Vénulas/fisiología , Permeabilidad Capilar , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por Computador , Oscilometría , Presión , Sensibilidad y Especificidad
10.
Phys Med Biol ; 51(20): 5065-88, 2006 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-17019026

RESUMEN

The existing models of the dynamics of ultrasound contrast agents (UCAs) have largely been focused on an UCA surrounded by an infinite liquid. Preliminary investigations of a microbubble's oscillation in a rigid tube have been performed using linear perturbation, under the assumption that the tube diameter is significantly larger than the UCA diameter. In the potential application of drug and gene delivery, it may be desirable to fragment the agent shell within small blood vessels and in some cases to rupture the vessel wall, releasing drugs and genes at the site. The effect of a compliant small blood vessel on the UCA's oscillation and the microvessel's acoustic response are unknown. The aim of this work is to propose a lumped-parameter model to study the interaction of a microbubble oscillation and compliable microvessels. Numerical results demonstrate that in the presence of UCAs, the transmural pressure through the blood vessel substantially increases and thus the vascular permeability is predicted to be enhanced. For a microbubble within an 8 to 40 microm vessel with a peak negative pressure of 0.1 MPa and a centre frequency of 1 MHz, small changes in the microbubble oscillation frequency and maximum diameter are observed. When the ultrasound pressure increases, strong nonlinear oscillation occurs, with an increased circumferential stress on the vessel. For a compliable vessel with a diameter equal to or greater than 8 microm, 0.2 MPa PNP at 1 MHz is predicted to be sufficient for microbubble fragmentation regardless of the vessel diameter; however, for a rigid vessel 0.5 MPa PNP at 1 MHz may not be sufficient to fragment the bubbles. For a centre frequency of 1 MHz, a peak negative pressure of 0.5 MPa is predicted to be sufficient to exceed the stress threshold for vascular rupture in a small (diameter less than 15 microm) compliant vessel. As the vessel or surrounding tissue becomes more rigid, the UCA oscillation and vessel dilation decrease; however the circumferential stress is predicted to increase. Decreasing the vessel size or the centre frequency increases the circumferential stress. For the two frequencies considered in this work, the circumferential stress does not scale as the inverse of the square root of the acoustic frequency va as in the mechanical index, but rather has a stronger frequency dependence, 1/va.


Asunto(s)
Medios de Contraste , Ecocardiografía/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Microburbujas , Microcirculación/diagnóstico por imagen , Microcirculación/fisiología , Modelos Cardiovasculares , Acústica , Elasticidad , Humanos , Tamaño de la Partícula , Estrés Mecánico
11.
Artículo en Inglés | MEDLINE | ID: mdl-16889339

RESUMEN

This paper presents a detailed study of the oscillation characteristics of a bubble confined inside a deformable microvessel, whose size is comparable with the bubble size. The vessel's compliance is characterized by a nonlinear relation between the intraluminal pressure and the expansion ratio of the vessel radius, which represents the variation of the vessel stiffness with the pressure of the filling liquid. In this analysis, an initially spherical bubble evolves into an ellipsoid, and the asymmetric oscillation appears immediately after the driving pressure is applied and magnifies with oscillation cycles. Compared with the symmetric oscillation in an unconstrained environment, the vessel constraint makes the bubble contract significantly more and subsequently expand in a more violent rebound, inducing substantially larger peaks of the intraluminal pressure exerted on the vessel wall. A larger initial bubble/vessel radius ratio leads to not only a larger peak but also a higher oscillation frequency of the intraluminal pressure, which are the two most dominating parameters in determining the vessel's failure under cyclic loading. The numerical results have further shown that an increase of the vessel wall stiffness strengthens the asymmetric effect, i.e., a larger peak of the intraluminal pressure with a higher oscillation frequency, and so does a larger pre-existing pressure in the liquid filling the vessel. These findings imply that the asymmetric effect is one of the primary mechanisms for clinical injuries of capillary and small blood vessels and for the higher risk of pediatric and hypertension patients in shock wave lithotripsy.


Asunto(s)
Relojes Biológicos , Gases/efectos de la radiación , Litotricia/efectos adversos , Microcirculación/lesiones , Microcirculación/efectos de la radiación , Modelos Cardiovasculares , Animales , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Elasticidad , Humanos , Microcirculación/fisiopatología , Presión , Dosis de Radiación , Medición de Riesgo/métodos , Factores de Riesgo , Estrés Mecánico
12.
Nucl Med Biol ; 42(2): 155-63, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25451215

RESUMEN

(89)Zr (t1/2=78.4h), a positron-emitting metal, has been exploited for PET studies of antibodies because of its relatively long decay time and facile labeling procedures. Here, we used (89)Zr to evaluate the pharmacokinetics of long-circulating liposomes over 168h (1week). We first developed a liposomal-labeling method using p-isothiocyanatobenzyl-desferrioxamine (df-Bz-NCS) and df-PEG1k-DSPE. Df-Bz-NCS was conjugated to 1mol% amino- and amino-PEG2k-DSPE, where the 1mol% df-PEG1k-DSPE was incorporated when the liposomes were formulated. Incubation of (89)Zr with df, df-PEG1k, and df-PEG2k liposomes for one hour resulted in greater than 68% decay-corrected yield. The loss of the (89)Zr label from liposomes after incubation in 50% human serum for 48h ranged from ~1 to 3% across the three formulations. Tail vein administration of the three liposomal formulations in NDL tumor-bearing mice showed that the (89)Zr label at the end of the PEG2k brush was retained in the tumor, liver, spleen and whole body for a longer time interval than (89)Zr labels located under the PEG2k brush. The blood clearance rate of all three liposomal formulations was similar. Overall, the results indicate that the location of the (89)Zr label altered the clearance rate of intracellularly-trapped radioactivity and that df-PEG1k-DSPE provides a stable chelation site for liposomal or lipid-based particle studies over extended periods of time.


Asunto(s)
Liposomas/farmacocinética , Neoplasias Mamarias Experimentales/diagnóstico por imagen , Radioisótopos , Circonio , Animales , Química Farmacéutica , Deferoxamina/química , Modelos Animales de Enfermedad , Estabilidad de Medicamentos , Humanos , Marcaje Isotópico , Liposomas/química , Ratones , Fosfatidiletanolaminas/química , Polietilenglicoles/química , Tomografía de Emisión de Positrones , Distribución Tisular
13.
Artículo en Inglés | MEDLINE | ID: mdl-15301000

RESUMEN

This work examines the characteristic differences in acoustic scattering between air-filled double-layered encapsulating (DLE) shells and air-filled single-layered encapsulating (SLE) shells. The analysis shows that the presence of an outer layer softer than the inner layer results in a shift of the first monopole of the reflectivity-frequency response to a higher frequency and a reduction in the monopole peak; and it leads to a frequency-separation of the two dipoles that trace the monopole. The frequency shift and the peak reduction of the monopole and the frequency separation of the two dipoles all increase with the increasing thickness of the softer outer layer. The numerical results reveal that variations in the Lame constant of the model material for the protein albumin have little effect on the low-frequency scattering characteristics, while they affect the high-frequency scattering characteristics significantly. The authors have shown that this phenomenon is due to the fact that the model material for the protein albumin has a Lame constant substantially larger than its shear modulus. Their further numerical studies conclude that, for each DLE shell, one can construct an equivalent SLE shell, using a simple scheme originated from the mechanics of composite materials in the sense that the so-constructed SLE shell has essentially the same acoustic scattering characteristics as the DLE shell within a low frequency range.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/efectos de la radiación , Portadores de Fármacos/química , Portadores de Fármacos/efectos de la radiación , Microburbujas , Modelos Químicos , Simulación por Computador , Sistemas de Liberación de Medicamentos/métodos , Ensayo de Materiales , Dispersión de Radiación , Ultrasonido
14.
Ann Biomed Eng ; 42(2): 280-98, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24018607

RESUMEN

Our goal is to provide a physiological perspective on the use of imaging to optimize and monitor the accumulation of nanotherapeutics within target tissues, with an emphasis on evaluating the pharmacokinetics of organic particles. Positron emission tomography (PET), magnetic resonance imaging (MRI) and ultrasound technologies, as well as methods to label nanotherapeutic constructs, have created tremendous opportunities for preclinical optimization of therapeutics and for personalized treatments in challenging disease states. Within the methodology summarized here, the accumulation of the construct is estimated directly from the image intensity. Particle extravasation is then estimated based on classical physiological measures. Specifically, the transport of nanotherapeutics is described using the concept of apparent permeability, which is defined as the net flux of solute across a blood vessel wall per unit surface area of the blood vessel and per unit solute concentration difference across the blood vessel wall. The apparent permeability to small molecule MRI constructs is accurately shown to be far larger than that estimated for proteins such as albumin or nanoconstructs such as liposomes. Further, the quantitative measurements of vascular permeability are shown to facilitate detection of the transition from a pre-malignant to a malignant cancer and to quantify the delivery enhancement resulting from interventions such as ultrasound. While PET-based estimates facilitate quantitative comparisons of many constructs, high field MRI proves useful in the visualization of model drugs within small lesions and in the evaluation of the release and intracellular trafficking of nanoparticles and cargo.


Asunto(s)
Antineoplásicos/uso terapéutico , Sistemas de Liberación de Medicamentos , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Tomografía de Emisión de Positrones , Ultrasonografía , Sistemas de Liberación de Medicamentos/métodos , Sistemas de Liberación de Medicamentos/tendencias , Humanos , Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/tendencias , Ultrasonografía/métodos , Ultrasonografía/tendencias
15.
J Control Release ; 172(3): 812-22, 2013 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-24161382

RESUMEN

Our goal was to develop strategies to quantify the accumulation of model therapeutics in small brain metastases using multimodal imaging, in order to enhance the potential for successful treatment. Human melanoma cells were injected into the left cardiac ventricle of immunodeficient mice. Bioluminescent, MR and PET imaging were applied to evaluate the limits of detection and potential for contrast agent extravasation in small brain metastases. A pharmacokinetic model was applied to estimate vascular permeability. Bioluminescent imaging after injecting d-luciferin (molecular weight (MW) 320 D) suggested that tumor cell extravasation had already occurred at week 1, which was confirmed by histology. 7T T1w MRI at week 4 was able to detect non-leaky 100 µm sized lesions and leaky tumors with diameters down to 200 µm after contrast injection at week 5. PET imaging showed that (18)F-FLT (MW 244 Da) accumulated in the brain at week 4. Gadolinium-based MRI tracers (MW 559 Da and 2.066 kDa) extravasated after 5 weeks (tumor diameter 600 µm), and the lower MW agent cleared more rapidly from the tumor (mean apparent permeabilities 2.27 × 10(-5)cm/s versus 1.12 × 10(-5)cm/s). PET imaging further demonstrated tumor permeability to (64)Cu-BSA (MW 65.55 kDa) at week 6 (tumor diameter 700 µm). In conclusion, high field T1w MRI without contrast may improve the detection limit of small brain metastases, allowing for earlier diagnosis of patients, although the smallest lesions detected with T1w MRI were permeable only to d-luciferin and the amphipathic small molecule (18)F-FLT. Different-sized MR and PET contrast agents demonstrated the gradual increase in leakiness of the blood tumor barrier during metastatic progression, which could guide clinicians in choosing tailored treatment strategies.


Asunto(s)
Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Encéfalo/patología , Melanoma/patología , Melanoma/secundario , Animales , Benzotiazoles , Medios de Contraste , Femenino , Gadolinio , Humanos , Luminiscencia , Imagen por Resonancia Magnética , Ratones , Ratones SCID , Imagen Multimodal , Imagen Óptica , Permeabilidad , Tomografía de Emisión de Positrones
16.
Cancer Res ; 72(6): 1485-93, 2012 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-22282664

RESUMEN

Acquisition of the epithelial-mesenchymal transition (EMT) tumor phenotype is associated with impaired chemotherapeutic delivery and a poor prognosis. In this study, we investigated the application of therapeutic ultrasound methods available in the clinic to increase nanotherapeutic particle accumulation in epithelial and EMT tumors by labeling particles with a positron emission tomography tracer. Epithelial tumors were highly vascularized with tight cell-cell junctions, compared with EMT tumors where cells displayed an irregular, elongated shape with loosened cell-cell adhesions and a reduction in E-cadherin and cytokeratins 8/18 and 19. Without ultrasound, the accumulation of liposomal nanoparticles administered to tumors in vivo was approximately 1.5 times greater in epithelial tumors than EMT tumors. When ultrasound was applied, both nanoaccumulation and apparent tumor permeability were increased in both settings. Notably, ultrasound effects differed with thermal and mechanical indices, such that increasing the thermal ultrasound dose increased nanoaccumulation in EMT tumors. Taken together, our results illustrate how ultrasound can be used to enhance nanoparticle accumulation in tumors by reducing their intratumoral pressure and increasing their vascular permeability.


Asunto(s)
Transición Epitelial-Mesenquimal/efectos de los fármacos , Nanopartículas/administración & dosificación , Neoplasias/tratamiento farmacológico , Sonido , Animales , Cadherinas/análisis , Queratina-18/análisis , Queratina-19/análisis , Queratina-8/análisis , Liposomas/administración & dosificación , Ratones , Tomografía de Emisión de Positrones , Células Tumorales Cultivadas
17.
Artículo en Inglés | MEDLINE | ID: mdl-21859578

RESUMEN

As the applications of ultrasonic thermal therapies expand, the design of the high-intensity array must address both the energy delivery of the main beam and the character and relevance of off-target beam energy. We simulate the acoustic field performance of a selected set of circular arrays organized by array format, including flat versus curved arrays, periodic versus random arrays, and center void diameter variations. Performance metrics are based on the -3-dB focal main lobe (FML) positioning range, axial grating lobe (AGL) temperatures, and side lobe levels. Using finite-element analysis, we evaluate the relative heating of the FML and the AGLs. All arrays have a maximum diameter of 100λ, with element count ranging from 64 to 1024 and continuous wave frequency of 1.5 MHz. First, we show that a 50% spherical annulus produces focus beam side lobes which decay as a function of lateral distance at nearly 87% of the exponential rate of a full aperture. Second, for the arrays studied, the efficiency of power delivery over the -3-dB focus positioning range for spherical arrays is at least 2-fold greater than for flat arrays; the 256-element case shows a 5-fold advantage for the spherical array. Third, AGL heating can be significant as the focal target is moved to its distal half-intensity depth from the natural focus. Increasing the element count of a randomized array to 256 elements decreases the AGL-to-FML heating ratio to 0.12 at the distal half-intensity depth. Further increases in element count yield modest improvements. A 49% improvement in the AGL-to-peak heating ratio is predicted by using the Sumanaweera spiral element pattern with randomization.


Asunto(s)
Terapia por Ultrasonido/instrumentación , Simulación por Computador , Diseño de Equipo , Análisis de Elementos Finitos , Calor
18.
PLoS One ; 6(11): e27372, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22132098

RESUMEN

Therapeutic ultrasound (US) can be noninvasively focused to activate drugs, ablate tumors and deliver drugs beyond the blood brain barrier. However, well-controlled guidance of US therapy requires fusion with a navigational modality, such as magnetic resonance imaging (MRI) or X-ray computed tomography (CT). Here, we developed and validated tissue characterization using a fusion between US and CT. The performance of the CT/US fusion was quantified by the calibration error, target registration error and fiducial registration error. Met-1 tumors in the fat pads of 12 female FVB mice provided a model of developing breast cancer with which to evaluate CT-based tissue segmentation. Hounsfield units (HU) within the tumor and surrounding fat pad were quantified, validated with histology and segmented for parametric analysis (fat: -300 to 0 HU, protein-rich: 1 to 300 HU, and bone: HU>300). Our open source CT/US fusion system differentiated soft tissue, bone and fat with a spatial accuracy of ∼1 mm. Region of interest (ROI) analysis of the tumor and surrounding fat pad using a 1 mm(2) ROI resulted in mean HU of 68±44 within the tumor and -97±52 within the fat pad adjacent to the tumor (p<0.005). The tumor area measured by CT and histology was correlated (r(2) = 0.92), while the area designated as fat decreased with increasing tumor size (r(2) = 0.51). Analysis of CT and histology images of the tumor and surrounding fat pad revealed an average percentage of fat of 65.3% vs. 75.2%, 36.5% vs. 48.4%, and 31.6% vs. 38.5% for tumors <75 mm(3), 75-150 mm(3) and >150 mm(3), respectively. Further, CT mapped bone-soft tissue interfaces near the acoustic beam during real-time imaging. Combined CT/US is a feasible method for guiding interventions by tracking the acoustic focus within a pre-acquired CT image volume and characterizing tissues proximal to and surrounding the acoustic focus.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Tejido Adiposo/diagnóstico por imagen , Animales , Automatización , Calibración , Campos Electromagnéticos , Estudios de Factibilidad , Femenino , Ratones , Neoplasias/patología , Especificidad de Órganos , Ultrasonografía
19.
J Control Release ; 151(1): 28-34, 2011 Apr 10.
Artículo en Inglés | MEDLINE | ID: mdl-21241753

RESUMEN

Changes in lipid acyl chain length can result in desorption of lipid from the liposomal anchorage and interaction with blood components. PET studies of the stability of such lipids have not been performed previously although such studies can map the pharmacokinetics of unstable lipids non-invasively in vivo. The purpose of this study was to characterize the in vivo clearance of (64)Cu-labeled distearoyl- and dipalmitoyl lipid included within long circulating liposomes. Distearoyl and dipalmitoyl maleimide lipids (1mol%) in liposomes were labeled with a (64)Cu-incorporated bifunctional chelator (TETA-PDP) after the activation of pyridine disulfide to thiol by TCEP. Long circulating liposomes containing HSPC:DSPE-PEG2k-OMe:cholesterol: x (55:5:39:1), where x was (64)Cu-DSPE or (64)Cu-DPPE, or HSPC:DSPE-PEG2k-OMe:cholesterol:(64)Cu-DSPE:DPPC (54:5:39:1:1) were evaluated in serum (in vitro) and via intravenous injection to FVB mice. The time-activity curves for the blood, liver, and kidney were measured from PET images and the biodistribution was performed at 48h. In vitro assays showed that (64)Cu-DPPE transferred from liposomes to serum with a 7.9h half-life but (64)Cu-DSPE remained associated with the liposomes. The half clearance of radioactivity from the blood pool was 18 and 5h for (64)Cu-DSPE- and (64)Cu-DPPE liposome-injected mice, respectively. The clearance of radioactivity from the liver and kidney was significantly greater following the injection of (64)Cu-DPPE-labeled liposomes than (64)Cu-DSPE-labeled liposomes at 6, 18 and 28h. Forty eight hours after injection, the whole body radioactivity was 57 and 17% ID/cc for (64)Cu-DSPE and (64)Cu-DPPE, respectively. These findings suggest that the acyl chain length of the radiolabel should be considered for liposomal PET studies and that PET is an effective tool for evaluating the stability of nanoformulations in vivo.


Asunto(s)
Radioisótopos de Cobre/farmacocinética , Liposomas/química , Liposomas/farmacocinética , Fosfatidiletanolaminas/química , Fosfatidiletanolaminas/farmacocinética , Tomografía de Emisión de Positrones , Animales , Radioisótopos de Cobre/química , Femenino , Semivida , Maleimidas/química , Ratones
20.
Clin Cancer Res ; 17(3): 550-9, 2011 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-21106723

RESUMEN

PURPOSE: We apply positron emission tomography (PET) to elucidate changes in nanocarrier extravasation during the transition from premalignant to malignant cancer, providing insight into the use of imaging to characterize early cancerous lesions and the utility of nanoparticles in early disease. EXPERIMENTAL DESIGN: Albumin and liposomes were labeled with (64)Cu (half-life 12.7 hours), and longitudinal PET and CT imaging studies were conducted in a mouse model of ductal carcinoma in situ. A pharmacokinetic model was applied to estimate the tumor vascular volume and permeability. RESULTS: From early time points characterized by disseminated hyperproliferation, the enhanced vascular permeability facilitated lesion detection. During disease progression, the vascular volume fraction increased 1.6-fold and the apparent vascular permeability to albumin and liposomes increased ∼2.5-fold to 6.6 × 10(-8) and 1.3 × 10(-8) cm/s, respectively, with the accumulation of albumin increasing earlier in the disease process. In the malignant tumor, both tracers reached similar mean intratumoral concentrations of ∼6% ID/cc but the distribution of liposomes was more heterogeneous, ranging from 1% to 18% ID/cc compared with 1% to 9% ID/cc for albumin. The tumor-to-muscle ratio was 17.9 ± 8.1 and 7.1 ± 0.5 for liposomes and albumin, respectively, indicating a more specific delivery of liposomes than with albumin. CONCLUSIONS: PET imaging of radiolabeled particles, validated by confocal imaging and histology, detected the transition from premalignant to malignant lesions and effectively quantified the associated changes in vascular permeability.


Asunto(s)
Permeabilidad Capilar , Carcinoma in Situ/irrigación sanguínea , Transformación Celular Neoplásica/metabolismo , Liposomas/metabolismo , Neoplasias Mamarias Experimentales/irrigación sanguínea , Tomografía de Emisión de Positrones/métodos , Animales , Radioisótopos de Cobre , Progresión de la Enfermedad , Ratones , Nanopartículas/análisis , Albúmina Sérica/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA