Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 518
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Am J Gastroenterol ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38976522

RESUMEN

BACKGROUND AIMS: Clinically significant post-endoscopic retrograde cholangiopancreatography (ERCP) bleeding (CSPEB) is common. Contemporary estimates of risk are lacking. We aimed to identify risk factors for and outcomes following CSPEB. METHODS: We analyzed multi-center prospective ERCP data between 2018-2023 with 30-day follow-up. The primary outcome was CSPEB, defined as hematemesis, melena, or hematochezia resulting in: hemoglobin drop ≥20 g/L or transfusion and/or endoscopy to evaluate suspected bleeding, and/or unplanned healthcare visitation and/or prolongation of existing admission. Firth logistic regression was employed. P-values <0.05 were significant, with odds ratios (ORs) and 95% confidence intervals reported. RESULTS: CSPEB occurred following 129 (1.5%) of 8,517 ERCPs (mean onset 3.2 days), with 110 of 4,849 events (2.3%) occurring following higher-risk interventions (sphincterotomy, sphincteroplasty, pre-cut sphincterotomy, and/or needle-knife access). CSPEB patients required endoscopy and transfusion in 86.0% and 53.5% of cases, respectively, with three cases (2.3%) being fatal. P2Y12 inhibitors were held for a median of 4 days (IQR 4) prior to higher-risk ERCP. Following higher-risk interventions, P2Y12 inhibitors (OR 3.33, 1.26-7.74), warfarin (OR 8.54, 3.32-19.81), dabigatran (OR 13.40, 2.06-59.96), rivaroxaban (OR 7.42, 3.43-15.24) and apixaban (OR 4.16, 1.99-8.20) were associated with CSPEB. Significant intraprocedural bleeding post sphincterotomy (OR 2.32, 1.06-4.60), but not post sphincteroplasty, was also associated. Concomitant cardiorespiratory events occurred more frequently within 30 days following CSPEB (OR 12.71, 4.75-32.54). CONCLUSIONS: Risks of antiplatelet-related CSPEB may be underestimated by endoscopists based on observations of suboptimal holding before higher-risk ERCP. Appropriate periprocedural antithrombotic management is essential and could represent novel quality initiative targets.

2.
Pancreatology ; 24(1): 184-187, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38176963

RESUMEN

BACKGROUND/OBJECTIVES: The impact of competency-based training programs on pancreatic endoscopic retrograde cholangiopancreatography (ERCP) performance remains unclear. This study aimed to describe the learning curves of pancreatic ERCP and subsequent performance during independent practice. METHODS: This was a multicenter prospective cohort study involving advanced endoscopy trainees (AETs). In the 1st phase, trainees were assessed on every 5th ERCP using the ERCP and EUS Skills Assessment Tool (TEESAT). Cumulative sum (CUSUM) analysis of pancreatic ERCP evaluations was used to establish learning curves. During the 2nd phase (1st year of independent practice), now-graduated participants documented their performance on key ERCP quality indicators. RESULTS: A total of 24 AETs (20 training programs) received sufficient evaluations for CUSUM analysis. Pancreatic ERCP accounted for 14.6 % (196/1339) of all ERCPs evaluated with 45 % of pancreatic ERCPs carrying a Grade 3 level of complexity. A minority of AETs (16.7 %) performed enough pancreatic ERCPs to generate meaningful learning curves with no AETs achieving competence in pancreatic cannulation, sphincterotomy, or stone clearance during Phase 1. In Phase 2, a total of 3620 ERCPs were performed, of which 281 (7.8 %) were pancreatic ERCPs. While the overall pancreatic duct cannulation rate was 92.2 %, the native papilla pancreatic duct cannulation rate was 85.7 %, which was below the recommended 90 % threshold. CONCLUSIONS: Advanced endoscopy training offers a low level of exposure to pancreatic ERCP, which is mirrored in independent practice, highlighting the inadequate training in pancreatic ERCP. Given the complexity of pancreatic ERCP, novel strategies are warranted to improve training in pancreatic ERCP.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Gastroenterología , Taurina/análogos & derivados , Humanos , Estudios Prospectivos , Gastroenterología/educación , Cateterismo
3.
Gastrointest Endosc ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38639679

RESUMEN

BACKGROUND AND AIMS: The American Society for Gastrointestinal Endoscopy (ASGE) AI Task Force along with experts in endoscopy, technology space, regulatory authorities, and other medical subspecialties initiated a consensus process that analyzed the current literature, highlighted potential areas, and outlined the necessary research in artificial intelligence (AI) to allow a clearer understanding of AI as it pertains to endoscopy currently. METHODS: A modified Delphi process was used to develop these consensus statements. RESULTS: Statement 1: Current advances in AI allow for the development of AI-based algorithms that can be applied to endoscopy to augment endoscopist performance in detection and characterization of endoscopic lesions. Statement 2: Computer vision-based algorithms provide opportunities to redefine quality metrics in endoscopy using AI, which can be standardized and can reduce subjectivity in reporting quality metrics. Natural language processing-based algorithms can help with the data abstraction needed for reporting current quality metrics in GI endoscopy effortlessly. Statement 3: AI technologies can support smart endoscopy suites, which may help optimize workflows in the endoscopy suite, including automated documentation. Statement 4: Using AI and machine learning helps in predictive modeling, diagnosis, and prognostication. High-quality data with multidimensionality are needed for risk prediction, prognostication of specific clinical conditions, and their outcomes when using machine learning methods. Statement 5: Big data and cloud-based tools can help advance clinical research in gastroenterology. Multimodal data are key to understanding the maximal extent of the disease state and unlocking treatment options. Statement 6: Understanding how to evaluate AI algorithms in the gastroenterology literature and clinical trials is important for gastroenterologists, trainees, and researchers, and hence education efforts by GI societies are needed. Statement 7: Several challenges regarding integrating AI solutions into the clinical practice of endoscopy exist, including understanding the role of human-AI interaction. Transparency, interpretability, and explainability of AI algorithms play a key role in their clinical adoption in GI endoscopy. Developing appropriate AI governance, data procurement, and tools needed for the AI lifecycle are critical for the successful implementation of AI into clinical practice. Statement 8: For payment of AI in endoscopy, a thorough evaluation of the potential value proposition for AI systems may help guide purchasing decisions in endoscopy. Reliable cost-effectiveness studies to guide reimbursement are needed. Statement 9: Relevant clinical outcomes and performance metrics for AI in gastroenterology are currently not well defined. To improve the quality and interpretability of research in the field, steps need to be taken to define these evidence standards. Statement 10: A balanced view of AI technologies and active collaboration between the medical technology industry, computer scientists, gastroenterologists, and researchers are critical for the meaningful advancement of AI in gastroenterology. CONCLUSIONS: The consensus process led by the ASGE AI Task Force and experts from various disciplines has shed light on the potential of AI in endoscopy and gastroenterology. AI-based algorithms have shown promise in augmenting endoscopist performance, redefining quality metrics, optimizing workflows, and aiding in predictive modeling and diagnosis. However, challenges remain in evaluating AI algorithms, ensuring transparency and interpretability, addressing governance and data procurement, determining payment models, defining relevant clinical outcomes, and fostering collaboration between stakeholders. Addressing these challenges while maintaining a balanced perspective is crucial for the meaningful advancement of AI in gastroenterology.

4.
Gastrointest Endosc ; 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38935016

RESUMEN

BACKGROUND AND AIMS: Training in interventional endoscopy is offered by nonaccredited advanced endoscopy fellowship programs (AEFPs). The number of these programs has increased dramatically with a concurrent increase in the breadth and complexity of interventional endoscopy procedures. Accreditation is governed by competency-based education, yet what constitutes a "high-quality" nonaccredited AEFP has not been defined. Using an evidence-based consensus process, we aimed to establish standards for AEFPs. METHODS: The RAND UCLA appropriateness method, a well-described modified Delphi process to develop quality indicators, was used. A task force established by the American Society for Gastrointestinal Endoscopy drafted potential quality indicators (structure, process, and outcome) in 6 categories: activity preceding training; structure of AEFPs; training in ERCP, EUS, and EMR; and luminal stent placement. Three rounds of iterative feedback from 20 experts were conducted. Round 0 involved discussion of project details. In round 1, experts independently ranked proposed quality indicators on a 9-point interval scale ranging from highly inappropriate (1) to highly appropriate (9). Next, proposed quality indicators were discussed and reworded in a group meeting followed by round 2, in which experts independently reranked proposed quality indicators and provided benchmarks (when applicable). The median score for each quality indicator was calculated. Mean absolute deviation from the median was calculated, and appropriateness of potential quality indicators was assessed using the BIOMED concerted action on appropriateness definition, P value method, and interpercentile range adjusted for symmetry definition. A quality indicator was deemed appropriate if the median score was ≥7 and met criteria for appropriateness using all 3 defined statistical methods. RESULTS: Of 89 proposed quality indicators, 37 statements met criteria as appropriate for a quality indicator (activity preceding training, 2; structure of AEFPs, 10; training in ERCP, 7; training in EUS, 8; training in EMR, 7; luminal stent placement, 3). Minimum thresholds were defined for 19 relevant quality indicators for number of trainers, procedures during fellowship, and procedures before assessment of competence. Among the final appropriate quality indicators were that all trainees should undergo qualitative and quantitative competence assessments using validated tools at least quarterly with documented feedback throughout the training period and that trainees should track outcomes and relevant quality metrics for specific procedures. CONCLUSIONS: This consensus process using validated methodology established standards for an AEFP in an effort to ensure adequate training in the most commonly taught interventional endoscopic procedures (ERCP, EUS, EMR, and luminal stent placement) during fellowship. An important component of an AEFP is the use of competency-based assessments that are compliant with the Accreditation Council for Graduate Medical Education's Next Accreditation System, with the goal of ensuring that trainees achieve specific milestones in their progression to achieving cognitive and technical competency.

5.
Endoscopy ; 56(6): 421-430, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38224964

RESUMEN

BACKGROUND: Although polyp size dictates surveillance intervals, endoscopists often estimate polyp size inaccurately. We hypothesized that an intervention providing didactic instruction and real-time feedback could significantly improve polyp size classification. METHODS: We conducted a multicenter randomized controlled trial to evaluate the impact of different components of an online educational module on polyp sizing. Participants were randomized to control (no video, no feedback), video only, feedback only, or video + feedback. The primary outcome was accuracy of polyp size classification into clinically relevant categories (diminutive [1-5mm], small [6-9mm], large [≥10mm]). Secondary outcomes included accuracy of exact polyp size (inmm), learning curves, and directionality of inaccuracy (over- vs. underestimation). RESULTS: 36 trainees from five training programs provided 1360 polyp size assessments. The feedback only (80.1%, P=0.01) and video + feedback (78.9%, P=0.02) groups had higher accuracy of polyp size classification compared with controls (71.6%). There was no significant difference in accuracy between the video only group (74.4%) and controls (P=0.42). Groups receiving feedback had higher accuracy of exact polyp size (inmm) and higher peak learning curves. Polyps were more likely to be overestimated than underestimated, and 29.3% of size inaccuracies impacted recommended surveillance intervals. CONCLUSIONS: Our online educational module significantly improved polyp size classification. Real-time feedback appeared to be a critical component in improving accuracy. This scalable and no-cost educational module could significantly decrease under- and overutilization of colonoscopy, improving patient outcomes while increasing colonoscopy access.


Asunto(s)
Competencia Clínica , Pólipos del Colon , Colonoscopía , Humanos , Pólipos del Colon/patología , Pólipos del Colon/diagnóstico , Colonoscopía/educación , Colonoscopía/métodos , Femenino , Masculino , Retroalimentación Formativa , Curva de Aprendizaje , Instrucción por Computador/métodos , Adulto , Persona de Mediana Edad
6.
J Arthroplasty ; 39(8S1): S115-S119, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38401617

RESUMEN

BACKGROUND: Our aim was to study the additive effect of surgeon-administered adductor canal infiltration (SACI) over routine periarticular infiltration (PAI) on pain control [morphine consumption and pain score by the visual analog scale (VAS)] and early function [flexion and Timed Up and Go (TUG) test] post-total knee arthroplasty (TKA). METHODS: We prospectively randomized 60 patients into 2 groups. Group I patients received the standard PAI, whereas in Group II, the patients received a SACI in addition to the PAI. The total volume of the injected drug and the postoperative pain management protocol were the same for all. The number of doses of patient-controlled analgesia (PCA) used for breakthrough pain was recorded as PCA consumption. For early function, flexion and the TUG test were used. The VAS score and PCA consumption were compared between the 2 groups by using analyses of variance with post hoc tests as indicated. The TUG test and flexion were compared using Student t tests. The level of significance was set at 0.05. RESULTS: The PCA consumption in the first 6 hours was significantly higher in Group I (P = .04). The VAS at 6 hours was significantly lower in Group II (P = .042). The TUG test was comparable between the 2 groups preoperatively (P = .72) at 24 hours (P = .60) and 48 hours (P = .60) post-TKA. The flexion was comparable between the 2 groups preoperatively (P = .85) at 24 hours (P = .48) and 48 hours (P = .79) post-TKA. CONCLUSIONS: Adding a SACI to PAI provides improved pain relief and reduces opioid consumption without affecting early function post-TKA. A SACI avoids the need for an anesthesiologist or specialized equipment with no added operating time and minimal added cost. We recommend routine use of SACI for all patients undergoing TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Dimensión del Dolor , Dolor Postoperatorio , Humanos , Dolor Postoperatorio/etiología , Dolor Postoperatorio/prevención & control , Femenino , Masculino , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Analgesia Controlada por el Paciente/métodos , Anestésicos Locales/administración & dosificación , Analgésicos Opioides/administración & dosificación , Manejo del Dolor/métodos , Resultado del Tratamiento , Morfina/administración & dosificación , Inyecciones Intraarticulares , Bloqueo Nervioso/métodos
7.
J Environ Manage ; 356: 120446, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38484595

RESUMEN

There is a serious concern about the large amount of accumulated plastic waste all around the world. Synthetic polymers such as polyethylene terephthalate (PET), polypropylene (PP), and polyethylene (HDPE, LDPE) are substantially present in the plastic waste generated. There are various methods reported to minimise such plastics waste with certain limitations. To overcome such limitations the present study have been carried out in which thermal decomposition of plastic waste of PET, PP, HDPE, and LDPE studied using a novel plasma pyrolysis reactor. The major objective of this work is to investigate the viability of the continuous plasma pyrolysis process for the treatment of various plastic wastes with respect to waste volume reduction and production of combustible hydrogen-rich fuel gas. The effect of temperature and feed flow rate on product gas yield, product gas efficiency, solid residue yield, and H2/CO ratio has been evaluated. The experiments have been carried out at different temperatures within the range of 700-1000 °C. Plasma pyrolysis system exhibited combustible hydrogen-rich gas as a product and solid residue. Liquid products have not been observed during plasma pyrolysis, unlike conventional pyrolysis. The reaction mechanism of plastic cracking has been discussed based on literature and products obtained in the present work. The effects of feed flow rate and temperature on exergy efficiency were studied using the response surface method. The mass, energy, and exergy analyses have also been carried out for all the experiments, which are in the range of 0.95-0.99, 0.48 to 0.77, and 0.30 to 0.69, respectively.


Asunto(s)
Plásticos , Polietileno , Polietileno/química , Plásticos/química , Hidrógeno , Pirólisis , Polipropilenos/química , Tereftalatos Polietilenos
8.
HPB (Oxford) ; 26(5): 656-663, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38383208

RESUMEN

BACKGROUND: Hepatic artery infusion (HAI) is less frequently used in the adjuvant setting for resectable colorectal liver metastasis (CRLM) due to concerns regarding toxicity. Our objective was to evaluate the safety and feasibility of establishing an adjuvant HAI program. METHODS: Patients who underwent HAI pump placement between January 2019 and February 2023 for CRLM were identified. Complications and HAI delivery were compared between patients who received HAI in the unresectable and adjuvant settings. RESULTS: Of 51 patients, 23 received HAI for unresectable CRLM and 28 in the adjuvant setting. Patients with unresectable CRLM more commonly had bilobar disease (n = 23/23 vs n = 18/28, p < 0.01) and more preoperative liver metastases (median 10 [IQR 6-15] vs 4 [IQR 3-7], p < 0.01). Biliary sclerosis was the most common complication (n = 2/23 vs n = 4/28); however, there were no differences in postoperative or HAI-specific complications. In the most recent two years, 0 patients in the unresectable group vs 2 patients in the adjuvant group developed biliary sclerosis. All patients were initiated on HAI with no difference in treatment times or dose reductions. CONCLUSION: Adjuvant HAI is safe and feasible for patients with resectable CRLM. HAI programs can carefully consider including patients with resectable CRLM if managed by an experienced multidisciplinary team with quality assurance controls in place.


Asunto(s)
Neoplasias Colorrectales , Estudios de Factibilidad , Arteria Hepática , Infusiones Intraarteriales , Neoplasias Hepáticas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Neoplasias Hepáticas/secundario , Neoplasias Hepáticas/cirugía , Neoplasias Colorrectales/patología , Estudios Retrospectivos , Quimioterapia Adyuvante , Resultado del Tratamiento
9.
Am J Gastroenterol ; 118(10): 1880-1887, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37307537

RESUMEN

INTRODUCTION: Cold snare polypectomy (CSP) is strongly recommended as the optimal technique for the complete removal of small polyps. Though significant variability in polypectomy technique and quality has been established, the learning curve and impact of targeted training on CSP are unknown. Video feedback has shown promise as an effective pedagogy to improve performance among surgical trainees. We aimed to compare CSP performance between trainees who received video-based feedback and those who received conventional apprentice-based concurrent feedback. We hypothesized that video-based feedback would accelerate competence. METHODS: We conducted a single-blinded, randomized controlled trial on competence for CSP of polyps <1 cm, comparing video-based feedback with conventional feedback. We randomly assigned deidentified consecutively recorded CSP videos to blinded raters to assess using the CSP Assessment Tool. We shared cumulative sum learning curves every 25 CSP with each trainee. The video feedback trainees also received biweekly individualized terminal feedback. Control trainees received conventional feedback during colonoscopy. The primary outcome was CSP competence. We also assessed competence across domains and change over polypectomy volume. RESULTS: We enrolled and randomized 22 trainees, 12 to video-based feedback and 10 to conventional feedback, and evaluated 2,339 CSP. The learning curve was long; 2 trainees (16.7%) in the video feedback achieved competence, after a mean of 135 polyps, and no one in the control ( P = 0.481) achieved competence. Overall and in all steps of CSP, a higher percentage of the video feedback group met competence, increasing 3% every 20 CSP ( P = 0.0004). DISCUSSION: Video feedback aided trainees to competence in CSP. However, the learning curve was long. Our findings strongly suggest that current training methods are not sufficient to support trainees to competency by the completion of their fellowship programs. The impact of new training methods, such as simulation-based mastery learning, should be assessed to determine whether such methods can result in achievement of competence at a faster rate; ClinicalTrials.gov : NCT03115008.


Asunto(s)
Pólipos del Colon , Colonoscopía , Humanos , Colonoscopía/métodos , Pólipos del Colon/cirugía , Microcirugia
10.
Endoscopy ; 55(9): 847-856, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36822219

RESUMEN

BACKGROUND : Assessment of competence in endoscopic retrograde cholangiopancreatography (ERCP) is critical for supporting learning and documenting attainment of skill. Validity evidence supporting ERCP observational assessment tools has not been systematically evaluated. METHODS : We conducted a systematic search using electronic databases and hand-searching from inception until August 2021 for studies evaluating observational assessment tools of ERCP performance. We used a unified validity framework to characterize validity evidence from five sources: content, response process, internal structure, relations to other variables, and consequences. Each domain was assigned a score of 0-3 (maximum score 15). We assessed educational utility and methodological quality using the Accreditation Council for Graduate Medical Education framework and the Medical Education Research Quality Instrument, respectively. RESULTS : From 2769 records, we included 17 studies evaluating 7 assessment tools. Five tools were studied for clinical ERCP, one for simulated ERCP, and one for simulated and clinical ERCP. Validity evidence scores ranged from 2 to 12. The Bethesda ERCP Skills Assessment Tool (BESAT), ERCP Direct Observation of Procedural Skills Tool (ERCP DOPS), and The Endoscopic Ultrasound (EUS) and ERCP Skills Assessment Tool (TEESAT) had the strongest validity evidence, with scores of 10, 12, and 11, respectively. Regarding educational utility, most tools were easy to use and interpret, and required minimal additional resources. Overall methodological quality (maximum score 13.5) was strong, with scores ranging from 10 to 12.5. CONCLUSIONS : The BESAT, ERCP DOPS, and TEESAT had strong validity evidence compared with other assessments. Integrating tools into training may help drive learners' development and support competency decision making.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica , Competencia Clínica , Humanos , Evaluación Educacional/métodos , Educación de Postgrado en Medicina/métodos , Curva de Aprendizaje , Reproducibilidad de los Resultados
11.
J Natl Compr Canc Netw ; 21(4): 393-422, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-37015332

RESUMEN

Cancers originating in the esophagus or esophagogastric junction constitute a major global health problem. Esophageal cancers are histologically classified as squamous cell carcinoma (SCC) or adenocarcinoma, which differ in their etiology, pathology, tumor location, therapeutics, and prognosis. In contrast to esophageal adenocarcinoma, which usually affects the lower esophagus, esophageal SCC is more likely to localize at or higher than the tracheal bifurcation. Systemic therapy can provide palliation, improved survival, and enhanced quality of life in patients with locally advanced or metastatic disease. The implementation of biomarker testing, especially analysis of HER2 status, microsatellite instability status, and the expression of programmed death-ligand 1, has had a significant impact on clinical practice and patient care. Targeted therapies including trastuzumab, nivolumab, ipilimumab, and pembrolizumab have produced encouraging results in clinical trials for the treatment of patients with locally advanced or metastatic disease. Palliative management, which may include systemic therapy, chemoradiation, and/or best supportive care, is recommended for all patients with unresectable or metastatic cancer. Multidisciplinary team management is essential for all patients with locally advanced esophageal or esophagogastric junction cancers. This selection from the NCCN Guidelines for Esophageal and Esophagogastric Junction Cancers focuses on the management of recurrent or metastatic disease.


Asunto(s)
Adenocarcinoma , Carcinoma de Células Escamosas , Neoplasias Esofágicas , Neoplasias Primarias Secundarias , Humanos , Calidad de Vida , Neoplasias Esofágicas/diagnóstico , Neoplasias Esofágicas/genética , Neoplasias Esofágicas/terapia , Adenocarcinoma/diagnóstico , Adenocarcinoma/genética , Adenocarcinoma/terapia , Unión Esofagogástrica/patología , Carcinoma de Células Escamosas/patología , Neoplasias Primarias Secundarias/patología
12.
Pharm Res ; 40(12): 2917-2933, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37468827

RESUMEN

PURPOSE: To investigate the effect of dry coating the amount and type of silica on powder flowability enhancement using a comprehensive set of 19 pharmaceutical powders having different sizes, surface roughness, morphology, and aspect ratios, as well as assess flow predictability via Bond number estimated using a mechanistic multi-asperity particle contact model. METHOD: Particle size, shape, density, surface energy and area, SEM-based morphology, and FFC were assessed for all powders. Hydrophobic (R972P) or hydrophilic (A200) nano-silica were dry coated for each powder at 25%, 50%, and 100% surface area coverage (SAC). Flow predictability was assessed via particle size and Bond number. RESULTS: Nearly maximal flow enhancement, one or more flow category, was observed for all powders at 50% SAC of either type of silica, equivalent to 1 wt% or less for both the hydrophobic R972P or hydrophilic A200, while R972P generally performed slightly better. Silica amount as SAC better helped understand the relative performance. The power-law relation between FFC and Bond number was observed. CONCLUSION: Significant flow enhancements were achieved at 50% SAC, validating previous models. Most uncoated very cohesive powders improved by two flow categories, attaining easy flow. Flowability could not be predicted for both the uncoated and dry coated powders via particle size alone. Prediction was significantly better using Bond number computed via the mechanistic multi-asperity particle contact model accounting for the particle size, surface energy, roughness, and the amount and type of silica. The widely accepted 200 nm surface roughness was not valid for most pharmaceutical powders.


Asunto(s)
Dióxido de Silicio , Dióxido de Silicio/química , Polvos/química , Tamaño de la Partícula , Interacciones Hidrofóbicas e Hidrofílicas , Composición de Medicamentos
13.
Ann Noninvasive Electrocardiol ; 28(1): e13015, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36345173

RESUMEN

INTRODUCTION: QTc prolongation is key in diagnosing long QT syndrome (LQTS), however 25%-50% with congenital LQTS (cLQTS) demonstrate a normal resting QTc. T wave morphology (TWM) can distinguish cLQTS subtypes but its role in acquired LQTS (aLQTS) is unclear. METHODS: Electronic databases were searched using the terms "LQTS," "long QT syndrome," "QTc prolongation," "prolonged QT," and "T wave," "T wave morphology," "T wave pattern," "T wave biomarkers." Whole text articles assessing TWM, independent of QTc, were included. RESULTS: Seventeen studies met criteria. TWM measurements included T-wave amplitude, duration, magnitude, Tpeak-Tend, QTpeak, left and right slope, center of gravity (COG), sigmoidal and polynomial classifiers, repolarizing integral, morphology combination score (MCS) and principal component analysis (PCA); and vectorcardiographic biomarkers. cLQTS were distinguished from controls by sigmoidal and polynomial classifiers, MCS, QTpeak, Tpeak-Tend, left slope; and COG x axis. MCS detected aLQTS more significantly than QTc. Flatness, asymmetry and notching, J-Tpeak; and Tpeak-Tend correlated with QTc in aLQTS. Multichannel block in aLQTS was identified by early repolarization (ERD30% ) and late repolarization (LRD30% ), with ERD reflecting hERG-specific blockade. Cardiac events were predicted in cLQTS by T wave flatness, notching, and inversion in leads II and V5 , left slope in lead V6 ; and COG last 25% in lead I. T wave right slope in lead I and T-roundness achieved this in aLQTS. CONCLUSION: Numerous TWM biomarkers which supplement QTc assessment were identified. Their diagnostic capabilities include differentiation of genotypes, identification of concealed LQTS, differentiating aLQTS from cLQTS; and determining multichannel versus hERG channel blockade.


Asunto(s)
Electrocardiografía , Síndrome de QT Prolongado , Humanos , Síndrome de QT Prolongado/genética , Genotipo , Biomarcadores
14.
Drug Resist Updat ; 63: 100851, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35810716

RESUMEN

Breast cancer is one of the most prevalent cancers in women and a leading cause of mortality. As per the GLOBCAN report of 2021, breast cancer has surpassed lung cancer which until recently was the most commonly diagnosed cancer. Despite significant efforts to improve early detection and therapeutic efficacy of breast cancer, the frequent emergence of drug resistance remains the predominant basis for the poor prognosis of cancer patients harboring various malignancies. Long non-coding RNA (lncRNAs) are known to affect a variety of components of genome function, including epigenetics, gene transcription, splicing, translation, as well as many central biological processes like cell cycle progression, cell differentiation, development, and pluripotency. LncRNAs are dysregulated in various malignancies and interact with a multitude of RNAs and proteins to impact drug resistance. LncRNAs regulate chemoresistance in cancer by employing an assortment of molecular mechanisms including multidrug efflux, suppression of apoptosis, DNA damage response, epigenetic alterations, as well as functioning as competitive endogenous RNA. When combined with other regulatory mechanisms, these pathways form a complex orchestration of signaling that ultimately lead to chemoresistance. The current review delves into the role of lncRNAs in inducing drug resistance to conventional therapeutic anti-cancer drugs used for the treatment of breast cancer. We propose that lncRNAs that provoke drug resistance could be used to develop new targeted and tailored therapeutics providing a novel approach to introduce promising personalized treatment modalities to overcome chemoresistance in breast cancer patients. Hence, lncRNAs that drive anticancer drug resistance can be potentially explored as biomarkers of disease prognosis and may provide unique opportunities to circumvent chemoresistance in breast cancer patients.


Asunto(s)
Antineoplásicos , Neoplasias de la Mama , Neoplasias Pulmonares , ARN Largo no Codificante , Antineoplásicos/farmacología , Antineoplásicos/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/genética , Resistencia a Antineoplásicos/genética , Femenino , Humanos , Neoplasias Pulmonares/tratamiento farmacológico , ARN Largo no Codificante/genética , ARN Largo no Codificante/metabolismo
15.
Chem Biodivers ; 20(11): e202300799, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702285

RESUMEN

Pyrazolic hybrids appended with naphthalene, p-chlorobenzene, o-phenol and toluene have been synthesized using Claisen Schmidt condensation reaction of 1-benzyl-3,5-dimethyl-1H-pyrazole-4-carbaldehyde. All compounds were characterized by various spectroscopic techniques. Compound (E)-3-(1-benzyl-3,5-dimethyl-1H-pyrazol-4-yl)-1-(4-chlorophenyl)prop-2-en-1-one crystallizes in monoclinic crystal system with C2/c space group. These synthesized compounds were tested for cytotoxic activity and among these compounds 4b and 5a shows prominent cytotoxic activity against triple-negative breast cancer (TNBC) cells MDA-MB-231 with IC50 values 47.72 µM and 24.25 µM, respectively. Distinguishing morphological changes were noticed in MDA-MB-231 cells treated with pyrazole hybrids contributing to apoptosis action. To get more insight into cytotoxic activity, in silico molecular docking of these compounds were performed and the results suggested that (E)-3-(1-benzyl-3,5-dimethyl-1H-pyrazol-4-yl)-1-(p-tolyl)prop-2-en-1-one and 1-(1'-benzyl-5-(4-chlorophenyl)-3',5'-dimethyl-3,4-dihydro-1'H,2H-[3,4'-bipyrazol]-2-yl)ethan-1-one binds to the prominent domain of Akt2 indicating their potential ability as Akt2 inhibitor. Moreover, from in silico ADME studies clearly demonstrated that these compounds may be regarded as a drug candidate for sub-lingual absorption based on log p values (2.157-4.924). These compounds also show promising antitubercular activity. The overall results suggest that pyrazolic hybrids with substitution at less sterically hindered positions have appealing potent cytotoxic activity and antituberculosis activity due to which they may act as multidrug candidate.


Asunto(s)
Antineoplásicos , Células MDA-MB-231 , Simulación del Acoplamiento Molecular , Estructura Molecular , Línea Celular Tumoral , Antineoplásicos/farmacología , Antineoplásicos/química , Pirazoles/farmacología , Pirazoles/química , Relación Estructura-Actividad
16.
J Arthroplasty ; 38(6S): S109-S113, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36996948

RESUMEN

BACKGROUND: Anterior knee pain (AKP) and patello-femoral crepitus (PFCr) continue to plague total knee arthroplasty patients despite advances and modifications to implant design and surgical techniques. We present our study of the femoral trochlear length measurement preimplantation and postimplantation and its association with AKP/PFCr and clinical scores. METHODS: Using computer navigation, we obtained several measurements in 263 total knee arthroplasty (posterior-stabilized) patients, which included femoral native trochlear measurement (NTM) and difference in trochlear length between implant and native trochlea. We report their association with Knee Society Score, Western Ontario McMaster University Arthritic Index, and AKP/PFCr at 1 year postoperatively. RESULTS: Mean Knee Society Score and Western Ontario McMaster University Arthritic Index scores were significantly worse in patients who had AKP (P = .005 and P = .002 respectively). Receiver operating characteristic curve showed a statistically significant association between NTM and AKP (Area under the curve = 0.609, P = .014). Lower the NTM, greater was the incidence of AKP. Analysis of the receiver operating characteristic curve identified the cutoff value of NTM to be ≤25.5 with sensitivity of 76.7(95% confidence interval - 57.7 - 90.1) and specificity of 46.9 (95% confidence interval - 41.9 - 55.1). Patients who had NTM of ≤25.5 had an odds ratio of 3.09 to have AKP. The difference in trochlear length ranged from 7.4 to 32.1 millimeters, indicating that postimplantation there was lengthwise overstuffing along the trochlea in every patient. CONCLUSION: We found that the shorter the native femoral trochlea and greater the difference between implanted and native trochlea, the higher was the occurrence of AKP. A mismatch in trochlear measurement preimplantation and postimplantation resulted in lengthwise overstuffing in the anterior knee causing AKP and PFCr.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/efectos adversos , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía , Rodilla/cirugía , Dolor/cirugía , Rótula/cirugía
17.
J Environ Manage ; 344: 118335, 2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37329581

RESUMEN

Energy security and waste management are gaining global attention. The modern world is producing a large amount of liquid and solid waste as a result of the increasing population and industrialization. A circular economy encourages the conversion of waste to energy and other value-added products. Waste processing requires a sustainable route for a healthy society and clean environment. One of the emerging solutions for waste treatment is plasma technology. It converts waste into syngas, oil, and char/slag depending on the thermal/non-thermal processes. Most of all the types of carbonaceous wastes can be treated by plasma processes. The addition of a catalyst to the plasma process is a developing field as plasma processes are energy intensive. This paper covers the detailed concept of plasma and catalysis. It comprises various types of plasma (non-thermal and thermal) and catalysts (zeolites, oxides, and salts) which have been used for waste treatment. Catalyst addition improves gas yield and hydrogen selectivity at moderate temperatures. Depending on the properties of the catalyst and type of plasma, comprehensive points are listed for the selection of the right catalyst for a plasma process. This review offers an in-depth analysis of the research in the field of waste-to-energy using plasma-catalytic processes.


Asunto(s)
Residuos Sólidos , Administración de Residuos , Residuos Sólidos/análisis , Tecnología , Catálisis , Conservación de los Recursos Naturales
18.
AAPS PharmSciTech ; 24(1): 51, 2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36703032

RESUMEN

A highly porous additive, Neusilin®, with high adsorption capability is investigated to improve bulk properties, hence processability of spray-dried amorphous solid dispersions (ASDs). Griseofulvin (GF) is applied as a model BCS class 2 drug in ASDs. Two grades of Neusilin®, US2 (coarser) and UFL2 (finer), were used as additives to produce spray-dried amorphous composite (AC) powders, and their performance was compared with the resulting ASDs without added Neusilin®. The resulting AC powders that included Neusilin® had greatly enhanced flowability (flow function coefficient (FFC) > 10) comparable to larger particles (100 µm) yet had finer particle size (< 50 µm), hence retaining the advantage of fast dissolution rate of finer sizes. Dissolution results demonstrated that achieved GF supersaturation for AC powders with Neusilin® was as high as 3 times that of crystalline GF concentration and was achieved within 30 min. In addition, 80% of drug was released within 4 min. The flowability improvement for AC powders with Neusilin® was more significant as compared to spray-dried ASDs without Neusilin®. Thus, the role of Neusilin® in flowability improvement was evident, considering that spray-dried AC with Neusilin® UFL2 has higher FFC than ASDs having a similar size. Lastly, the AC powders retained a fully amorphous state of GF after 3-month ambient storage. The overall results conveyed that the improved flowability and dissolution rate could outweigh the loss of drug loading resulted by addition of Neusilin®.


Asunto(s)
Solubilidad , Polvos/química , Tamaño de la Partícula
19.
Gastroenterology ; 161(2): 701-711, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34334168

RESUMEN

The purpose of this American Gastroenterological Association Institute Clinical Practice Update was to review the available evidence and provide best practice advice regarding strategies to improve the quality of screening and surveillance colonoscopy. This review is framed around 15 best practice advice statements regarding colonoscopy quality that were agreed upon by the authors, based on a review of the available evidence and published guidelines. This is not a formal systematic review and thus no formal rating of the quality of evidence or strength of recommendation has been carried out.


Asunto(s)
Colonoscopía/normas , Neoplasias Colorrectales/patología , Detección Precoz del Cáncer/normas , Gastroenterología/normas , Mejoramiento de la Calidad/normas , Indicadores de Calidad de la Atención de Salud/normas , Benchmarking , Neoplasias Colorrectales/mortalidad , Neoplasias Colorrectales/terapia , Consenso , Medicina Basada en la Evidencia/normas , Humanos , Valor Predictivo de las Pruebas , Pronóstico , Factores de Tiempo
20.
Am J Pathol ; 191(11): 1888-1905, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34331941

RESUMEN

Alzheimer disease (AD) is the most common cause of dementia. Biological definitions of AD are limited to the cerebral burden of amyloid ß plaques, neurofibrillary pathology, and neurodegeneration. However, current evidence suggests that various features of small vessel disease (SVD) are part of and covertly modify both sporadic and familial AD. Neuroimaging studies suggest that white matter hyperintensities explained by vascular mechanisms occurs frequently in the AD spectrum. Recent advances have further emphasized that frontal periventricular and posterior white matter hyperintensities are associated with cerebral amyloid angiopathy in familial AD. Although whether SVD markers precede the classically recognized biomarkers of disease is debatable, post-mortem studies show that SVD pathology incorporating small cortical and subcortical infarcts, microinfarcts, microbleeds, perivascular spacing, and white matter attenuation is commonly found in sporadic as well as in mutation carriers with confirmed familial AD. Age-related cerebral vessel pathologies such as arteriolosclerosis and cerebral amyloid angiopathy modify progression or worsen risk by shifting the threshold for cognitive impairment and AD dementia. The incorporation of SVD as a biomarker is warranted in the biological definition of AD. Therapeutic interventions directly reducing the burden of brain amyloid ß have had no major impact on the disease or delaying cognitive deterioration, but lowering the risk of vascular disease seems the only rational approach to tackle both early- and late-onset AD dementia.


Asunto(s)
Enfermedad de Alzheimer/patología , Enfermedades de los Pequeños Vasos Cerebrales/patología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA