Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Arch Toxicol ; 97(4): 947-961, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36795116

RESUMEN

Drug-induced testicular injury (DITI) is one of the often-observed and challenging safety issues seen during drug development. Semen analysis and circulating hormones currently utilized have significant gaps in their ability to detect testicular damage accurately. In addition, no biomarkers enable a mechanistic understanding of the damage to the different regions of the testis, such as seminiferous tubules, Sertoli, and Leydig cells. MicroRNAs (miRNAs) are a class of non-coding RNAs that modulate gene expression post-transcriptionally and have been indicated to regulate a wide range of biological pathways. Circulating miRNAs can be measured in the body fluids due to tissue-specific cell injury/damage or toxicant exposure. Therefore, these circulating miRNAs have become attractive and promising non-invasive biomarkers for assessing drug-induced testicular injury, with several reports on their use as safety biomarkers for monitoring testicular damage in preclinical species. Leveraging emerging tools such as 'organs-on-chips' that can emulate the human organ's physiological environment and function is starting to enable biomarker discovery, validation, and clinical translation for regulatory qualification and implementation in drug development.


Asunto(s)
MicroARN Circulante , MicroARNs , Masculino , Humanos , Testículo/metabolismo , MicroARN Circulante/metabolismo , MicroARNs/genética , Biomarcadores/metabolismo , Células Intersticiales del Testículo/metabolismo
2.
Anal Chem ; 92(14): 9745-9754, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32551505

RESUMEN

There is a growing interest in using endogenous compounds as drug transporter biomarkers to facilitate drug-drug interaction (DDI) risk assessment in early phase I clinical trials. Compared to other drug transporters, however, no valid biomarker for hepatic organic cation transporter (OCT) 1 has been described to date. The present work represents the first report of an endogenous compound, isobutyryl-l-carnitine (IBC), as a potential clinical OCT1 biomarker for DDI assessment. A hydrophilic interaction chromatography (HILIC)-mass spectrometry/high resolution mass spectrometry (MS/HRMS) assay with a simple sample preparation method was developed. The assay is capable of simultaneously quantifying multiple endogenous compounds, including IBC, thiamine, N1-methylnicotinamide (1-NMN), creatinine, carnitine, and metformin, which is a probe for OCT1 and OCT2 and MATE1 and MATE2K (multidrug and toxin extrusion proteins) in clinical studies. The HRMS assay was fit-for-purpose validated in human plasma and demonstrated good linearity, accuracy, and precision for all analytes. It was further applied to two phase I clinical trials to evaluate potential biomarkers for OCT1 and additional cation transporters (renal OCT2, MATE1, and MATE2K). The clinical data demonstrated that plasma IBC changes correlated well with in vitro data and supported its use as a liver OCT1 biomarker. The described HILIC-MS/HRMS assay can be used as a "biomarker cocktail" to simultaneously assess clinical DDI risk for the inhibition of OCT1/2 and MATEs in clinical studies with new drug candidates.


Asunto(s)
Biomarcadores/química , Carnitina/análogos & derivados , Inhibidores Enzimáticos/farmacocinética , Transportador 1 de Catión Orgánico/metabolismo , Carnitina/química , Ensayos Clínicos Fase I como Asunto , Interacciones Farmacológicas , Inhibidores Enzimáticos/farmacología , Humanos , Metformina/farmacocinética , Proteínas de Transporte de Catión Orgánico/genética , Proteínas de Transporte de Catión Orgánico/metabolismo , Transportador 1 de Catión Orgánico/antagonistas & inhibidores , Transportador 1 de Catión Orgánico/química , Transportador 2 de Cátion Orgánico/metabolismo
3.
Bioanalysis ; 14(9): 505-580, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35578993

RESUMEN

The 15th edition of the Workshop on Recent Issues in Bioanalysis (15th WRIB) was held on 27 September to 1 October 2021. Even with a last-minute move from in-person to virtual, an overwhelmingly high number of nearly 900 professionals representing pharma and biotech companies, contract research organizations (CROs), and multiple regulatory agencies still eagerly convened to actively discuss the most current topics of interest in bioanalysis. The 15th WRIB included 3 Main Workshops and 7 Specialized Workshops that together spanned 1 week in order to allow exhaustive and thorough coverage of all major issues in bioanalysis, biomarkers, immunogenicity, gene therapy, cell therapy and vaccines. Moreover, in-depth workshops on biomarker assay development and validation (BAV) (focused on clarifying the confusion created by the increased use of the term "Context of Use - COU"); mass spectrometry of proteins (therapeutic, biomarker and transgene); state-of-the-art cytometry innovation and validation; and, critical reagent and positive control generation were the special features of the 15th edition. This 2021 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2021 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1A) covers the recommendations on Endogenous Compounds, Small Molecules, Complex Methods, Regulated Mass Spec of Large Molecules, Small Molecule, PoC. Part 1B covers the Regulatory Agencies' Inputs on Bioanalysis, Biomarkers, Immunogenicity, Gene & Cell Therapy and Vaccine. Part 2 (ISR for Biomarkers, Liquid Biopsies, Spectral Cytometry, Inhalation/Oral & Multispecific Biotherapeutics, Accuracy/LLOQ for Flow Cytometry) and Part 3 (TAb/NAb, Viral Vector CDx, Shedding Assays; CRISPR/Cas9 & CAR-T Immunogenicity; PCR & Vaccine Assay Performance; ADA Assay Comparabil ity & Cut Point Appropriateness) are published in volume 14 of Bioanalysis, issues 10 and 11 (2022), respectively.


Asunto(s)
Vesículas Extracelulares , Vacunas , Biomarcadores/análisis , Tratamiento Basado en Trasplante de Células y Tejidos , Vesículas Extracelulares/química , Humanos , Espectrometría de Masas/métodos , Nanomedicina
4.
Drug Metab Dispos ; 39(1): 30-8, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20926621

RESUMEN

Vorapaxar (SCH 530348), a potent oral thrombin protease-activated receptor 1 antagonist, is being developed as an antiplatelet agent for patients with established vascular disease. The objective of this study was to identify the human liver cytochrome P450 (P450) enzyme(s) responsible for the metabolism of SCH 530348. Human liver microsomes metabolized SCH 530348 to M19, an amine metabolite formed via carbamate cleavage, and M20 (monohydroxy-SCH 530348). Recombinant human CYP3A4 exhibited the most activity (11.5% profiled radioactivity) for the formation of M19, followed by markedly less substrate conversion with CYP1A1 and CYP2C19. Trace levels of M19, a major excreted human metabolite, were detected with CYP1A2, CYP3A5, and CYP4F3A. Formation of M19 by human liver microsomes was inhibited 89% by ketoconazole (IC(50), 0.73 µM), 34% by tranylcypromine, and 89% by anti-CYP3A4 monoclonal antibody. There was a significant correlation between the rate of M19 formation and midazolam 1'-hydroxylation (r = 0.75) or M19 formation and testosterone 6ß-hydroxylation (r = 0.92). The results of screening, inhibition, and correlation studies confirmed that CYP3A4 is the major P450 enzyme responsible for M19 formation from SCH 530348. In contrast, formation of M20, a major circulating human metabolite at steady state, was primarily catalyzed by CYP3A4 and CYP2J2. M20 is pharmacologically equipotent to SCH 530348, whereas M19 is an inactive metabolite. Formation of M20 by human liver microsomes was inhibited 89% by ketoconazole, 75% by astemizole (a CYP2J2 inhibitor), and 43% by CYP3A4 monoclonal antibody. These results suggest that CYP3A4 and CYP2J2 are both involved in the formation of M20 metabolite.


Asunto(s)
Citocromo P-450 CYP3A/metabolismo , Sistema Enzimático del Citocromo P-450/metabolismo , Lactonas/metabolismo , Piridinas/metabolismo , Receptor PAR-1/antagonistas & inhibidores , Receptores de Trombina/antagonistas & inhibidores , Astemizol/farmacología , Sistema Enzimático del Citocromo P-450/fisiología , Humanos , Hidroxilación , Cetoconazol/farmacología , Lactonas/sangre , Lactonas/farmacocinética , Lactonas/farmacología , Microsomas/metabolismo , Microsomas Hepáticos/metabolismo , Piridinas/sangre , Piridinas/farmacocinética , Piridinas/farmacología , Receptor PAR-1/metabolismo , Proteínas Recombinantes/metabolismo , Tranilcipromina/farmacología
5.
Drug Metab Dispos ; 39(1): 123-31, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20876787

RESUMEN

Muraglitazar and peliglitazar, two structural analogs differing by a methyl group, are dual peroxisome proliferator-activated receptor-α/γ activators. Both compounds were extensively metabolized in humans through acyl glucuronidation to form 1-O-ß-acyl glucuronide (AG) metabolites as the major drug-related components in bile, representing at least 15 to 16% of the dose after oral administration. Peliglitazar AG was the major circulating metabolite, whereas muraglitazar AG was a very minor circulating metabolite in humans. Peliglitazar AG circulated at lower concentrations in animal species than in humans. Both compounds had a similar glucuronidation rate in UDP-glucuronic acid-fortified human liver microsomal incubations and a similar metabolism rate in human hepatocytes. Muraglitazar AG and peliglitazar AG were chemically synthesized and found to be similarly oxidized through hydroxylation and O-demethylation in NADPH-fortified human liver microsomal incubations. Peliglitazar AG had a greater stability than muraglitazar AG in incubations in buffer, rat, or human plasma (pH 7.4). Incubations of muraglitazar AG or peliglitazar AG in plasma produced more aglycon than acyl migration products compared with incubations in the buffer. These data suggested that the difference in plasma stability, not differences in intrinsic formation, direct excretion, or further oxidation of muraglitazar AG or peliglitazar AG, contributed to the observed difference in the circulation of these AG metabolites in humans. The study demonstrated the difficulty in doing risk assessment based on metabolite exposure in plasma because the more reactive muraglitazar AG would not have triggered a threshold of concern based on the recent U.S. Food and Drug Administration guidance on Metabolites in Safety Testing, whereas the more stable peliglitazar AG would have.


Asunto(s)
Glucurónidos/sangre , Glicina/análogos & derivados , Oxazoles/metabolismo , Adulto , Animales , Bilis/química , Bilis/metabolismo , Estabilidad de Medicamentos , Glucurónidos/metabolismo , Glicina/sangre , Glicina/química , Glicina/metabolismo , Glicina/farmacología , Hepatocitos/metabolismo , Humanos , Macaca fascicularis , Masculino , Ratones , Microsomas Hepáticos/metabolismo , Oxazoles/sangre , Oxazoles/química , Oxazoles/farmacología , Oxidación-Reducción , PPAR alfa/agonistas , PPAR alfa/metabolismo , PPAR gamma/agonistas , PPAR gamma/metabolismo , Ratas , Medición de Riesgo , Uridina Difosfato Ácido Glucurónico/metabolismo , Adulto Joven
6.
Clin Pharmacol Ther ; 109(3): 646-657, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32961594

RESUMEN

The aim of this study was to investigate the sensitivity and specificity of endogenous glycochenodeoxycholate and glycodeoxycholate 3-O-glucuronides (GCDCA-3G and GDCA-3G) as substrates for organic anion transporting polypeptide 1B1 (OATP1B1) in humans. We measured fasting levels of plasma GCDCA-3G and GDCA-3G using liquid chromatography-tandem mass spectrometry in 356 healthy volunteers. The mean plasma levels of both compounds were ~ 50% lower in women than in men (P = 2.25 × 10-18 and P = 4.73 × 10-9 ). In a microarray-based genome-wide association study, the SLCO1B1 rs4149056 (c.521T>C, p.Val174Ala) variation showed the strongest association with the plasma GCDCA-3G (P = 3.09 × 10-30 ) and GDCA-3G (P = 1.60 × 10-17 ) concentrations. The mean plasma concentration of GCDCA-3G was 9.2-fold (P = 8.77 × 10-31 ) and that of GDCA-3G was 6.4-fold (P = 2.45x10-13 ) higher in individuals with the SLCO1B1 c.521C/C genotype than in those with the c.521T/T genotype. No other variants showed independent genome-wide significant associations with GCDCA-3G or GDCA-3G. GCDCA-3G was highly efficacious in detecting the SLCO1B1 c.521C/C genotype with an area under the receiver operating characteristic curve of 0.996 (P < 0.0001). The sensitivity (98-99%) and specificity (100%) peaked at a cutoff value of 180 ng/mL for men and 90 ng/mL for women. In a haplotype-based analysis, SLCO1B1*5 and *15 were associated with reduced, and SLCO1B1*1B, *14, and *35 with increased OATP1B1 function. In vitro, both GCDCA-3G and GDCA-3G showed at least 6 times higher uptake by OATP1B1 than OATP1B3 or OATP2B1. These data indicate that the hepatic uptake of GCDCA-3G and GDCA-3G is predominantly mediated by OATP1B1. GCDCA-3G, in particular, is a highly sensitive and specific OATP1B1 biomarker in humans.


Asunto(s)
Glucurónidos/metabolismo , Ácido Glicoquenodesoxicólico/metabolismo , Transportador 1 de Anión Orgánico Específico del Hígado/metabolismo , Hígado/metabolismo , Adulto , Biomarcadores/metabolismo , Cromatografía Liquida , Femenino , Estudio de Asociación del Genoma Completo , Genotipo , Glucurónidos/sangre , Ácido Glicoquenodesoxicólico/sangre , Células HEK293 , Voluntarios Sanos , Humanos , Transportador 1 de Anión Orgánico Específico del Hígado/deficiencia , Transportador 1 de Anión Orgánico Específico del Hígado/genética , Masculino , Fase II de la Desintoxicación Metabólica , Análisis de Secuencia por Matrices de Oligonucleótidos , Variantes Farmacogenómicas , Fenotipo , Polimorfismo de Nucleótido Simple , Espectrometría de Masas en Tándem , Adulto Joven
7.
Clin Pharmacol Ther ; 109(2): 507-516, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32866300

RESUMEN

Endogenous biomarkers are emerging to advance clinical drug-drug interaction (DDI) risk assessment in drug development. Twelve healthy subjects received a multidrug and toxin exclusion protein (MATE) inhibitor (pyrimethamine, 10, 25, and 75 mg) in a crossover fashion to identify an appropriate endogenous biomarker to assess MATE1/2-K-mediated DDI in the kidneys. Metformin (500 mg) was also given as reference probe drug for MATE1/2-K. In addition to the previously reported endogenous biomarker candidates (creatinine and N1 -methylnicotinamide (1-NMN)), N1 -methyladenosine (m1 A) was included as novel biomarkers. 1-NMN and m1 A presented as superior MATE1/2-K biomarkers since changes in their renal clearance (CLr ) along with pyrimethamine dose were well-correlated with metformin CLr changes. The CLr of creatinine was reduced by pyrimethamine, however, its changes poorly correlated with metformin CLr changes. Nonlinear regression analysis (CLr vs. mean total concentration of pyrimethamine in plasma) yielded an estimate of the inhibition constant (Ki ) of pyrimethamine and the fraction of the clearance pathway sensitive to pyrimethamine. The in vivo Ki value thus obtained was further converted to unbound Ki using plasma unbound fraction of pyrimethamine, which was comparable to the in vitro Ki for MATE1 (1-NMN) and MATE2-K (1-NMN and m1 A). It is concluded that 1-NMN and m1 A CLr can be leveraged as quantitative MATE1/2-K biomarkers for DDI risk assessment in healthy volunteers.


Asunto(s)
Biomarcadores/metabolismo , Interacciones Farmacológicas/fisiología , Proteínas de Transporte de Catión Orgánico/metabolismo , Adulto , Pueblo Asiatico , Línea Celular , Creatinina/metabolismo , Estudios Cruzados , Células HEK293 , Voluntarios Sanos , Humanos , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/sangre , Hipoglucemiantes/metabolismo , Riñón/metabolismo , Masculino , Metformina/uso terapéutico , Pirimetamina/administración & dosificación , Pirimetamina/sangre , Pirimetamina/metabolismo , Medición de Riesgo , Adulto Joven
8.
Bioanalysis ; 12(1): 23-34, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31849261

RESUMEN

Aim: Microflow tandem mass spectrometry-based methods have been proposed as options to improve sensitivity and selectivity while improving sample utility and solvent consumption. Here, we evaluate a newly introduced microflow source, OptiFlow™, for quantitative performance. Results/methodology: We performed a comparison of the OptiFlow and IonDrive™ sources, respectively, on the same triple quadrupole mass spectrometer. The comparison used a neat cocktail of commercially available drugs and extracted plasma samples monitoring midazolam and alprazolam metabolites. Microflow produced a 2-4× signal increase for the neat drug cocktail and a 5-10× increase for extracted plasma samples. Conclusion: The OptiFlow method consistently gave increased signal response relative to the IonDrive method and enabled a better lower limit of quantitation for defining phamacokinetics.


Asunto(s)
Preparaciones Farmacéuticas/sangre , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión , Semivida , Humanos , Límite de Detección , Metoprolol/sangre , Metoprolol/metabolismo , Metoprolol/farmacocinética , Oxazolidinonas/sangre , Oxazolidinonas/metabolismo , Oxazolidinonas/farmacocinética , Preparaciones Farmacéuticas/metabolismo , Triptaminas/sangre , Triptaminas/metabolismo , Triptaminas/farmacocinética
9.
Clin Pharmacol Ther ; 107(4): 1004-1013, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31628668

RESUMEN

To address the most appropriate endogenous biomarker for drug-drug interaction risk assessment, eight healthy subjects received an organic anion transporting polypeptide 1B (OATP1B) inhibitor (rifampicin, 150, 300, and 600 mg), and a probe drug cocktail (atorvastatin, pitavastatin, rosuvastatin, and valsartan). In addition to coproporphyrin I, a widely studied OATP1B biomarker, we identified at least 4 out of 28 compounds (direct bilirubin, glycochenodeoxycholate-3-glucuronide, glycochenodeoxycholate-3-sulfate, and hexadecanedioate) that presented good sensitivity and dynamic range in terms of the rifampicin dose-dependent change in area under the plasma concentration-time curve ratio (AUCR). Their suitability as OATP1B biomarkers was also supported by the good correlation of AUC0-24h between the endogenous compounds and the probe drugs, and by nonlinear regression analysis (AUCR-1 vs. rifampicin plasma Cmax (maximum total concentration in plasma)) to yield an estimate of the inhibition constant of rifampicin. These endogenous substrates can complement existing OATP1B-mediated drug-drug interaction risk assessment approaches based on agency guidelines in early clinical trials.


Asunto(s)
Interacciones Farmacológicas/fisiología , Transportador 1 de Anión Orgánico Específico del Hígado/sangre , Rifampin/administración & dosificación , Rifampin/sangre , Adulto , Antibióticos Antituberculosos/administración & dosificación , Antibióticos Antituberculosos/sangre , Biomarcadores/sangre , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Evaluación de Medicamentos , Voluntarios Sanos , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/administración & dosificación , Inhibidores de Hidroximetilglutaril-CoA Reductasas/sangre , Masculino
10.
Bioanalysis ; 11(22): 2029-2048, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31808716

RESUMEN

The 2019 13th Workshop on Recent Issues in Bioanalysis (WRIB) took place in New Orleans, LA, USA on April 1-5, 2019 with an attendance of over 1000 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, week-long event - a full immersion week of bioanalysis, biomarkers, immunogenicity and gene therapy. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule bioanalysis involving LCMS, hybrid LBA/LCMS, LBA cell-based/flow cytometry assays and qPCR approaches. This 2019 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2019 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations on Innovation in Small Molecules and Oligonucleotides & Mass Spec Method Development Strategies for Large Molecules Bioanalysis. Part 2 (2018 FDA BMV Guidance, 2019 ICH M10 BMV Draft Guideline and regulatory agencies' input on bioanalysis, biomarkers, immunogenicity and gene therapy) and Part 3 (New Insights in Biomarkers Assays Validation, Current & Effective Strategies for Critical Reagent Management, Flow Cytometry Validation in drug discovery & development & CLSI H62, Interpretation of the 2019 FDA Immunogenicity Guidance and The Gene Therapy Bioanalytical Challenges) are published in volume 11 of Bioanalysis, issues 23 and 24 (2019), respectively.


Asunto(s)
Cromatografía Liquida/métodos , Invenciones , Espectrometría de Masas/métodos , Oligonucleótidos/análisis , Bibliotecas de Moléculas Pequeñas/análisis
11.
Bioanalysis ; 10(9): 659-671, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29749249

RESUMEN

AIM: Evaluation of HPLC-high-resolution mass spectrometry (HPLC-HRMS) full scan with polarity switching for increasing throughput of human in vitro cocktail drug-drug interaction assay. MATERIALS & METHODS: Microsomal incubates were analyzed using a high resolution and high mass accuracy Q-Exactive mass spectrometer to collect integrated qualitative and quantitative (qual/quant) data. RESULTS: Within assay, positive-to-negative polarity switching HPLC-HRMS method allowed quantification of eight and two probe compounds in the positive and negative ionization modes, respectively, while monitoring for LOR and its metabolites. CONCLUSION: LOR-inhibited CYP2C19 and showed higher activity for CYP2D6, CYP2E1 and CYP3A4. Overall, LC-HRMS-based nontargeted full scan quantitation allowed to improve the throughput of the in vitro cocktail drug-drug interaction assay.


Asunto(s)
Inhibidores Enzimáticos del Citocromo P-450/administración & dosificación , Sistema Enzimático del Citocromo P-450/metabolismo , Ensayos Analíticos de Alto Rendimiento/métodos , Loratadina/administración & dosificación , Microsomas Hepáticos/efectos de los fármacos , Administración Oral , Cromatografía Líquida de Alta Presión/métodos , Exactitud de los Datos , Evaluación Preclínica de Medicamentos , Interacciones Farmacológicas , Humanos , Espectrometría de Masas/métodos , Microsomas Hepáticos/enzimología , Estándares de Referencia
12.
Bioanalysis ; 10(9): 645-657, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29749252

RESUMEN

AIM: Selected bile acids (BAs) in plasma have been proposed as endogenous probes for assessing drug-drug interactions involving hepatic drug transporters such as the organic anion-transporting polypeptides (OATP1B1 and OATP1B3). MATERIALS & METHODS: Plasma extracts were analyzed for selected BAs using a triple TOF API6600 high-resolution mass spectrometer. RESULTS: Glycodeoxycholic acid 3-sulfate, glycochenodeoxycholic acid 3-sulfate, glycodeoxycholic acid 3-O-ß-glucuronide and glycochenodeoxycholic acid 3-O-ß-glucuronide are presented as potential OATP1B1/3 biomarkers. CONCLUSION: Six BAs are quantified in human plasma using a multiplexed high-resolution mass spectrometry method. Glycodeoxycholic acid 3-sulfate and glycodeoxycholic acid 3-O-ß-glucuronide are proposed as potential biomarkers based on observed four- to fivefold increase in plasma AUC (vs placebo), following administration of a compound known to present as an OATP1B1/3 inhibitor in vitro.


Asunto(s)
Biomarcadores Farmacológicos/sangre , Ácido Glicodesoxicólico/sangre , Transportador 1 de Anión Orgánico Específico del Hígado/metabolismo , Miembro 1B3 de la Familia de los Transportadores de Solutos de Aniones Orgánicos/metabolismo , Área Bajo la Curva , Cromatografía Liquida , Interacciones Farmacológicas , Femenino , Ácido Glicodesoxicólico/análogos & derivados , Humanos , Masculino , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/metabolismo , Sensibilidad y Especificidad
13.
Bioanalysis ; 10(9): 673-689, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29749253

RESUMEN

BACKGROUND: N1-methylnicotinamide (1-NMN) has been proposed as a potential clinical biomarker to assess drug-drug interactions involving organic cation transporters (OCT2) and multidrug and toxin extrusion protein transporters. RESULTS: A hydrophilic interaction liquid chromatography-MS/MS assay, to quantify 1-NMN, in human plasma and urine is reported. MATERIALS & METHODS: A hydrophilic interaction chromatography (HILIC)-tandem mass spectrometry (MS/MS) assay to quantify 1-NMN in human plasma and urine is reported. The basal 1-NMN levels in plasma and urine were 4-120 and 2000-15,000 ng/ml, respectively. CONCLUSION: 1-NMN plasma AUCs increased two- to fourfold versus placebo following the administration of a clinical candidate that in vitro experiments indicated was an OCT2 inhibitor. The described hydrophilic interaction liquid chromatography-MS/MS assay can be used to assess a clinical compound candidate for the inhibition of OCT2 and multidrug and toxin extrusion protein transporter in first-in-human studies.


Asunto(s)
Biomarcadores Farmacológicos/análisis , Riñón/metabolismo , Niacinamida/análogos & derivados , Transportador 2 de Cátion Orgánico/metabolismo , Área Bajo la Curva , Biomarcadores Farmacológicos/sangre , Biomarcadores Farmacológicos/orina , Cromatografía Liquida/métodos , Exactitud de los Datos , Interacciones Farmacológicas , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Niacinamida/análisis , Niacinamida/sangre , Niacinamida/orina , Transportador 2 de Cátion Orgánico/antagonistas & inhibidores , Placebos , Estándares de Referencia , Espectrometría de Masas en Tándem/métodos
14.
Bioanalysis ; 10(9): 691-701, 2018 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-29747517

RESUMEN

AIM: A validated LC-MS/MS assay for the quantitation of coproporphyrin-I and -III (CP-I, CP-III) in human plasma has been developed to understand the utility of both as possible endogenous biomarkers for organic anion-transporting polypeptides (OATP)-mediated drug-drug interactions (DDIs). MATERIALS AND METHODS:  Human plasma extracts were analyzed for CP-I and CP-III using a Sciex API 6500+ mass spectrometer. Results: The assay was utilized for plasma samples from a clinical DDI study involving a new chemical entity that presented as an OATP inhibitor in vitro. A formal DDI study, with a probe drug (atorvastatin), was also included as part of the clinical study. CONCLUSION: Changes in CP-I area under the plasma concentration versus time curve (AUC0-48 h) were observed, which were similar to the AUC ratio obtained with atorvastatin. These results support the idea that plasma CP-I may have utility in Phase I by supporting the rapid assessment of OATP inhibition risk.


Asunto(s)
Biomarcadores Farmacológicos/metabolismo , Coproporfirinas/sangre , Transportadores de Anión Orgánico/metabolismo , Área Bajo la Curva , Atorvastatina/metabolismo , Atorvastatina/farmacología , Cromatografía Liquida , Coproporfirinas/química , Interacciones Farmacológicas , Humanos , Transportadores de Anión Orgánico/antagonistas & inhibidores , Estándares de Referencia , Espectrometría de Masas en Tándem
15.
Bioanalysis ; 10(22): 1781-1801, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30488725

RESUMEN

The 2018 12th Workshop on Recent Issues in Bioanalysis (12th WRIB) took place in Philadelphia, PA, USA on April 9-13, 2018 with an attendance of over 900 representatives from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day full immersion in bioanalysis, biomarkers and immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small- and large-molecule bioanalysis involving LC-MS, hybrid ligand binding assay (LBA)/LC-MS and LBA/cell-based assays approaches. This 2018 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2018 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for LC-MS for small molecules, peptides, oligonucleotides and small molecule biomarkers. Part 2 (hybrid LBA/LC-MS for biotherapeutics and regulatory agencies' inputs) and Part 3 (large molecule bioanalysis, biomarkers and immunogenicity using LBA and cell-based assays) are published in volume 10 of Bioanalysis, issues 23 and 24 (2018), respectively.


Asunto(s)
Biomarcadores/análisis , Oligonucleótidos/análisis , Péptidos/análisis , Animales , Cromatografía Liquida , Humanos , Espectrometría de Masas , Philadelphia
16.
J Am Soc Mass Spectrom ; 18(10): 1891-9, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17766144

RESUMEN

The widely different LC-MS response observed for many structurally different compounds limits the use of LC-MS in full scan detection mode for quantitative determination of drugs and metabolites without using reference standard. The recently introduced nanospray ionization (NSI) technique shows comparable MS response for some compounds under non-LC-MS conditions. However, in the presence of numerous endogenous compounds commonly associated with biological samples such as urine, plasma, and bile, LC-MS is required to separate, detect, identify, and measure individual analytes. An LC-NSI-MS system was devised and the MS response obtained in this system for a variety of pharmaceutical drugs and their metabolites. The set-up involves two high-performance liquid chromatography (HPLC) systems, a chip-based NSI source and a quadrupole-time-of-flight (Q-TOF) mass spectrometer. Herein this is referred to as the response normalized-liquid chromatography NSI-MS (RNLC-NSI-MS) system. One HPLC unit performs the analytical separation, while the other unit adds solvent post-column with an exact reverse of the mobile phase composition such that the final composition entering the NSI source is isocratic throughout the entire HPLC run. The data obtained from four different structural classes of compounds [vicriviroc (VCV), desloratadine (DL), tolbutamide, and cocaine] and their metabolites indicate that by maintaining the solvent composition unchanged across the HPLC run, the influence of the solvent environment on the ionization efficiency is minimized. In comparison to responses obtained from radiochromatograms, responses from conventional LC-ESI-MS overestimated the VCV and DL responses, respectively, by 6- and 20-fold. Although VCV and DL responses obtained using LC-NSI-MS are within 2- to 6-fold from the respective radiochromatographic responses, the response normalization modification results in nearly uniform LC-NSI-MS response for all compounds evaluated.


Asunto(s)
Algoritmos , Cromatografía Líquida de Alta Presión/métodos , Microquímica/métodos , Nanotecnología/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Urinálisis/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Bioanalysis ; 9(22): 1787-1806, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28978230

RESUMEN

AIM: Coproporphyrin-I (CP-I) and coproporphyrin-III (CP-III) in plasma and urine have been proposed as biomarkers for assessing drug-drug interactions involving hepatic drug transporters such as organic anion-transporting peptides (OATP), 1B1 and 1B3. Materials & methods: Plasma and urine extracts were analyzed for CP-I/CP-III using a TripleTOF API6600 mass spectrometer. Results: Previously unreported, CP-I/CP-III doubly charged ions (m/z 328.14) were used as precursor ions to improve the assay sensitivity and selectivity over the singly charged precursor ions (m/z 655.28). Levels of CP-I and CP-III measured ranged 0.45-1.1 and 0.050-0.50 ng/ml in plasma and 5-35 and 1-35 ng/ml in urine, respectively. CONCLUSION: The described highly selective and sensitive CP-I/CP-III LC-HRMS assay offers options for earlier characterization and clinical safety projections for OATP1B1/3-mediated drug-drug interactions along with pharmacokinetic analyses of a new chemical entity as part of first-in-human clinical studies.


Asunto(s)
Biomarcadores/análisis , Cromatografía Líquida de Alta Presión/métodos , Coproporfirinas/análisis , Espectrometría de Masas en Tándem/métodos , Biomarcadores/sangre , Biomarcadores/orina , Coproporfirinas/sangre , Coproporfirinas/orina , Interacciones Farmacológicas , Humanos , Extracción Líquido-Líquido , Transportadores de Anión Orgánico Sodio-Independiente/metabolismo , Reproducibilidad de los Resultados
18.
Bioanalysis ; 9(22): 1807-1825, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29148835

RESUMEN

The 2017 11th Workshop on Recent Issues in Bioanalysis (11th WRIB) took place in Los Angeles/Universal City, California from 3 April 2017 to 7 April 2017 with participation of close to 750 professionals from pharmaceutical/biopharmaceutical companies, biotechnology companies, contract research organizations and regulatory agencies worldwide. WRIB was once again a 5-day, weeklong event - A Full Immersion Week of Bioanalysis, Biomarkers and Immunogenicity. As usual, it was specifically designed to facilitate sharing, reviewing, discussing and agreeing on approaches to address the most current issues of interest including both small and large molecule analysis involving LCMS, hybrid LBA/LCMS and ligand-binding assay (LBA) approaches. This 2017 White Paper encompasses recommendations emerging from the extensive discussions held during the workshop, and is aimed to provide the bioanalytical community with key information and practical solutions on topics and issues addressed, in an effort to enable advances in scientific excellence, improved quality and better regulatory compliance. Due to its length, the 2017 edition of this comprehensive White Paper has been divided into three parts for editorial reasons. This publication (Part 1) covers the recommendations for Small Molecules, Peptides and Small Molecule Biomarkers using LCMS. Part 2 (Biotherapeutics, Biomarkers and Immunogenicity Assays using Hybrid LBA/LCMS and Regulatory Agencies' Inputs) and Part 3 (LBA: Immunogenicity, Biomarkers and PK Assays) are published in volume 9 of Bioanalysis, issues 23 and 24 (2017), respectively.


Asunto(s)
Biomarcadores/análisis , Cromatografía Líquida de Alta Presión , Espectrometría de Masas , Péptidos/análisis , Bibliotecas de Moléculas Pequeñas/análisis , Conferencias de Consenso como Asunto , Guías como Asunto , Ligandos , Bibliotecas de Moléculas Pequeñas/química
19.
Bioanalysis ; 8(16): 1645-62, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27460981

RESUMEN

BACKGROUND: Loratadine (LOR, Claritin(®)) is a long-acting antihistamine used to treat allergic rhinitis. The major active human metabolite, desloratadine (DL, Clarinex(®)), is extensively metabolized to 3-hydroxydesloratadine (3-OH-DL) (M40) and subsequently glucuronidated before elimination. This study revealed the ability of a novel, long-term hepatocyte micropatterned co-culture (MPCC) model to generate in vivo metabolites. Metabolites were detected and characterized using non-targeted MS/MS(ALL) with SWATH™ acquisition by a UHPLC-Q-TOF system. Results & methodology: Human MPCCs extensively metabolized LOR and formed 3-OH-DL-glucuronide (M13). Cross-species comparisons revealed monkey- and rat-specific metabolites with gender-specific DL-pyridine-N-oxide formation in male rats. These results demonstrate a first for an in vitro hepatocyte model to generate circulating metabolites of LOR and detect species-specific differences. Early focus on human metabolites could have spared characterization of nonhuman metabolites in preclinical species.


Asunto(s)
Glucurónidos/metabolismo , Hepatocitos/metabolismo , Antagonistas de los Receptores Histamínicos H1 no Sedantes/metabolismo , Loratadina/análogos & derivados , Loratadina/metabolismo , Espectrometría de Masas en Tándem/métodos , Animales , Línea Celular , Cromatografía Líquida de Alta Presión/métodos , Técnicas de Cocultivo/métodos , Femenino , Haplorrinos , Humanos , Masculino , Redes y Vías Metabólicas , Ratas , Especificidad de la Especie
20.
Bioanalysis ; 8(16): 1663-78, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27487385

RESUMEN

AIM: The application of high-resolution MS to antibody-drug conjugate (ADC) drug development may provide insight into their safety and efficacy. Quantification of unconjugated cytotoxic drug (payload) and characterization of drug-to-antibody ratio distribution were determined in plasma using orthogonal acceleration quadrupole-time-of-flight MS. RESULTS: Unconjugated payload quantification determined by quadrupole-time-of-flight-based MRM(highresolution) and triple quadrupole-based multiple reaction monitoring were comparable and achieved detection limits of 0.030 and 0.015 ng/ml, respectively. As determined by immunocapture and TOF-MS, drug-to-antibody ratio remained unchanged up to 3-weeks postdose for an ADC containing engineered glutamine linkers, but declined from four to three over 2 weeks in an ADC containing engineered cysteine linkers. CONCLUSION: The use of high-resolution MS in ADC drug discovery confirms its utility within the bioanalytical discipline.


Asunto(s)
Inmunoconjugados/sangre , Espectrometría de Masas/métodos , Preparaciones Farmacéuticas/sangre , Animales , Cromatografía Líquida de Alta Presión/métodos , Inmunoconjugados/análisis , Límite de Detección , Macaca fascicularis , Preparaciones Farmacéuticas/análisis , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA