Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38938169

RESUMEN

AIMS: Subclinical atrial fibrillation (AF) is associated with increased risk of progression to clinical AF, stroke, and cardiovascular death. We hypothesized that in pacemaker patients requiring dual-chamber rate-adaptive (DDDR) pacing, closed loop stimulation (CLS) integrated into the circulatory control system through intra-cardiac impedance monitoring would reduce the occurrence of atrial high-rate episodes (AHREs) compared with conventional DDDR pacing. METHODS AND RESULTS: Patients with sinus node dysfunctions (SNDs) and an implanted pacemaker or defibrillator were randomly allocated to dual-chamber CLS (n = 612) or accelerometer-based DDDR pacing (n = 598) and followed for 3 years. The primary endpoint was time to the composite endpoint of the first AHRE lasting ≥6 min, stroke, or transient ischaemic attack (TIA). All AHREs were independently adjudicated using intra-cardiac electrograms. The incidence of the primary endpoint was lower in the CLS arm (50.6%) than in the DDDR arm (55.7%), primarily due to the reduction in AHREs lasting between 6 h and 7 days. Unadjusted site-stratified hazard ratio (HR) for CLS vs. DDDR was 0.84 [95% confidence interval (CI), 0.72-0.99; P = 0.035]. After adjusting for CHA2DS2-VASc score, the HR remained 0.84 (95% CI, 0.71-0.99; P = 0.033). In subgroup analyses of AHRE incidence, the incremental benefit of CLS was greatest in patients without atrioventricular block (HR, 0.77; P = 0.008) and in patients without AF history (HR, 0.73; P = 0.009). The contribution of stroke/TIA to the primary endpoint (1.3%) was low and not statistically different between study arms. CONCLUSION: Dual-chamber CLS in patients with SND is associated with a significantly lower AHRE incidence than conventional DDDR pacing.


Asunto(s)
Fibrilación Atrial , Estimulación Cardíaca Artificial , Frecuencia Cardíaca , Ataque Isquémico Transitorio , Marcapaso Artificial , Síndrome del Seno Enfermo , Accidente Cerebrovascular , Humanos , Femenino , Masculino , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/epidemiología , Anciano , Síndrome del Seno Enfermo/terapia , Síndrome del Seno Enfermo/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ataque Isquémico Transitorio/prevención & control , Ataque Isquémico Transitorio/epidemiología , Persona de Mediana Edad , Accidente Cerebrovascular/prevención & control , Accidente Cerebrovascular/epidemiología , Incidencia , Resultado del Tratamiento , Factores de Tiempo , Factores de Riesgo , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas , Acelerometría , Anciano de 80 o más Años
2.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37656991

RESUMEN

AIMS: The HeartLogic Index combines data from multiple implantable cardioverter defibrillators (ICDs) sensors and has been shown to accurately stratify patients at risk of heart failure (HF) events. We evaluated and compared the performance of this algorithm during sinus rhythm and during long-lasting atrial fibrillation (AF). METHODS AND RESULTS: HeartLogic was activated in 568 ICD patients from 26 centres. We found periods of ≥30 consecutive days with an atrial high-rate episode (AHRE) burden <1 h/day and periods with an AHRE burden ≥20 h/day. We then identified patients who met both criteria during the follow-up (AHRE group, n = 53), to allow pairwise comparison of periods. For control purposes, we identified patients with an AHRE burden <1 h throughout their follow-up and implemented 2:1 propensity score matching vs. the AHRE group (matched non-AHRE group, n = 106). In the AHRE group, the rate of alerts was 1.2 [95% confidence interval (CI): 1.0-1.5]/patient-year during periods with an AHRE burden <1 h/day and 2.0 (95% CI: 1.5-2.6)/patient-year during periods with an AHRE-burden ≥20 h/day (P = 0.004). The rate of HF hospitalizations was 0.34 (95% CI: 0.15-0.69)/patient-year during IN-alert periods and 0.06 (95% CI: 0.02-0.14)/patient-year during OUT-of-alert periods (P < 0.001). The IN/OUT-of-alert state incidence rate ratio of HF hospitalizations was 8.59 (95% CI: 1.67-55.31) during periods with an AHRE burden <1 h/day and 2.70 (95% CI: 1.01-28.33) during periods with an AHRE burden ≥20 h/day. In the matched non-AHRE group, the rate of HF hospitalizations was 0.29 (95% CI: 0.12-0.60)/patient-year during IN-alert periods and 0.04 (95% CI: 0.02-0.08)/patient-year during OUT-of-alert periods (P < 0.001). The incidence rate ratio was 7.11 (95% CI: 2.19-22.44). CONCLUSION: Patients received more alerts during periods of AF. The ability of the algorithm to identify increased risk of HF events was confirmed during AF, despite a lower IN/OUT-of-alert incidence rate ratio in comparison with non-AF periods and non-AF patients. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Algoritmos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia
3.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37724686

RESUMEN

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Asunto(s)
Cardiomiopatía Hipertrófica , Desfibriladores Implantables , Humanos , Cardiomiopatía Hipertrófica/complicaciones , Cardiomiopatía Hipertrófica/terapia , Bradicardia , Progresión de la Enfermedad , Adenosina Trifosfato
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37536671

RESUMEN

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Cardiomiopatías , Canalopatías , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Canalopatías/complicaciones , Canalopatías/terapia , Resultado del Tratamiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Sistema de Registros
5.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
6.
Europace ; 24(2): 234-244, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34392336

RESUMEN

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico
7.
Eur Heart J ; 42(5): 508-516, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33279955

RESUMEN

AIM: The benefit of cardiac pacing in patients with severe recurrent reflex syncope and asystole induced by tilt testing has not been established. The usefulness of tilt-table test to select candidates for cardiac pacing is controversial. METHODS AND RESULTS: We randomly assigned patients aged 40 years or older who had at least two episodes of unpredictable severe reflex syncope during the last year and a tilt-induced syncope with an asystolic pause longer than 3 s, to receive either an active (pacing ON; 63 patients) or an inactive (pacing OFF; 64 patients) dual-chamber pacemaker with closed loop stimulation (CLS). The primary endpoint was the time to first recurrence of syncope. Patients and independent outcome assessors were blinded to the assigned treatment. After a median follow-up of 11.2 months, syncope occurred in significantly fewer patients in the pacing group than in the control group [10 (16%) vs. 34 (53%); hazard ratio, 0.23; P = 0.00005]. The estimated syncope recurrence rate at 1 year was 19% (pacing) and 53% (control) and at 2 years, 22% (pacing) and 68% (control). A combined endpoint of syncope or presyncope occurred in significantly fewer patients in the pacing group [23 (37%) vs. 40 (63%); hazard ratio, 0.44; P = 0.002]. Minor device-related adverse events were reported in five patients (4%). CONCLUSION: In patients aged 40 years or older, affected by severe recurrent reflex syncope and tilt-induced asystole, dual-chamber pacemaker with CLS is highly effective in reducing the recurrences of syncope. Our findings support the inclusion of tilt testing as a useful method to select candidates for cardiac pacing. STUDY REGISTRATION: ClinicalTrials.gov identifier NCT02324920, Eudamed number CIV-05-013546.


Asunto(s)
Estimulación Cardíaca Artificial , Paro Cardíaco , Adulto , Paro Cardíaco/etiología , Paro Cardíaco/terapia , Humanos , Reflejo , Síncope/etiología , Síncope/terapia , Pruebas de Mesa Inclinada , Resultado del Tratamiento
8.
Int J Mol Sci ; 23(7)2022 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-35409368

RESUMEN

The medical community recognizes sex-related differences in pathophysiology and cardiovascular disease outcomes (CVD), culminating with heart failure. In general, pre-menopausal women tend to have a better prognosis than men. Explaining why this occurs is not a simple matter. For decades, sex hormones like estrogens (Es) have been identified as one of the leading factors driving these sex differences. Indeed, Es seem protective in women as their decline, during and after menopause, coincides with an increased CV risk and HF development. However, clinical trials demonstrated that E replacement in post-menopause women results in adverse cardiac events and increased risk of breast cancer. Thus, a deeper understanding of E-related mechanisms is needed to provide a vital gateway toward better CVD prevention and treatment in women. Of note, sphingolipids (SLs) and their metabolism are strictly related to E activities. Among the SLs, ceramide and sphingosine 1-phosphate play essential roles in mammalian physiology, particularly in the CV system, and appear differently modulated in males and females. In keeping with this view, here we explore the most recent experimental and clinical observations about the role of E and SL metabolism, emphasizing how these factors impact the CV system.


Asunto(s)
Enfermedades Cardiovasculares , Animales , Enfermedades Cardiovasculares/etiología , Ceramidas/metabolismo , Estrógenos/uso terapéutico , Femenino , Humanos , Lisofosfolípidos , Masculino , Mamíferos/metabolismo , Caracteres Sexuales , Esfingolípidos/metabolismo , Esfingosina/análogos & derivados , Esfingosina/metabolismo
9.
J Cardiovasc Electrophysiol ; 32(9): 2528-2535, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34252991

RESUMEN

INTRODUCTION: Factors influencing malignant arrhythmia onset are not fully understood. We explored the circadian periodicity of ventricular arrhythmias (VAs) in patients with implantable cardioverter and cardiac resynchronization defibrillators (ICD/CRT-D). METHODS: Time, morphology (monomorphic/polymorphic), and mode of termination (anti-tachycardia pacing [ATP] or shock) of VAs stored in a database of remote monitoring data were adjudicated. Episodes were grouped in six 4-h timeslots from 00:00 to 24:00. Circadian distributions and adjusted marginal odds ratios (ORs), with 95% confidence interval (CI), were analyzed using mixed-effect models and logit generalized estimating equations, respectively, to account for within-subject correlation of multiple episodes. RESULTS: Among 1303 VA episodes from 446 patients (63% ICD and 37% CRT-D), 120 (9%) self-extinguished, and 842 (65%) were terminated by ATP, 343 (26%) by shock. VAs clustered from 08:00 to 16:00 with 44% of episodes, as compared with 22% from 00:00 to 08:00 (p < .001) and 34% from 16:00 to 24:00 (p = .005). Episodes were more likely to be polymorphic at night with an adjusted marginal OR of 1.66 (CI, 1.15-2.40; p = .007) at 00:00-04:00 versus other timeslots. Episodes were less likely to be terminated by ATP in the 00:00-04:00 (success-to-failure ratio, 0.67; CI, 0.46-0.98; p = .039) and 08:00-12:00 (0.70; CI, 0.51-0.96; p = .02) timeslots, and most likely to be terminated by ATP between 12:00 and 16:00 (success-to-failure ratio 1.42; CI, 1.06-1.91; p = .02). CONCLUSION: VAs did not distribute uniformly over the 24 h, with a majority of episodes occurring from 08:00 to 16:00. Nocturnal episodes were more likely to be polymorphic. The efficacy of ATP depended on the time of delivery.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Arritmias Cardíacas , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado del Tratamiento
10.
Pacing Clin Electrophysiol ; 44(6): 995-1003, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33908052

RESUMEN

BACKGROUND: During the COVID-19 pandemic in-person visits for patients with cardiac implantable electronic devices should be replaced by remote monitoring (RM), in order to prevent viral transmission. A direct home-delivery service of the RM communicator has been implemented at 49 Italian arrhythmia centers. METHODS: According to individual patient preference or the organizational decision of the center, patients were assigned to the home-delivery group or the standard in-clinic delivery group. In the former case, patients received telephone training on the activation process and use of the communicator. In June 2020, the centers were asked to reply to an ad hoc questionnaire to describe and evaluate their experience in the previous 3 months. RESULTS: RM was activated in 1324 patients: 821 (62%) received the communicator at home and the communicator was activated remotely. Activation required one additional call in 49% of cases, and the median time needed to complete the activation process was 15 min [25th-75th percentile: 10-20]. 753 (92%) patients were able to complete the correct activation of the system. At the time when the questionnaire was completed, 743 (90%) communicators were regularly transmitting data. The service was generally deemed useful (96% of respondents) in facilitating the activation of RM during the COVID-19 pandemic and possibly beyond. CONCLUSIONS: Home delivery of the communicator proved to be a successful approach to system activation, and received positive feedback from clinicians. The increased use of a RM protocol will reduce risks for both providers and patients, while maintaining high-quality care.


Asunto(s)
Arritmias Cardíacas/terapia , COVID-19/epidemiología , Desfibriladores Implantables , Servicios de Atención de Salud a Domicilio , Distanciamiento Físico , Neumonía Viral/epidemiología , Tecnología de Sensores Remotos/instrumentación , Femenino , Humanos , Incidencia , Italia , Masculino , Marcapaso Artificial , Pandemias , Neumonía Viral/virología , SARS-CoV-2
11.
Int J Mol Sci ; 22(4)2021 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-33671974

RESUMEN

G protein-coupled receptors (GPCRs) are the largest family of cell-surface receptors and they are responsible for the transduction of extracellular signals, regulating almost all aspects of mammalian physiology. These receptors are specifically regulated by a family of serine/threonine kinases, called GPCR kinases (GRKs). Given the biological role of GPCRs, it is not surprising that GRKs are also involved in several pathophysiological processes. Particular importance is emerging for GRK5, which is a multifunctional protein, expressed in different cell types, and it has been found located in single or multiple subcellular compartments. For instance, when anchored to the plasma membrane, GRK5 exerts its canonical function, regulating GPCRs. However, under certain conditions (e.g., pro-hypertrophic stimuli), GRK5 translocates to the nucleus of cells where it can interact with non-GPCR-related proteins as well as DNA itself to promote "non-canonical" signaling, including gene transcription. Importantly, due to these actions, several studies have demonstrated that GRK5 has a pivotal role in the pathogenesis of chronic-degenerative disorders. This is true in the cardiac cells, tumor cells, and neurons. For this reason, in this review article, we will inform the readers of the most recent evidence that supports the importance of targeting GRK5 to prevent the development or progression of cancer, cardiovascular, and neurological diseases.


Asunto(s)
Enfermedades Cardiovasculares/tratamiento farmacológico , Enfermedades Cardiovasculares/metabolismo , Quinasa 5 del Receptor Acoplado a Proteína-G/antagonistas & inhibidores , Quinasa 5 del Receptor Acoplado a Proteína-G/metabolismo , Terapia Molecular Dirigida/métodos , Neoplasias/tratamiento farmacológico , Neoplasias/metabolismo , Enfermedades Neurodegenerativas/tratamiento farmacológico , Enfermedades Neurodegenerativas/metabolismo , Animales , Quinasa 5 del Receptor Acoplado a Proteína-G/química , Humanos , Receptores Acoplados a Proteínas G/metabolismo , Transducción de Señal
12.
Europace ; 19(11): 1826-1832, 2017 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-28011803

RESUMEN

AIMS: A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. METHODS AND RESULTS: The survey 'S-ICD Why Not?' was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. CONCLUSION: The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies.


Asunto(s)
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Canalopatías , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Secundaria/instrumentación , Adulto , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/genética , Terapia de Resincronización Cardíaca/efectos adversos , Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/etiología , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Femenino , Encuestas de Atención de la Salud , Humanos , Italia , Masculino , Persona de Mediana Edad , Selección de Paciente , Factores de Riesgo , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 40(7): 850-856, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28543265

RESUMEN

BACKGROUND: Cardiac resynchronization therapy (CRT) has proved to be effective in patients with heart failure and left bundle branch block (LBBB). Recently, new electrocardiography criteria have been proposed for the diagnosis of LBBB. These criteria are stricter than the current American Heart Association (AHA) criteria. We assessed the rate of echocardiographic response to CRT in patients with traditional LBBB versus patients who met the new criteria (strict LBBB). METHODS: Consecutive patients undergoing CRT were enrolled in the CRT MORE registry. Patients with no-LBBB QRS morphology according to AHA criteria, atrial fibrillation, right bundle branch block, and right ventricular pacing were excluded. Strict LBBB was defined as: QRS ≥ 140 ms for men and ≥130 ms for women, QS or rS in V1-V2, mid-QRS notching or slurring in ≥2 contiguous leads. Patients showing a relative decrease of ≥15% in left ventricular end-systolic volume (LVESV) at 12 months were defined as responders. RESULTS: Among 335 patients with LBBB, 131 (39%) had strict LBBB. Patients with and without strict LBBB showed comparable baseline characteristics, except for QRS duration (166 ± 20 ms vs 152 ± 25 ms, P < 0.001). On 12-month evaluation, 205 patients (61%) were responders; 85 of 131 (65%) had strict LBBB and 120 of 204 (59%) had traditional LBBB (P = 0.267). On multivariate analysis, a history of atrial fibrillation, larger LVESV, and the presence of mid-QRS notching in ≥1 lead (odds ratio 2.099; 95% confidence interval 1.061-4.152, P = 0.033) were independently associated with echocardiographic response. CONCLUSION: Stricter definition of LBBB did not improve response to CRT in comparison to the current AHA definition.


Asunto(s)
Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía , Anciano , Ecocardiografía , Femenino , Humanos , Masculino , Sistema de Registros , Resultado del Tratamiento
14.
BMC Cardiovasc Disord ; 16(1): 230, 2016 11 21.
Artículo en Inglés | MEDLINE | ID: mdl-27871237

RESUMEN

BACKGROUND: Arrhythmogenic right ventricular dysplasia (ARVD), is a genetic disorder of the heart, which mainly involves the right ventricle. It is characterized by hypokinetic areas at the free wall of the right ventricle (RV) or both ventricles, where myocardium is replaced by fibrous or fatty tissue. ARVD is an important cause of ventricular arrhythmias in children and young adults. Although the transmission of the disease is based on hereditary, in young adults it may not show any symptoms. The main differential diagnoses with other frequent etiological causes of sudden arrhythmia are: idiopathic outflow tract ventricular tachycardia of the RV, myocarditis, dilated cardiomyopathy and sarcoidosis. CASE PRESENTATION: We describe an unusual case of a 44-year-old woman who was hospitalized for ventricular tachycardia, deep asthenia and dyspnoea with no previous history of cardiac disease. The patient had a ten-year history of palpitations, which started immediately after her last pregnancy. She was diagnosed with both acute/subacute viral myocarditis and arrhythmogenic right ventricular dysplasia, based on established clinical and cardiac MRI criteria. After the diagnosis the patient received an automatic implantable cardioverter defibrillator. Currently, she is on clinical follow-up with no apparent further complications. CONCLUSION: Analyzing this rare case, we have shown the link between myocarditis and arrhythmogenic right ventricular dysplasia, and how important is to perform a cardiac MRI, in the context of acute myocarditis and ventricular arrhythmia.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica/diagnóstico , Imagen por Resonancia Cinemagnética/métodos , Miocarditis/diagnóstico , Miocardio/patología , Enfermedad Aguda , Adulto , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/terapia , Desfibriladores Implantables , Diagnóstico Diferencial , Electrocardiografía , Femenino , Humanos , Miocarditis/complicaciones , Miocarditis/terapia
15.
Circulation ; 128(15): 1612-22, 2013 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-23969695

RESUMEN

BACKGROUND: The sphingosine-1-phosphate receptor 1 (S1PR1) and ß1-adrenergic receptor (ß1AR) are G-protein-coupled receptors expressed in the heart. These 2 receptors have opposing actions on adenylyl cyclase because of differential G-protein coupling. Importantly, both of these receptors can be regulated by the actions of G-protein-coupled receptor kinase-2, which triggers desensitization and downregulation processes. Although classic signaling paradigms suggest that simultaneous activation of ß1ARs and S1PR1s in a myocyte would simply result in opposing action on cAMP production, in this report we have uncovered a direct interaction between these 2 receptors, with regulatory involvement of G-protein-coupled receptor kinase-2. METHODS AND RESULTS: In HEK (human embryonic kidney) 293 cells overexpressing both ß1AR and S1PR1, we demonstrated that ß1AR downregulation can occur after stimulation with sphingosine-1-phosphate (an S1PR1 agonist), whereas S1PR1 downregulation can be triggered by isoproterenol (a ß-adrenergic receptor agonist) treatment. This cross talk between these 2 distinct G-protein-coupled receptors appears to have physiological significance, because they interact and show reciprocal regulation in mouse hearts undergoing chronic ß-adrenergic receptor stimulation and in a rat model of postischemic heart failure. CONCLUSIONS: We demonstrate that restoration of cardiac plasma membrane levels of S1PR1 produces beneficial effects that counterbalance the deleterious ß1AR overstimulation in heart failure.


Asunto(s)
Terapia Genética/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Receptores Adrenérgicos beta 1/genética , Receptores de Lisoesfingolípidos/genética , Animales , Cardiomegalia/fisiopatología , Cardiomegalia/terapia , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Regulación hacia Abajo/fisiología , Proteínas Fluorescentes Verdes/genética , Células HEK293 , Humanos , Masculino , Ratones , Ratones Endogámicos C57BL , Mioblastos Cardíacos/citología , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/terapia , Ratas , Ratas Endogámicas WKY , Receptor Cross-Talk/fisiología , Receptores Adrenérgicos beta 1/metabolismo , Receptores de Lisoesfingolípidos/metabolismo , Receptores de Esfingosina-1-Fosfato
16.
Exp Gerontol ; 190: 112420, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38588751

RESUMEN

Sex differences are consistently identified in determining the prevalence, manifestation, and response to therapies in several systemic disorders, including those affecting the cardiovascular (CV), skeletal muscle, and nervous system. Interestingly, such differences are often more noticeable as we age. For example, premenopausal women experience a lower risk of CV disease than men of the same age. While at an advanced age, with menopause, the risk of cardiovascular diseases and adverse outcomes increases exponentially in women, exceeding that of men. However, this effect appears to be reversed in diseases such as pulmonary hypertension, where women are up to seven times more likely than men to develop an idiopathic form of the disease with symptoms developing ten years earlier than their male counterparts. Explaining this is a complex question. However, several factors and mechanisms have been identified in recent decades, including a role for sex hormones, particularly estrogens and their related receptors. Furthermore, an emerging role in these sex differences has also been suggested for ß-adrenergic receptors (ßARs), which are essential regulators of mammalian physiology. It has in fact been shown that ßARs interact with estrogen receptors (ER), providing further demonstration of their involvement in determining sexual differences. Based on these premises, this review article focused on the ß3AR subtype, which shows important activities in adipose tissue but with new and interesting roles in regulating the function of cardiomyocytes and vascular cells. In detail, we examined how ß3AR and ER signaling are intertwined and whether there would be sex- and age-dependent specific effects of these receptor systems.


Asunto(s)
Envejecimiento , Enfermedades Cardiovasculares , Estrógenos , Receptores Adrenérgicos beta 3 , Receptores de Estrógenos , Humanos , Enfermedades Cardiovasculares/metabolismo , Enfermedades Cardiovasculares/fisiopatología , Femenino , Masculino , Receptores Adrenérgicos beta 3/metabolismo , Estrógenos/metabolismo , Receptores de Estrógenos/metabolismo , Envejecimiento/fisiología , Animales , Factores Sexuales , Sistema Cardiovascular/metabolismo , Sistema Cardiovascular/fisiopatología , Caracteres Sexuales , Transducción de Señal
17.
Am J Cardiol ; 215: 42-49, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38237796

RESUMEN

Invasive hemodynamic studies have shown improved left ventricular (LV) performances when cardiac resynchronization therapy/defibrillator is delivered through multipoint pacing (MPP). Nowadays, strategies have become available that allow studying the same hemodynamic parameters at a noninvasive level. The aim of the present study was to evaluate the clinical implication of using a patient-tailored approach for cardiac resynchronization therapy programming based on noninvasively assessed LV hemodynamics to identify the best biventricular pacing modality between standard single-site pacing (STD) and MPP for each patient. Therefore, 51 patients with heart failure (age 69 ± 9 years, 35 men, 27% ischemic etiology) implanted with cardiac resynchronization therapy/defibrillator underwent noninvasive LV function assessment through photoplethysmography before hospital discharge for addressing dP/dt and stroke volume in both pacing modalities (STD and MPP). The modality that performed better in terms of hemodynamic improvement was permanently programmed. Global longitudinal strain (GLS) was also assessed, and repeated at 3 months. Compared with intrinsic rhythm (928 ± 486 mm Hg/s), dP/dtmax showed a trend to increase in both biventricular pacing modes (1,000 ± 577 mm Hg/s in STD, 1,036 ± 530 mm Hg/s in MPP, p = NS). MPP was associated with a wider hemodynamic improvement than was STD and was the modality of choice in 34 of 51 patients (67%). GLS at predischarge did not differ between groups (-10.3 ± 3.8% vs -10.2 ± 3.5%), but significant improvement of ejection fraction at 1 month (34.4 ± 5.3%, p <0.001) and of GLS at 3 months (-12.9 ± 2.9%, p <0.005) was observed across the entire cohort. At 3 months, 77% of patients were classified as responders. Interestingly, long-term (3 years) follow-up unveiled a reduction in all-cause mortality in the MPP group compared with the STD group. In conclusion, cardiac resynchronization therapy programming guided by acute noninvasive hemodynamics favored MPP modality and caused short-term LV positive remodeling and improved long-term outcomes. Clinical Trial Registration: URL: http://www.clinicaltrials.gov. Unique identifier: NCT04299360.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Masculino , Humanos , Persona de Mediana Edad , Anciano , Hemodinámica , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos , Alta del Paciente , Remodelación Ventricular
18.
Cardiovasc Digit Health J ; 5(3): 164-172, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38989039

RESUMEN

Background: Achieving a high biventricular pacing percentage (BiV%) is crucial for optimizing outcomes in cardiac resynchronization therapy (CRT). The HeartLogic index, a multiparametric heart failure (HF) risk score, incorporates implantable cardioverter-defibrillator (ICD)-measured variables and has demonstrated its predictive ability for impending HF decompensation. Objective: This study aimed to investigate the relationship between daily BiV% in CRT ICD patients and their HF status, assessed using the HeartLogic algorithm. Methods: The HeartLogic algorithm was activated in 306 patients across 26 centers, with a median follow-up of 26 months (25th-75th percentile: 15-37). Results: During the follow-up period, 619 HeartLogic alerts were recorded in 186 patients. Overall, daily values associated with the best clinical status (highest first heart sound, intrathoracic impedance, patient activity; lowest combined index, third heart sound, respiration rate, night heart rate) were associated with a BiV% exceeding 99%. We identified 455 instances of BiV% dropping below 98% after consistent pacing periods. Longer episodes of reduced BiV% (hazard ratio: 2.68; 95% CI: 1.02-9.72; P = .045) and lower BiV% (hazard ratio: 3.97; 95% CI: 1.74-9.06; P=.001) were linked to a higher risk of HeartLogic alerts. BiV% drops exceeding 7 days predicted alerts with 90% sensitivity (95% CI [74%-98%]) and 55% specificity (95% CI [51%-60%]), while BiV% ≤96% predicted alerts with 74% sensitivity (95% CI [55%-88%]) and 81% specificity (95% CI [77%-85%]). Conclusion: A clear correlation was observed between reduced daily BiV% and worsening clinical conditions, as indicated by the HeartLogic index. Importantly, even minor reductions in pacing percentage and duration were associated with an increased risk of HF alerts.

20.
J Cardiovasc Med (Hagerstown) ; 24(7): 430-440, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37222631

RESUMEN

AIM: Atrial fibrillation is a multifaceted disease requiring personalized treatment, in accordance with current ESC guidelines. Despite a wide range of literature, we still have various aspects dividing the opinion of the experts in rate control, rhythm control and thromboembolic prophylaxis. The aim of this survey was to provide a country-wide picture of current practice regarding atrial fibrillation pharmacological management according to a patient's characteristics. METHODS: Data were collected using an in-person survey that was administered to members of the Italian Association of Arrhythmology and Cardiac Pacing. RESULTS: We collected data from 106 physicians, working in 72 Italian hospitals from 15 of 21 regions. Our work evidenced a high inhomogeneity in atrial fibrillation management regarding rhythm control, rate control and thromboembolic prophylaxis in both acute and chronic patients. This element was more pronounced in settings in which literature shows a lack of evidence and, consequently, the indications provided by the guidelines are weak or absent. CONCLUSION: This National survey evidenced a high inhomogeneity in current approaches adopted for atrial fibrillation management by a sample of Italian cardiologist experts in arrhythmia management. Further studies are needed to explore if these divergences are associated with different long-term outcomes.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Encuestas y Cuestionarios , Italia/epidemiología , Sistema de Registros , Antiarrítmicos/uso terapéutico
SELECCIÓN DE REFERENCIAS