Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 98
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 25(2): 546-553, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36106562

RESUMEN

AIMS: Electromechanical coupling in patients receiving cardiac resynchronization therapy (CRT) is not fully understood. Our aim was to determine the best combination of electrical and mechanical substrates associated with effective CRT. METHODS AND RESULTS: Sixty-two patients were prospectively enrolled from two centres. Patients underwent 12-lead electrocardiogram (ECG), cardiovascular magnetic resonance (CMR), echocardiography, and anatomo-electromechanical mapping (AEMM). Remodelling was measured as the end-systolic volume (ΔESV) decrease at 6 months. CRT was defined effective with ΔESV ≤ -15%. QRS duration (QRSd) was measured from ECG. Area strain was obtained from AEMM and used to derive systolic stretch index (SSI) and total left-ventricular mechanical time. Total left-ventricular activation time (TLVAT) and transeptal time (TST) were derived from AEMM and ECG. Scar was measured from CMR. Significant correlations were observed between ΔESV and TST [rho = 0.42; responder: 50 (20-58) vs. non-responder: 33 (8-44) ms], TLVAT [-0.68; 81 (73-97) vs. 112 (96-127) ms], scar [-0.27; 0.0 (0.0-1.2) vs. 8.7 (0.0-19.1)%], and SSI [0.41; 10.7 (7.1-16.8) vs. 4.2 (2.9-5.5)], but not QRSd [-0.13; 155 (140-176) vs. 167 (155-177) ms]. TLVAT and SSI were highly accurate in identifying CRT response [area under the curve (AUC) > 0.80], followed by scar (AUC > 0.70). Total left-ventricular activation time (odds ratio = 0.91), scar (0.94), and SSI (1.29) were independent factors associated with effective CRT. Subjects with SSI >7.9% and TLVAT <91 ms all responded to CRT with a median ΔESV ≈ -50%, while low SSI and prolonged TLVAT were more common in non-responders (ΔESV ≈ -5%). CONCLUSION: Electromechanical measurements are better associated with CRT response than conventional ECG variables. The absence of scar combined with high SSI and low TLVAT ensures effectiveness of CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Función Ventricular Izquierda/fisiología , Cicatriz , Bloqueo de Rama , Ecocardiografía , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
2.
Europace ; 25(2): 643-650, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36352534

RESUMEN

AIMS: To investigate the role of genetic testing in patients with idiopathic atrioventricular conduction disease requiring pacemaker (PM) implantation before the age of 50 years. METHODS AND RESULTS: All consecutive PM implantations in Southern Switzerland between 2010 and 2019 were evaluated. Inclusion criteria were: (i) age at the time of PM implantation: < 50 years; (ii) atrioventricular block (AVB) of unknown aetiology. Study population was investigated by ajmaline challenge and echocardiographic assessment over time. Genetic testing was performed using next-generation sequencing panel, containing 174 genes associated to inherited cardiac diseases, and Sanger sequencing confirmation of suspected variants with clinical implication. Of 2510 patients who underwent PM implantation, 15 (0.6%) were young adults (median age: 44 years, male predominance) presenting with advanced AVB of unknown origin. The average incidence of idiopathic AVB computed over the 2010-2019 time window was 0.7 per 100 000 persons per year (95% CI 0.4-1.2). Most of patients (67%) presented with specific genetic findings (pathogenic variant) or variants of uncertain significance (VUS). A pathogenic variant of PKP2 gene was found in one patient (6.7%) with no overt structural cardiac abnormalities. A VUS of TRPM4, MYBPC3, SCN5A, KCNE1, LMNA, GJA5 genes was found in other nine cases (60%). Of these, three unrelated patients (20%) presented the same heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene. Diagnostic re-assessment over time led to a diagnosis of Brugada syndrome and long-QT syndrome in two patients (13%). No cardiac events occurred during a median follow-up of 72 months. CONCLUSION: Idiopathic AVB in adults younger than 50 years is a very rare condition with an incidence of 0.7 per 100 000 persons/year. Systematic investigations, including genetic testing and ajmaline challenge, can lead to the achievement of a specific diagnosis in up to 20% of patients. Heterozygous missense variant c.2531G > A p.(Gly844Asp) in TRPM4 gene was found in an additional 20% of unrelated patients, suggesting possible association of the variant with the disease.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Adulto Joven , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Trastorno del Sistema de Conducción Cardíaco/complicaciones , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/epidemiología , Bloqueo Atrioventricular/genética , Marcapaso Artificial/efectos adversos , Pruebas Genéticas , Ajmalina
3.
Cardiology ; 148(5): 441-447, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37487479

RESUMEN

INTRODUCTION: Long-term complication rates in standard transvenous pacemakers are reported around 4-12% with a higher incidence in the elderly population. We report our experience in octogenarians undergoing leadless pacemaker implantation in two large-volume centers in Switzerland. METHODS: Consecutive patients undergoing leadless pacemaker implantation at two Swiss large volume centers (University Hospital Zurich, Zurich and Cardiocentro Ticino Institute, Lugano) between October 2015 and March 2020 were included in this retrospective analysis. Demographic information, clinical data, and procedural characteristics were recorded at the day of implantation and during follow-up. RESULTS: Two hundred and twenty patients (mean age 80.6 ± 7.7 years, male 66%) were included. The main indication for pacemaker implantation was slow ventricular rate atrial fibrillation (111 of 220 patients, 50.4%). Out of the 220 patients, 124 (56.3%) were ≥80 years. Overall successful implantation rate was 98.6%. In the octogenarian population, the median procedure time (45 ± 20.2 min vs. 40 ± 19.6 min, p = 0.03) and radiation duration (6.1 ± 8.2 min vs. 5.0 ± 7.2 min, p = 0.03) were longer compared to patients <80 years. Major complications (2.7%, n = 6) and device measurements during follow-up were similar between patients ≥80 and <80 years. CONCLUSION: Implantation of a leadless pacemaker device in octogenarians is safe and effective with a similarly low complication rate compared to non-octogenarians.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Anciano de 80 o más Años , Humanos , Masculino , Anciano , Octogenarios , Estudios Retrospectivos , Resultado del Tratamiento , Fibrilación Atrial/terapia , Fibrilación Ventricular , Diseño de Equipo
4.
Europace ; 23(4): 640-647, 2021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33241411

RESUMEN

AIMS: Non-invasive imaging of electrical activation requires high-density body surface potential mapping. The nine electrodes of the 12-lead electrocardiogram (ECG) are insufficient for a reliable reconstruction with standard inverse methods. Patient-specific modelling may offer an alternative route to physiologically constraint the reconstruction. The aim of the study was to assess the feasibility of reconstructing the fully 3D electrical activation map of the ventricles from the 12-lead ECG and cardiovascular magnetic resonance (CMR). METHODS AND RESULTS: Ventricular activation was estimated by iteratively optimizing the parameters (conduction velocity and sites of earliest activation) of a patient-specific model to fit the simulated to the recorded ECG. Chest and cardiac anatomy of 11 patients (QRS duration 126-180 ms, documented scar in two) were segmented from CMR images. Scar presence was assessed by magnetic resonance (MR) contrast enhancement. Activation sequences were modelled with a physiologically based propagation model and ECGs with lead field theory. Validation was performed by comparing reconstructed activation maps with those acquired by invasive electroanatomical mapping of coronary sinus/veins (CS) and right ventricular (RV) and left ventricular (LV) endocardium. The QRS complex was correctly reproduced by the model (Pearson's correlation r = 0.923). Reconstructions accurately located the earliest and latest activated LV regions (median barycentre distance 8.2 mm, IQR 8.8 mm). Correlation of simulated with recorded activation time was very good at LV endocardium (r = 0.83) and good at CS (r = 0.68) and RV endocardium (r = 0.58). CONCLUSION: Non-invasive assessment of biventricular 3D activation using the 12-lead ECG and MR imaging is feasible. Potential applications include patient-specific modelling and pre-/per-procedural evaluation of ventricular activation.


Asunto(s)
Electrocardiografía , Modelación Específica para el Paciente , Mapeo del Potencial de Superficie Corporal , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética
5.
Europace ; 23(11): 1751-1756, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34534277

RESUMEN

AIMS: Data regarding the efficacy of catheter ablation in heart failure patients with severely dilated left atrium and reduced left ventricular ejection fraction (LVEF) are scanty. We sought to assess the efficacy of catheter ablation in patients with reduced LVEF and severe left atrial (LA) enlargement, and to compare it to those patients with preserved left ventricular function and equally dilated left atrium. METHODS AND RESULTS: Three patient groups with paroxysmal or persistent atrial fibrillation (AF) undergoing a first pulmonary vein isolation (PVI) were considered: Group 1 included patients with normal or mildly abnormal LA volume (≤41 mL/m2) and normal LVEF; Group 2 included patients with severe LA enlargement (>48 mL/m2) and normal LVEF; and Group 3 included patients with severe LA enlargement and reduced LVEF. Time to event analysis was used to investigate AF recurrences. The study cohort includes 439 patients; Group 3 had a higher prevalence of cardiovascular risk factors. LA enlargement was associated with a two-fold in risk of AF recurrence, on the contrary only a smaller non-significant increase of 30% was shown with the further addition of LVEF reduction. CONCLUSIONS: The long-term outcome of patients with severe LA dilatation and reduced LVEF is comparable to those with severe LA enlargement but preserved LVEF. Long-term efficacy of PVI is certainly affected by the enlargement of the left atrium, but less so by the addition of a reduced LVEF. CA remains the best strategy for rhythm control both in paroxysmal and persistent AF in this subgroup of patients.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Venas Pulmonares/cirugía , Recurrencia , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
6.
Europace ; 22(11): 1653-1658, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32830231

RESUMEN

AIMS: To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon's versions. METHODS AND RESULTS: Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months. CONCLUSION: High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Catéteres , Criocirugía/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
7.
Europace ; 22(5): 777-786, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31942982

RESUMEN

AIMS: The aim of this study was to determine the relationship between electrical and mechanical activation in heart failure (HF) patients and whether electromechanical coupling is affected by scar. METHODS AND RESULTS: Seventy HF patients referred for cardiac resynchronization therapy or biological therapy underwent endocardial anatomo-electromechanical mapping (AEMM) and delayed-enhancement magnetic resonance (CMR) scans. Area strain and activation times were derived from AEMM data, allowing to correlate mechanical and electrical activation in time and space with unprecedented accuracy. Special attention was paid to the effect of presence of CMR-evidenced scar. Patients were divided into a scar (n = 43) and a non-scar group (n-27). Correlation between time of electrical and mechanical activation was stronger in the non-scar compared to the scar group [R = 0.84 (0.72-0.89) vs. 0.74 (0.52-0.88), respectively; P = 0.01]. The overlap between latest electrical and mechanical activation areas was larger in the absence than in presence of scar [72% (54-81) vs. 56% (36-73), respectively; P = 0.02], with smaller distance between the centroids of the two regions [10.7 (4.9-17.4) vs. 20.3 (6.9-29.4) % of left ventricular radius, P = 0.02]. CONCLUSION: Scar decreases the association between electrical and mechanical activation, even when scar is remote from late activated regions.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Cicatriz/diagnóstico por imagen , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética
8.
J Cardiovasc Electrophysiol ; 30(7): 1086-1095, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30980441

RESUMEN

INTRODUCTION: Little data are available on anticoagulation (AC) management in patients with cardiac resynchronization (CRT) devices who undergo transvenous lead extraction (TLE) procedure. We investigated the impact of AC on periprocedural complications in CRT patients undergoing TLE, enrolled in the ESC-EHRA European Lead Extraction ConTrolled (ELECTRa) registry. METHODS AND RESULTS: All CRT patients treated with TLE enrolled in the registry were considered. Perioperative AC management was left to the discretion of the Center. Major and minor intraprocedural and postprocedural complications were compared between patients without AC (Gp1) and patients with AC (Gp2). Regression analyses were performed to identify predictors of complications for Gp2. Out of 734 CRT pts, 328 (44.7%) were under AC (Gp2). Patients from Gp2 presented lower LVEF (Gp2 32.5 ± 10.9 vs Gp1 34.5 ± 11.9%; P = 0.03), more advanced heart failure disease (NYHA III/IV: Gp2 42.0 vs Gp1 31.5%; P = 0.02), and renal impairment (Gp2 39.0 vs Gp1 24.3%; P < 0.001). Perioperative regimens included AC interruption (Gp2A: n = 169, 51.5%), "bridging" (Gp2B: n = 135, 41.2%), or continued AC (Gp2C: n = 24, 7.3%). TLE complete success rates (98% in both groups) and major complication rates were comparable for both groups; minor bleeding events were more frequent in Gp2 (5.5%) compared to Gp1 (2.5%; P = 0.051). No independent predictors were identified for Gp2, but minor complications were associated with "bridging" approach (Gp2B: 16 events vs Gp2A/C: 9 events; P = 0.020). CONCLUSION: CRT patients treated with TLE under AC were more compromised but did not present more major complications compared to patients without AC. More minor complications were associated with "bridging" AC regimen.


Asunto(s)
Anticoagulantes/administración & dosificación , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Remoción de Dispositivos , Insuficiencia Cardíaca/terapia , Anciano , Anticoagulantes/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Remoción de Dispositivos/efectos adversos , Europa (Continente) , Femenino , Estado de Salud , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Hemorragia/inducido químicamente , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Europace ; 21(7): 1096-1105, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31505593

RESUMEN

AIMS: A sub-analysis of the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) Registry to evaluate the clinical impact of antithrombotic (AT) on transvenous lead extraction (TLE) safety and efficacy. METHODS AND RESULTS: ELECTRa outcomes were compared between patients without AT therapy (No AT Group) and with different pre-operative AT regimens, including antiplatelets (AP), anticoagulants (AC), or both (AP + AC). Out of 3510 pts, 2398 (68%) were under AT pre-operatively. AT patients were older with more comorbidities (P < 0.0001). AT subgroups, defined as AP, AC, or AP + AC, were 1096 (31.2%), 985 (28%), and 317 (9%), respectively. Regarding AP patients, 1413 (40%) were under AP, 1292 (91%) with a single AP, interrupted in 26% about 3.8 ± 3.7 days before TLE. In total, 1302 (37%) patients were under AC, 881 vitamin K antagonist (68%), 221 (17%) direct oral anticoagulants, 155 (12%) low weight molecular heparin, and 45 (3.5%) unfractionated heparin. AC was 'interrupted without bridging' in 696 (54%) and 'interrupted with bridging' in 504 (39%) about 3.3 ± 2.3 days before TLE, and 'continued' in 87 (7%). TLE success rate was high in all subgroups. Only overall in-hospital death (1.4%), but not the procedure-related one, was higher in the AT subgroups (P = 0.0500). Age >65 years and New York Heart Association Class III/IV, but not AT regimens, were independent predictors of death for any cause. Haematomas were more frequent in AT subgroups, especially in AC 'continued' (P = 0.025), whereas pulmonary embolism in the No-AT (P < 0.01). CONCLUSIONS: AT minimization is safe in patients undergoing TLE. AT does not seem to predict death but identifies a subset of fragile patients with a worse in-hospital TLE outcome.


Asunto(s)
Remoción de Dispositivos/efectos adversos , Electrodos Implantados , Fibrinolíticos/administración & dosificación , Marcapaso Artificial , Complicaciones Posoperatorias/epidemiología , Factores de Edad , Anciano , Comorbilidad , Falla de Equipo , Europa (Continente)/epidemiología , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Factores de Riesgo
10.
Europace ; 21(5): 771-780, 2019 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-30590520

RESUMEN

AIMS: We aimed at describing outcomes and predictors of cardiac avulsion or tear (CA/T) with tamponade and vascular avulsion or tear (VA/T) after transvenous lead extraction (TLE) in the ESC-EHRA European Lead Extraction ConTRolled (ELECTRa) registry. METHODS AND RESULTS: A total of 3555 consecutive patients of whom 3510 underwent TLE at 73 centres in 19 European countries were enrolled. Among 58 patients (1.7%) with procedure-related major complications, 49 (84.5%) patients (30 CA/T and 19 VA/T) presented cardiovascular complications requiring pericardiocentesis, chest tube positioning and/or surgical repair. The mortality was 20% in patients with tamponade due to CA/T and 31.6% in patients with VA/T. Pericardiocentesis as first manoeuvre followed by rescue surgical repair was highly effective in case of CA/T (93.8%). At multivariate analysis, CA/T with tamponade was more common in RIATA lead extraction, female patients, leads with a mean dwelling time more than 10 years, and when ≥3 leads were extracted or multiple sheaths required. Occlusion or critical stenosis of superior venous access and the leads mean dwelling time more than 10 years were independent predictors for VA/T, while mechanical dilatation was an independent predictor of a lower incidence of this complication as compared to the use of powered sheaths. CONCLUSIONS: In the ELECTRa registry, RIATA lead extraction and superior venous access occlusion/thrombosis are two new independent predictors for cardiac tamponade and major vascular complications, respectively. The use of mechanical sheaths seems to be associated with a lower incidence of VA/T. A strategy of pericardiocentesis followed by a rescue surgical approach seems to be reasonable in order to treat a CA/T with tamponade.


Asunto(s)
Taponamiento Cardíaco , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Marcapaso Artificial/efectos adversos , Pericardiocentesis , Complicaciones Posoperatorias , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/mortalidad , Taponamiento Cardíaco/cirugía , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/métodos , Falla de Equipo , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Evaluación de Procesos y Resultados en Atención de Salud , Pericardiocentesis/métodos , Pericardiocentesis/estadística & datos numéricos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/cirugía , Pronóstico , Sistema de Registros/estadística & datos numéricos , Factores de Riesgo , Trombosis/diagnóstico , Trombosis/epidemiología , Lesiones del Sistema Vascular/diagnóstico , Lesiones del Sistema Vascular/epidemiología
11.
Europace ; 21(11): 1670-1677, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31504477

RESUMEN

AIMS: To define the clinical characteristics and long-term clinical outcomes of a large cohort of patients with idiopathic ventricular fibrillation (IVF) and normal 12-lead electrocardiograms (ECGs). METHODS AND RESULTS: Patients with ventricular fibrillation as the presenting rhythm, normal baseline, and follow-up ECGs with no signs of cardiac channelopathy including early repolarization or atrioventricular conduction abnormalities, and without structural heart disease were included in a registry. A total of 245 patients (median age: 38 years; males 59%) were recruited from 25 centres. An implantable cardioverter-defibrillator (ICD) was implanted in 226 patients (92%), while 18 patients (8%) were treated with drug therapy only. Over a median follow-up of 63 months (interquartile range: 25-110 months), 12 patients died (5%); in four of them (1.6%) the lethal event was of cardiac origin. Patients treated with antiarrhythmic drugs only had a higher rate of cardiovascular death compared to patients who received an ICD (16% vs. 0.4%, P = 0.001). Fifty-two patients (21%) experienced an arrhythmic recurrence. Age ≤16 years at the time of the first ventricular arrhythmia was the only predictor of arrhythmic recurrence on multivariable analysis [hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.18-0.92; P = 0.03]. CONCLUSION: Patients with IVF and persistently normal ECGs frequently have arrhythmic recurrences, but a good prognosis when treated with an ICD. Children are a category of IVF patients at higher risk of arrhythmic recurrences.


Asunto(s)
Desfibriladores Implantables , Electrocardiografía , Paro Cardíaco Extrahospitalario/etiología , Sistema de Registros , Fibrilación Ventricular/complicaciones , Adolescente , Adulto , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapia , Valores de Referencia , Estudios Retrospectivos , Factores de Tiempo , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/fisiopatología , Adulto Joven
12.
BMC Cardiovasc Disord ; 19(1): 146, 2019 06 17.
Artículo en Inglés | MEDLINE | ID: mdl-31208342

RESUMEN

BACKGROUND: Little is known about the ICD performance using enhanced detection algorithms in unselected, non-trial patients. Performance of recent generation ICD equipped with SmartShock™ technology (SST) for detection and conversion of ventricular tachyarrhythmias (VTA) was investigated. METHODS: 4P was a prospective, multicenter, observational study conducted in 10 Swiss implanting centers. Patients with a Class I indication according to international guidelines were included and received an ICD with SST. ICD discrimination capability was assessed by evaluating SST performance; therapy efficacy was assessed by rate of VTA conversions by ATP and by rescue shocks. RESULTS: Overall, 196 patients were included in the analysis with a mean duration of follow-up of 27.7 months (452 patient-years of observation). Patient-specific rather than recommended programming was preferred. Device-detected episodes were frequent (5147 episodes in 146 patients, 74.5%). In 44 patients (22.4%), 1274 episodes were categorized as VTA; only 215 episodes were symptomatic. ATP was the first-line therapy and highly effective (99.9% success rate at the episode level, 100.0% at the patient level). Rescue shocks were rare (66 episodes in 28 patients); 7 shocks in 5 patients (2.6%) were inappropriate. Death and hospitalization rates were low. CONCLUSIONS: In a cohort of non-trial, unselected ICD patients, VTA episodes were frequent. The 4P results confirm the robustness of VTA detection by SST and the effectiveness of ATP treatment, hence limiting overall ICD shock burden.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Frecuencia Cardíaca , Taquicardia Ventricular/terapia , Fibrilación Ventricular/terapia , Anciano , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Estudios Prospectivos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Suiza , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología
13.
Europace ; 20(11): 1827-1832, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29672695

RESUMEN

Aims: Phrenic nerve palsy (PNP) after mechanical transvenous lead extraction (TLE) was recently described for the first time. We aimed to analyse our TLE database for the presence of PNP. Methods and results: All consecutive patients referred to our institution were included in this study. Every available post-procedural chest X-ray was compared to the routinely performed pre-procedural radiographs. A newly elevated hemidiaphragm ipsilateral to TLE was considered indicative of PNP. Altogether 255 TLE procedures with extraction of 364 leads were performed. Most common TLE indication was lead malfunction (63%). Complete radiographic success rate was 97.3% with an in-hospital procedure-related major complication rate of 2.4%, including one intra-procedural death (0.4%). We identified five cases with PNP (2%), all occurring after laser-assisted TLE. Clinical presentation varied from subtle and aspecific chest pain/discomfort to severe and acute dyspnoea, with time to diagnosis varying from immediate to several weeks after the procedure. In 80% of cases, the explanted lead was a defibrillator electrode and the median lead dwelling time was 70.2 months (29.3; 1084.9). In four cases, the extraction was performed using high-energy laser (pulse repetition rate 80 Hz). Conclusion: The present study reports the incidence of PNP after laser-assisted TLE. We postulate that the thermal energy generated by laser is not dissipated quickly enough in occluded or heavily calcified lesions, injuring the ipsilateral phrenic nerve. Our findings advise to carefully consider to increase pulse repetition rate at the subclavian level. Larger, possibly prospective studies are needed to evaluate the real incidence through systematic radiological assessment after TLE.


Asunto(s)
Remoción de Dispositivos , Diafragma/inervación , Terapia por Láser/efectos adversos , Rayos Láser , Traumatismos de los Nervios Periféricos , Nervio Frénico/lesiones , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/métodos , Desfibriladores Implantables , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/métodos , Falla de Equipo/estadística & datos numéricos , Femenino , Humanos , Incidencia , Complicaciones Intraoperatorias/diagnóstico , Complicaciones Intraoperatorias/epidemiología , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Traumatismos de los Nervios Periféricos/diagnóstico , Traumatismos de los Nervios Periféricos/epidemiología , Traumatismos de los Nervios Periféricos/etiología , Radiografía Torácica/métodos , Ajuste de Riesgo , Suiza
14.
Europace ; 20(suppl_3): iii26-iii35, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30476052

RESUMEN

AIMS: P-wave beat-to-beat morphological variability can identify patients prone to paroxysmal atrial fibrillation (AF). To date, no computational study has been carried out to mechanistically explain such finding. The aim of this study was to provide a pathophysiological explanation, by using a computer model of the human atria, of the correlation between P-wave beat-to-beat variability and the risk of AF. METHODS AND RESULTS: A physiological variability in the earliest activation site (EAS), on a beat-to-beat basis, was introduced into a computer model of the human atria by randomizing the EAS location. A methodology for generating multi-scale, spatially-correlated regions of heterogeneous conduction was developed. P-wave variability in the presence of such regions was compared with a control case. Simulations were performed with an eikonal model, for the activation map, and with the lead field approach, for P-wave computation. The methodology was eventually compared with a reference monodomain simulation. A total of 60 P-waves were simulated for each sinus node exit location (12 in total), and for each of the 15 patterns of heterogeneous conduction automatically generated by the model. A P-wave beat-to-beat variability was observed in all cases. Variability was significantly increased in presence of heterogeneous slow conducting regions, up to two-fold the variability in the control case. P-wave variability increased non-linearly with respect to the EAS variability and total area of slow conduction. Distribution of the heterogeneous conduction was more effective in increasing the variability when it surrounded the EAS locations and the fast conducting bundles. P-waves simulated by the eikonal approach compared excellently with the monodomain-based ones. CONCLUSION: P-wave variability in patients with paroxysmal AF could be explained by a variability in sinoatrial node exit location in combination with slow conducting regions.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/fisiopatología , Simulación por Computador , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Modelos Cardiovasculares , Fibrilación Atrial/diagnóstico , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Atrios Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Factores de Tiempo
15.
Europace ; 20(7): 1188-1193, 2018 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-28340026

RESUMEN

Aims: Subcutaneous implantable cardioverter-defibrillator (S-ICD) can avoid important complications associated with transvenous leads in patients with inherited primary arrhythmia syndromes, who do not need pacing therapy. Few data are available on the percentage of patients with inherited arrhythmia syndromes eligible for S-ICD implantation. Aim of this study was to analyse the eligibility for S-ICD in a series of patients with Brugada syndrome (BrS), and to compare it with patients with other channelopathies. Methods and results: Patients presenting with BrS, long-QT syndrome (LQTS), early repolarization syndrome (ERS), and idiopathic ventricular fibrillation (IVF) were considered eligible for this study. ECG screening was performed by analysis of QRS complex and T wave morphology recorded in standing and supine position. Eligibility was defined when ≥1 sense vector was acceptable in both supine and standing position. A total of 100 patients (72 males; mean age: 46 ± 17 years) underwent S-ICD sensing screening. Sixty-one patients presented with BrS, 21 with LQTS, 14 with IVF, and 4 with ERS. Thirty-four patients with BrS (56%) presented with spontaneous type 1 ECG. In the other 27 patients (44%), type 1 ECG was unmasked by ajmaline. Overall, rate of screening failure was 13%. Patients with BrS had a higher rate of inappropriate morphology analysis as compared with other channelopathies (18% vs. 5%, P = 0.07) and had a lower number of suitable sensing vectors (49.6% vs. 84.7% vs. P < 0.001). Ajmaline challenge unmasked sensing failure in 14.8% of drug-induced BrS patients previously considered eligible. In all patients, the reason for sensing inappropriateness was due to the presence of high T wave voltages. Conclusion: S-ICD screening failure occurs in up to 13% of patients with inherited primary arrhythmia syndromes. Patients with BrS present a higher rate of screening failure as compared with other cardiac channelopathies.


Asunto(s)
Síndrome de Brugada/diagnóstico , Síndrome de Brugada/cirugía , Toma de Decisiones Clínicas , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Electrocardiografía , Determinación de la Elegibilidad , Selección de Paciente , Adulto , Síndrome de Brugada/genética , Síndrome de Brugada/fisiopatología , Europa (Continente) , Femenino , Predisposición Genética a la Enfermedad , Herencia , Humanos , Masculino , Persona de Mediana Edad , Fenotipo , Valor Predictivo de las Pruebas , Tokio , Vectorcardiografía
16.
Europace ; 20(suppl_3): iii77-iii86, 2018 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-30476054

RESUMEN

AIMS: The aim of this study was to investigate the influence of the activation sequence on voltage amplitudes by evaluating regional voltage differences during a left bundle branch block (LBBB) activation sequence vs. a normal synchronous activation sequence and by evaluating pacing-induced voltage differences. METHODS AND RESULTS: Twenty-one patients and three computer models without scar were studied. Regional voltage amplitudes were evaluated in nine LBBB patients who underwent endocardial electro-anatomic mapping (EAM). Pacing-induced voltage differences were evaluated in 12 patients who underwent epicardial EAM during intrinsic rhythm and right ventricular (RV) pacing. Three computer models customized for LBBB patients were created. Changes in voltage amplitudes after an LBBB (intrinsic), a normal synchronous, an RV pacing, and a left ventricular pacing activation sequence were assessed in the computer models. Unipolar voltage amplitudes in patients were approximately 4.5 mV (4.4-4.7 mV, ∼33%) lower in the septum when compared with other segments. A normal synchronous activation sequence in the computer models normalized voltage amplitudes in the septum. Pacing-induced differences were larger in electrograms with higher voltage amplitudes during intrinsic rhythm and furthermore larger and more variable at the epicardium [mean absolute difference: 3.6-6.2 mV, 40-53% of intrinsic value; interquartile range (IQR) differences: 53-63% of intrinsic value] compared to the endocardium (mean absolute difference: 3.3-3.8 mV, 28-30% of intrinsic value; IQR differences: 37-40% of intrinsic value). CONCLUSION: In patients and computer models without scar, lower septal unipolar voltage amplitudes are exclusively associated with an LBBB activation sequence. Pacing substantially affects voltage amplitudes, particularly at the epicardium.


Asunto(s)
Potenciales de Acción , Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Simulación por Computador , Frecuencia Cardíaca , Modelos Cardiovasculares , Adulto , Anciano , Anciano de 80 o más Años , Fascículo Atrioventricular/diagnóstico por imagen , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
17.
Europace ; 19(2): 259-266, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28175278

RESUMEN

Aims: Out-of-hospital cardiac arrest (OHCA) in the absence of evident structural heart disease is rare and can be due to subclinical cardiomyopathy and primary electrical disorders, including idiopathic ventricular fibrillation (IVF) with early repolarization (ER) pattern. Aim of this study was to investigate prevalence, clinical features, and long-term prognosis of IVF in OHCA survivors with otherwise normal 12-lead electrocardiograms (ECGs). Methods and Results: Patients with IVF in the absence of ER pattern or atrioventricular conduction abnormalities were considered eligible for this study. A total of 3407 OHCAs occurred in our region from 2000 to 2014. Out-of-hospital cardiac arrests of presumed cardiac origin were 2192; of them, 644 presented with a ventricular arrhythmia (VT/VF) as first shockable rhythm. Among them, a total of 74 implantable cardioverter-defibrillators were implanted for secondary prevention. Ventricular arrhythmia was considered idiopathic in 11 (15%) of these patients. Over a mean follow-up time of 85 ± 47 months (median: 42 months), ECG was found abnormal in three cases. In the remaining eight patients (6 males; median age: 45 years), no ECG or structural abnormalities were detected during the follow-up. Prevalence of IVF in OHCA survivors with first-shockable rhythm was 1.2%. During the long-term follow-up, no patient died or experienced ICD interventions. No new echocardiographic abnormal findings were revealed. Conclusion: Idiopathic ventricular fibrillation is rare occurring in 1.2% of OHCA survivors presenting with a shockable rhythm. The initial diagnosis can change in up to 27% of cases. Patients with IVF and no ER pattern or AV conduction disturbances have a good prognosis during a long-term follow-up.


Asunto(s)
Paro Cardíaco Extrahospitalario/epidemiología , Sobrevivientes , Fibrilación Ventricular/epidemiología , Desfibriladores Implantables , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paro Cardíaco Extrahospitalario/prevención & control , Prevalencia , Prevención Secundaria , Suiza/epidemiología , Fibrilación Ventricular/terapia
18.
Europace ; 18(suppl 4): iv23-iv34, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28011828

RESUMEN

AIMS: Apparently conflicting clinical measurements of P-wave duration (PWD) pre- vs. post-ablation have been reported. To assist the interpretation of these clinical data, we used a computer model of the atria and torso to simulate P waves before and after pulmonary vein (PV) isolation. METHODS AND RESULTS: Twenty ablation patterns were designed (segmental or ipsilateral ablation; five distances to PV sleeves; addition of a roof line or not). Possible PV reconnections were introduced as gaps in the ablation lines. PWD and area were measured during sinus rhythm in vectorcardiogram (VCG) magnitude signals and on the 16-lead ECG before and after ablation, and after PV reconnection. After PV isolation, biatrial activation time was prolonged by 0-5 ms without and by 48±5 ms with roof line. Yet PWD was shortened in lead V3 and V4 by up to 15 ms. The effect of ablation on P-wave morphology was stronger when larger PV areas were isolated. Segmental and ipsilateral PV isolation led to concordant results. P-wave area increased in V1 and decreased in V6. Changes in PWD and area on the VCG were sensitive to the threshold used for detecting the end of the P wave. The occurrence of PV reconnection was best identified on leads V3, V4, and V9. CONCLUSION: PV isolation and reconnection induced measurable changes on the 16-lead ECG that might be used to improve patient follow-up after ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Atrios Cardíacos/cirugía , Modelos Cardiovasculares , Modelación Específica para el Paciente , Venas Pulmonares/cirugía , Potenciales de Acción , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Electrocardiografía , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Cinética , Modelos Anatómicos , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Torso/anatomía & histología , Resultado del Tratamiento
19.
Pacing Clin Electrophysiol ; 39(8): 900-2, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26970532

RESUMEN

Left atrial appendage (LAA) closure is indicated in patients with atrial fibrillation (AF) and high bleeding as well as thromboembolic risks. A subgroup of these patients may also present an indication for a single-chamber permanent pacemaker due to symptomatic low-rate AF or when "ablate and pace" strategy is indicated for rate control. A miniaturized wireless transcatheter pacing system (TPS) is now available as a single-chamber permanent pacemaker. This case presents how combined LAA closure and permanent pacemaker implant, by means of TPS, is feasible through a single femoral venous access.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/terapia , Vena Femoral/cirugía , Marcapaso Artificial , Implantación de Prótesis/métodos , Dispositivos de Cierre Vascular , Anciano , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Terapia Combinada/instrumentación , Terapia Combinada/métodos , Humanos , Masculino , Resultado del Tratamiento , Tecnología Inalámbrica/instrumentación
20.
J Electrocardiol ; 48(4): 617-25, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26025201

RESUMEN

AIM: The aim of this study was to investigate the influence of geometrical factors on the ECG morphology and vectorcardiogram (VCG) parameters. METHODS: Patient-tailored models based on five heart-failure patients with intraventricular conduction defects (IVCDs) were created. The heart was shifted up to 6 cm to the left, right, up, and down and rotated ±30° around the anteroposterior axis. Precordial electrodes were shifted 3 cm down. RESULTS: Geometry modifications strongly altered ECG notching/slurring and intrinsicoid deflection time. Maximum VCG parameter changes were small for QRS duration (-6% to +10%) and QRS-T angle (-6% to +3%), but considerable for QRS amplitude (-36% to +59%), QRS area (-37% to +42%), T-wave amplitude (-41% to +36%), and T-wave area (-42% to +33%). CONCLUSION: The position of the heart with respect to the electrodes is an important factor determining notching/slurring and voltage-dependent parameters and therefore must be considered for accurate diagnosis of IVCDs.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Modelos Cardiovasculares , Posicionamiento del Paciente/métodos , Vectorcardiografía/métodos , Anciano , Arritmias Cardíacas/complicaciones , Arritmias Cardíacas/diagnóstico , Simulación por Computador , Diagnóstico por Computador/métodos , Electrocardiografía/métodos , Femenino , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Modelación Específica para el Paciente , Postura , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA