Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Rev Esp Enferm Dig ; 112(10): 768-771, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33023293

RESUMEN

Neuroendocrine tumors (NET) are a heterogeneous group of neoplasms that originate in tissues derived from the neural crest, whose characteristic feature is the expression of neuroendocrine markers and somatostatin receptors. Here, we present the case of a patient with a surgically intervened small bowel NET. Focal uptake was identified in the unresected mesentery in the scintigraphy of somatostatin receptors (99mTc-Tektrotyd). A second intervention was performed with intraoperative radio-guided detection with a gamma probe and a handheld SPECT. An intraoperative radioguided technique allowed the detection of a lesion that was confirmed by histology to be a lymph node metastasis of the NET and a nodule of NET in the anastomosis of the first surgical intervention.


Asunto(s)
Neoplasias de la Mama , Tumores Neuroendocrinos , Neoplasias Pancreáticas , Femenino , Humanos , Metástasis Linfática , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/cirugía , Neoplasias Pancreáticas/diagnóstico por imagen , Cintigrafía , Radiofármacos
2.
J Nucl Med Technol ; 36(4): 213-6, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19008289

RESUMEN

UNLABELLED: Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. METHODS: (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared. RESULTS: The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h. CONCLUSION: The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results.


Asunto(s)
Almacenaje de Medicamentos/métodos , Jeringas , Exametazima de Tecnecio Tc 99m/análisis , Exametazima de Tecnecio Tc 99m/química , Evaluación Preclínica de Medicamentos , Estabilidad de Medicamentos , Semivida , Radiofármacos/análisis , Radiofármacos/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA