Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Urol ; 116(1): 94-5, 1976 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-933301

RESUMEN

A case of pneumomediastinum, which appeared after a biopsy of the right kidney by minimal lumbotomy, is reported. The anatomicopathological condition of the renal fragment obtained was judged to be focal and segmental hyalinosis. We wish to emphasize the rarity of such a complication, the type of electrocardiographic changes observed, and the rapid and spontaneous recuperation of the patient without further repercussions.


Asunto(s)
Biopsia/efectos adversos , Enfisema Mediastínico/etiología , Síndrome Nefrótico/diagnóstico , Adulto , Auscultación , Electrocardiografía , Femenino , Humanos , Enfisema Mediastínico/diagnóstico , Fonocardiografía , Radiografía Torácica
2.
Nephrol Dial Transplant ; 13(9): 2335-40, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9761518

RESUMEN

BACKGROUND: A prospective sequential study on continuous ambulatory peritoneal dialysis (CAPD) and three techniques of automated peritoneal dialysis (APD) was conducted to assess peritoneal clearances, the influence of peritoneal permeability on nocturnal APD clearances and the suitability of the peritoneal equilibration test (PET) for predicting clearances on APD. METHODS: After performing a PET, a series of clinical, biochemical and dialysis adequacy markers were evaluated after 2 months on CAPD, continuous cycling peritoneal dialysis (CCPD) and tidal volume peritoneal dialysis (TPD) with 50% and 25% tidal volumes. Forty five patients participated and 33 completed the study. RESULTS: Serum urea and creatinine decreased significantly whereas haemoglobin and glucose increased. Mean peritoneal urea clearance (1/week) was 55.40+/-8.76 on CAPD, 74.82+/-12.62 on CCPD, 69.20+/-14.63 on TPD (tidal 50%) and 66.89+/-13.23 on TPD (tidal 25%); mean creatinine clearance (1/week/1.73 m2) was 42.80 +/- 9.95, 52.19 +/- 11.11, 51.31 +/- 13.3 and 49.17 +/- 11.83, respectively. Both clearances were significantly lower on CAPD than on APD (P<0.001). CCPD was the automated technique that provided the best nocturnal urea clearance (P<0.01). Nocturnal creatinine clearance did not show significant differences between CCPD and TPD (tidal 50%), being better with both techniques than with TPD (tidal 25%). There were statistically significant differences between nocturnal dialysate to plasma (D/P) ratios and those corresponding to the nearest times in the PET. The urea D/P ratio at 180 min and the creatinine D/P ratio at 240 min of the PET were the parameters that better estimated nocturnal clearances on APD. CONCLUSIONS: This study confirms that TPD does not improve the results of CCPD. Significant differences between D/P ratios during actual nocturnal cycles and PETs were observed.


Asunto(s)
Diálisis Peritoneal/métodos , Anciano , Automatización , Transporte Biológico/fisiología , Creatinina/sangre , Creatinina/farmacocinética , Soluciones para Diálisis/química , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diálisis Peritoneal Ambulatoria Continua , Peritoneo/metabolismo , Permeabilidad , Estudios Prospectivos , España , Volumen de Ventilación Pulmonar , Resultado del Tratamiento , Urea/sangre , Urea/farmacocinética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA