Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Spine J ; 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39017731

RESUMEN

PURPOSE: Screwed anterior lumbar interbody fusion (SALIF) alleviates the need for supplemental posterior fixation leading to reduction of perioperative morbidity. Specifically, elderly and multimorbid patients would benefit from shorter operative time and faster recovery but tend to have low bone mineral density (BMD). The current study aimed to compare loosening, defined as increase of ROM and NZ, of SALIF versus transforaminal lumbar interbody fusion (TLIF) under cyclic loading in cadaveric spines with reduced BMD. METHODS: Twelve human spines (L4-S2; 6 male 6 female donors; age 70.6 ± 19.6; trabecular BMD of L5 84.2 ± 24.4 mgHA/cm3, range 51-119 mgHA/cm3) were assigned to two groups. SALIF or TLIF were instrumented at L5/S1. Range of motion (ROM) and neutral zone (NZ) were assessed before and after axial cyclic loading (0-1150 N, 2000 cycles, 0.5 Hz) in flexion-extension (Flex-Ext), lateral bending, (LB), axial rotation (AR). RESULTS: ROM of the SALIF specimens increased significantly in all loading directions (p ≤ 0.041), except for left AR (p = 0.053), whereas for TLIF it increased significantly in left LB (p = 0.033) and Flex (p = 0.015). NZ of SALIF showed increase in Flex-Ext and LB, whereas NZ of TLIF did not increase significantly in any motion direction. CONCLUSIONS: Axial compression loading caused loosening of SALIF in Flex-Ext and LB, but not TLIF at L5/S1 in low BMD specimens. Nevertheless, Post-cyclic ROM and NZ of SALIF is comparable to TLIF. This suggests that, neither construct is optimal for the use in patients with reduced BMD.

2.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 864-871, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38454816

RESUMEN

PURPOSE: To investigate the forces on a medial collateral ligament (MCL) reconstruction (MCLR) relative to the valgus alignment of the knee. METHODS: Eight fresh-frozen human cadaveric knees were subjected to dynamic valgus loading at 400 N using a custom-made kinematics rig. After resection of the superficial medial collateral ligament, a single-bundle MCLR with a hamstring tendon autograft was performed. A medial opening wedge distal femoral osteotomy was performed and fixed with an external fixator to gradually adjust the alignment in 5° increments from 0° to 10° valgus. For each degree of valgus deformity, the resulting forces acting on the MCLR were measured through a force sensor and captured in 15° increments from 0° to 60° of knee flexion. RESULTS: Irrespective of the degree of knee flexion, increasing valgus malalignment resulted in significantly increased forces acting on the MCLR compared to neutral alignment (p < 0.05). Dynamic loading at 5° valgus resulted in increased forces on the MCLR at all flexion angles ranging between 16.2 N and 18.5 N (p < 0.05 from 0° to 30°; p < 0.01 from 45° to 60°). A 10° valgus malalignment further increased the forces on the MCLR at all flexion angles ranging between 29.4 N and 40.0 N (p < 0.01 from 0° to 45°, p < 0.05 at 60°). CONCLUSION: Valgus malalignment of the knee caused increased forces acting on the reconstructed MCL. In cases of chronic medial instabilities accompanied by a valgus deformity ≥ 5°, a realigning osteotomy should be considered concomitantly to the MCLR to protect the graft and potentially reduce graft failures. LEVEL OF EVIDENCE: Level III.


Asunto(s)
Ligamentos Colaterales , Tendones Isquiotibiales , Humanos , Cadáver , Articulación de la Rodilla/cirugía , Fenómenos Biomecánicos , Ligamentos Colaterales/cirugía
3.
Arch Orthop Trauma Surg ; 144(6): 2905-2914, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38693291

RESUMEN

BACKGROUND: Early mobilization after tendon surgery is crucial to avoid commonly observed postoperative soft tissue adhesions. Recently, a new suture was introduced (DYNACORD; DC) with a salt-infused silicone core designed to minimize laxity and preserve consistent tissue approximation in order to avoid gap formation and allow early mobilization. AIMS: To compare the biomechanical competence of DC against a conventional high strength suture (FiberWire; FW) in a human cadaveric tendon transfer model with an early rehabilitation protocol. METHODS: Sixteen tendon transfers (flexor digitorum superficialis (FDS) IV to flexor pollicis longus (FPL)) were performed in 8 pairs human cadaveric forearms using either DC or FW. Markings were set 0.8 cm proximally and 0.7 cm distally to the level of the interweaving zone of the transfer. All specimens underwent repetitive thumb flexion against resistance in 9 intermittent series of 300 cycles each, simulating an aggressive postoperative rehabilitation protocol. After each series, the distance of the proximal marker to the interweaving zone (proximal), the length of the interweaving zone (intermediate) and the distance of the distal marker to the interweaving zone (distal) were measured. RESULTS: Pooled data over all nine series, normalized to the immediate postoperative status, demonstrated no significant differences between FW and DC (p ≥ 0.355) for the proximal and distal markers. However, at the intermediate zone, DC was associated with significant length shortening (p < 0.001) compared to FW without significant length changes (p = 0.351). Load to catastrophic failure demonstrated significant higher forces in FW (p = 0.011). Nevertheless, due to failure mainly proximal or distal of the transfer zone, these loads are not informative. CONCLUSION: From a biomechanical perspective, DC preserved tissue approximation and might be considered as a valid alternative to conventional high-strength sutures in tendon transfer surgery. DC might allow for a shorter interweaving zone and a more aggressive early postoperative rehabilitation program, possibly avoiding commonly observed postoperative soft tissue adhesions and stiffness.


Asunto(s)
Cadáver , Suturas , Transferencia Tendinosa , Humanos , Transferencia Tendinosa/métodos , Fenómenos Biomecánicos , Extremidad Superior/cirugía , Masculino , Técnicas de Sutura , Anciano , Femenino
4.
Acta Orthop ; 95: 290-297, 2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38874493

RESUMEN

BACKGROUND AND PURPOSE: Recommendations regarding fragment-size-dependent screw fixation trajectory for coronal plane fractures of the posterior femoral condyles (Hoffa fractures) are lacking. The aim of this study was to compare the biomechanical properties of anteroposterior (AP) and crossed posteroanterior (PA) screw fixations across differently sized Hoffa fractures on human cadaveric femora. PATIENTS AND METHODS: 4 different sizes of lateral Hoffa fractures (n = 12 x 4) were created in 48 distal human femora according to the Letenneur classification: (i) type I, (ii) type IIa, (ii) type IIb, and (iv) type IIc. Based on bone mineral density (BMD), specimens were assigned to the 4 fracture clusters and each cluster was further assigned to fixation with either AP (n = 6) or crossed PA screws (n = 6) to ensure homogeneity of BMD values and comparability between the different test conditions. All specimens were biomechanically tested under progressively increasing cyclic loading until failure, capturing the interfragmentary movements via motion tracking. RESULTS: For Letenneur type I fractures, kilocycles to failure (mean difference [∆] 2.1, 95% confidence interval [CI] -1.3 to 5.5), failure load (∆ 105 N, CI -83 to 293), axial displacement (∆ 0.3 mm, CI -0.8 to 1.3), and fragment rotation (∆ 0.5°, CI -3.2 to 2.1) over 5.0 kilocycles did not differ significantly between the 2 screw trajectories. For each separate subtype of Letenneur type II fractures, fixation with crossed PA screws resulted in significantly higher kilocycles to failure (∆ 6.7, CI 3.3-10.1 to ∆ 8.9, CI 5.5-12.3) and failure load (∆ 275 N, CI 87-463 to ∆ 438, CI 250-626), as well as, less axial displacement from 3.0 kilocycles onwards (∆ 0.4°, CI 0.03-0.7 to ∆ 0.5°, CI 0.01-0.9) compared with AP screw fixation. CONCLUSION: Irrespective of the size of Letenneur type II fractures, crossed PA screw fixation provided greater biomechanical stability than AP-configured screws, whereas both screw fixation techniques demonstrated comparable biomechanical competence for Letenneur type I fractures. Fragment-size-dependent treatment strategies might be helpful to determine not only the screw configuration but also the surgical approach.


Asunto(s)
Tornillos Óseos , Cadáver , Fracturas del Fémur , Fijación Interna de Fracturas , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas del Fémur/cirugía , Anciano , Femenino , Masculino , Densidad Ósea , Persona de Mediana Edad , Anciano de 80 o más Años , Estudios de Cohortes
5.
Clin Orthop Relat Res ; 481(10): 2044-2060, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37439643

RESUMEN

BACKGROUND: Staphylococcus aureus is the leading pathogen in fracture-related infection. Previous in vitro experiments, in vivo testing in wax moth larvae, and genomic analysis of clinical S. aureu s isolates from fracture-related infection identified low-virulence (Lo-SA5464) and high-virulence (Hi-SA5458) strains. These findings correlated with acute fracture-related infection induced by Hi-SA5458, whereas Lo-SA5464 caused a chronic fracture-related infection in its human host. However, it remains unclear whether and to what extent the causative pathogen is attributable to these disparities in fracture-related infections. QUESTION/PURPOSE: Are there differences in the course of infection when comparing these two different clinical isolates in a murine fracture-related infection model, as measured by (1) clinical observations of weight loss, (2) quantitative bacteriology, (3) immune response, and (4) radiographic and histopathologic morphology? METHODS: Twenty-five (including one replacement animal) female (no sex-specific influences expected), skeletally mature C57Bl/6N inbred mice between 20 and 28 weeks old underwent femoral osteotomy stabilized by titanium locking plates. Fracture-related infection was established by inoculation of high-virulence S. aureus EDCC 5458 (Hi-SA5458) or low-virulence S. aureus EDCC 5464 (Lo-SA5464) in the fracture gap. Each of these groups consisted of 12 randomly assigned animals. Mice were euthanized 4 and 14 days postsurgery, resulting in six animals per group and timepoint. The severity and progression of infection were assessed in terms of clinical observation of weight loss, quantitative bacteriology, quantitative serum cytokine levels, qualitative analysis of postmortem radiographs, and semiquantitative histopathologic evaluation. RESULTS: For clinical observations of weight change, no differences were seen at Day 4 between Hi-SA5458- and Lo-SA5464-infected animals (mean -0.6 ± 0.1 grams versus -0.8 ± 0.2 grams, mean difference -0.2 grams [95% CI -0.8 to 0.5 grams]; p =0.43), while at 14 days, the Hi-SA5458 group lost more weight than the Lo-SA5464 group (mean -1.55 ± 0.2 grams versus -0.8 ± 0.3 grams; mean difference 0.7 grams [95% CI 0.2 to 1.3 grams]; p = 0.02). Quantitative bacteriological results 4 days postoperatively revealed a higher bacterial load in soft tissue samples in Hi-SA5458-infected animals than in the Lo-SA5464-infected cohort (median 6.8 x 10 7 colony-forming units [CFU]/g, range 2.2 x 10 7 to 2.1 x 10 9 CFU/g versus median 6.0 x 10 6 CFU/g, range 1.8 x 10 5 to 1.3 x 10 8 CFU/g; difference of medians 6.2 x 10 7 CFU/g; p = 0.03). At both timepoints, mice infected with the Hi-SA5458 strain also displayed higher proportions of bacterial dissemination into organs than Lo-SA5464-infected animals (67% [24 of 36 organs] versus 14% [five of 36 organs]; OR 12.0 [95% CI 3.7 to 36]; p < 0.001). This was accompanied by a pronounced proinflammatory response on Day 14, indicated by increased serum cytokine levels of interleukin-1ß (mean 9.0 ± 2.2 pg/mL versus 5.3 ± 1.5 pg/mL; mean difference 3.6 pg/mL [95% CI 2.0 to 5.2 pg/mL]; p < 0.001), IL-6 (mean 458.6 ± 370.7 pg/mL versus 201.0 ±89.6 pg/mL; mean difference 257.6 pg/mL [95% CI 68.7 to 446.5 pg/mL]; p = 0.006), IL-10 (mean 15.9 ± 3.5 pg/mL versus 9.9 ± 1.0 pg/mL; mean difference 6.0 pg/mL [95% CI 3.2 to 8.7 pg/mL]; p < 0.001), and interferon-γ (mean 2.7 ± 1.9 pg/mL versus 0.8 ± 0.3 pg/mL; mean difference 1.8 pg/mL [95% CI 0.5 to 3.1 pg/mL]; p = 0.002) in Hi-SA5458-infected compared with Lo-SA5464-infected animals. The semiquantitative histopathologic assessment on Day 4 revealed higher grades of granulocyte infiltration in Hi-SA5458-infected animals (mean grade 2.5 ± 1.0) than in Lo-SA5464-infected animals (mean grade 1.8 ± 1.4; mean difference 0.7 [95% CI 0.001 to 1.4]; p = 0.0498). On Day 14, bone healing at the fracture site was present to a higher extent in Lo-SA5464-infected animals than in Hi-SA5458-infected animals (mean grade 0.2 ± 0.4 versus 1.8 ± 1.2; mean difference -1.6 [95% CI -2.8 to -0.5]; p = 0.008). CONCLUSION: Similar to septic infection in a human host, infection with Hi-SA5458 in this murine model was characterized by a higher bacterial load, more-pronounced systemic dissemination, and stronger systemic and local inflammation. Thus, there is strong support for the idea that pathogenic virulence plays a crucial role in fracture-related infections. To confirm our observations, future studies should focus on characterizing S. aureus virulence at the genomic and transcriptomic levels in more clinical isolates and patients. Comparing knockout and wildtype strains in vitro and in vivo, including the S. aureus strains studied, could confirm our findings and identify the genomic features responsible for S. aureus virulence in fracture-related infections. CLINICAL RELEVANCE: For translational use, virulence profiles of S. aureus may be useful in guiding treatment decisions in the future. Once specific virulence targets are identified, one approach to fracture-related infections with high-virulence strains might be the development of antivirulence agents, particularly to treat or prevent septic dissemination. For fracture-related infections with low virulence, prolonged antimicrobial therapy or exchange of an indwelling implant might be beneficial owing to slower growth and persistence capacity.


Asunto(s)
Fracturas del Fémur , Osteomielitis , Infecciones Estafilocócicas , Animales , Femenino , Ratones , Citocinas , Modelos Animales de Enfermedad , Fracturas del Fémur/cirugía , Osteomielitis/microbiología , Infecciones Estafilocócicas/microbiología , Staphylococcus aureus/fisiología
6.
Int Orthop ; 47(4): 1079-1087, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36749374

RESUMEN

BACKGROUND/PURPOSE: Pubic ramus fractures account for the most common types of pelvic fractures. The standard surgical approach for superior pubic ramus fractures (SPRF) is a minimally invasive percutaneous screw fixation. However, percutaneous closed reduction and internal fixation of anterior pelvic ring injuries have high failure rates of up to 15%. The aim of this biomechanical study was to evaluate the stability of SPRF following stabilization with retrograde placed cannulated compression headless screw (CCHS) versus conventional fully and partially threaded screws in an artificial pelvic bone model. METHODS: SPRF type II as described by Nakatani et al. was created by means of osteotomies in eighteen anatomical composite hemi-pelvises. Specimens were stratified into three groups of six specimens each (n = 6) for fixation with either a 7.3 mm partially threaded cannulated screw (group RST), a 7.3 mm fully threaded cannulated screw (group RSV), or a 7.5 mm partially threaded cannulated CCHS (group CCS). Each hemi-pelvic specimen was tested in an inverted upright standing position under progressively increasing cyclic axial loading. The peak load, starting at 200 N, was monotonically increased at a rate of 0.1 N/cycle until 10 mm actuator displacement. RESULTS: Total and torsional displacement were associated with higher values for RST versus CCS and RSV, with significant differences between RST and CCS for both these parameters (p ≤ 0.033). The differences between RST and RSV were significant for total displacement (p = 0.020), and a trend toward significance for torsional displacement (p = 0.061) was observed. For both failure criteria 2 mm total displacement and 5° torsional displacement, CCS was associated with significantly higher number of cycles compared to RST (p ≤ 0.040). CONCLUSION: CCHS fixation presented predominantly superior stability to the standard surgical treatment and could therefore be a possible alternative implant for retrograde SPRF screw fixation, whereas partially threaded screws in group RST were associated with inferior biomechanical stability.


Asunto(s)
Fracturas Óseas , Huesos Pélvicos , Humanos , Tornillos Óseos , Fracturas Óseas/cirugía , Fijación Interna de Fracturas , Hueso Púbico , Huesos Pélvicos/cirugía , Huesos Pélvicos/lesiones , Fenómenos Biomecánicos
7.
Medicina (Kaunas) ; 59(9)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37763723

RESUMEN

Background and Objectives: Unstable proximal humerus fractures (PHFs) with metaphyseal defects-weakening the osteosynthesis construct-are challenging to treat. A new augmentation technique of plated complex PHFs with metaphyseal defects was recently introduced in the clinical practice. This biomechanical study aimed to analyze the stability of plated unstable PHFs augmented via implementation of this technique versus no augmentation. Materials and Methods: Three-part AO/OTA 11-B1.1 unstable PHFs with metaphyseal defects were created in sixteen paired human cadaveric humeri (average donor age 76 years, range 66-92 years), pairwise assigned to two groups for locked plate fixation with identical implant configuration. In one of the groups, six-milliliter polymethylmethacrylate bone cement with medium viscosity (seven minutes after mixing) was placed manually through the lateral window in the defect of the humerus head after its anatomical reduction to the shaft and prior to the anatomical reduction of the greater tuberosity fragment. All specimens were tested biomechanically in a 25° adduction, applying progressively increasing cyclic loading at 2 Hz until failure. Interfragmentary movements were monitored by motion tracking and X-ray imaging. Results: Initial stiffness was not significantly different between the groups, p = 0.467. Varus deformation of the humerus head fragment, fracture displacement at the medial humerus head aspect, and proximal screw migration and cut-out were significantly smaller in the augmented group after 2000, 4000, 6000, 8000 and 10,000 cycles, p ≤ 0.019. Cycles to 5° varus deformation of the humerus head fragment-set as a clinically relevant failure criterion-and failure load were significantly higher in the augmented group, p = 0.018. Conclusions: From a biomechanical standpoint, augmentation with polymethylmethacrylate bone cement placed in the metaphyseal humerus head defect of plated unstable PHFs considerably enhances fixation stability and can reduce the risk of postoperative complications.

8.
J Shoulder Elbow Surg ; 31(1): 192-200, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34298147

RESUMEN

BACKGROUND: Optimal treatment options for proximal humerus fractures (PHFs) are still debated because of persisting high fixation failure rates experienced with locking plates. Optimization of the implants and development of patient-specific designs may help improve the primary fixation stability of PHFs and reduce the rate of mechanical failures. Optimizing the screw orientations in locking plates has shown promising results; however, the potential benefit of subject-specific designs has not been explored yet. The purpose of this study was to evaluate by means of finite element (FE) analyses whether subject-specific optimization of the screw orientations in a fixed-angle locking plate can reduce the predicted cutout failure risk in unstable 3-part fractures. METHODS: FE models of 19 low-density proximal humeri were generated from high-resolution computed tomographic images using a previously developed and validated computational osteosynthesis framework. The specimens were virtually osteotomized to simulate unstable malreduced 3-part fractures and fixed with the PHILOS plates using 6 proximal locking screws. The average principal compressive strain in cylindrical bone regions around the screw tips-a biomechanically validated surrogate for the risk of cyclic screw cutout failure-was defined as the main outcome measure. The angles of the 6 proximal locking screws were optimized via parametric analysis for each humerus individually, resulting in subject-specific screw orientations (SSO). The average peri-implant strains of the SSO were statistically compared with the previously reported cohort-specific (CSO) and original PHILOS screw orientations (PSO) for females vs. males. RESULTS: The optimized SSO significantly reduced the peri-screw bone strain vs. CSO (6.8% ± 4.0%, P = .006) and PSO (25.24% ± 7.93%, P < .001), indicating lower cutout risk for subject-specific configurations. The benefits of SSO vs. PSO were significantly higher for women than men. CONCLUSION: The findings of this study suggest that subject-specific optimization of the locking screw orientations could lead to lower cutout risk and improved PHF fixation. These computer simulation results require biomechanical and clinical corroboration. Further studies are needed to evaluate whether the potential benefit in stability could justify the increased efforts related to implementation of individualized implants. Nevertheless, computational exploration of the biomechanical factors influencing the outcome of fracture fixations could help better understand the fixation failures and reduce their incidence.


Asunto(s)
Fracturas del Hombro , Fenómenos Biomecánicos , Placas Óseas , Simulación por Computador , Femenino , Fijación Interna de Fracturas , Humanos , Húmero , Masculino , Fracturas del Hombro/diagnóstico por imagen , Fracturas del Hombro/cirugía
9.
Calcif Tissue Int ; 108(5): 654-666, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33388801

RESUMEN

The probiotic Bifidobacterium longum subsp. longum 35624® (B. longum 35624®), with its surface exopolysaccharide (EPS624), has previously been demonstrated to induce immunoregulatory responses in the host and may, therefore, be a novel approach to prevent bone loss in inflammatory conditions such as post-menopausal osteoporosis (PMO). The aim of this study was to investigate the effect of EPS624 on osteoclast and osteoblast differentiation and to assess the potential of B. longum 35624® to prevent bone loss in vivo. In vitro cell assays were used to assess the impact of EPS624 on osteoclast and osteoblast differentiation. The potential of two probiotic B. longum 35624® strains, including an EPS-deficient strain, for preventing ovariectomy (Ovx)-induced bone loss was assessed in a murine model. EPS624 prevented osteoclast formation from murine bone marrow precursors under both normal and TNFα-induced inflammatory conditions and modestly increased mineralized matrix deposition in osteogenic cell cultures. However, in the presence of an anti-TLR2 blocking antibody, or in MyD88-/- osteoclast precursors, the inhibitory effect of EPS624 on osteoclast formation was diminished or completely prevented, respectively. Moreover, EPS624 induced IL-10 production in osteoclast precursors in a TLR2-dependent manner, although IL-10 was dispensable in the EPS624-mediated inhibition of osteoclast formation. In addition, EPS624-producing B. longum 35624® partially prevented bone loss in Ovx mice when administered by oral gavage. This study introduced EPS624 as a potential anti-resorptive therapy, although optimal in vivo delivery of the probiotic strain for treating low-grade inflammatory diseases such as PMO remains to be determined.


Asunto(s)
Bifidobacterium longum , Animales , Bifidobacterium , Femenino , Ratones , Osteoclastos , Receptor Toll-Like 2
10.
Mediators Inflamm ; 2021: 8817421, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34924815

RESUMEN

Short-chain fatty acids (SCFAs) produced by the gut microbiota have previously been demonstrated to play a role in numerous chronic inflammatory diseases and to be key mediators in the gut-bone signaling axis. However, the role of SCFAs in bone fracture healing and its impact on systemic inflammation during the regeneration process has not been extensively investigated yet. The aim of this study was to first determine the effects of the SCFA butyrate on key cells involved in fracture healing in vitro, namely, osteoclasts and mesenchymal stromal cells (MSCs), and second, to assess if butyrate supplementation or antibiotic therapy impacts bone healing, systemic immune status, and inflammation levels in a murine osteotomy model. Butyrate significantly reduced osteoclast formation and resorption activity in a dose-dependent manner and displayed a trend for increased calcium deposits in MSC cultures. Numerous genes associated with osteoclast differentiation were differentially expressed in osteoclast precursor cells upon butyrate exposure. In vivo, antibiotic-treated mice showed reduced SCFA levels in the cecum, as well as a distinct gut microbiome composition. Furthermore, circulating proinflammatory TNFα, IL-17a, and IL-17f levels, and bone preserving osteoprotegerin (OPG), were increased in antibiotic-treated mice compared to controls. Antibiotic-treated mice also displayed a trend towards delayed bone healing as revealed by reduced mineral apposition at the defect site and higher circulating levels of the bone turnover marker PINP. Butyrate supplementation resulted in a lower abundance of monocyte/macrophages in the bone marrow, as well as reduced circulating proinflammatory IL-6 levels compared to antibiotic- and control-treated mice. In conclusion, this study supports our hypothesis that SCFAs, in particular butyrate, are important contributors to successful bone healing by modulating key cells involved in fracture healing as well as systemic inflammation and immune responses.


Asunto(s)
Antibacterianos/farmacología , Butiratos/farmacología , Curación de Fractura/efectos de los fármacos , Inflamación/etiología , Osteoclastos/efectos de los fármacos , Animales , Diferenciación Celular/efectos de los fármacos , Células Cultivadas , Citocinas/análisis , Ácidos Grasos Volátiles/farmacología , Curación de Fractura/fisiología , Microbioma Gastrointestinal/efectos de los fármacos , Humanos , Mediadores de Inflamación/análisis , Levofloxacino/farmacología , Masculino , Ratones , Ratones Endogámicos C57BL , Osteoclastos/citología , Osteotomía , Rifampin/farmacología
11.
Medicina (Kaunas) ; 57(12)2021 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-34946313

RESUMEN

Background and Objectives: The stability of the pelvic ring mainly depends on the integrity of its posterior part. Percutaneous sacroiliac (SI) screws are widely implanted as standard of care treatment. The main risk factors for their fixation failure are related to vertical shear or transforaminal sacral fractures. The aim of this study was to compare the biomechanical performance of fixations using one (Group 1) or two (Group 2) standard SI screws versus one SI screw with bone cement augmentation (Group 3). Materials and Methods: Unstable fractures of the pelvic ring (AO/OTA 61-C1.3, FFP IIc) were simulated in 21 artificial pelvises by means of vertical osteotomies in the ipsilateral anterior and posterior pelvic ring. A supra-acetabular external fixator was applied to address the anterior fracture. All specimens were tested under progressively increasing cyclic loading until failure, with monitoring by means of motion tracking. Fracture site displacement and cycles to failure were evaluated. Results: Fracture displacement after 500 cycles was lowest in Group 3 (0.76 cm [0.30] (median [interquartile range, IQR])) followed by Group 1 (1.42 cm, [0.21]) and Group 2 (1.42 cm [1.66]), with significant differences between Groups 1 and 3, p = 0.04. Fracture displacement after 1000 cycles was significantly lower in Group 3 (1.15 cm [0.37]) compared to both Group 1 (2.19 cm [2.39]) and Group 2 (2.23 cm [3.65]), p ≤ 0.04. Cycles to failure (Group 1: 3930 ± 890 (mean ± standard deviation), Group 2: 3676 ± 348, Group 3: 3764 ± 645) did not differ significantly between the groups, p = 0.79. Conclusions: In our biomechanical setup cement augmentation of one SI screw resulted in significantly less displacement compared to the use of one or two SI screws. However, the number of cycles to failure was not significantly different between the groups. Cement augmentation of one SI screw seems to be a useful treatment option for posterior pelvic ring fixation, especially in osteoporotic bone.


Asunto(s)
Fracturas Óseas , Fracturas de la Columna Vertebral , Fenómenos Biomecánicos , Cementos para Huesos/uso terapéutico , Tornillos Óseos , Fijación Interna de Fracturas , Fracturas Óseas/cirugía , Humanos , Pelvis/cirugía
12.
Infect Immun ; 88(11)2020 10 19.
Artículo en Inglés | MEDLINE | ID: mdl-32817328

RESUMEN

Staphylococcus aureus is a prominent human pathogen in bone and soft-tissue infections. Pathophysiology involves abscess formation, which consists of central staphylococcal abscess communities (SACs), surrounded by a fibrin pseudocapsule and infiltrating immune cells. Protection against the ingress of immune cells such as neutrophils, or tolerance to antibiotics, remains largely unknown for SACs and is limited by the lack of availability of in vitro models. We describe a three-dimensional in vitro model of SACs grown in a human plasma-supplemented collagen gel. The in vitro SACs reached their maximum size by 24 h and elaborated a fibrin pseudocapsule, as confirmed by electron and immunofluorescence microscopy. The in vitro SACs tolerated 100× the MIC of gentamicin alone and in combination with rifampin, while planktonic controls and mechanically dispersed SACs were efficiently killed. To simulate a host response, SACs were exposed to differentiated PLB-985 neutrophil-like (dPLB) cells and to primary human neutrophils at an early stage of SAC formation or after maturation at 24 h. Both cell types were unable to clear mature in vitro SACs, but dPLB cells prevented SAC growth upon early exposure before pseudocapsule maturation. Neutrophil exposure after plasmin pretreatment of the SACs resulted in a significant decrease in the number of bacteria within the SACs. The in vitro SAC model mimics key in vivo features, offers a new tool to study host-pathogen interactions and drug efficacy assessment, and has revealed the functionality of the S. aureus pseudocapsule in protecting the bacteria from host phagocytic responses and antibiotics.


Asunto(s)
Absceso/inmunología , Absceso/microbiología , Farmacorresistencia Microbiana/fisiología , Infecciones Estafilocócicas/inmunología , Humanos , Técnicas In Vitro , Neutrófilos/inmunología , Staphylococcus aureus/fisiología
13.
Connect Tissue Res ; 61(3-4): 304-321, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31556329

RESUMEN

Low back pain is the leading cause of disability worldwide and in many patients the source of pain can be attributed to pathological changes within the intervertebral disc (IVD). As present treatment options fail to address the underlying biological problem, novel therapies are currently subject to intense research. The physiologic IVD microenvironment features a highly complex interaction of biochemical and mechanical factors influencing cell metabolism and extracellular matrix turnover and is therefore difficult to simulate for research purposes on IVD pathology. The first whole organ culture models were not able to sufficiently replicate human in vivo conditions as mechanical loading, the predominant way of IVD nutrient supply and waste exchange, remained disregarded. To mimic the unique IVD niche more realistically, whole organ culture bioreactors have been developed, allowing for dynamic loading of IVDs and nutrient exchange. Recent advancements on bioreactor systems have facilitated whole organ culture of various IVDs for extended periods. IVD organ culture bioreactors have the potential to bridge the gap between in vitro and in vivo systems and thus may give valuable insights on IVD pathology and/or potential novel treatment approaches if the respective model is adjusted according to a well-defined research question. In this review, we outline the potential of currently utilized IVD bioreactor systems and present suggestions for further developments to more reliably investigate IVD biology and novel treatment approaches.


Asunto(s)
Reactores Biológicos , Degeneración del Disco Intervertebral , Disco Intervertebral , Modelos Biológicos , Regeneración , Técnicas de Cultivo de Tejidos , Animales , Humanos , Disco Intervertebral/patología , Disco Intervertebral/fisiología , Degeneración del Disco Intervertebral/metabolismo , Degeneración del Disco Intervertebral/patología
14.
Arch Orthop Trauma Surg ; 140(8): 1013-1027, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31659475

RESUMEN

Fracture-related infection (FRI) remains a challenging complication that creates a heavy burden for orthopaedic trauma patients, their families and treating physicians, as well as for healthcare systems. Standardization of the diagnosis of FRI has been poor, which made the undertaking and comparison of studies difficult. Recently, a consensus definition based on diagnostic criteria for FRI was published. As a well-established diagnosis is the first step in the treatment process of FRI, such a definition should not only improve the quality of published reports but also daily clinical practice. The FRI consensus group recently developed guidelines to standardize treatment pathways and outcome measures. At the center of these recommendations was the implementation of a multidisciplinary team (MDT) approach. If such a team is not available, it is recommended to refer complex cases to specialized centers where a MDT is available and physicians are experienced with the treatment of FRI. This should lead to appropriate use of antimicrobials and standardization of surgical strategies. Furthermore, an MDT could play an important role in host optimization. Overall two main surgical concepts are considered, based on the fact that fracture fixation devices primarily target fracture consolidation and can be removed after healing, in contrast to periprosthetic joint infection were the implant is permanent. The first concept consists of implant retention and the second consists of implant removal (healed fracture) or implant exchange (unhealed fracture). In both cases, deep tissue sampling for microbiological examination is mandatory. Key aspects of the surgical management of FRI are a thorough debridement, irrigation with normal saline, fracture stability, dead space management and adequate soft tissue coverage. The use of local antimicrobials needs to be strongly considered. In case of FRI, empiric broad-spectrum antibiotic therapy should be started after tissue sampling. Thereafter, this needs to be adapted according to culture results as soon as possible. Finally, a minimum follow-up of 12 months after cessation of therapy is recommended. Standardized patient outcome measures purely focusing on FRI are currently not available but the patient-reported outcomes measurement information system (PROMIS) seems to be the preferred tool to assess the patients' short and long-term outcome. This review summarizes the current general principles which should be considered during the whole treatment process of patients with FRI based on recommendations from the FRI Consensus Group.Level of evidence: Level V.


Asunto(s)
Infecciones Bacterianas , Fracturas Óseas , Infección de la Herida Quirúrgica , Antibacterianos/uso terapéutico , Consenso , Fijación Interna de Fracturas/efectos adversos , Fracturas Óseas/complicaciones , Fracturas Óseas/cirugía , Humanos , Guías de Práctica Clínica como Asunto
15.
J Foot Ankle Surg ; 59(6): 1156-1161, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32958353

RESUMEN

Although the literature describes a variety of reconstructive techniques for the syndesmosis, only few studies offer comparative data. Therefore, the authors compared 2 different ligament repair techniques for the syndesmosis. Sixteen paired fresh-frozen human cadaveric lower limbs were embedded in polymethyl methacrylate mid-calf and placed in a custom-made weightbearing simulation frame. Computed tomography scans of each limb were obtained in a simulated foot-flat loading (75N) and single-leg stance (700N) in 5 different foot positions (previously reported data). One of each pair was then reconstructed via 1 of 2 methods: a free medial Achilles tendon autograft or a long peroneal tendon ligament repair. The specimens were rescanned, compared with their respective intact states and directly with each other. Measurements of fibular diastasis, rotation, anteroposterior translation, mediolateral translation, and fibular shortening were performed on the axial cuts of the computed tomography scans, 1 cm proximal to the roof of the plafond. There was no significant difference in fibular positioning with direct comparison of the reconstructions. Comparisons with their respective intact states, however, showed differences in their abilities to control reduction, most notably in the externally rotated and dorsiflexed positions of the foot. Neither reconstruction was clearly superior in restoring physiologic conditions. Only with a comparison of each technique to its respective intact state were differences between the techniques revealed, a benefit of this particular testing method.


Asunto(s)
Traumatismos del Tobillo , Ligamentos Laterales del Tobillo , Traumatismos del Tobillo/diagnóstico por imagen , Traumatismos del Tobillo/cirugía , Cadáver , Humanos , Tomografía Computarizada por Rayos X , Soporte de Peso
16.
J Shoulder Elbow Surg ; 28(9): 1816-1823, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31036421

RESUMEN

BACKGROUND: Proximal humeral fractures occur frequently, with fixed angle locking plates often being used for their treatment. No current quantitative evidence for the effect of different screw configurations exists, and the large number of variations makes biomechanical testing prohibitive. Therefore, we used an established and validated finite element osteosynthesis test kit to quantify the effect of variations in screw configuration on predicted failure risk of PHILOS plate fixation for unstable proximal humerus fractures. METHODS: Twenty-six low-density humerus models were osteotomized to create malreduced unstable 3-part fractures that were virtually fixed with PHILOS plates. Twelve screw configurations were simulated: 6 using 2 screw rows, 4 using 3 rows, and 1 with either 8 or 9 screws. Three physiological loading cases were modeled and an established finite element analysis methodology was used. The average peri-screw bone strain, previously demonstrated to predict fatigue cutout failure, was used to compare the different configurations. RESULTS: Significant differences in peri-screw strains, and thus predicted failure risk, were seen with different combinations. The 9-screw configuration demonstrated the lowest peri-screw strains. Fewer screw constructs showed lower strains when placed further apart. The calcar screws (row E) significantly (P < .001) reduced fixation failure risk. CONCLUSION: Screw configurations significantly impact predicted cutout failure risk for locking plate fixations of unstable proximal humerus fractures in low-density bone. Although requiring clinical corroboration, the result of this study suggests that additional screws reduce peri-screw strains, the distance between them should be maximized whenever possible and the calcar screws should be used.


Asunto(s)
Placas Óseas , Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Fracturas del Hombro/cirugía , Fenómenos Biomecánicos , Epífisis/lesiones , Epífisis/cirugía , Análisis de Falla de Equipo , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Falla de Prótesis
17.
Arch Orthop Trauma Surg ; 139(8): 1069-1074, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30895465

RESUMEN

BACKGROUND: The aim of this study was to identify the effect of screw length on predictions of fixation failure in three-part proximal humeral fractures using a finite element-based osteosynthesis modelling toolkit. METHODS: A mal-reduced unstable three-part AO/OTA 11-B3.2 fracture with medial comminution was simulated in forty-two digitally processed proximal humeri covering a spectrum of bone densities and fixed with the PHILOS plate using three distal and six proximal locking screws. Four test groups were generated based on the screw tip to joint surface distance (TJD), with all proximal screws being shortened from 4 mm TJD to be 8, 12 or 16 mm TJD. Average bone strains around the screw tips, correlating with biomechanical cyclic cut-out-type failure, were evaluated in three physiological loading protocols representing simple shoulder motions. Six further groups were tested, where five of the proximal screws were inserted to 4 mm TJD and the sixth screw to 8 mm TJD. RESULTS: Exponential increases in the predicted risk of fixation failure were seen with increased tip-to-joint distances (p < 0.001). When one of the proximal screws was placed 8 mm from the joint, with the remaining five at 4 mm distance, significant increases (p < 0.001) were registered in the strains around the screw tips in all except the two superior screws. This effect was maximal around the calcar screws (p < 0.001) and for lower density samples (p < 0.001). CONCLUSIONS: These results suggest that longer screws provide reduced risk of cut-out failure, i.e. distalisation and/or varisation of the head fragment, and thus may decrease failure rates in proximal humeral fractures treated with angular stable plates. These findings require clinical corroboration and further studies to investigate the risk of screw perforation.


Asunto(s)
Tornillos Óseos , Simulación por Computador , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/cirugía , Anciano , Anciano de 80 o más Años , Placas Óseas , Femenino , Fijación Interna de Fracturas/instrumentación , Fracturas Conminutas/diagnóstico por imagen , Fracturas Conminutas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Fracturas del Hombro/diagnóstico por imagen , Tomografía Computarizada por Rayos X
18.
J Foot Ankle Surg ; 58(4): 734-738, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31256900

RESUMEN

Syndesmotic injuries are quite common, but accurate diagnosis and treatment can be difficult, in part because of individual anatomic variation and complex movements of the fibula in the incisura. The current cadaveric study was designed to investigate changes in the position of the fibula in the incisura during simulated weightbearing in different foot positions and with sequential sectioning of syndesmotic and deltoid ligaments. Sixteen paired, fresh-frozen cadaveric limbs were embedded in polymethylmethacrylate mid-calf and placed in a weightbearing simulation frame. Computed tomography scans were obtained while the legs were in a simulated foot-flat position (75 N) and single-leg stance (700 N) in 5 foot positions: neutral, 15° external rotation, 15° internal rotation, 20° dorsiflexion, and 20° plantar flexion. The anterior-inferior tibiofibular ligament, posterior tibiofibular ligament complex, deltoid, and interosseous membranes were sectioned sequentially and rescanned. Measurements of fibular diastasis, rotation, anterior-posterior and medial-lateral translation, and fibular shortening were performed. The most destructive state resulted in the largest displacement at the syndesmosis. The degree of subluxation in all ligament states was dependent on the foot position. External rotation created statistically significant displacement at all levels of injury. There were no significant differences between sides of the same donor. Our data demonstrate the importance of foot position in reduction at the syndesmosis under weightbearing. The current ex vivo model could be used to evaluate other aspects of this injury or the value of reconstructive techniques in the future.


Asunto(s)
Traumatismos del Tobillo/diagnóstico por imagen , Ligamentos Colaterales/anatomía & histología , Peroné/anatomía & histología , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Traumatismos del Tobillo/patología , Cadáver , Ligamentos Colaterales/diagnóstico por imagen , Femenino , Peroné/diagnóstico por imagen , Peroné/lesiones , Peroné/patología , Humanos , Inestabilidad de la Articulación , Ligamentos Laterales del Tobillo/anatomía & histología , Ligamentos Laterales del Tobillo/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Soporte de Peso
19.
Int J Mol Sci ; 19(7)2018 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-29966376

RESUMEN

The osteocyte network inside the bone matrix is of functional importance and osteocyte cell death is a characteristic feature of pathological bone diseases. Osteocytes have emerged as key regulators of bone tissue maintenance, yet maintaining their phenotype during in vitro culture remains challenging. A 3D co-culture system for osteocytes with osteoblasts was recently presented, enabling the determination of more physiological effects of growth factors on cells in vitro. MLO-Y4 cells were embedded within a type I collagen gel and cultured in the presence of surface MG-63 cells. Co-culture was performed in the presence or absence of TGFß3. Gene expression by quantitative PCR, protein expression by fluorescent immunohistochemistry and cell viability tests were performed. The 3D co-culture induced cell differentiation of MG-63 cells seen by increased type I collagen and osteocalcin mRNA expression. TGFβ3 maintained osteocyte differentiation of MLO-Y4 cells during co-culture as determined by stable E11 and osteocalcin mRNA expression till day 4. Interestingly, most of the effects of TGFß3 on co-cultured cells were serum-dependent. Also, TGFß3 reduced cell death of 3D co-cultured MLO-Y4 cells in a serum-dependent manner. This study shows that 3D co-culture upregulates differentiation of MG-63 cells to a more mature osteoblast-like phenotype; while the addition of TGFß3 maintained the characteristic MLO-Y4 osteocyte-like phenotype and viability in a serum-dependent manner.


Asunto(s)
Técnicas de Cocultivo/métodos , Osteoblastos/efectos de los fármacos , Osteoblastos/metabolismo , Factor de Crecimiento Transformador beta/farmacología , Animales , Muerte Celular/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Inmunohistoquímica , Etiquetado Corte-Fin in Situ , Ratones , Osteocitos/efectos de los fármacos , Osteocitos/metabolismo
20.
Arch Orthop Trauma Surg ; 138(7): 971-977, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29700604

RESUMEN

INTRODUCTION: Patients suffering from osteoporosis-associated fragility fractures of the sacrum (FFS; also termed sacral insufficiency fractures) are increasingly observed. They have typical fracture patterns with fracture lines located in the sacral ala. When treating these patients operatively, iliosacral screw loosening is not uncommon. We aimed to study the sacral bone mass in patients presenting with a FFS using 3D statistical models. MATERIALS AND METHODS: 3D models of averaged Hounsfield units (HU) were generated based on CT scans from 13 patients with a unilateral FFS (mean age 79.6 years; 11 females, 2 males). The control group without fractures consisted of 28 males and 32 females (mean age of 68.3 years). A virtual bone probe along the trans-sacral corridors S1 and S2 was taken. RESULTS: The bone mass distribution in the fractured sacra was similar to the control group, however, with overall lower HU. Large zones of negative HU were located in the sacral ala. In the fractured sacra, the HU in the sacral ala was significantly lower on the non-injured side when comparing to the fractured side (p < 0.001) as well as compared to the non-fractured group (p < 0.001). Low bone mass was observed in sacral body S1 (40 HU) and S2 (20 HU). CONCLUSIONS: The extensive area of negative HU may explain the fracture location in the sacral ala. The low HU in the sacral bodies advocates the use of trans-sacral implants or augmented iliosacral screws to enhance the strength of fracture fixation. The increased HU in the fractured ala could be explained by fracture-asssociated hemorrhage and can be used as a diagnostic tool.


Asunto(s)
Fracturas Osteoporóticas/diagnóstico por imagen , Sacro/lesiones , Fracturas de la Columna Vertebral/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Densidad Ósea , Tornillos Óseos , Femenino , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Fracturas Osteoporóticas/cirugía , Estudios Retrospectivos , Sacro/diagnóstico por imagen , Sacro/cirugía , Fracturas de la Columna Vertebral/cirugía , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA