Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38502349

RESUMEN

PURPOSE: To assess incidence, risk factors, and treatment of retroprosthetic membrane (RPM) formation in eyes following Boston keratoprosthesis (Kpro) implantation and their correlation with glaucoma drainage device placement (GDD). METHODS: A retrospective review was performed on eyes that underwent Kpro type I or II implantation between 2005 and 2020 at a tertiary academic center. Multiple variables were collected including preoperative characteristics, presence of RPM, management of RPM, and outcomes including corrected visual acuity (VA). A Fischer's exact test was used to evaluate the significance of risk factors of RPM formation and an odds ratio was calculated for each possible risk factor. A Mann-Whitney U test was used to evaluate comparisons between outcomes and qualitative analyses. RESULTS: Of the 87 eyes identified, 37 (43%) developed an RPM within an average of 1.5 years (range, 31 days-7.5 years) following Kpro implantation. Mean follow-up duration was 4.3 years. Eyes that developed RPM had significantly worse preoperative VA compared to those that did not (logMAR 2.55 vs. 2.28, p = 0.022). The mean number of prior penetrating keratoplasty procedures trended higher in eyes that developed RPM (2.46 vs. 2.18, p = 0.44) but was not significant. GDD placement after Kpro implantation was associated with an increased risk of RPM formation (RR = 1.69 p = 0.026). Of the 37 eyes that developed an RPM following Kpro, 17 (47%) were treated with Nd:YAG laser, and four of those 17 (21%) also underwent pars plana vitrectomy (PPV). Seven of 37 eyes (19%) underwent PPV without Nd:YAG. Comparisons between RPM occurrence and final VA were not significant. CONCLUSIONS: The incidence of RPM formation following Kpro implantation was 43%. Eyes that developed RPM had significantly worse preoperative VA. GDD placement after Kpro implantation increased the risk of developing RPM. Final VA and occurrence of RPM were not significantly different between the Nd:YAG and PPV treatment groups.

2.
Retina ; 43(11): 1996-2002, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37490751

RESUMEN

PURPOSE: To compare features of endogenous endophthalmitis associated with injection drug use (IDU) to endogenous endophthalmitis from other etiologies. METHODS: The authors retrospectively collected data on patients with endogenous endophthalmitis due to IDU or other causes from three academic tertiary care centers over a six-year period. Differences in presenting characteristics, culture results, treatment, and visual acuity were compared between groups. RESULTS: Thirty-eight patients (34%) had IDU-associated endogenous endophthalmitis while 75 patients (67%) had endogenous endophthalmitis from other causes. Compared with patients in the non-IDU group, IDU patients were significantly younger, more frequently male, had longer duration of symptoms at diagnosis, and were less likely to have bilateral disease ( P < 0.05 for all). Injection drug use patients were less likely to have a systemic infection source identified (29% vs. 71%, P < 0.001) or have positive cultures (47% vs. 80%, P < 0.001). The IDU group was less likely to be admitted to the hospital (71% vs. 92%, P = 0.005) and less likely to receive treatment with intravenous antimicrobials (55% vs. 83%, P = 0.003). Visual acuity did not significantly differ between groups. CONCLUSION: Endophthalmitis related to IDU presents in younger patients with less comorbidities and frequently without positive cultures or an identifiable systemic source; therefore, a high index of suspicion is needed to identify this disease.


Asunto(s)
Endoftalmitis , Infecciones Bacterianas del Ojo , Humanos , Masculino , Estudios Retrospectivos , Vitrectomía , Endoftalmitis/diagnóstico , Endoftalmitis/tratamiento farmacológico , Endoftalmitis/epidemiología , Agudeza Visual , Antibacterianos/uso terapéutico , Infecciones Bacterianas del Ojo/diagnóstico , Infecciones Bacterianas del Ojo/tratamiento farmacológico , Infecciones Bacterianas del Ojo/epidemiología
3.
Curr Opin Ophthalmol ; 33(5): 425-431, 2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-35916570

RESUMEN

PURPOSE OF REVIEW: Artificial intelligence tools are being rapidly integrated into clinical environments and may soon be incorporated into dementia diagnostic paradigms. A comprehensive review of emerging trends will allow physicians and other healthcare providers to better anticipate and understand these powerful tools. RECENT FINDINGS: Machine learning models that utilize cerebral biomarkers are demonstrably effective for dementia identification and prediction; however, cerebral biomarkers are relatively expensive and not widely available. As eye images harbor several ophthalmic biomarkers that mirror the state of the brain and can be clinically observed with routine imaging, eye-based machine learning models are an emerging area, with efficacy comparable with cerebral-based machine learning models. Emerging machine learning architectures like recurrent, convolutional, and partially pretrained neural networks have proven to be promising frontiers for feature extraction and classification with ocular biomarkers. SUMMARY: Machine learning models that can accurately distinguish those with symptomatic Alzheimer's dementia from those with mild cognitive impairment and normal cognition as well as predict progressive disease using relatively inexpensive and accessible ocular imaging inputs are impactful tools for the diagnosis and risk stratification of Alzheimer's dementia continuum. If these machine learning models can be incorporated into clinical care, they may simplify diagnostic efforts. Recent advancements in ocular-based machine learning efforts are promising steps forward.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Enfermedad de Alzheimer/diagnóstico , Inteligencia Artificial , Biomarcadores , Disfunción Cognitiva/diagnóstico , Humanos , Aprendizaje Automático
4.
Retina ; 42(2): 321-327, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34483314

RESUMEN

PURPOSE: To describe the presentation, microbiology, management, and prognosis of eyes with endophthalmitis after Boston keratoprosthesis implantation. METHODS: Retrospective case series with history, diagnostics, management, and outcomes data in endophthalmitis after keratoprosthesis implantation presenting to a tertiary center between 2009 and 2020. RESULTS: Of 137 keratoprosthesis-implanted eyes, 7 eyes of 7 patients (5%) developed endophthalmitis. On presentation, 6 (86%) reported decreased visual acuity, and only 1 (14%) reported pain. Peripheral corneal ulcers were present in 2 eyes (29%). Seidel testing was negative in all cases. Six eyes (86%) had retroprosthetic membranes. One (14%) underwent initial pars plana vitrectomy with mechanical vitreous biopsy, whereas 6 (86%) received a needle vitreous tap-half of which were dry. Organisms were isolated after vitreous tap in two eyes: Streptococcus intermedius and Mycobacterium abscessus. The mean visual acuity preendophthalmitis, at presentation, and at 6 months were 20/267, 20/5,944, and 20/734, respectively. The visual acuity improved 9.08 ± 11.78 Early Treatment Diabetic Retinopathy Study lines from presentation to 6 months. Six-month visual acuity was correlated with preendophthalmitis visual acuity (r = 0.92, P = 0.003) but not presenting visual acuity (P = 0.838). CONCLUSION: Visual acuity at 6 months is correlated with preendophthalmitis visual acuity, not presenting visual acuity. Endophthalmitis should be considered in the differential diagnosis of painless intraocular inflammation any time after keratoprosthesis implantation, even if Seidel negative.


Asunto(s)
Órganos Artificiales , Córnea , Endoftalmitis/fisiopatología , Infecciones Bacterianas del Ojo/fisiopatología , Complicaciones Posoperatorias , Agudeza Visual/fisiología , Anciano , Antibacterianos/uso terapéutico , Terapia Combinada , Combinación de Medicamentos , Endoftalmitis/microbiología , Endoftalmitis/terapia , Infecciones Bacterianas del Ojo/microbiología , Infecciones Bacterianas del Ojo/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones por Mycobacterium no Tuberculosas/microbiología , Infecciones por Mycobacterium no Tuberculosas/fisiopatología , Infecciones por Mycobacterium no Tuberculosas/terapia , Mycobacterium abscessus/aislamiento & purificación , Prótesis e Implantes , Implantación de Prótesis , Estudios Retrospectivos , Infecciones Estreptocócicas/microbiología , Infecciones Estreptocócicas/fisiopatología , Infecciones Estreptocócicas/terapia , Streptococcus intermedius/aislamiento & purificación , Vitrectomía , Cuerpo Vítreo/microbiología
5.
Retina ; 42(7): 1338-1346, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35723922

RESUMEN

PURPOSE: To assess retinal microvascular alterations in individuals with amnestic mild cognitive impairment (MCI) and nonamnestic MCI. METHODS: One hundred twelve eyes of 59 amnestic MCI participants, 32 eyes of 17 nonamnestic MCI participants, and 111 eyes of 56 controls with normal cognition were included. Optical coherence tomography angiography vessel density and perfusion density in the Early Treatment Diabetic Retinopathy Study 3-mm circle and ring were assessed. Retinal thickness parameters including retinal nerve fiber layer thickness, ganglion cell-inner plexiform layer thickness, central subfield thickness, and subfoveal choroidal thickness were also analyzed. Multivariable generalized estimating equations were used for statistical analysis. RESULTS: Perfusion density in the 3-mm inner ring was significantly lower in amnestic MCI patients when compared with nonamnestic MCI participants (0.29 ± 0.03 vs. 0.34 ± 0.09, P = 0.025) and controls with normal cognition (0.29 ± 0.03 vs. 0.39 ± 0.02, P < 0.001), after adjustment for age and sex as covariates. Vessel density, retinal nerve fiber layer thickness, ganglion cell-inner plexiform layer thickness, central subfield thickness, and subfoveal choroidal thickness did not differ among or between diagnostic groups. CONCLUSION: Perfusion density was significantly reduced in individuals with amnestic MCI, compared with those with nonamnestic MCI and controls with normal cognition.


Asunto(s)
Disfunción Cognitiva , Tomografía de Coherencia Óptica , Angiografía , Disfunción Cognitiva/diagnóstico , Humanos , Fibras Nerviosas , Células Ganglionares de la Retina , Tomografía de Coherencia Óptica/métodos
6.
Retina ; 42(3): e18, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34759234
7.
J Alzheimers Dis ; 100(1): 239-245, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38848189

RESUMEN

Background: Plasma and cerebrospinal fluid (CSF) levels of p-tau181 have been associated with Alzheimer's disease (AD). The retina and vitreous have shown measurable quantities of phosphorylated tau 181 (p-tau181). The aqueous humor, which can be collected during cataract surgery, may have measurable concentrations of p-tau181. Objective: To determine whether p-tau181 is detectable in the aqueous humor and if so, whether it is associated with other measures that might be consistent with AD such as higher plasma p-tau181 concentration and lower Montreal Cognitive Assessment (MoCA-BLIND version 7.1) score. Methods: Aqueous humor samples, blood samples, and MoCA-BLIND scores were collected from patients who did not carry a clinical diagnosis of cognitive impairment at the time of cataract surgery. Aqueous p-tau181 concentrations and plasma p-tau181 concentrations were then measured using ultra-sensitive single-molecule assay ELISA technology. A rank-transformed mixed-effects multivariate regression model was used to determine associations between aqueous concentrations, plasma concentrations, and MoCA-BLIND scores. Results: 16 eyes of 16 participants were enrolled with an average age of 71.6. Average MoCA-BLIND score was 20.6/22, average aqueous p-tau181 concentration was 6.4 pg/mL, and average plasma p-tau181 concentration was 3.1 pg/mL. Higher plasma p-tau181 was significantly associated with higher aqueous p-tau181 (p = 0.02). Aqueous p-tau181 and plasma p-tau181 were negatively associated with MoCA-BLIND scores (p = 0.005 and p = 0.001 respectively) in these patients. Conclusions: Aqueous p-tau181 is positively correlated with plasma p-tau181 and is negatively correlated with MoCA-BLIND scores. Further study in individuals with mild cognitive impairment or AD characterized by cerebrospinal fluid and volumetric MRI metrics may yield further insights.


Asunto(s)
Humor Acuoso , Cognición , Proteínas tau , Humanos , Proteínas tau/sangre , Proteínas tau/líquido cefalorraquídeo , Masculino , Femenino , Anciano , Fosforilación , Humor Acuoso/metabolismo , Persona de Mediana Edad , Cognición/fisiología , Pruebas de Estado Mental y Demencia , Anciano de 80 o más Años , Biomarcadores/sangre
8.
Transl Vis Sci Technol ; 13(1): 15, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38231496

RESUMEN

Purpose: To investigate retinal vascular characteristics using ultra-widefield (UWF) scanning laser ophthalmoscopy in Parkinson disease (PD). Methods: Individuals with an expert-confirmed clinical diagnosis of PD and controls with normal cognition without PD underwent Optos California UWF imaging. Patients with diabetes, uncontrolled hypertension, glaucoma, dementia, other movement disorders, or known retinal or optic nerve pathology were excluded. Images were analyzed using Vasculature Assessment and Measurement Platform for Images of the Retina (VAMPIRE-UWF) software, which describes retinal vessel width gradient and tortuosity, provides vascular network fractal dimensions, and conducts alpha-shape analysis to further characterize vascular morphology (complexity, Opαmin; spread, OpA). Results: In the PD cohort, 53 eyes of 38 subjects were assessed; in the control cohort, 51 eyes of 33 subjects were assessed. Eyes with PD had more tortuous retinal arteries in the superotemporal quadrant (P = 0.043). In eyes with PD, alpha-shape analysis revealed decreased OpA, indicating less retinal vasculature spread compared to controls (P = 0.032). Opαmin was decreased in PD (P = 0.044), suggesting increased vascular network complexity. No differences were observed in fractal dimension in any region of interest. Conclusions: This pilot study suggests that retinal vasculature assessment on UWF images using alpha-shape analysis reveals differences in retinal vascular network spread and complexity in PD and may be a more sensitive metric compared to fractal dimension. Translational Relevance: Retinal vasculature assessment using these novel methods may be useful in understanding ocular manifestations of PD and the development of retinal biomarkers.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/diagnóstico por imagen , Proyectos Piloto , Retina/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen , Cognición
9.
Ophthalmic Surg Lasers Imaging Retina ; 55(2): 78-84, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38346150

RESUMEN

OBJECTIVE: This study aimed to identify peripapillary microvascular changes in Alzheimer's disease (AD) and mild cognitive impairment (MCI). PATIENTS AND METHODS: In this prospective study, 66 eyes of 36 subjects with AD, 119 eyes of 63 with MCI, and 513 eyes of 265 controls with normal cognition were enrolled. Peripapillary capillary perfusion density (CPD), capillary flux index (CFI), and retinal nerve fiber layer (RNFL) thickness were determined. RESULTS: Average CPD differed significantly between all three groups (P = 0.001), being significantly greater in AD vs controls (0.446 ± 0.015 vs 0.439 ± 0.017, P = 0.001) and MCI vs controls (0.443 ± 0.020 vs 0.439 ± 0.017, P = 0.007) but not AD vs MCI (P = 0.69). CFI and average RNFL thickness did not significantly differ among groups (all P > 0.05). CONCLUSION: Peripapillary CPD is increased in eyes with AD or MCI compared to controls despite similar RNFL thickness. [Ophthalmic Surg Lasers Imaging Retina 2024;55:78-84.].


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Tomografía de Coherencia Óptica/métodos , Enfermedad de Alzheimer/diagnóstico , Estudios Prospectivos , Disfunción Cognitiva/diagnóstico , Cognición , Angiografía
10.
Ophthalmol Sci ; 4(4): 100480, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38827032

RESUMEN

Purpose: To utilize ultrawidefield (UWF) imaging to evaluate retinal and choroidal vasculature and structure in individuals with mild cognitive impairment (MCI) compared with that of controls with normal cognition. Design: Prospective cross sectional study. Participants: One hundred thirty-one eyes of 82 MCI patients and 230 eyes of 133 cognitively normal participants from the Eye Multimodal Imaging in Neurodegenerative Disease Study. Methods: A scanning laser ophthalmoscope (California, Optos Inc) was used to obtain UWF fundus color images. Images were analyzed with the Vasculature Assessment Platform for Images of the Retina UWF (VAMPIRE-UWF 2.0, Universities of Edinburgh and Dundee) software. Main outcome measures: Imaging parameters included vessel width gradient, vessel width intercept, large vessel choroidal vascular density, vessel tortuosity, and vessel fractal dimension. Results: Both retinal artery and vein width gradients were less negative in MCI patients compared with controls, demonstrating decreased rates of vessel thinning at the periphery (P < 0.001; P = 0.027). Retinal artery and vein width intercepts, a metric that extrapolates the width of the vessel at the center of the optic disc, were smaller in MCI patients compared with that of controls (P < 0.001; P = 0.017). The large vessel choroidal vascular density, which quantifies the vascular area versus the total choroidal area, was greater in MCI patients compared with controls (P = 0.025). Conclusions: When compared with controls with normal cognition, MCI patients had thinner retinal vasculature manifested in both the retinal arteries and the veins. In MCI, these thinner arteries and veins attenuated at a lower rate when traveling toward the periphery. MCI patients also had increased choroidal vascular density. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

11.
J Vitreoretin Dis ; 8(1): 67-74, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38223776

RESUMEN

Purpose: To evaluate the retinal and choroidal microvasculature and structure in individuals with dementia with Lewy bodies (DLB) compared with controls with normal cognition using optical coherence tomography (OCT) and OCT angiography (OCTA). Methods: An institutional review board-approved cross-sectional comparison of patients with DLB and cognitively normal controls was performed. The Cirrus HD-OCT 5000 with AngioPlex (Carl Zeiss Meditec) was used to obtain OCT and OCTA images. Results: Thirty-four eyes of 18 patients with DLB and 85 eyes of 48 cognitively normal patients were analyzed. The average capillary perfusion density (CPD) was higher in the DLB group than in the control group (P = .005). The average capillary flux index (CFI) and ganglion cell inner-plexiform layer (GC-IPL) thickness were lower in the DLB group than in the control group (P = .016 and P = .040, respectively). Conclusions: Patients with DLB had an increased peripapillary CPD, decreased peripapillary CFI, and attenuated GC-IPL thickness compared with those with normal cognition.

12.
PLoS One ; 19(1): e0296742, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38289919

RESUMEN

OBJECTIVE: To characterize retinal and choroidal microvascular and structural changes in patients who are gene positive for mutant huntingtin protein (mHtt) with symptoms of Huntington's Disease (HD). METHODS: This study is a cross-sectional comparison of patients who are gene positive for mHtt and exhibit symptoms of HD, either motor manifest or prodromal (HD group), and cognitively normal individuals without a family history of HD (control group). HD patients were diagnosed by Duke movement disorder neurologists based on the Unified Huntington's Disease Rating Scale (UHDRS). Fovea and optic nerve centered OCT and OCTA images were captured using Zeiss Cirrus HD-5000 with AngioPlex. Outcome metrics included central subfield thickness (CST), peripapillary retinal nerve fiber layer (pRNFL) thickness, ganglion cell-inner plexiform layer (GCIPL) thickness, and choroidal vascularity index (CVI) on OCT, and foveal avascular zone (FAZ) area, vessel density (VD), perfusion density (PD), capillary perfusion density (CPD), and capillary flux index (CFI) on OCTA. Generalized estimating equation (GEE) models were used to account for inter-eye correlation. RESULTS: Forty-four eyes of 23 patients in the HD group and 77 eyes of 39 patients in the control group were analyzed. Average GCIPL thickness and FAZ area were decreased in the HD group compared to controls (p = 0.001, p < 0.001). No other imaging metrics were significantly different between groups. CONCLUSIONS: Patients in the HD group had decreased GCIPL thickness and smaller FAZ area, highlighting the potential use of retinal biomarkers in detecting neurodegenerative changes in HD.


Asunto(s)
Enfermedad de Huntington , Humanos , Estudios Prospectivos , Estudios Transversales , Enfermedad de Huntington/diagnóstico por imagen , Células Ganglionares de la Retina , Microvasos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Vasos Retinianos/diagnóstico por imagen , Angiografía con Fluoresceína/métodos
13.
Transl Vis Sci Technol ; 12(6): 30, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37389540

RESUMEN

Purpose: To train and test convolutional neural networks (CNNs) to automate quality assessment of optical coherence tomography (OCT) and OCT angiography (OCTA) images in patients with neurodegenerative disease. Methods: Patients with neurodegenerative disease were enrolled in the Duke Eye Multimodal Imaging in Neurodegenerative Disease Study. Image inputs were ganglion cell-inner plexiform layer (GC-IPL) thickness maps and fovea-centered 6-mm × 6-mm OCTA scans of the superficial capillary plexus (SCP). Two trained graders manually labeled all images for quality (good versus poor). Interrater reliability (IRR) of manual quality assessment was calculated for a subset of each image type. Images were split into train, validation, and test sets in a 70%/15%/15% split. An AlexNet-based CNN was trained using these labels and evaluated with area under the receiver operating characteristic (AUC) and summaries of the confusion matrix. Results: A total of 1465 GC-IPL thickness maps (1217 good and 248 poor quality) and 2689 OCTA scans of the SCP (1797 good and 892 poor quality) served as model inputs. The IRR of quality assessment agreement by two graders was 97% and 90% for the GC-IPL maps and OCTA scans, respectively. The AlexNet-based CNNs trained to assess quality of the GC-IPL images and OCTA scans achieved AUCs of 0.990 and 0.832, respectively. Conclusions: CNNs can be trained to accurately differentiate good- from poor-quality GC-IPL thickness maps and OCTA scans of the macular SCP. Translational Relevance: Since good-quality retinal images are critical for the accurate assessment of microvasculature and structure, incorporating an automated image quality sorter may obviate the need for manual image review.


Asunto(s)
Enfermedades Neurodegenerativas , Tomografía de Coherencia Óptica , Humanos , Enfermedades Neurodegenerativas/diagnóstico por imagen , Reproducibilidad de los Resultados , Angiografía , Redes Neurales de la Computación
14.
Ophthalmol Sci ; 3(2): 100275, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36950088

RESUMEN

Purpose: To assess the intrasession repeatability of macular OCT angiography (OCTA) parameters in Alzheimer's disease (AD), mild cognitive impairment (MCI), Parkinson's disease (PD), and normal cognition (NC). Design: Cross sectional study. Subjects: Patients with a clinical diagnosis of AD, PD, MCI, or NC were imaged. Images with poor quality and of those with diabetes mellitus, glaucoma, or vitreoretinal disease were excluded from analysis. Methods Intervention or Testing: All participants were imaged using the Zeiss Cirrus HD-5000 with AngioPlex (Carl Zeiss Meditec, Software Version 11.0.0.29946) and repeat OCTA images were obtained for both eyes. Perfusion density (PFD), vessel density (VD), and Foveal avascular zone (FAZ) area were measured from 3 × 3 mm and 6 × 6 mm OCTA images centered on the fovea using an ETDRS grid overlay. Main Outcome Measures: Intraclass correlation coefficients were used to quantify repeatability of PFD, VD, and FAZ area measurements obtained from imaging. Results: 3 × 3 mm scans of 22 AD, 40 MCI, 21 PD, and 26 NC participants and 6 × 6 mm scans of 29 AD, 44 MCI, 29 PD, and 30 NC participants were analyzed. Repeatability values ranged from 0.64 (0.49-0.82) for 6 × 6 mm PFD in AD participants to 0.87 (0.67-0.92) for 3 × 3 mm PFD in AD participants. No significant differences were observed in repeatability between NC participants and those with neurodegenerative disease. Conclusions: Overall, similar OCTA repeatability was observed between NC participants and those with neurodegeneration. Regardless of diagnostic group, macular OCTA metrics demonstrated moderate to good repeatability. Financial Disclosures: The authors have no proprietary or commercial interest in any materials discussed in this article.

15.
Ophthalmol Sci ; 3(4): 100393, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38223333

RESUMEN

Purpose: To quantify rate of change of retinal microvascular and choroidal structural parameters in subjects with Parkinson's disease (PD) compared with controls using OCT and OCT angiography (OCTA). Design: Prospective longitudinal study. Participants: Seventy-four eyes of 40 participants with PD and 149 eyes of 78 control individuals from the Eye Multimodal Imaging in Neurodegenerative Disease database. Methods: Subjects underwent OCT and OCTA imaging at 2 time points approximately 12 months apart. Main Outcome Measures: Imaging parameters included central subfield thickness, ganglion cell-inner plexiform layer (GC-IPL) thickness, peripapillary retinal nerve fiber layer thickness, choroidal vascularity index, superficial capillary plexus perfusion density (PFD), vessel density (VD), and foveal avascular zone area. Results: Participants with PD had greater rate of yearly decrease in GC-IPL (PD = -0.403µm, control = + 0.128 µm; P = 0.01), greater yearly decline in PFD in the 3 × 3 mm ETDRS circle (PD = -0.016, control = + 0.002; P < 0.001) and ring (PD = -0.016, control = + 0.002; P < 0.001); 6 × 6 mm ETDRS circle (PD = -0.021, control = 0.00; P = 0.001), and outer ring (PD = -0.022, control = 0.00; P = 0.001). Participants with PD had greater rate of yearly decline in VD in 3 × 3 mm circle (PD = -0.939/mm, control = + 0.006/mm; P < 0.001) and ring (PD = -0.942/mm, control = + 0.013/mm; P < 0.001); 6 × 6 mm circle (PD = -0.72/mm, control = -0.054/mm; P = 0.006), and outer ring (PD = -0.746/mm, control = -0.054/mm; P = 0.005). When stratified by PD severity based on Hoehn and Yahr stage, faster rates of decline were seen in Hoehn and Yahr stages 3 to 4 in the 3 × 3 mm circle PFD and VD as well as 3 × 3 mm ring VD. Conclusions: Individuals with PD experience more rapid loss of retinal microvasculature quantified on OCTA and more rapid thinning of the GC-IPL than controls. There may be more rapid loss in patients with greater disease severity. Financial Disclosures: The author(s) have no proprietary or commercial interest in any materials discussed in this article.

16.
Transl Vis Sci Technol ; 12(1): 13, 2023 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-36622689

RESUMEN

Purpose: Retinal microvascular abnormalities measured on retinal images are a potential source of prognostic biomarkers of vascular changes in the neurodegenerating brain. We assessed the presence of these abnormalities in Alzheimer's dementia and mild cognitive impairment (MCI) using ultra-widefield (UWF) retinal imaging. Methods: UWF images from 103 participants (28 with Alzheimer's dementia, 30 with MCI, and 45 with normal cognition) underwent analysis to quantify measures of retinal vascular branching complexity, width, and tortuosity. Results: Participants with Alzheimer's dementia displayed increased vessel branching in the midperipheral retina and increased arteriolar thinning. Participants with MCI displayed increased rates of arteriolar and venular thinning and a trend for decreased vessel branching. Conclusions: Statistically significant differences in the retinal vasculature in peripheral regions of the retina were observed among the distinct cognitive stages. However, larger studies are required to establish the clinical importance of our findings. UWF imaging may be a promising modality to assess a larger view of the retinal vasculature to uncover retinal changes in Alzheimer's disease. Translational Relevance: This pilot work reports an investigation into which retinal vasculature measurements may be useful surrogate measures of cognitive decline, as well as technical developments (e.g., measurement standardization), that are first required to establish their recommended use and translational potential.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Enfermedad de Alzheimer/diagnóstico por imagen , Proyectos Piloto , Disfunción Cognitiva/diagnóstico por imagen , Retina/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen
17.
J Vitreoretin Dis ; 6(3): 188-193, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37008544

RESUMEN

Purpose: This work describes the clinical management and outcomes in cases of presumed infectious endophthalmitis following intravitreal injection at a tertiary academic medical center. Methods: A retrospective review took place of eyes that presented to the Duke Eye Center over a 9-year period and were diagnosed with intravitreal injection-related endophthalmitis. Clinical presentation, management, microbiologic yield, visual outcomes, and complications were abstracted from medical records. Results: Of 23 eyes diagnosed with postinjection endophthalmitis, 52.2% underwent anterior chamber tap (33.3% of which first underwent dry needle vitreous tap), 47.8% underwent needle vitreous tap, 17.4% underwent neither, and none underwent pars plana vitrectomy (PPV) for initial management. Subsequent PPV was performed in 6 eyes (26.1%). Mean visual acuity (VA) improved by 50 Early Treatment Diabetic Retinopathy Study letters at 6 months. Eyes that underwent initial anterior chamber tap had worse presenting VA than those that did not (P = .01). Eyes undergoing subsequent PPV had worse VA at presentation (P = .02) and at 6 months (P < .001). Eyes presenting with VA of hand motion (20/8000) or worse were more likely to undergo subsequent PPV (P = .02). Conclusions: Eyes with intravitreal injection-related endophthalmitis presenting with VA of hand motion or worse were more likely to undergo subsequent PPV. Future studies with larger cohorts may reveal whether earlier vitrectomy should be considered in these patients.

18.
J Vitreoretin Dis ; 6(2): 151-154, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37008669

RESUMEN

Purpose: To report a case of Mycobacterium chelonae endogenous endophthalmitis in a 28-year-old man with recent intravenous drug use that presented as an intraretinal peripapillary granuloma extending from the optic nerve head with an associated macular tractional retinal detachment. Methods: Case report. Results: Anterior chamber tap yielded aqueous cultures positive for M chelonae. A diagnostic and therapeutic vitrectomy was performed after inpatient hospitalization for 3 weeks to relieve a progressively worsening tractional retinal detachment. Conclusions: Atypical causes of endophthalmitis, including nontuberculous mycobacterium, in the population of individuals addicted to intravenous drugs may present with intraretinal peripapillary granuloma associated with a macular tractional retinal detachment. Surgical debulking to relieve anteroposterior traction is an effective treatment option to improve long-term visual outcomes.

19.
Ophthalmol Retina ; 6(1): 29-36, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33713852

RESUMEN

PURPOSE: To compare radial peripapillary capillary (RPC) plexus vascular parameters and retinal nerve fiber layer (RNFL) thickness between those with Parkinson's disease (PD) and controls. DESIGN: Prospective, cross-sectional study. PARTICIPANTS: A total of 151 eyes of 81 PD participants and 514 eyes of 266 controls. METHODS: Participants underwent OCT angiography (OCTA) imaging using the Zeiss Cirrus HD-5000 AngioPlex (Carl Zeiss AG). Capillary perfusion density (CPD) and capillary flux index (CFI) were assessed using a 4.5 × 4.5-mm peripapillary scan, and RNFL thickness was assessed using a 200 × 200-µm optic nerve cube OCT scan. Hoehn and Yahr clinical staging for PD was determined by an experienced movement disorders specialist. Generalized estimating equations adjusted for age and sex were used for analysis. MAIN OUTCOME MEASURES: Differences in RNFL thickness, CPD, and CFI as assessed using multivariable generalized estimating equations between individuals with PD and controls. RESULTS: After adjustment for age and sex, average CPD (0.446% ± 0.018% vs. 0.439% ± 0.017%, P < 0.001) and CFI (0.434 ± 0.031 vs. 0.426 ± 0.036, P = 0.008) were significantly higher in PD eyes. Average RNFL thickness was similar between groups (PD 89.71 ± 10.45 µm vs. control 88.20 ± 10.33 µm, P = 0.19). Significant correlations between Hoehn and Yahr stage and OCTA parameters were not observed. The OCTA parameters were not significantly different between eyes of the same patient. CONCLUSIONS: Increased peripapillary microvascular density and flux were detected in a large cohort of individuals with PD compared with controls after adjusting for age and sex; however, RNFL thickness was similar between groups. Peripapillary OCTA parameters may not correlate with the severity of PD. OCTA may serve as a noninvasive method to identify novel biomarkers for the early diagnosis of PD; as such, this methodology deserves further investigation.


Asunto(s)
Angiografía con Fluoresceína/métodos , Microvasos/diagnóstico por imagen , Enfermedad de Parkinson/complicaciones , Enfermedades de la Retina/diagnóstico , Células Ganglionares de la Retina/patología , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Estudios Transversales , Femenino , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Disco Óptico/diagnóstico por imagen , Enfermedad de Parkinson/diagnóstico , Estudios Prospectivos , Enfermedades de la Retina/etiología
20.
Ophthalmol Retina ; 6(7): 607-619, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35283324

RESUMEN

PURPOSE: To assess the baseline differences and longitudinal rate of change in retinal and choroidal imaging parameters between apolipoprotein ε4 (APOE ε4) carriers and noncarriers with normal cognition. DESIGN: Prospective study. SUBJECTS: Four hundred thirteen eyes of 218 individuals with normal cognition aged ≥ 55 years with known APOE status (98 APOE ε4 carriers and 120 noncarriers). The exclusion criteria included diabetes mellitus, uncontrolled hypertension, glaucoma, and vitreoretinal or neurodegenerative disease. METHODS: OCT and OCT angiography (OCTA) were performed at baseline and 2 years (Zeiss Cirrus HD-OCT 5000 with AngioPlex; Zeiss Meditec). The groups were compared using sex- and age-adjusted generalized estimating equations. MAIN OUTCOME MEASURES: OCT parameters: retinal nerve fiber layer thickness, macular ganglion cell-inner plexiform layer thickness, central subfield thickness (CST), and choroidal vascularity index. OCT angiography parameters: foveal avascular zone area, perfusion density (PD), vessel density, peripapillary capillary PD (CPD), and capillary flux index (CFI). The rate of change per year was calculated. RESULTS: At the baseline, the APOE ε4 carriers had lower CST (P = 0.018), PD in the 6-mm ETDRS circle (P = 0.049), and temporal CFI (P = 0.047). Seventy-one APOE ε4 carriers and 78 noncarriers returned at 2 years; at follow-up, the 6-mm ETDRS circle (P = 0.05) and outer ring (P = 0.049) showed lower PD in the APOE ε4 carriers, with no differences in the rates of change between the groups (all P > 0.05). CONCLUSIONS: There was exploratory evidence of differences in the CST, PD, and peripapillary CFI between the APOE ε4 carriers and noncarriers with normal cognition. Larger and longer-term studies may help further elucidate the potential prognostic value of these findings.


Asunto(s)
Enfermedad de Alzheimer , Enfermedades Neurodegenerativas , Enfermedad de Alzheimer/diagnóstico , Enfermedad de Alzheimer/genética , Apolipoproteína E4/genética , Coroides , Humanos , Estudios Prospectivos , Retina/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA