Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Mol Cell Proteomics ; 18(4): 622-641, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30617155

RESUMEN

Lung cancer is the leading cause of cancer death in both men and women. Tumor heterogeneity is an impediment to targeted treatment of all cancers, including lung cancer. Here, we sought to characterize tumor proteome and phosphoproteome changes by longitudinal, prospective collection of tumor tissue from an exceptional responder lung adenocarcinoma patient who survived with metastatic lung adenocarcinoma for over seven years while undergoing HER2-directed therapy in combination with chemotherapy. We employed "Super-SILAC" and TMT labeling strategies to quantify the proteome and phosphoproteome of a lung metastatic site and eight distinct metastatic progressive lymph nodes collected during these seven years, including five lymph nodes procured at autopsy. We identified specific signaling networks enriched in lung compared with the lymph node metastatic sites. We correlated the changes in protein abundance with changes in copy number alteration (CNA) and transcript expression. ERBB2/HER2 protein expression was higher in lung, consistent with a higher degree of ERBB2 amplification in lung compared with the lymph node metastatic sites. To further interrogate the mass spectrometry data, a patient-specific database was built by incorporating all the somatic and germline variants identified by whole genome sequencing (WGS) of genomic DNA from the lung, one lymph node metastatic site and blood. An extensive validation pipeline was built to confirm variant peptides. We validated 360 spectra corresponding to 55 germline and 6 somatic variant peptides. Targeted MRM assays revealed two novel variant somatic peptides, CDK12-G879V and FASN-R1439Q, expressed in lung and lymph node metastatic sites, respectively. The CDK12-G879V mutation likely results in a nonfunctional CDK12 kinase and chemotherapy susceptibility in lung metastatic sites. Knockdown of CDK12 in lung adenocarcinoma cells increased chemotherapy sensitivity which was rescued by wild type, but not CDK12-G879V expression, consistent with the complete resolution of the lung metastatic sites in this patient.


Asunto(s)
Adenocarcinoma del Pulmón/genética , Adenocarcinoma del Pulmón/patología , Quinasas Ciclina-Dependientes/genética , Espectrometría de Masas/métodos , Mutación/genética , Proteómica , Adenocarcinoma del Pulmón/metabolismo , Línea Celular Tumoral , Variaciones en el Número de Copia de ADN/genética , Regulación Neoplásica de la Expresión Génica , Humanos , Metástasis Linfática , Masculino , Persona de Mediana Edad , Proteínas Mutantes/metabolismo , Metástasis de la Neoplasia , Proteínas de Neoplasias/metabolismo , Péptidos/metabolismo , Fosfoproteínas/metabolismo , Fosforilación , Reproducibilidad de los Resultados
2.
Mol Cell Proteomics ; 14(9): 2357-74, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25693799

RESUMEN

There is an increasing need in biology and clinical medicine to robustly and reliably measure tens to hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility, and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here, we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and seven control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data, we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to subnanogram/ml sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and interlaboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy-isotope-labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an interlaboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality control measures, enables sensitive, specific, reproducible, and quantitative measurements of proteins and peptides in complex biological matrices such as plasma.


Asunto(s)
Proteínas de Neoplasias/sangre , Neoplasias/metabolismo , Péptidos/análisis , Proteómica/métodos , Cromatografía Liquida/métodos , Humanos , Marcaje Isotópico , Espectrometría de Masas/métodos , Proteínas de Neoplasias/química , Proteínas de Neoplasias/aislamiento & purificación , Neoplasias/sangre , Péptidos/química , Reproducibilidad de los Resultados
3.
J Proteome Res ; 15(3): 1023-32, 2016 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-26860878

RESUMEN

The Clinical Proteomic Tumor Analysis Consortium (CPTAC) has produced large proteomics data sets from the mass spectrometric interrogation of tumor samples previously analyzed by The Cancer Genome Atlas (TCGA) program. The availability of the genomic and proteomic data is enabling proteogenomic study for both reference (i.e., contained in major sequence databases) and nonreference markers of cancer. The CPTAC laboratories have focused on colon, breast, and ovarian tissues in the first round of analyses; spectra from these data sets were produced from 2D liquid chromatography-tandem mass spectrometry analyses and represent deep coverage. To reduce the variability introduced by disparate data analysis platforms (e.g., software packages, versions, parameters, sequence databases, etc.), the CPTAC Common Data Analysis Platform (CDAP) was created. The CDAP produces both peptide-spectrum-match (PSM) reports and gene-level reports. The pipeline processes raw mass spectrometry data according to the following: (1) peak-picking and quantitative data extraction, (2) database searching, (3) gene-based protein parsimony, and (4) false-discovery rate-based filtering. The pipeline also produces localization scores for the phosphopeptide enrichment studies using the PhosphoRS program. Quantitative information for each of the data sets is specific to the sample processing, with PSM and protein reports containing the spectrum-level or gene-level ("rolled-up") precursor peak areas and spectral counts for label-free or reporter ion log-ratios for 4plex iTRAQ. The reports are available in simple tab-delimited formats and, for the PSM-reports, in mzIdentML. The goal of the CDAP is to provide standard, uniform reports for all of the CPTAC data to enable comparisons between different samples and cancer types as well as across the major omics fields.


Asunto(s)
Neoplasias/diagnóstico , Neoplasias/metabolismo , Proteómica , Biomarcadores de Tumor/metabolismo , Humanos , Proteoma/metabolismo
4.
Mol Cell Proteomics ; 13(5): 1341-51, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24563535

RESUMEN

Normalization is an important step in the analysis of quantitative proteomics data. If this step is ignored, systematic biases can lead to incorrect assumptions about regulation. Most statistical procedures for normalizing proteomics data have been borrowed from genomics where their development has focused on the removal of so-called 'batch effects.' In general, a typical normalization step in proteomics works under the assumption that most peptides/proteins do not change; scaling is then used to give a median log-ratio of 0. The focus of this work was to identify other factors, derived from knowledge of the variables in proteomics, which might be used to improve normalization. Here we have examined the multi-laboratory data sets from Phase I of the NCI's CPTAC program. Surprisingly, the most important bias variables affecting peptide intensities within labs were retention time and charge state. The magnitude of these observations was exaggerated in samples of unequal concentrations or "spike-in" levels, presumably because the average precursor charge for peptides with higher charge state potentials is lower at higher relative sample concentrations. These effects are consistent with reduced protonation during electrospray and demonstrate that the physical properties of the peptides themselves can serve as good reporters of systematic biases. Between labs, retention time, precursor m/z, and peptide length were most commonly the top-ranked bias variables, over the standardly used average intensity (A). A larger set of variables was then used to develop a stepwise normalization procedure. This statistical model was found to perform as well or better on the CPTAC mock biomarker data than other commonly used methods. Furthermore, the method described here does not require a priori knowledge of the systematic biases in a given data set. These improvements can be attributed to the inclusion of variables other than average intensity during normalization.


Asunto(s)
Biometría/métodos , Péptidos/análisis , Proteínas/análisis , Proteómica/métodos , Cromatografía Liquida , Interpretación Estadística de Datos , Espectrometría de Masas , Modelos Estadísticos , Proteínas/química
5.
Mol Cell Proteomics ; 13(9): 2435-49, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24889059

RESUMEN

This work presents a method for creating a mass spectral library containing tandem spectra of identifiable peptide ions in the tryptic digestion of a single protein. Human serum albumin (HSA(1)) was selected for this purpose owing to its ubiquity, high level of characterization and availability of digest data. The underlying experimental data consisted of ∼3000 one-dimensional LC-ESI-MS/MS runs with ion-trap fragmentation. In order to generate a wide range of peptides, studies covered a broad set of instrument and digestion conditions using multiple sources of HSA and trypsin. Computer methods were developed to enable the reliable identification and reference spectrum extraction of all peptide ions identifiable by current sequence search methods. This process made use of both MS2 (tandem) spectra and MS1 (electrospray) data. Identified spectra were generated for 2918 different peptide ions, using a variety of manually-validated filters to ensure spectrum quality and identification reliability. The resulting library was composed of 10% conventional tryptic and 29% semitryptic peptide ions, along with 42% tryptic peptide ions with known or unknown modifications, which included both analytical artifacts and post-translational modifications (PTMs) present in the original HSA. The remaining 19% contained unexpected missed-cleavages or were under/over alkylated. The methods described can be extended to create equivalent spectral libraries for any target protein. Such libraries have a number of applications in addition to their known advantages of speed and sensitivity, including the ready re-identification of known PTMs, rejection of artifact spectra and a means of assessing sample and digestion quality.


Asunto(s)
Biblioteca de Péptidos , Albúmina Sérica/química , Cromatografía Liquida , Humanos , Proteolisis , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Tripsina/química
6.
Proteomics ; 15(7): 1194-5, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25762020

RESUMEN

Multiple-reaction monitoring (MRM) of peptides has been recognized as a promising technology because it is sensitive and robust. Borrowed from stable-isotope dilution (SID) methodologies in the field of small molecules, MRM is now routinely used in proteomics laboratories. While its usefulness validating candidate targets is widely accepted, it has not been established as a discovery tool. Traditional thinking has been that MRM workflows cannot be multiplexed high enough to efficiently profile. This is due to slower instrument scan rates and the complexities of developing increasingly large scheduling methods. In this issue, Colangelo et al. (Proteomics 2015, 15, 1202-1214) describe a pipeline (xMRM) for discovery-style MRM using label-free methods (i.e. relative quantitation). Label-free comes with cost benefits as does MRM, where data are easier to analyze than full-scan. Their paper offers numerous improvements in method design and data analysis. The robustness of their pipeline was tested on rodent postsynaptic density fractions. There, they were able to accurately quantify 112 proteins at a CV% of 11.4, with only 2.5% of the 1697 transitions requiring user intervention. Colangelo et al. aim to extend the reach of MRM deeper into the realm of discovery proteomics, an area that is currently dominated by data-dependent and data-independent workflows.


Asunto(s)
Proteínas del Tejido Nervioso/química , Proteoma/química , Sinapsis/química , Animales
7.
Mol Cell Proteomics ; 12(9): 2623-39, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23689285

RESUMEN

Multiple reaction monitoring (MRM) mass spectrometry coupled with stable isotope dilution (SID) and liquid chromatography (LC) is increasingly used in biological and clinical studies for precise and reproducible quantification of peptides and proteins in complex sample matrices. Robust LC-SID-MRM-MS-based assays that can be replicated across laboratories and ultimately in clinical laboratory settings require standardized protocols to demonstrate that the analysis platforms are performing adequately. We developed a system suitability protocol (SSP), which employs a predigested mixture of six proteins, to facilitate performance evaluation of LC-SID-MRM-MS instrument platforms, configured with nanoflow-LC systems interfaced to triple quadrupole mass spectrometers. The SSP was designed for use with low multiplex analyses as well as high multiplex approaches when software-driven scheduling of data acquisition is required. Performance was assessed by monitoring of a range of chromatographic and mass spectrometric metrics including peak width, chromatographic resolution, peak capacity, and the variability in peak area and analyte retention time (RT) stability. The SSP, which was evaluated in 11 laboratories on a total of 15 different instruments, enabled early diagnoses of LC and MS anomalies that indicated suboptimal LC-MRM-MS performance. The observed range in variation of each of the metrics scrutinized serves to define the criteria for optimized LC-SID-MRM-MS platforms for routine use, with pass/fail criteria for system suitability performance measures defined as peak area coefficient of variation <0.15, peak width coefficient of variation <0.15, standard deviation of RT <0.15 min (9 s), and the RT drift <0.5min (30 s). The deleterious effect of a marginally performing LC-SID-MRM-MS system on the limit of quantification (LOQ) in targeted quantitative assays illustrates the use and need for a SSP to establish robust and reliable system performance. Use of a SSP helps to ensure that analyte quantification measurements can be replicated with good precision within and across multiple laboratories and should facilitate more widespread use of MRM-MS technology by the basic biomedical and clinical laboratory research communities.


Asunto(s)
Cromatografía Liquida/instrumentación , Cromatografía Liquida/métodos , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Secuencia de Aminoácidos , Animales , Bovinos , Límite de Detección , Datos de Secuencia Molecular , Péptidos/química , Péptidos/metabolismo , Estándares de Referencia , Programas Informáticos , Factores de Tiempo
8.
Proteomics ; 13(22): 3247-50, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24123856

RESUMEN

Spectral library searching has many advantages over sequence database searching, yet it has not been widely adopted. One possible reason for this is that users are unsure exactly how to interpret the similarity scores (e.g., "dot products" are not probability-based scores). Methods to create decoys have been proposed, but, as developers caution, may produce proxies that are not equivalent to reversed sequences. In this issue, Shao et al. (Proteomics 2013, 13, 3273-3283) report advances in spectral library searching where the focus is not on improving the performance of their search engine, SpectraST, but is instead on improving the statistical meaningfulness of its discriminant score and removing the need for decoys. The results in their paper indicate that by "standardizing" the input and library spectra, sensitivity is not lost but is, surprisingly, gained. Their tests also show that false discovery rate (FDR) estimates, derived from their new score, track better with "ground truth" than decoy searching. It is possible that their work strikes a good balance between the theory of library searching and its application. And as such, they hope to have removed a major entrance barrier for some researchers previously unwilling to try library searching.


Asunto(s)
Biología Computacional/métodos , Bases de Datos de Proteínas , Modelos Estadísticos , Péptidos , Espectrometría de Masas en Tándem/métodos , Humanos
9.
Proteomics ; 13(6): 904-9, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23319436

RESUMEN

Proteomics is a rapidly transforming interdisciplinary field of research that embraces a diverse set of analytical approaches to tackle problems in fundamental and applied biology. This viewpoint article highlights the benefits of interlaboratory studies and standardization initiatives to enable investigators to address many of the challenges found in proteomics research. Among these initiatives, we discuss our efforts on a comprehensive performance standard for characterizing PTMs by MS that was recently developed by the Association of Biomolecular Resource Facilities (ABRF) Proteomics Standards Research Group (sPRG).


Asunto(s)
Laboratorios/normas , Espectrometría de Masas/normas , Procesamiento Proteico-Postraduccional , Proteómica , Conducta Cooperativa , Guías como Asunto , Humanos , Proteoma/metabolismo , Estándares de Referencia
10.
J Proteome Res ; 12(12): 5666-80, 2013 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-24116745

RESUMEN

Trypsin is an endoprotease commonly used for sample preparation in proteomics experiments. Importantly, protein digestion is dependent on multiple factors, including the trypsin origin and digestion conditions. In-depth characterization of trypsin activity could lead to improved reliability of peptide detection and quantitation in both targeted and discovery proteomics studies. To this end, we assembled a data analysis pipeline and suite of visualization tools for quality control and comprehensive characterization of preanalytical variability in proteomics experiments. Using these tools, we evaluated six available proteomics-grade trypsins and their digestion of a single purified protein, human serum albumin (HSA). HSA was aliquoted and then digested for 2 or 18 h for each trypsin, and the resulting digests were desalted and analyzed in triplicate by reversed-phase liquid chromatography-tandem mass spectrometry. Peptides were identified and quantified using the NIST MSQC pipeline and a comprehensive HSA mass spectral library. We performed a statistical analysis of peptide abundances from different digests and further visualized the data using the principal component analysis and quantitative protein "sequence maps". While the performance of individual trypsins across repeat digests was reproducible, significant differences were observed depending on the origin of the trypsin (i.e., bovine vs porcine). Bovine trypsins produced a higher number of peptides containing missed cleavages, whereas porcine trypsins produced more semitryptic peptides. In addition, many cleavage sites showed variable digestion kinetics patterns, evident from the comparison of peptide abundances in 2 h vs 18 h digests. Overall, this work illustrates effects of an often neglected source of variability in proteomics experiments: the origin of the trypsin.


Asunto(s)
Fragmentos de Péptidos/aislamiento & purificación , Proteómica/normas , Albúmina Sérica/química , Tripsina/química , Secuencia de Aminoácidos , Animales , Bovinos , Cromatografía de Fase Inversa , Humanos , Datos de Secuencia Molecular , Fragmentos de Péptidos/química , Análisis de Componente Principal , Proteolisis , Control de Calidad , Reproducibilidad de los Resultados , Especificidad de la Especie , Porcinos , Espectrometría de Masas en Tándem
11.
Anal Chem ; 85(24): 11725-31, 2013 Dec 17.
Artículo en Inglés | MEDLINE | ID: mdl-24147600

RESUMEN

Recent progress in metabolomics and the development of increasingly sensitive analytical techniques have renewed interest in global profiling, i.e., semiquantitative monitoring of all chemical constituents of biological fluids. In this work, we have performed global profiling of NIST SRM 1950, "Metabolites in Human Plasma", using GC-MS, LC-MS, and NMR. Metabolome coverage, difficulties, and reproducibility of the experiments on each platform are discussed. A total of 353 metabolites have been identified in this material. GC-MS provides 65 unique identifications, and most of the identifications from NMR overlap with the LC-MS identifications, except for some small sugars that are not directly found by LC-MS. Also, repeatability and intermediate precision analyses show that the SRM 1950 profiling is reproducible enough to consider this material as a good choice to distinguish between analytical and biological variability. Clinical laboratory data shows that most results are within the reference ranges for each assay. In-house computational tools have been developed or modified for MS data processing and interactive web display. All data and programs are freely available online at http://peptide.nist.gov/ and http://srmd.nist.gov/ .


Asunto(s)
Análisis Químico de la Sangre/normas , Cromatografía Liquida/normas , Cromatografía de Gases y Espectrometría de Masas/normas , Internet , Espectroscopía de Resonancia Magnética/normas , Metabolómica/normas , United States Government Agencies , Métodos Analíticos de la Preparación de la Muestra , Humanos , Estándares de Referencia , Programas Informáticos , Estados Unidos
12.
Anal Bioanal Chem ; 405(13): 4451-65, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22941178

RESUMEN

Standard Reference Materials (SRMs) offer the scientific community a stable and homogenous source of material that holds countless application possibilities. Traditionally, the National Institute of Standards and Technology (NIST) has provided SRMs with associated quantitative information (certified values) for a select group of targeted analytes as measured in a solution or complex matrix. While the current needs of the SRM community are expanding to include non-quantitative data, NIST is attempting to broaden the scope of how and what information is offered to the SRM community by providing qualitative information about biomaterials, such as chromatographic fingerprints and profiles of untargeted identifications. In this work, metabolomic and proteomic profiling efforts were employed to characterize a suite of six Vaccinium berry SRMs. In the discovery phase, liquid chromatography-tandem mass spectrometry (LC-MS/MS) data was matched to mass spectral libraries; a subsequent validation phase based on multiple-reaction monitoring LC-MS/MS relied on both retention time matching of authentic standards along with fragmentation data for a qualitative overview of the most prominent organic compounds present. Definitive and putative identifications were determined for over 70 metabolites based on reporting guidelines set forth by the Metabolomics Standards Initiative (Metabolomics 3(3):211-221, 2007), and the capability of electrospray ionization mass spectrometry (ESI-MS) to profile untargeted metabolites within a complex matrix using mass spectral matching is demonstrated. Bottom-up proteomic analyses were possible using peptide databases translated from expressed sequence tags (ESTs). Homology searches provided identification of novel Vaccinium proteins based on homology to related genera. Chromatographic fingerprints of these berry materials were acquired for supplemental qualitative information to be provided to users of these SRMs. An unbounded set of qualitative data about a biomaterial is a valuable complement to quantitative information traditionally provided in NIST Certificates of Analysis.


Asunto(s)
Cromatografía Liquida/normas , Frutas/química , Espectrometría de Masas/normas , Metaboloma , Vaccinium/química , Cromatografía Liquida/métodos , Bases de Datos de Proteínas , Etiquetas de Secuencia Expresada , Frutas/clasificación , Frutas/genética , Espectrometría de Masas/métodos , Proteómica , Estándares de Referencia , Valores de Referencia , Vaccinium/clasificación , Vaccinium/genética
13.
Cancer Cell ; 41(8): 1397-1406, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37582339

RESUMEN

The National Cancer Institute's Clinical Proteomic Tumor Analysis Consortium (CPTAC) investigates tumors from a proteogenomic perspective, creating rich multi-omics datasets connecting genomic aberrations to cancer phenotypes. To facilitate pan-cancer investigations, we have generated harmonized genomic, transcriptomic, proteomic, and clinical data for >1000 tumors in 10 cohorts to create a cohesive and powerful dataset for scientific discovery. We outline efforts by the CPTAC pan-cancer working group in data harmonization, data dissemination, and computational resources for aiding biological discoveries. We also discuss challenges for multi-omics data integration and analysis, specifically the unique challenges of working with both nucleotide sequencing and mass spectrometry proteomics data.


Asunto(s)
Neoplasias , Proteogenómica , Humanos , Proteómica , Genómica , Neoplasias/genética , Perfilación de la Expresión Génica
14.
Proteomics ; 12(7): 923-31, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22522798

RESUMEN

The emergence of MS-based proteomic platforms as a prominent technology utilized in biochemical and biomedical research has increased the need for high-quality MS measurements. To address this need, National Institute of Standards and Technology (NIST) reference material (RM) 8323 yeast protein extract is introduced as a proteomics quality control material for benchmarking the preanalytical and analytical performance of proteomics-based experimental workflows. RM 8323 yeast protein extract is based upon the well-characterized eukaryote Saccharomyces cerevisiae and can be utilized in the design and optimization of proteomics-based methodologies from sample preparation to data analysis. To demonstrate its utility as a proteomics quality control material, we coupled LC-MS/MS measurements of RM 8323 with the NIST MS Quality Control (MSQC) performance metrics to quantitatively assess the LC-MS/MS instrumentation parameters that influence measurement accuracy, repeatability, and reproducibility. Due to the complexity of the yeast proteome, we also demonstrate how NIST RM 8323, along with the NIST MSQC performance metrics, can be used in the evaluation and optimization of proteomics-based sample preparation methods.


Asunto(s)
Proteómica/métodos , Proteómica/normas , Cromatografía Liquida/normas , Proteínas Fúngicas/análisis , Proteoma/análisis , Estándares de Referencia , Reproducibilidad de los Resultados , Saccharomyces cerevisiae , Espectrometría de Masas en Tándem/normas
15.
Mol Cell Proteomics ; 9(2): 242-54, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19858499

RESUMEN

Optimal performance of LC-MS/MS platforms is critical to generating high quality proteomics data. Although individual laboratories have developed quality control samples, there is no widely available performance standard of biological complexity (and associated reference data sets) for benchmarking of platform performance for analysis of complex biological proteomes across different laboratories in the community. Individual preparations of the yeast Saccharomyces cerevisiae proteome have been used extensively by laboratories in the proteomics community to characterize LC-MS platform performance. The yeast proteome is uniquely attractive as a performance standard because it is the most extensively characterized complex biological proteome and the only one associated with several large scale studies estimating the abundance of all detectable proteins. In this study, we describe a standard operating protocol for large scale production of the yeast performance standard and offer aliquots to the community through the National Institute of Standards and Technology where the yeast proteome is under development as a certified reference material to meet the long term needs of the community. Using a series of metrics that characterize LC-MS performance, we provide a reference data set demonstrating typical performance of commonly used ion trap instrument platforms in expert laboratories; the results provide a basis for laboratories to benchmark their own performance, to improve upon current methods, and to evaluate new technologies. Additionally, we demonstrate how the yeast reference, spiked with human proteins, can be used to benchmark the power of proteomics platforms for detection of differentially expressed proteins at different levels of concentration in a complex matrix, thereby providing a metric to evaluate and minimize pre-analytical and analytical variation in comparative proteomics experiments.


Asunto(s)
Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Técnicas de Laboratorio Clínico/normas , Espectrometría de Masas/métodos , Espectrometría de Masas/normas , Proteínas de Saccharomyces cerevisiae/análisis , Saccharomyces cerevisiae/metabolismo , Biomarcadores/metabolismo , Humanos , Proteómica/normas
16.
Mol Cell Proteomics ; 9(2): 225-41, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19837981

RESUMEN

A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications.


Asunto(s)
Cromatografía Liquida/métodos , Cromatografía Liquida/normas , Proteómica/métodos , Proteómica/normas , Espectrometría de Masas en Tándem/métodos , Espectrometría de Masas en Tándem/normas , Animales , Pollos , Proteínas del Huevo/análisis , Laboratorios , Proteoma/análisis , Reproducibilidad de los Resultados , Saccharomyces cerevisiae/metabolismo , Proteínas de Saccharomyces cerevisiae/análisis , Programas Informáticos
17.
J Proteome Res ; 9(10): 4982-91, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20677825

RESUMEN

Immunoaffinity depletion with antibodies to the top 7 or top 14 high-abundance plasma proteins is used to enhance detection of lower abundance proteins in both shotgun and targeted proteomic analyses. We evaluated the effects of top 7/top 14 immunodepletion on the shotgun proteomic analysis of human plasma. Our goal was to evaluate the impact of immunodepletion on detection of proteins across detectable ranges of abundance. The depletion columns afforded highly repeatable and efficient plasma protein fractionation. Relatively few nontargeted proteins were captured by the depletion columns. Analyses of unfractionated and immunodepleted plasma by peptide isoelectric focusing (IEF), followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS), demonstrated enrichment of nontargeted plasma proteins by an average of 4-fold, as assessed by MS/MS spectral counting. Either top 7 or top 14 immunodepletion resulted in a 25% increase in identified proteins compared to unfractionated plasma. Although 23 low-abundance (<10 ng mL(-1)) plasma proteins were detected, they accounted for only 5-6% of total protein identifications in immunodepleted plasma. In both unfractionated and immunodepleted plasma, the 50 most abundant plasma proteins accounted for 90% of cumulative spectral counts and precursor ion intensities, leaving little capacity to sample lower abundance proteins. Untargeted proteomic analyses using current LC-MS/MS platforms-even with immunodepletion-cannot be expected to efficiently discover low-abundance, disease-specific biomarkers in plasma.


Asunto(s)
Biomarcadores/análisis , Proteínas Sanguíneas/análisis , Proteoma/análisis , Proteómica/métodos , Anticuerpos/inmunología , Biomarcadores/sangre , Proteínas Sanguíneas/inmunología , Cromatografía Liquida , Humanos , Focalización Isoeléctrica , Proteoma/inmunología , Reproducibilidad de los Resultados , Espectrometría de Masas en Tándem
18.
J Proteome Res ; 9(2): 761-76, 2010 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-19921851

RESUMEN

The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35-60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind repeatability of technical replicates on a single instrument by several percent. These findings reinforce the importance of evaluating repeatability as a fundamental characteristic of analytical technologies.


Asunto(s)
Cromatografía Liquida/métodos , Proteoma , Espectrometría de Masas en Tándem/métodos , Reproducibilidad de los Resultados
19.
Anal Chem ; 82(5): 1584-8, 2010 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-20121140

RESUMEN

A method that relies on subtractive tissue-directed shot-gun proteomics to identify tumor proteins in the blood of a patient newly diagnosed with cancer is described. To avoid analytical and statistical biases caused by physiologic variability of protein expression in the human population, this method was applied on clinical specimens obtained from a single patient diagnosed with nonmetastatic renal cell carcinoma (RCC). The proteomes extracted from tumor, normal adjacent tissue and preoperative plasma were analyzed using 2D-liquid chromatography-mass spectrometry (LC-MS). The lists of identified proteins were filtered to discover proteins that (i) were found in the tumor but not normal tissue, (ii) were identified in matching plasma, and (iii) whose spectral count was higher in tumor tissue than plasma. These filtering criteria resulted in identification of eight tumor proteins in the blood. Subsequent Western-blot analysis confirmed the presence of cadherin-5, cadherin-11, DEAD-box protein-23, and pyruvate kinase in the blood of the patient in the study as well as in the blood of four other patients diagnosed with RCC. These results demonstrate the utility of a combined blood/tissue analysis strategy that permits the detection of tumor proteins in the blood of a patient diagnosed with RCC.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Carcinoma de Células Renales/sangre , Neoplasias Renales/sangre , Biomarcadores de Tumor/análisis , Carcinoma de Células Renales/diagnóstico , Cromatografía Liquida , Humanos , Neoplasias Renales/diagnóstico , Espectrometría de Masas
20.
J Histochem Cytochem ; 55(7): 763-72, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17409379

RESUMEN

Targeted proteomics research, based on the enrichment of disease-relevant proteins from isolated cell populations selected from high-quality tissue specimens, offers great potential for the identification of diagnostic, prognostic, and predictive biological markers for use in the clinical setting and during preclinical testing and clinical trials, as well as for the discovery and validation of new protein drug targets. Formalin-fixed and paraffin-embedded (FFPE) tissue collections, with attached clinical and outcome information, are invaluable resources for conducting retrospective protein biomarker investigations and performing translational studies of cancer and other diseases. Combined capillary isoelectric focusing/nano-reversed-phase liquid chromatography separations equipped with nano-electrospray ionization-tandem mass spectrometry are employed for the studies of proteins extracted from microdissected FFPE glioblastoma tissues using a heat-induced antigen retrieval (AR) technique. A total of 14,478 distinct peptides are identified, leading to the identification of 2733 non-redundant SwissProt protein entries. Eighty-three percent of identified FFPE tissue proteins overlap with those obtained from the pellet fraction of fresh-frozen tissue of the same patient. This large degree of protein overlapping is attributed to the application of detergent-based protein extraction in both the cell pellet preparation protocol and the AR technique.


Asunto(s)
Proteoma/análisis , Secuencia de Aminoácidos , Neoplasias Encefálicas/metabolismo , Cromatografía Liquida , Reacciones Falso Positivas , Fijadores , Formaldehído , Glioblastoma/metabolismo , Humanos , Focalización Isoeléctrica , Microdisección , Datos de Secuencia Molecular , Adhesión en Parafina , Péptidos/análisis , Espectrometría de Masa por Ionización de Electrospray
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA