Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Phys Rev Lett ; 125(15): 155002, 2020 Oct 09.
Artículo en Inglés | MEDLINE | ID: mdl-33095639

RESUMEN

We present experimental results from the first systematic study of performance scaling with drive parameters for a magnetoinertial fusion concept. In magnetized liner inertial fusion experiments, the burn-averaged ion temperature doubles to 3.1 keV and the primary deuterium-deuterium neutron yield increases by more than an order of magnitude to 1.1×10^{13} (2 kJ deuterium-tritium equivalent) through a simultaneous increase in the applied magnetic field (from 10.4 to 15.9 T), laser preheat energy (from 0.46 to 1.2 kJ), and current coupling (from 16 to 20 MA). Individual parametric scans of the initial magnetic field and laser preheat energy show the expected trends, demonstrating the importance of magnetic insulation and the impact of the Nernst effect for this concept. A drive-current scan shows that present experiments operate close to the point where implosion stability is a limiting factor in performance, demonstrating the need to raise fuel pressure as drive current is increased. Simulations that capture these experimental trends indicate that another order of magnitude increase in yield on the Z facility is possible with additional increases of input parameters.

2.
Trop Anim Health Prod ; 50(8): 1797-1805, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29948775

RESUMEN

The study evaluated small-scale dairy systems with continuous grazing of pastures based on three temperate grasses festulolium (FL), tall fescue (TF), and perennial ryegrass (RG), compared with subtropical kikuyu grass (KG). All pastures were associated with white clover (Trifolium repens L.). Twelve multiparous Holstein cows were assigned to a 4 × 4 Latin square replicated three times with 14-day experimental periods. Sampling and analyses of pastures, concentrates, and animal variables followed standard procedures. FL showed a significantly (p < 0.05) higher mean sward height, but there were no differences (p > 0.05) in net herbage accumulation. There were significant differences (p < 0.05) among pastures for CP, NDF, ADF, in vitro digestibility of OM (IVOMD), and estimated metabolizable energy (eME). There were no differences (p > 0.05) between treatments for milk yield and composition, live weight, or body condition score. There were significant differences (p < 0.05) in fatty acid values for pastures in C14:0, C16:1, and C18:3n3. There were significant differences between treatments (p < 0.05) in milk contents for C18:0, C18:1t11, and C18:2c9t11. Grazing FL, TF, RG, or KY pastures showed no differences in milk yields. Higher values for C18:0, C18:1t11, and C18:2c9t11 were detected in KY, RG, and TF. RG had significantly higher MUFA than FL and higher PUFA than TF. A value under 65% of SFA, a ratio of n-6/n-3 lower than 4, and an atherogenic index of 1.7 are indicators of milk with beneficial effects for human health.


Asunto(s)
Alimentación Animal/análisis , Industria Lechera/métodos , Ácidos Grasos/química , Leche/química , Poaceae , Animales , Bovinos , Femenino , Lactancia , Ácidos Linoleicos Conjugados/química , Lolium , México , Lluvia , Distribución Aleatoria , Estaciones del Año , Trifolium
3.
Phys Rev Lett ; 113(15): 155003, 2014 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-25375714

RESUMEN

This Letter presents results from the first fully integrated experiments testing the magnetized liner inertial fusion concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)], in which a cylinder of deuterium gas with a preimposed 10 Taxial magnetic field is heated by Z beamlet, a 2.5 kJ, 1 TW laser, and magnetically imploded by a 19 MA, 100 ns rise time current on the Z facility. Despite a predicted peak implosion velocity of only 70 km = s, the fuel reaches a stagnation temperature of approximately 3 keV, with T(e) ≈ T(i), and produces up to 2 x 10(12) thermonuclear deuterium-deuterium neutrons. X-ray emission indicates a hot fuel region with full width at half maximum ranging from 60 to 120 µm over a 6 mm height and lasting approximately 2 ns. Greater than 10(10) secondary deuterium-tritium neutrons were observed, indicating significant fuel magnetization given that the estimated radial areal density of the plasma is only 2 mg = cm(2).

4.
Phys Rev Lett ; 113(15): 155004, 2014 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-25375715

RESUMEN

Magnetizing the fuel in inertial confinement fusion relaxes ignition requirements by reducing thermal conductivity and changing the physics of burn product confinement. Diagnosing the level of fuel magnetization during burn is critical to understanding target performance in magneto-inertial fusion (MIF) implosions. In pure deuterium fusion plasma, 1.01 MeV tritons are emitted during deuterium-deuterium fusion and can undergo secondary deuterium-tritium reactions before exiting the fuel. Increasing the fuel magnetization elongates the path lengths through the fuel of some of the tritons, enhancing their probability of reaction. Based on this feature, a method to diagnose fuel magnetization using the ratio of overall deuterium-tritium to deuterium-deuterium neutron yields is developed. Analysis of anisotropies in the secondary neutron energy spectra further constrain the measurement. Secondary reactions also are shown to provide an upper bound for the volumetric fuel-pusher mix in MIF. The analysis is applied to recent MIF experiments [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z Pulsed Power Facility, indicating that significant magnetic confinement of charged burn products was achieved and suggesting a relatively low-mix environment. Both of these are essential features of future ignition-scale MIF designs.

5.
Phys Rev Lett ; 108(21): 215005, 2012 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-23003274

RESUMEN

The National Ignition Facility has been used to compress deuterium-tritium to an average areal density of ~1.0±0.1 g cm(-2), which is 67% of the ignition requirement. These conditions were obtained using 192 laser beams with total energy of 1-1.6 MJ and peak power up to 420 TW to create a hohlraum drive with a shaped power profile, peaking at a soft x-ray radiation temperature of 275-300 eV. This pulse delivered a series of shocks that compressed a capsule containing cryogenic deuterium-tritium to a radius of 25-35 µm. Neutron images of the implosion were used to estimate a fuel density of 500-800 g cm(-3).

6.
Rev Sci Instrum ; 93(10): 103514, 2022 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-36319333

RESUMEN

In inertial confinement fusion experiments, the neutron yield is an important metric for thermonuclear fusion performance. Neutron activation diagnostics can be used to infer neutron yields. The material used for neutron activation diagnostic undergoes a threshold reaction so that only neutrons having energies above the threshold energy are observed. For thermonuclear experiments using deuterium (D) and tritium (T) fuel constituents, neutrons arising from D + D reactions (DD-neutrons) and neutrons resulting from D + T reactions (DT-neutrons) are of primary interest. Indium has two neutron activation reactions that can be used to infer yields of DD-neutrons and DT-neutrons. One threshold is high enough that only DT-neutrons can induce activation, the second reaction can be activated by both DD-neutrons and DT-neutrons. Thus, to obtain the DD-neutron yield, the contribution made by DT-neutrons to the total induced activity must be extracted. In DD-fuel experiments, DT-neutrons arise from secondary reactions, which are significantly lower in number than primary DD-neutrons, and their contribution to the inferred DD-neutron yield can be ignored. When the DD- and DT-neutron yields become comparable, such as when low tritium fractions are added to DD-fuel, the contribution of DT-neutrons must be extracted to obtain accurate yields. A general method is described for this correction to DD-neutron yields.

7.
Rev Sci Instrum ; 93(11): 113531, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461459

RESUMEN

Neutron time-of-flight (nTOF) detectors have been used on Sandia National Laboratories' Z-Machine for inertial confinement fusion and magnetized liner fusion experiments to infer physics parameters including the apparent fuel-ion temperature, neutron yield, the magnetic-radius product (BR), and the liner rho-r. Single-paddle, dual-paddle, and co-axial scintillation nTOF detectors are used in axial lines-of-sight (LOS) and LOS that are 12° from the midplane. Detector fabrication, characterization, and calibration are discussed.

8.
Rev Sci Instrum ; 91(7): 073501, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32752812

RESUMEN

A proof-of-principle CR-39 based neutron-recoil-spectrometer was built and fielded on the Z facility. Data from this experiment match indium activation yields within a factor of 2 using simplified instrument response function models. The data also demonstrate the need for neutron shielding in order to infer liner areal densities. A new shielded design has been developed. The spectrometer is expected to achieve signal-to-background greater than 2 for the down-scattered neutron signal and greater than 30 for the primary signal.

9.
Rev Sci Instrum ; 89(10): 10K122, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399717

RESUMEN

This work illustrates predominant measureable nonlinearities in photomultiplier tubes (PMTs) and introduces a controllable one called "Superlinearity," signifying both a positive nonlinear response and the ability to extend linear operation by counteracting gain saturation mechanisms - charge depletion, space-charge field limitation, and secondary emission surface effects. Recognizing superlinearity and its effect on the temporal step response leads to a true definition of linearity, free of a small-signal linear assumption. Furthermore, given the prevalent use of glass microchannel-plate (MCP) PMTs in favor of a faster impulse response in spite of a small charge limit, we are motivated to examine their nonlinear amplitude response and deploy tailored gain bias string methods to fully harness the maximum linear gain as is usually done for transmissive metal mesh and reflective metal dynode PMTs. Our characterization methodology applies standard NIST-traceable calibrated laboratory equipment with absolute input-referenced techniques, examining step responses over many orders of magnitude in controlled illumination. By doing so, we quantitatively reveal the superlinearity strength independent of charge depletion, yielding true linear responsivity and effectively doubling the small-signal linear limit; this is very relevant to PMT modeling and charge deconvolution efforts. With further development, the tailoring strategies we introduce could be applied to MCP detectors, extracting all useful capillary charge with a significant improvement in large linear signal quality.

10.
Rev Sci Instrum ; 89(10): 10I119, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399763

RESUMEN

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This work describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories' Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 µA beam of 175 keV D+ ions into a stationary ErT2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. The experimental setup and results will be discussed.

11.
Rev Sci Instrum ; 89(10): 10I121, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399775

RESUMEN

The one-dimensional imager of neutrons (ODIN) at the Sandia Z facility consists of a 10-cm block of tungsten with rolled edges, creating a slit imager with slit widths of either 250, 500, or 750 µm. Designed with a 1-m neutron imaging line of sight, we achieve about 4:1 magnification and 500-µm axial spatial resolution. The baseline inertial confinement fusion concept at Sandia is magnetized liner inertial fusion, which nominally creates a 1-cm line source of neutrons. ODIN was designed to determine the size, shape, and location of the neutron producing region, furthering the understanding of compression quality along the cylindrical axis of magnetized liner implosions. Challenges include discriminating neutrons from hard x-rays and gammas with adequate signal-to-noise in the 2 × 1012 deuterium-deuterium (DD) neutron yield range, as well as understanding the point spread function of the imager to various imaging detectors (namely, CR-39). Modeling efforts were conducted with MCNP6.1 to determine neutron response functions for varying configurations in a clean DD neutron environment (without x-rays or gammas). Configuration alterations that will be shown include rolled-edge slit orientation and slit width, affecting the resolution and response function. Finally, the experiment to determine CR-39 neutron sensitivity, with and without a high density polyethylene (n, p) converter, an edge spread function, and resolution will be discussed.

12.
Hybridoma ; 14(4): 369-76, 1995 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8522349

RESUMEN

To test the effect of endogenous pancreatic polypeptide (PP) on rat hepatic glucose homeostasis by immunoneutralization, a rat PP-specific monoclonal antibody (MAb) was produced. Binding of this IgG1 monoclonal antibody was inhibited 50% by 350 pM rat PP. Immunohistochemistry showed that the antibody produced the expected pattern of endocrine cell staining in rat pancreas. Groups of six adult male Sprague-Dawley rats were given 5 mg of Protein-A-purified anti-PP MAb or anti-KLH MAb (control) ip every 48 hr for 5 dosing intervals. The rate of hepatic glucose output during isolated liver perfusion was 0.25 +/- 0.03 mg/g/min for the PP MAb-treated rats and 0.17 +/- 0.02 mg/g/min for the control group (p < 0.05). Liver glycogen content was 21.8 +/- 2.9 mg/g for the PP MAb-treated rats and 14.7 +/- 2.4 mg/g for the control group (N = 5). Chronic in vivo immunoneutralization of PP with this new monoclonal antibody suggests that PP influences glucose homeostasis in the rat by affecting hepatic glucose output.


Asunto(s)
Anticuerpos Monoclonales/biosíntesis , Anticuerpos Monoclonales/fisiología , Glucosa/fisiología , Homeostasis/inmunología , Polipéptido Pancreático/inmunología , Animales , Anticuerpos Monoclonales/farmacología , Especificidad de Anticuerpos/fisiología , Fusión Celular/inmunología , Glucosa/inmunología , Hibridomas , Hígado/inmunología , Hígado/fisiología , Masculino , Ratones , Ratones Endogámicos , Polipéptido Pancreático/fisiología , Ratas , Ratas Sprague-Dawley
13.
Rev Neurol ; 33(2): 123-7, 2001.
Artículo en Español | MEDLINE | ID: mdl-11562870

RESUMEN

INTRODUCTION: The new antiepileptic drugs should also be evaluated outside clinical trials. OBJECTIVE: To study the efficacy of treatment with lamotrigine in everyday neuropaediatric clinical practice. PATIENTS AND METHODS: We made a longitudinal study of all patients treated with lamotrigine in a hospital outpatients department. The efficacy was evaluated by: 1. The number of patients showing partial response (>/=50% reduction in seizures as compared to the basal rate), and total response maintained throughout the follow up period. 2. Duration of treatment, studied using the Kaplan Meier method. RESULTS: 80 patients treated with LTG had as the aetiology of their seizures: idiopathic 3.7%, cryptogenic (51.3%) and symptomatic (45%). We found there to be partial control during the first three months of treatment in 60.8% of the patients, which was maintained after 12 months in 43.1%, and after three years in 30.7%. Total control of the seizures after three months was found in 14.8%, after twelve months in 9.8% and after three years in 3.8%. The probability of treatment with lamotrigine being maintained for six months was 86%, for twelve months 61% and for three years 31%. Lamotrigine was suspended in 38 patients (47.5%). Side effects were reported in five cases. CONCLUSIONS: In clinical practice, the therapeutic effect not only consists of the percentage of patients who respond to treatment, but also the length of time this response is maintained. In our study, both measurements of effect showed results similar to those with classical antiepileptic drugs.


Asunto(s)
Anticonvulsivantes/uso terapéutico , Epilepsia/tratamiento farmacológico , Triazinas/uso terapéutico , Anorexia/inducido químicamente , Anticonvulsivantes/efectos adversos , Ataxia/inducido químicamente , Niño , Preescolar , Erupciones por Medicamentos/etiología , Evaluación de Medicamentos , Resistencia a Medicamentos , Epilepsia/etiología , Femenino , Estudios de Seguimiento , Alucinaciones/inducido químicamente , Humanos , Lamotrigina , Tablas de Vida , Estudios Longitudinales , Masculino , Factores de Tiempo , Resultado del Tratamiento , Triazinas/efectos adversos
14.
Rev Sci Instrum ; 85(11): 11D633, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430209

RESUMEN

An accurate interpretation of DD or DT fusion neutron time-of-flight (nTOF) signals from current mode detectors employed at the Z-facility at Sandia National Laboratories requires that the instrument response functions (IRF's) be deconvolved from the measured nTOF signals. A calibration facility that produces detectable sub-ns radiation pulses is typically used to measure the IRF of such detectors. This work, however, reports on a simple method that utilizes cosmic radiation to measure the IRF of nTOF detectors, operated in pulse-counting mode. The characterizing metrics reported here are the throughput delay and full-width-at-half-maximum. This simple approach yields consistent IRF results with the same detectors calibrated in 2007 at a LINAC bremsstrahlung accelerator (Idaho State University). In particular, the IRF metrics from these two approaches and their dependence on the photomultipliers bias agree to within a few per cent. This information may thus be used to verify if the IRF for a given nTOF detector employed at Z has changed since its original current-mode calibration and warrants re-measurement.

15.
Rev Sci Instrum ; 85(11): 11E617, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430363

RESUMEN

A methodology for obtaining empirical curves relating absolute measured scintillation light output to beta energy deposited is presented. Output signals were measured from thin plastic scintillator using NIST traceable beta and gamma sources and MCNP5 was used to model the energy deposition from each source. Combining the experimental and calculated results gives the desired empirical relationships. To validate, the sensitivity of a beryllium/scintillator-layer neutron activation detector was predicted and then exposed to a known neutron fluence from a Deuterium-Deuterium fusion plasma (DD). The predicted and the measured sensitivity were in statistical agreement.

16.
Rev Sci Instrum ; 85(4): 043507, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24784607

RESUMEN

We present a general methodology to determine the diagnostic sensitivity that is directly applicable to neutron-activation diagnostics fielded on a wide variety of neutron-producing experiments, which include inertial-confinement fusion (ICF), dense plasma focus, and ion beam-driven concepts. This approach includes a combination of several effects: (1) non-isotropic neutron emission; (2) the 1/r(2) decrease in neutron fluence in the activation material; (3) the spatially distributed neutron scattering, attenuation, and energy losses due to the fielding environment and activation material itself; and (4) temporally varying neutron emission. As an example, we describe the copper-activation diagnostic used to measure secondary deuterium-tritium fusion-neutron yields on ICF experiments conducted on the pulsed-power Z Accelerator at Sandia National Laboratories. Using this methodology along with results from absolute calibrations and Monte Carlo simulations, we find that for the diagnostic configuration on Z, the diagnostic sensitivity is 0.037% ± 17% counts/neutron per cm(2) and is ∼ 40% less sensitive than it would be in an ideal geometry due to neutron attenuation, scattering, and energy-loss effects.

17.
Rev Sci Instrum ; 84(7): 073510, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23902066

RESUMEN

A basis set expansion method [V. Dribinski, A. Ossadtchi, V. A. Mandelshtam, and H. Reisler, Rev. Sci. Instrum. 73, 2634 (2002)] is applied to recover physical information about plasma radiation sources from instrument data, which has been forward transformed due to the nature of the measurement technique. This method provides a general approach for inverse problems, and we discuss two specific examples relevant to diagnosing fast z pinches on the 20-25 MA Z machine [M. E. Savage, L. F. Bennett, D. E. Bliss, W. T. Clark, R. S. Coats, J. M. Elizondo, K. R. LeChien, H. C. Harjes, J. M. Lehr, J. E. Maenchen, D. H. McDaniel, M. F. Pasik, T. D. Pointon, A. C. Owen, D. B. Seidel, D. L. Smith, B. S. Stoltzfus, K. W. Struve, W. A. Stygar, L. K. Warne, J. R. Woodworth, C. W. Mendel, K. R. Prestwich, R. W. Shoup, D. L. Johnson, J. P. Corley, K. C. Hodge, T. C. Wagoner, and P. E. Wakeland, in Proceedings of the Pulsed Power Plasma Sciences Conference (IEEE, 2007), p. 979]. First, Abel inversion of time-gated, self-emission x-ray images from a wire array implosion is studied. Second, we present an approach for unfolding neutron time-of-flight measurements from a deuterium gas puff z pinch to recover information about emission time history and energy distribution. Through these examples, we discuss how noise in the measured data limits the practical resolution of the inversion, and how the method handles discontinuities in the source function and artifacts in the projected image. We add to the method a propagation of errors calculation for estimating uncertainties in the inverted solution.

18.
Rev Sci Instrum ; 83(10): 10D914, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126917

RESUMEN

We have performed absolute calibrations of a fusion-neutron-yield copper-activation diagnostic in environments that significantly attenuate and scatter neutrons. We have measured attenuation and scattering effects and have compared the measurements to Monte Carlo simulations using the Monte Carlo N-Particle code. We find that measurements and simulations are consistent within 10%.

19.
Rev Sci Instrum ; 83(10): 10D915, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126918

RESUMEN

A novel method for modeling the neutron time of flight (nTOF) detector response in current mode for inertial confinement fusion experiments has been applied to the on-axis nTOF detectors located in the basement of the Z-Facility. It will be shown that this method can identify sources of neutron scattering, and is useful for predicting detector responses in future experimental configurations, and for identifying potential sources of neutron scattering when experimental set-ups change. This method can also provide insight on how much broadening neutron scattering contributes to the primary signals, which is then subtracted from them. Detector time responses are deconvolved from the signals, allowing a transformation from dN/dt to dN/dE, extracting neutron spectra at each detector location; these spectra are proportional to the absolute yield.

20.
Rev Sci Instrum ; 83(10): 10D913, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126916

RESUMEN

The 350-keV Cockroft-Walton accelerator at Sandia National laboratory's Ion Beam facility is being used to calibrate absolutely a total DT neutron yield diagnostic based on the (63)Cu(n,2n)(62)Cu(ß+) reaction. These investigations have led to first-order uncertainties approaching 5% or better. The experiments employ the associated-particle technique. Deuterons at 175 keV impinge a 2.6 µm thick erbium tritide target producing 14.1 MeV neutrons from the T(d,n)(4)He reaction. The alpha particles emitted are measured at two angles relative to the beam direction and used to infer the neutron flux on a copper sample. The induced (62)Cu activity is then measured and related to the neutron flux. This method is known as the F-factor technique. Description of the associated-particle method, copper sample geometries employed, and the present estimates of the uncertainties to the F-factor obtained are given.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA