Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Oral Investig ; 27(5): 2375-2384, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36640179

RESUMEN

OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AVmax; AVmand). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AVmax/AVmand: 18,060/15,879 mm3) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm3, 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm3, titanium grade 5: 47/35 mm3, gold: 23/21 mm3) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity.


Asunto(s)
Retenedores Ortodóncicos , Titanio , Boca , Imagen por Resonancia Magnética/métodos , Acero Inoxidable , Oro
2.
Eur Radiol ; 30(3): 1488-1497, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31802215

RESUMEN

OBJECTIVES: To evaluate whether magnetic resonance imaging (MRI) can serve as an alternative diagnostic tool to the "gold standard" cone-beam computed tomography (CBCT) in 3D cephalometric analysis. METHODS: In this prospective feasibility study, 12 patients (8 males, 4 females; mean age ± SD, 26.1 years ± 6.6) underwent 3D MRI and CBCT before orthognathic surgery. 3D cephalometric analysis was performed twice by two independent observers on both modalities. For each dataset, 27 cephalometric landmarks were defined from which 35 measurements (17 angles, 18 distances) were calculated. Statistical analyses included the calculation of Euclidean distances, intraclass correlation coefficients (ICCs), Bland-Altman analysis, and equivalence testing (linear mixed effects model) with a predefined equivalence margin of ± 1°/1 mm. RESULTS: Analysis of reliability for CBCT vs. MRI (intra-rater I/intra-rater II/inter-rater) revealed Euclidean distances of 0.86/0.86/0.98 mm vs. 0.93/0.99/1.10 mm for landmarks, ICCs of 0.990/0.980/0.986 vs. 0.982/0.978/0.980 for angles, and ICCs of 0.992/0.988/0.989 vs. 0.991/0.985/0.988 for distances. Bland-Altman analysis showed high levels of agreement between CBCT and MRI with bias values (95% levels of agreement) of 0.03° (- 1.49; 1.54) for angles and 0.02 mm (- 1.44; 1.47) for distances. In the linear mixed effects model, the mean values of CBCT and MRI measurements were equivalent. CONCLUSION: This feasibility study indicates that MRI enables reliable 3D cephalometric analysis with excellent agreement to corresponding measurements on CBCT. Thus, MRI could serve as a non-ionizing alternative to CBCT for treatment planning and monitoring in orthodontics as well as oral and maxillofacial surgery. KEY POINTS: • Clinically established 3D cephalometric measurements performed on MRI are highly reliable and show an excellent agreement with CBCT (gold standard). • The MRI technique applied in this study could be used as a non-ionizing diagnostic tool in orthodontics as well as oral and maxillofacial surgery. • Since most patients benefiting from 3D cephalometry are young in age, the use of MRI could substantially contribute to radiation protection and open up new possibilities for treatment monitoring.


Asunto(s)
Algoritmos , Cefalometría/métodos , Tomografía Computarizada de Haz Cónico/métodos , Anomalías Craneofaciales/diagnóstico , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada de Haz Cónico Espiral/métodos , Adolescente , Adulto , Estudios de Factibilidad , Femenino , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
3.
Clin Oral Investig ; 24(3): 1339-1349, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31352517

RESUMEN

OBJECTIVE: 3D cephalometric analysis performed on cone-beam or multi-slice computed tomography (CBCT, MSCT) has superior diagnostic value compared to 2D cephalometry based on radiographs. However, this comes at the expense of increased radiation risks for the predominantly young patients. Magnetic resonance imaging (MRI) has the potential to overcome this diagnostic dilemma but has not been established for 3D cephalometry so far. Since landmark reliability forms the basis for 3D cephalometry, we evaluated the in vivo reliability of established 3D landmarks using MRI. MATERIALS AND METHODS: Sixteen orthodontic patients underwent MRI at 3 Tesla using a 0.5 mm 3D sequence. On each MRI scan, 44 cephalometric landmarks were determined. Image analysis was performed twice by two independent observers. Intra- and inter-rater agreement was assessed by mean measurement errors and intraclass correlation coefficients (ICCs). Measurement errors were calculated as Euclidean distances and distances for x-, y-, and z-coordinates. RESULTS: Overall, MRI-based 3D cephalometric landmarks revealed a high reliability comparable to prior in vivo studies using CBCT/MSCT. Intra- and inter-rater ICCs were consistently higher than 0.9. Intra-rater comparisons showed mean measurement differences (ranges) of 0.87 mm (0.41-1.63) for rater I and 0.94 mm (0.49-1.28) for rater II. Average inter-rater difference was 1.10 mm (0.52-2.29). Distinct differences in reliability between the various landmarks were observed, corresponding well with the landmarks' specific shapes. CONCLUSIONS: The present study demonstrates that MRI enables reliable determination of 3D cephalometric landmarks in vivo. CLINICAL RELEVANCE: This study emphasizes the potential of MRI to perform treatment planning and monitoring in orthodontics as well as oral and maxillofacial surgery without radiation exposure.


Asunto(s)
Puntos Anatómicos de Referencia , Cefalometría , Imagenología Tridimensional , Imagen por Resonancia Magnética , Adolescente , Adulto , Tomografía Computarizada de Haz Cónico , Estudios de Factibilidad , Femenino , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Adulto Joven
4.
J Orofac Orthop ; 2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36700953

RESUMEN

PURPOSE: To assess magnetic resonance imaging (MRI) artefacts caused by different computer-aided design/computer-aided manufacturing (CAD/CAM) retainers in comparison with conventional hand bent stainless steel twistflex retainers in vivo. MATERIALS AND METHODS: MRI scans (3 Tesla) were performed on a male volunteer with different CAD/CAM retainers (cobalt-chromium, CoCr; nickel-titanium, NiTi; grade 5 titanium, Ti5) and twistflex retainers inserted. A total of 126 landmarks inside and outside the retainer area (RA; from canine to canine) were evaluated by two blinded radiologists using an established five-point visibility scoring (1: excellent, 2: good, 3: moderate, 4: poor, 5: not visible). Friedman and two-tailed Wilcoxon tests were used for statistical analysis (significance level: p < 0.05). RESULTS: Twistflex retainers had the strongest impact on the visibility of all landmarks inside (4.0 ± 1.5) and outside the RA (1.7 ± 1.2). In contrast, artefacts caused by CAD/CAM retainers were limited to the dental area inside the RA (CoCr: 2.2 ± 1.2) or did not impair MRI-based diagnostics in a clinically relevant way (NiTi: 1.0 ± 0.1; Ti5: 1.4 ± 0.6). CONCLUSION: The present study on a single test person demonstrates that conventional stainless steel twistflex retainers can severely impair the diagnostic value in head/neck and dental MRI. By contrast, CoCr CAD/CAM retainers can cause artefacts which only slightly impair dental MRI but not head/neck MRI, whereas NiTi and Ti5 CAD/CAM might be fully compatible with both head/neck and dental MRI.

5.
Invest Radiol ; 57(11): 720-727, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35640007

RESUMEN

OBJECTIVES: The aims of this study were to quantify T1/T2-relaxation times of the dental pulp, develop a realistic tooth model, and compare image quality between cone-beam computed tomography (CBCT) and high-resolution magnetic resonance imaging (MRI) of single teeth using a wireless inductively coupled intraoral coil. METHODS: T1/T2-relaxometry was performed at 3 T in 10 healthy volunteers (283 teeth) to determine relaxation times of healthy dental pulp and develop a realistic tooth model using extracted human teeth. Eight MRI sequences (DESS, CISS, TrueFISP, FLASH, SPACE, TSE, MSVAT-SPACE, and UTE) were optimized for clinically applicable high-resolution imaging of the dental pulp. In model, image quality of all sequences was assessed quantitatively (contrast-to-noise ratio) and qualitatively (visibility of anatomical structures and extent of susceptibility artifacts using a 5-point scoring scale). Cone-beam computed tomography served as the reference modality for qualitative assessment. Statistical analysis was performed using 2-way analysis of variance, Fisher exact test, and Cohen κ. RESULTS: In vivo, relaxometry of dental pulps revealed T1/T2 relaxation times at 3 T of 738 ± 100/171 ± 36 milliseconds. For all sequences, an isotropic resolution of (0.21 mm) 3 was achieved, with acquisition times ranging from 6:19 to 8:02 minutes. In model, the highest contrast-to-noise ratio values were observed for UTE, followed by TSE and CISS. The best image/artifact quality, however, was found for DESS (mean ± SD: 1.3 ± 0.3/2.2 ± 0.0), FLASH (1.5 ± 0.3/2.4 ± 0.1), and CISS (1.5 ± 0.4/2.5 ± 0.1), at a level comparable to CBCT (1.2 ± 0.3/2.1 ± 0.1). CONCLUSIONS: Optimized MRI protocols using an intraoral coil at 3 T can achieve an image quality comparable to reference modality CBCT within clinically applicable acquisition times. Overall, DESS revealed the best results, followed by FLASH and CISS.


Asunto(s)
Tomografía Computarizada de Haz Cónico Espiral , Artefactos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Imagen por Resonancia Magnética/métodos
6.
Sci Rep ; 8(1): 13029, 2018 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-30158656

RESUMEN

The aim of this study was to validate geometric accuracy and in vivo reproducibility of landmark-based cephalometric measurements using high-resolution 3D Magnetic Resonance Imaging (MRI) at 3 Tesla. For accuracy validation, 96 angular and 96 linear measurements were taken on a phantom in 3 different positions. In vivo MRI scans were performed on 3 volunteers in five head positions. For each in vivo scan, 27 landmarks were determined from which 19 angles and 26 distances were calculated. Statistical analysis was performed using Bland-Altman analysis, the two one-sided tests procedure and repeated measures one-way analysis of variance. In comparison to ground truth, all MRI-based phantom measurements showed statistical equivalence (p < 0.001) and an excellent agreement in Bland-Altman analysis (bias ranges: -0.090-0.044°, -0.220-0.241 mm). In vivo cephalometric analysis was highly reproducible among the five different head positions in all study participants, without statistical differences for all angles and distances (p > 0.05). Ranges between maximum and minimum in vivo values were consistently smaller than 2° and 2 mm, respectively (average ranges: 0.88°/0.87 mm). In conclusion, this study demonstrates that accurate and reproducible 3D cephalometric analysis can be performed without exposure to ionizing radiation using MRI.


Asunto(s)
Cefalometría/métodos , Cabeza/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA