Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 100
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Am Heart J ; 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38838970

RESUMEN

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Circulation ; 145(9): 648-658, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34779220

RESUMEN

BACKGROUND: Surgical aortic valve replacement (SAVR) represents a class I indication in symptomatic patients with severe aortic stenosis (AS). However, indications for early SAVR in asymptomatic patients with severe AS and normal left ventricular function remain debated. METHODS: The AVATAR trial (Aortic Valve Replacement Versus Conservative Treatment in Asymptomatic Severe Aortic Stenosis) is an investigator-initiated international prospective randomized controlled trial that evaluated the safety and efficacy of early SAVR in the treatment of asymptomatic patients with severe AS, according to common criteria (valve area ≤1 cm2 with aortic jet velocity >4 m/s or a mean transaortic gradient ≥40 mm Hg), and with normal left ventricular function. Negative exercise testing was mandatory for inclusion. The primary hypothesis was that early SAVR would reduce the primary composite end point of all-cause death, acute myocardial infarction, stroke, or unplanned hospitalization for heart failure compared with a conservative strategy according to guidelines. The trial was designed as event-driven to reach a minimum of 35 prespecified events. The study was performed in 9 centers in 7 European countries. RESULTS: Between June 2015 and September 2020, 157 patients (mean age, 67 years; 57% men) were randomly allocated to early surgery (n=78) or conservative treatment (n=79). Follow-up was completed in May 2021. Overall median follow-up was 32 months: 28 months in the early surgery group and 35 months in the conservative treatment group. There was a total of 39 events, 13 in early surgery and 26 in the conservative treatment group. In the early surgery group, 72 patients (92.3%) underwent SAVR with operative mortality of 1.4%. In an intention-to-treat analysis, patients randomized to early surgery had a significantly lower incidence of primary composite end point than those in the conservative arm (hazard ratio, 0.46 [95% CI, 0.23-0.90]; P=0.02). There was no statistical difference in secondary end points, including all-cause mortality, first heart failure hospitalizations, major bleeding, or thromboembolic complications, but trends were consistent with the primary outcome. CONCLUSIONS: In asymptomatic patients with severe AS, early surgery reduced a primary composite of all-cause death, acute myocardial infarction, stroke, or unplanned hospitalization for heart failure compared with conservative treatment. This randomized trial provides preliminary support for early SAVR once AS becomes severe, regardless of symptoms. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02436655.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
3.
Medicina (Kaunas) ; 59(6)2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37374220

RESUMEN

Sex-related disparities have been recognized in incidence, pathological findings, pathophysiological mechanisms, and diagnostic pathways of non-rheumatic mitral regurgitation. Furthermore, access to treatments and outcomes for surgical and interventional therapies among women and men appears to be different. Despite this, current European and US guidelines have identified common diagnostic and therapeutic pathways that do not consider patient sex in decision-making. The aim of this review is to summarize the current evidence on sex-related differences in non-rheumatic mitral regurgitation, particularly regarding incidence, imaging modalities, surgical-derived evidence, and outcomes of transcatheter edge-to-edge repair, with the goal of informing clinicians about sex-specific challenges to consider when making treatment decisions for patients with mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Caracteres Sexuales , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
4.
Medicina (Kaunas) ; 59(8)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37629726

RESUMEN

Background. Minimally invasive surgery via right mini-thoracotomy has become the standard of care for the treatment of mitral valve disease worldwide, particularly at high-volume centers. In recent years, the spectrum of indications has progressively shifted and extended to fragile and higher-risk patients, also addressing more complex mitral valve disease and ultimately including patients with native or prosthetic infective endocarditis. The rationale for the adoption of the minimally invasive approach is to minimize surgical trauma, promote an earlier postoperative recovery, and reduce the incidence of surgical wound infection and other nosocomial infections. The aim of this retrospective observational study is to evaluate the effectiveness and the early and late outcome in patients undergoing minimally invasive surgery for mitral valve infective endocarditis. Methods. Prospectively collected data regarding minimally invasive surgery in patients with mitral valve infective endocarditis were entered into a dedicated database for the period between January 2007 and December 2022 and retrospectively analyzed. All comers during the study period underwent a preoperative evaluation based on their clinical history and anatomy for the allocation to the most appropriate surgical strategy. The selection of the mini-thoracotomy approach was primarily driven by a thorough transthoracic and especially transesophageal echocardiographic evaluation, coupled with total body and vascular imaging. Results. During the study period, 92 patients underwent right mini-thoracotomy to treat native (80/92, 87%) or prosthetic (12/92, 13%) mitral valve endocarditis at our institution, representing 5% of the patients undergoing minimally invasive mitral surgery. Twenty-six (28%) patients had undergone previous cardiac operations, whereas 18 (20%) presented preoperatively with complications related to endocarditis, most commonly systemic embolization. Sixty-nine and twenty-three patients, respectively, underwent early surgery (75%) or were operated on after the completion of the targeted antibiotic treatment (25%). A conservative procedure was feasible in 16/80 (20%) patients with native valve endocarditis. Conversion to standard sternotomy was necessary in a single case (1.1%). No cases of intraoperative iatrogenic aortic dissection were reported. Four patients died perioperatively, accounting for a thirty-day mortality of 4.4%. The causes of death were refractory heart or multiorgan failure and/or septic shock. A new onset stroke was observed postoperatively in one case (1.1%). Overall actuarial survival rate at 1 and 5 years after operation was 90.8% and 80.4%, whereas freedom from mitral valve reoperation at 1 and 5 years was 96.3% and 93.2%, respectively. Conclusions. This present study shows good early and long-term results in higher-risk patients undergoing minimally invasive surgery for mitral valve infective endocarditis. Total body, vascular, and echocardiographic screening represent the key points to select the optimal approach and allow for the extension of indications for minimally invasive surgery to sicker patients, including active endocarditis and sepsis.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Mitral/cirugía , Estudios Retrospectivos , Nivel de Atención , Endocarditis/cirugía
5.
Catheter Cardiovasc Interv ; 100(1): 122-130, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35485723

RESUMEN

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis. METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints. RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs). CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
6.
J Cardiothorac Vasc Anesth ; 34(8): 2091-2099, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32362544

RESUMEN

OBJECTIVE: To evaluate current results of surgical aortic valve replacement (SAVR) ± coronary artery bypass grafting surgery. DESIGN: Independent, multicenter, prospective registry. SETTING: Tertiary university hospitals. PARTICIPANTS: The study comprised 1,192 consecutive patients, stratified as low-, intermediate-, and high-risk according to EuroSCORE II (<4, 4-9, >9, respectively). INTERVENTIONS: SAVR ± coronary artery bypass grafting surgery. MEASUREMENTS AND MAIN RESULTS: Thirty-day mortality and major morbidity, 2-year actuarial survival and freedom from stroke, and independent predictors of mortality in each risk category were assessed. These data were considered in light of published randomized controlled trials. Thirty-day mortality was 1.0%, 3.0% and 2.1% in the low-, intermediate-, and high-risk patients, with a 2-year actuarial survival of 98.6%, 93.8%, and 94.0%, respectively. Preoperative atrial fibrillation (odds ratio [OR] 8.3), minithoracotomy access (OR 5.8), postoperative dialysis (OR 3.4), type V acute myocardial infarction (OR 20.4), and moderate aortic regurgitation (OR 28.8) predicted 30-day mortality in the low-risk group. Preoperative dialysis (OR 18.3), critical state (OR 36.7), postoperative transfusions of plasma (OR 1.9 per unit transfused), and de-novo dialysis (OR 6.2) predicted 30-day mortality in the intermediate-risk group. Prior cardiac surgery (OR 18.1), postoperative extracorporeal membrane oxygenation (OR 9.8), and gastrointestinal complications (OR 17.2) predicted 30-day mortality in the high-risk group. Although baseline differences existed, low-risk patients demonstrated low 30-day mortality and 30-day to 12-month stroke in light of the PARTNER 3 and EVOLUT Low Risk trial results. Intermediate-risk patients demonstrated low 30-day to 2-year mortality, when the PARTNER 2 trial was considered, and low 30-day to 2-year stroke, when the PARTNER 2 and SURTAVI trials were considered. High-risk patients showed low 30-day to 2-year mortality in light of the results of the PARTNER 1 and CoreValve US trials. CONCLUSIONS: SAVR is still a safe and effective surgery for aortic stenosis regardless of risk category.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Complicaciones Posoperatorias , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
7.
Echocardiography ; 36(9): 1765-1768, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31490562

RESUMEN

The NeoChord procedure is a micro-invasive, trans-ventricular, beating-heart chordal replacement technique for patients with severe degenerative mitral valve regurgitation resulting from prolapsed or flail leaflets. Three dimensional transoesophageal echocardiographic guidance is crucial to assist the operator during the procedure. Equidistant placement of neochordae along the free edge of the prolapsing leaflet segment is important to ensure uniform stress distribution and to avoid damaging any of the previously placed neochordae. Lowering the image gain associated with the three-dimensional surgical view of the mitral valve allows for signal attenuation of the native structures delineating the precise placement location of the neochordae.


Asunto(s)
Cuerdas Tendinosas/diagnóstico por imagen , Cuerdas Tendinosas/cirugía , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Humanos , Interpretación de Imagen Asistida por Computador , Politetrafluoroetileno
8.
Echocardiography ; 36(11): 2090-2093, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31682031

RESUMEN

The NeoChord procedure is an innovative microinvasive, transventricular, beating-heart chordal replacement technique for patients with severe degenerative mitral valve regurgitation resulting from prolapsed or flail leaflets. Use of three-dimensional (3D) transoesophageal echocardiographic imaging is crucial to the physician operator for device navigation during the procedure and to assess the functional results of the repair at the end of the procedure. Photo-realistic, 3D rendering techniques have been recently developed for medical use. Philips TrueVue (Philips Healthcare, Eindhoven, NL) is a photo-realism technique that employs the use of a virtual light source that simulates the interaction of light on 3-dimensional surfaces. Use of photo-realism techniques, in conjunction with 3D echocardiography, improves the visualization of morphological characteristics of the mitral valve before, during, and after beating-heart mitral valve repair procedures.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Cirugía Asistida por Computador/métodos , Ecocardiografía Doppler/métodos , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/etiología , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico , Reproducibilidad de los Resultados
9.
Circulation ; 133(16): 1582-93, 2016 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-26994123

RESUMEN

BACKGROUND: Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. METHODS AND RESULTS: An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II (P<0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. CONCLUSIONS: TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.


Asunto(s)
Bioprótesis/tendencias , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Internacionalidad , Falla de Prótesis/tendencias , Insuficiencia de la Válvula Tricúspide/cirugía , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Bioprótesis/efectos adversos , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación/tendencias , Masculino , Persona de Mediana Edad , Sistema de Registros , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico , Adulto Joven
10.
J Heart Valve Dis ; 26(1): 118-120, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28544842

RESUMEN

A small-sized bioprosthesis can limit transcatheter valve-in-valve (V-in-V) implantations. The case is reported of a 91-year-old woman who had successfully undergone a V-in-V procedure with a 26 mm CoreValve in a previously implanted Mitroflow 19 mm valve. At the five-year follow up the prosthesis showed good echocardiographic function and the patient was alive and free from major symptoms. The patient died three months after the follow up examination at the age of 96 years. This case demonstrates the feasibility, with acceptable longterm functioning, of a V-in-V procedure involving a small bioprosthesis. To the authors' knowledge, the present report is the longest follow up of a patient who underwent V-in-V transcatheter aortic valve implantation in a 19 mm bioprosthesis (15.4 mm internal diameter). Video 1: Preoperative aortography showing moderate-to-severe aortic regurgitation. Video 2: Pre-implantation aortic balloon valvuloplasty. Video 3: Post-deployment aortography showing moderate-to-severe aortic regurgitation. Video 4: The final result. After post-dilation of the under-expanded 26 mm CoreValve, the aortic regurgitation is slightly reduced.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Anciano de 80 o más Años , Válvula Aórtica , Cateterismo Cardíaco , Femenino , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Resultado del Tratamiento
12.
J Heart Valve Dis ; 24(6): 669-678, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27997769

RESUMEN

BACKGROUND: The study aim was to compare the outcome of transapical transcatheter aortic valve replacement (TaTAVR) and traditional aortic valve replacement (AVR) in redo from two real-world registries. METHODS: The 30-day and follow up outcome of 462 patients enrolled in two multicenter redo registries, treated with redo-AVR (RAVR; n = 292 patients) or TaTAVR (n = 170 patients), were analyzed according to VARC-2 criteria, stratified also by propensity-matching analysis. RESULTS: TaTAVR-patients were older and sicker than RAVR patients, and reported a higher all-cause 30-day mortality (p <0.01), a higher risk for all-cause mortality (p = 0.006) and cardiovascular mortality (p = 0.05) at follow up, but similar 30-day cardiovascular mortality (p = 0.12). Prolonged intubation (p <0.01) and Acute Kidney Injury Network (AKIN) 2/3 p = 0.02) prevailed in RAVR. TaTAVR patients reported a higher level of major/life-threatening/disabling bleeding (p <0.01) and 'early safety-events' (ES) (p = 0.04). Thirty-day acute myocardial infarction (AMI), stroke, and follow up freedom from acute heart failure (AHF), from stroke and from reinterventions were similar (p = NS). The NYHA class was better after RAVR (p <0.01). The intermediate-to-high risk (Logistic EuroSCORE RAVR 17.1 ± 8.5; TaTAVR 16.0 ± 17.0) propensity-matched population demonstrated comparable 30-day and follow up all-cause and cardiovascular mortality, ES, AMI, stroke, prolonged intubation, follow up freedom from AHF, from stroke and from reinterventions and NYHA class. TaTAVR still reported lower levels of AKIN 2/3 (2.2% versus 15.6%, p = 0.03) and shorter hospitalization (9.5 ± 3.4 days versus 12.0 ± 7.0 days, p = 0.03). CONCLUSIONS: Outcome differences between RAVR and TaTAVR in redo-scenarios reflect methodological differences and different baseline risk profiles. Propensity-matched patients showed a better renal outcome after TaTAVR. *Drs. Onorati and D'Onofrio contributed equally to this article and should both be considered as first authors.

13.
J Interv Cardiol ; 27(3): 293-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24701998

RESUMEN

AIMS: Impact of periprocedural bleeding after transcatheter aortic valve implantation (TAVI) over mid-term prognosis remains still unclear. METHODS: Consecutive patients who underwent TAVI from May 2008 to July 2012 were prospectively included and stratified according to life-threatening (LT) and major bleeding (MB). Mid-term all-cause death was the primary end-point, and 30-day death, vascular complications, stroke, and acute kidney injury the secondary ones. All end-points were adjudicated according to VARC. RESULTS: Seven hundred fourteen patients with an average age of 81.9 ± 5.8 years were included. 130 (18%) patients suffered a LT, 112 (16%) a MB. A preprocedural GFR <30 ml/min and increasing diameter of sheaths were independent predictors of LT or MB, while transfemoral approach showed a protective effect (OR 0.42; CI: 0.26-0.68; P = 0.035). At 30 days LT (OR 3.3; CI: 1.1-9.7; P = 0.0026) and MB (OR 3.5; CI: 1.4-8.6; P = 0.007) bleeding along with GFR < 30 ml/min (OR 2.3; CI: 1.1-5.5; P = 0.04) were independent predictors of death, while bleeding did not impact survival on mid term (OR 0.9; CI: 0.47-1.7; P = 0.78; all CI 95%). CONCLUSION: Periprocedural bleeding after TAVI was frequent and associated with an increased mortality after 30 days but not after mid-term follow-up. A preprocedural GFR < 30 ml/min was the most important predictor of bleeding, enabling risk stratification and choice of approach for these patients.


Asunto(s)
Lesión Renal Aguda , Estenosis de la Válvula Aórtica/cirugía , Pérdida de Sangre Quirúrgica , Hemorragia Posoperatoria , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Lesión Renal Aguda/diagnóstico , Lesión Renal Aguda/epidemiología , Lesión Renal Aguda/etiología , Anciano , Anciano de 80 o más Años , Pérdida de Sangre Quirúrgica/fisiopatología , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Tasa de Filtración Glomerular , Humanos , Italia/epidemiología , Masculino , Hemorragia Posoperatoria/diagnóstico , Hemorragia Posoperatoria/mortalidad , Hemorragia Posoperatoria/fisiopatología , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/métodos
14.
J Heart Valve Dis ; 23(2): 216-8, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25076553

RESUMEN

Transcatheter aortic valve implantation (TAVI) is sometimes associated with severe complications due to the unpredictability of such closed-chest procedures. Reported complications include atrioventricular blocks, vascular complications, aortic root rupture, aorto-right ventricular fistulas, and aortic dissections. Herein is presented the case of an 88-year-old female with a late atrioventricular septal defect that developed after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/patología , Valvuloplastia con Balón/efectos adversos , Calcinosis/terapia , Cateterismo Cardíaco/efectos adversos , Lesiones Cardíacas/etiología , Tabiques Cardíacos/lesiones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Enfermedad Iatrogénica , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico , Calcinosis/diagnóstico , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Resultado Fatal , Femenino , Lesiones Cardíacas/diagnóstico , Tabiques Cardíacos/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Factores de Tiempo , Tomografía Computarizada por Rayos X
16.
J Clin Med ; 13(11)2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38892855

RESUMEN

Background. Severe tricuspid valve (TV) disease has a strong association with right ventricle dysfunction, heart failure and mortality. Nevertheless, surgical indications for isolated TV disease are still uncommon. The purpose of this study is to analyze outcomes of patients undergoing minimally invasive isolated TV surgery (ITVS). Methods. Data of patients undergoing right mini-thoracotomy ITVS were prospectively collected. A subgroup analysis was performed on late referral patients. Five-year survival was assessed using the Kaplan-Meier survival estimate. Results. Eighty-one consecutive patients were enrolled; late referral was recorded in 8 out of 81 (9.9%). No cases of major vascular complications nor of stroke were reported. A 30-day mortality was reported in one patient (1.2%). Five-year Kaplan-Meier survival analysis revealed a significant difference between late referral patients and the control group (p = 0.01); late referral and Euroscore II were found to be significantly associated with reduced mid-term survival (p = 0.005 and p = 0.01, respectively). Conclusions. To date, perioperative mortality in patients undergoing ITVS is still consistently high, even in high-volume, high-experienced centres, and this accounts for the low rate of referral. Results from our report show that, with proper multidisciplinary management, appropriate pre-operative screening, and allocation to the safest approach, ITVS may offer better results than expected.

17.
JACC Case Rep ; 29(7): 102273, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38645293

RESUMEN

An 84-year-old man presented with dyspnea at rest due to severe mitral regurgitation. He first underwent transventricular mitral valve repair with the Harpoon system, which relapsed owing to rupture of neochords. He was definitively treated with transcatheter mitral valve implantation of the Tendyne system 8 months later.

18.
Minerva Cardiol Angiol ; 72(1): 87-94, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37405712

RESUMEN

BACKGROUND: Even if prevalent among patients with severe aortic stenosis (AS), the clinical suspicion for transthyretin cardiac amyloidosis (ATTR-CA) remains difficult in this subset. We report our single center experience on ATTR-CA detection among TAVR candidates to provide insights on the prevalence and clinical features of dual pathology as compared to lone AS. METHODS: Consecutive severe AS patients undergoing transcatheter aortic valve replacement (TAVR) evaluation at a single center were prospectively included. Those with suspected ATTR-CA based on clinical assessment underwent 99m Tc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) bone scintigraphy. The RAISE score, a novel screening tool with high sensitivity for ATTR-CA in AS, was retrospectively calculated to rule-out ATTR-CA in the remaining patients. Patients were categorized as follow: "ATTR-CA+": patients with confirmed ATTR-CA at DPD bone scintigraphy; "ATTR-CA-": patients with negative DPD bone scintigraphy or a negative RAISE score; "ATTR-CA indeterminate": patients not undergoing ATTR-CA assessment with a positive RAISE score. The characteristics of ATTR-CA+ and ATTR-CA- patients were compared. RESULTS: Of 107 included patients, ATTR-CA suspicion was posed in 13 patients and confirmed in six. Patients were categorized as follow: 6 (5.6%) ATTR-CA+, 79 (73.8%) ATTR-CA-, 22 (20.6%) ATTR-CA indeterminate. Excluding ATTR-CA indeterminate patients, the prevalence of ATTR-CA was 7.1% (95% CI 2.6-14.7%). As compared to ATTR-CA - patients, ATTR-CA + patients were older, had higher procedural risk and more extensive myocardial and renal damage. They had higher left ventricle mass index and lower ECG voltages, translating into a lower voltage to mass ratio. Moreover, we describe for the first time bifascicular block as an ECG feature highly specific of patients with dual pathology (50.0% vs. 2.7%, P<0.001). Of note, pericardial effusion was rarely found in patients with lone AS (16.7% vs. 1.2%, P=0.027). No difference in procedural outcomes was observed between groups. CONCLUSIONS: Among severe AS patients, ATTR-CA is prevalent and presents with phenotypic features that may aid to differentiate it from lone AS. A clinical approach based on routine search of amyloidosis features might lead to selective DPD bone scintigraphy with a satisfactory positive predictive value.


Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Cardiomiopatías , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prealbúmina , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Cardiomiopatías/cirugía , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/epidemiología , Neuropatías Amiloides Familiares/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/cirugía
19.
Echocardiography ; 30(3): 250-7, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23190425

RESUMEN

OBJECTIVE: This study aims to assess changes in mitral regurgitation (MR) severity after transcatheter aortic valve implantation (TAVI). BACKGROUND: Existing data on MR after TAVI are contradictory. METHODS: Thirty-five patients with MR graded ≥ 2+ were followed after undergoing TAVI with either the Edwards Sapien or CoreValve device. Echocardiography was performed the week before and 3 months after the procedure. MR was graded on a scale of 0 to 4+, classified as organic or functional, and the effective regurgitant orifice area (EROA) and MR index were calculated. RESULTS: At baseline, MR was graded 4+ in 4 (11.4%) patients, 3+  in 10 (28.6%), and 2+ in 21 (60%). At follow-up, MR was graded at 3+ in 4 (11.4%) patients, 2+ in 8 (22.9%), and 1+ in 19 (54.3%); 4 (11.4%) exhibited no MR. EROA (24.4 ± 11.5 mm(2) pre-TAVI vs. 11.2 ± 10.3 mm(2) post-TAVI, P < 0.001) and MR index (1.9 ± 0.3 pre-TAVI vs. 1.3 ± 0.7 post-TAVI, P < 0.001) were reduced with TAVI, independent of the etiology. MR decreased by at least 1 grade in 28 (80%) patients, with a reduction ≥2 grades in 10 (28.6%) patients; no patient showed a worsened condition. Subgroup analyses showed that the reduction in MR was significant in patients treated with the Edwards Sapien device but not in patients treated with the CoreValve device. CONCLUSIONS: This multiparametric echocardiographic evaluation showed that MR improved significantly after TAVI and that this result may be related to the type of valve implanted.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía/métodos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Femenino , Humanos , Masculino , Insuficiencia de la Válvula Mitral/complicaciones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Resultado del Tratamiento
20.
Heart Lung Circ ; 22(12): 1036-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23726665

RESUMEN

A 60 year-old female underwent tricuspid valve replacement in 2002. Post-operative recovery was complicated by severe post-pericardiotomy-syndrome. Seven years later she underwent transcatheter valve-in-valve implantation through the right jugular vein because of early prosthesis deterioration. Moreover intra-operative transoesophageal echocardiography showed an important right-to-left shunt through the patent foramen ovale that immediately disappeared after the deployment of a 29-mm Sapien-XT. The patient had an immediate and dramatic improvement in day-by-day activities. This case shows that tricuspid valve deterioration can be safely and successfully treated through this approach.


Asunto(s)
Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Venas Yugulares , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Femenino , Humanos , Persona de Mediana Edad , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA