Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Proc Natl Acad Sci U S A ; 118(52)2021 12 28.
Artículo en Inglés | MEDLINE | ID: mdl-34930834

RESUMEN

Cytoglobin (Cygb) was discovered as a novel type of globin that is expressed in mammals; however, its functions remain uncertain. While Cygb protects against oxidant stress, the basis for this is unclear, and the effect of Cygb on superoxide metabolism is unknown. From dose-dependent studies of the effect of Cygb on superoxide catabolism, we identify that Cygb has potent superoxide dismutase (SOD) function. Initial assays using cytochrome c showed that Cygb exhibits a high rate of superoxide dismutation on the order of 108 M-1 ⋅ s-1 Spin-trapping studies also demonstrated that the rate of Cygb-mediated superoxide dismutation (1.6 × 108 M-1 ⋅ s-1) was only ∼10-fold less than Cu,Zn-SOD. Stopped-flow experiments confirmed that Cygb rapidly dismutates superoxide with rates within an order of magnitude of Cu,Zn-SOD or Mn-SOD. The SOD function of Cygb was inhibited by cyanide and CO that coordinate to Fe3+-Cygb and Fe2+-Cygb, respectively, suggesting that dismutation involves iron redox cycling, and this was confirmed by spectrophotometric titrations. In control smooth-muscle cells and cells with siRNA-mediated Cygb knockdown subjected to extracellular superoxide stress from xanthine/xanthine oxidase or intracellular superoxide stress triggered by the uncoupler, menadione, Cygb had a prominent role in superoxide metabolism and protected against superoxide-mediated death. Similar experiments in vessels showed higher levels of superoxide in Cygb-/- mice than wild type. Thus, Cygb has potent SOD function and can rapidly dismutate superoxide in cells, conferring protection against oxidant injury. In view of its ubiquitous cellular expression at micromolar concentrations in smooth-muscle and other cells, Cygb can play an important role in cellular superoxide metabolism.


Asunto(s)
Citoglobina , Superóxido Dismutasa , Animales , Línea Celular , Citoglobina/química , Citoglobina/genética , Citoglobina/metabolismo , Espectroscopía de Resonancia por Spin del Electrón , Masculino , Ratones , Ratones Noqueados , Especies Reactivas de Oxígeno/metabolismo , Superóxido Dismutasa/química , Superóxido Dismutasa/genética , Superóxido Dismutasa/metabolismo
2.
Magn Reson Med ; 86(4): 2316-2327, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33938574

RESUMEN

PURPOSE: To develop a novel resonator for high-quality fast scan electron paramagnetic resonance (EPR) and EPR/NMR co-imaging of the head and brain of mice at 1.25 GHz. METHODS: Resonator dimensions were scaled to fit the mouse head with maximum filling factor. A single-loop 6-gap resonator of 20 mm diameter and 20 mm length was constructed. High resonator stability was achieved utilizing a fixed position double coupling loop. Symmetrical mutually inverted connections rendered it insensitive to field modulation and fast scan. Coupling adjustment was provided by a parallel-connected variable capacitor located at the feeding line at λ/4 distance. To minimize radiation loss, the shield around the resonator was supplemented with a planar conductive disc that focuses return magnetic flux. RESULTS: Coupling of the resonator loaded with the mouse head was efficient and easy. This resonator enabled high-quality in vivo 3D EPR imaging of the mouse head following intravenous infusion of nitroxide probes. With this resonator and rapid scan EPR system, 4 ms scans were acquired in forward and reverse directions so that images with 2-scan 3,136 projections were acquired in 25 s. Head images were achieved with resolutions of 0.4 mm, enabling visualization of probe localization and uptake across the blood-brain barrier. CONCLUSIONS: This resonator design provides good sensitivity, high stability, and B1 field homogeneity for in vivo fast scan EPR of the mouse head and brain, enabling faster measurements and higher resolution imaging of probe uptake, localization, and metabolism than previously possible.


Asunto(s)
Imagen por Resonancia Magnética , Animales , Espectroscopía de Resonancia por Spin del Electrón , Ratones , Fantasmas de Imagen , Cintigrafía
3.
Inhal Toxicol ; 32(13-14): 477-486, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33256483

RESUMEN

Objectives: To develop and test a new system for whole body exposure of small animals to support investigation of the biological effects of aerosol generated by electronic cigarette (e-cig) products under diverse inhalation conditions with improved control and monitoring of the e-cig vape exposure and nicotine delivered to the animal's systemic circulation. Methods: A computer-controlled design, with built-in sensors for real time monitoring of O2, CO2, relative humidity, and temperature within the exposure chambers and port for measuring total particulate matter (TPM) was developed, constructed and tested. This design accommodates a variety of commercial vaping devices, offers software flexibility to adjust exposure protocols to mimic different users' puffing patterns, enables variable nicotine delivery to the animal's systemic circulation; minimizes travel time and alterations of aerosol quality or quantity by delivering aerosol directly to the exposure chamber, offers local or remote operation of up to six distinct exposure chambers from a single control unit, and can simultaneously test different exposure conditions or products in diverse animal groups, which reduces inter-run variability, saves time, and increases productivity. Results: The time course pattern of TPM concentration during different phases of the exposure cycle was measured. With increased puffing duration or number of exposure cycles, higher TPM exposure and plasma cotinine levels were observed with plasma cotinine levels in the range reported in light or heavy smokers. Conclusion: Overall, this novel, versatile, and durable exposure system facilitates high-throughput evaluation of the relative safety and potential toxicity of a variety of e-cig devices and liquids.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Pruebas de Toxicidad/instrumentación , Administración por Inhalación , Animales , Dióxido de Carbono/análisis , Monóxido de Carbono/análisis , Cotinina/sangre , Diseño de Equipo , Humedad , Masculino , Ratones Endogámicos C57BL , Oxígeno/análisis , Material Particulado/análisis , Material Particulado/toxicidad , Temperatura
4.
Magn Reson Med ; 82(2): 842-853, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31020713

RESUMEN

PURPOSE: In continuous wave EPR imaging, the acquisition of high-quality images was previously limited by the requisite long acquisition times of each image projection that was typically greater than 1 second. To accelerate the process of image acquisition facilitating greater numbers of projections and higher image resolution, instrumentation was developed to greatly accelerate the magnetic field scan that is used to obtain each EPR image projection. METHODS: A low-inductance solenoidal coil for field scanning was used along with a spherical solenoid air core magnet, and scans were driven by triangular symmetric waves, allowing forward and reverse spectrum acquisition as rapid as 3.8 ms. The uniform distribution of projections was used to optimize the contribution of projections for 3D image reconstruction. RESULTS: Using this fast-scan EPR system, high-quality EPR images of phantoms and perfused rat hearts were performed using trityl or nanoparticulate LiNcBuO (lithium octa-n-butoxy-substituted naphthalocyanine) probes with fast-scan EPR imaging at L-band, achieving spatial resolutions of up to 250 micrometers in 1 minute. CONCLUSION: Fast-scan EPR imaging can greatly facilitate the efficient and precise mapping of the spatial distribution of free radical and other paramagnetic probes in living systems.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Animales , Radicales Libres , Corazón/diagnóstico por imagen , Fantasmas de Imagen , Ratas
5.
Bioorg Med Chem Lett ; 26(23): 5685-5688, 2016 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-27836400

RESUMEN

EPR oximetry with the use of trityl radicals can enable sensitive O2 measurement in biological cells and tissues. However, in vitro cellular and in vivo biological applications are limited by rapid trityl probe degradation or biological clearance and the need to enhance probe O2 sensitivity. We synthesized novel perfluorocarbon (PFC) emulsions, ∼200nm droplet size, containing esterified perchlorinated triphenyl methyl (PTM) radicals dispersed in physiological aqueous buffers. These formulations exhibit excellent EPR signal stability, over 20-fold greater than free PTM probes, with high oxygen sensitivity ∼17mG/mmHg enabling pO2 measurement in aqueous solutions or cell suspensions with sensitivity >0.5mmHg. Thus, PFC-PTM probes hold great promise to enable combined O2 delivery and sensing as needed to restore or enhance tissue oxygenation in disease.


Asunto(s)
Emulsiones/química , Fluorocarburos/química , Oximetría/métodos , Oxígeno/análisis , Línea Celular , Espectroscopía de Resonancia por Spin del Electrón , Esterificación , Humanos
6.
Bioorg Med Chem Lett ; 26(7): 1742-4, 2016 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-26923698

RESUMEN

Stable triarylmethyl radicals are ideal spin labels used for biomedical electron paramagnetic resonance applications. Previously reported structures exhibit polar charged functions for water solubilization preventing them from crossing the cell membrane. We report the synthesis of a triarylmethyl radical conjugated to poly-arginine peptide allowing intracellular delivery of the paramagnetic label.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón , Metano/análogos & derivados , Péptidos/síntesis química , Marcadores de Spin/síntesis química , Línea Celular Tumoral , Humanos , Metano/síntesis química , Metano/química , Metano/farmacocinética , Péptidos/química , Péptidos/farmacocinética
7.
Anal Chem ; 86(2): 1045-52, 2014 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-24372284

RESUMEN

A variable radio frequency proton-electron double-resonance imaging (VRF PEDRI) approach for pH mapping of aqueous samples has been recently developed (Efimova et al. J. Magn. Reson. 2011, 209, 227-232). A pH map is extracted from two PEDRI acquisitions performed at electron paramagnetic resonance (EPR) frequencies of protonated and unprotonated forms of a pH-sensitive probe. To translate VRF PEDRI to an in vivo setting, an advanced pH probe was synthesized. Probe deuteration resulted in a narrow spectral line of 1.2 G compared to a nondeuterated analogue line width of 2.1 G allowing for an increase of Overhauser enhancements and reduction in rf power deposition. Binding of the probe to the cell-impermeable tripeptide, glutathione (GSH), allows for targeting to extracellular tissue space for monitoring extracellular tumor acidosis, a prognostic factor in tumor pathophysiology. The probe demonstrated pH sensitivity in the 5.8-7.8 range, optimum for measurement of acidic extracellular tumor pH (pH(e)). In vivo VRF PEDRI was performed on Met-1 tumor-bearing mice. Compared to normal mammary glands with a neutral mean pH(e) (7.1 ± 0.1), we observed broader pH distribution with acidic mean pH(e) (6.8 ± 0.1) in tumor tissue. In summary, VRF PEDRI in combination with a newly developed pH probe provides an analytical approach for spatially resolved noninvasive pHe monitoring, in vivo.


Asunto(s)
Óxidos N-Cíclicos , Diagnóstico por Imagen/métodos , Espectroscopía de Resonancia por Spin del Electrón/métodos , Neoplasias Mamarias Experimentales/química , Marcadores de Spin , Animales , Neoplasias de la Mama , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Óxidos N-Cíclicos/síntesis química , Óxidos N-Cíclicos/farmacología , Electrones , Femenino , Glutatión/química , Humanos , Concentración de Iones de Hidrógeno , Neoplasias Mamarias Experimentales/diagnóstico , Ratones , Ratones Endogámicos C57BL , Fantasmas de Imagen , Protones , Marcadores de Spin/síntesis química , Agua/química
8.
Magn Reson Med ; 72(3): 893-901, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24123102

RESUMEN

PURPOSE: To improve image quality and reduce data requirements for spatial electron paramagnetic resonance imaging (EPRI) by developing a novel reconstruction approach using compressed sensing (CS). METHODS: EPRI is posed as an optimization problem, which is solved using regularized least-squares with sparsity promoting penalty terms, consisting of the l1 norms of the image itself and the total variation of the image. Pseudo-random sampling was employed to facilitate recovery of the sparse signal. The reconstruction was compared with the traditional filtered back-projection reconstruction for simulations, phantoms, isolated rat hearts, and mouse gastrointestinal (GI) tracts labeled with paramagnetic probes. RESULTS: A combination of pseudo-random sampling and CS was able to generate high-fidelity EPR images at high acceleration rates. For three-dimensional (3D) phantom imaging, CS-based EPRI showed little visual degradation at nine-fold acceleration. In rat heart datasets, CS-based EPRI produced high quality images with eight-fold acceleration. A high resolution mouse GI tract reconstruction demonstrated a visual improvement in spatial resolution and a doubling in signal-to-noise ratio (SNR). CONCLUSION: A novel 3D EPRI reconstruction using compressed sensing was developed and offers superior SNR and reduced artifacts from highly undersampled data.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón/métodos , Algoritmos , Animales , Compresión de Datos , Corazón/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Intestinos/anatomía & histología , Ratones , Fantasmas de Imagen , Ratas
9.
Magn Reson Med ; 71(2): 893-900, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23475830

RESUMEN

PURPOSE: To improve the quality and speed of electron paramagnetic resonance imaging (EPRI) acquisition by combining a uniform sampling distribution with spinning gradient acquisition. THEORY AND METHODS: A uniform sampling distribution was derived for spinning gradient EPRI acquisition (uniform spinning sampling, USS) and compared to the existing (equilinear spinning sampling, ESS) acquisition strategy. Novel corrections were introduced to reduce artifacts in experimental data. RESULTS: Simulations demonstrated that USS puts an equal number of projections near each axis whereas ESS puts excessive projections at one axis, wasting acquisition time. Artifact corrections added to the magnetic gradient waveforms reduced noise and correlation between projections. USS images had higher SNR (85.9 ± 0.8 vs. 56.2 ± 0.8) and lower mean-squared error than ESS images. The quality of the USS images did not vary with the magnetic gradient orientation, in contrast to ESS images. The quality of rat heart images was improved using USS compared to that with ESS or traditional fast-scan acquisitions. CONCLUSION: A novel EPRI acquisition which combines spinning gradient acquisition with a uniform sampling distribution was developed. This USS spinning gradient acquisition offers superior SNR and reduced artifacts compared to prior methods enabling potential improvements in speed and quality of EPR imaging in biological applications.


Asunto(s)
Algoritmos , Artefactos , Espectroscopía de Resonancia por Spin del Electrón/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen Molecular/métodos , Humanos , Reproducibilidad de los Resultados , Tamaño de la Muestra , Sensibilidad y Especificidad , Marcadores de Spin
10.
Appl Magn Reson ; 45(9): 817-826, 2014 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-25530673

RESUMEN

Variable Radio Frequency Proton-Electron Double-Resonance Imaging (VRF PEDRI) enables extracting a functional map from a limited number of images acquired at pre-selected EPR frequencies using specifically designed paramagnetic probes with high quality spatial resolution and short acquisition times. In this work we explored potential of VRF PEDRI for pH mapping of aqueous samples using recently synthesized pH-sensitive phosphonated trityl radical, pTR. The ratio of Overhauser enhancements measured at each pixel at two different excitation frequencies corresponding to the resonances of protonated and deprotonated forms of pTR probe allows for a pH map extraction. Long relaxation times of pTR allow for pH mapping at EPR irradiation power as low as 1.25 W during 130 s acquisition time with spatial resolution of about 1 mm. This is particularly important for in vivo applications enabling one to avoid sample overheating by reducing RF power deposition.

11.
Magn Reson Med ; 69(2): 594-601, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22473660

RESUMEN

In vivo or ex vivo electron paramagnetic resonance imaging (EPRI) is a powerful technique for determining the spatial distribution of free radicals and other paramagnetic species in living organs and tissues. However, applications of EPRI have been limited by long projection acquisition times and the consequent fact that rapid gated EPRI was not possible. Hence in vivo EPRI typically provided only time-averaged information. In order to achieve direct gated EPRI, a fast EPR acquisition scheme was developed to decrease EPR projection acquisition time down to 10-20 ms, along with corresponding software and instrumentation to achieve fast gated EPRI of the isolated beating heart with submillimeter spatial resolution in as little as 2-3 min. Reconstructed images display temporal and spatial variations of the free-radical distribution, anatomical structure, and contractile function within the rat heart during the cardiac cycle.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Espectroscopía de Resonancia por Spin del Electrón/métodos , Radicales Libres/metabolismo , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Contracción Miocárdica/fisiología , Miocardio/metabolismo , Animales , Técnicas In Vitro , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
J Natl Cancer Inst ; 115(11): 1404-1419, 2023 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-37195421

RESUMEN

BACKGROUND: We investigated the role of A2B-adenosine receptor in regulating immunosuppressive metabolic stress in the tumor microenvironment. Novel A2B-adenosine receptor antagonist PBF-1129 was tested for antitumor activity in mice and evaluated for safety and immunologic efficacy in a phase I clinical trial of patients with non-small cell lung cancer. METHODS: The antitumor efficacy of A2B-adenosine receptor antagonists and their impact on the metabolic and immune tumor microenvironment were evaluated in lung, melanoma, colon, breast, and epidermal growth factor receptor-inducible transgenic cancer models. Employing electron paramagnetic resonance, we assessed changes in tumor microenvironment metabolic parameters, including pO2, pH, and inorganic phosphate, during tumor growth and evaluated the immunologic effects of PBF-1129, including its pharmacokinetics, safety, and toxicity, in patients with non-small cell lung cancer. RESULTS: Levels of metabolic stress correlated with tumor growth, metastasis, and immunosuppression. Tumor interstitial inorganic phosphate emerged as a correlative and cumulative measure of tumor microenvironment stress and immunosuppression. A2B-adenosine receptor inhibition alleviated metabolic stress, downregulated expression of adenosine-generating ectonucleotidases, increased expression of adenosine deaminase, decreased tumor growth and metastasis, increased interferon γ production, and enhanced the efficacy of antitumor therapies following combination regimens in animal models (anti-programmed cell death 1 protein vs anti-programmed cell death 1 protein plus PBF-1129 treatment hazard ratio = 11.74 [95% confidence interval = 3.35 to 41.13], n = 10, P < .001, 2-sided F test). In patients with non-small cell lung cancer, PBF-1129 was well tolerated, with no dose-limiting toxicities; demonstrated pharmacologic efficacy; modulated the adenosine generation system; and improved antitumor immunity. CONCLUSIONS: Data identify A2B-adenosine receptor as a valuable therapeutic target to modify metabolic and immune tumor microenvironment to reduce immunosuppression, enhance the efficacy of immunotherapies, and support clinical application of PBF-1129 in combination therapies.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Animales , Ratones , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Receptor de Adenosina A2B/metabolismo , Microambiente Tumoral , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/patología , Terapia de Inmunosupresión , Adenosina/metabolismo , Fosfatos , Línea Celular Tumoral
13.
Magn Reson Med ; 67(6): 1827-36, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22113626

RESUMEN

Approach for in vivo real-time assessment of tumor tissue extracellular pH (pH(e)), redox, and intracellular glutathione based on L-band EPR spectroscopy using dual function pH and redox nitroxide probe and disulfide nitroxide biradical, is described. These parameters were monitored in PyMT mice bearing breast cancer tumors during treatment with granulocyte macrophage colony-stimulating factor. It was observed that tumor pH(e) is about 0.4 pH units lower than that in normal mammary gland tissue. Treatment with granulocyte macrophage colony-stimulating factor decreased the value of pH(e) by 0.3 units compared with PBS control treatment. Tumor tissue reducing capacity and intracellular glutathione were elevated compared with normal mammary gland tissue. Granulocyte macrophage colony-stimulating factor treatment resulted in a decrease of the tumor tissue reducing capacity and intracellular glutathione content. In addition to spectroscopic studies, pH(e) mapping was performed using recently proposed variable frequency proton-electron double-resonance imaging. The pH mapping superimposed with MRI image supports probe localization in mammary gland/tumor tissue, shows high heterogeneity of tumor tissue pH(e) and a difference of about 0.4 pH units between average pH(e) values in tumor and normal mammary gland. In summary, the developed multifunctional approach allows for in vivo, noninvasive pH(e), extracellular redox, and intracellular glutathione content monitoring during investigation of various therapeutic strategies for solid tumors.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/tratamiento farmacológico , Espectroscopía de Resonancia por Spin del Electrón/métodos , Glutatión/análisis , Factor Estimulante de Colonias de Granulocitos y Macrófagos/uso terapéutico , Animales , Biomarcadores/análisis , Neoplasias de la Mama/metabolismo , Línea Celular Tumoral , Femenino , Concentración de Iones de Hidrógeno , Ratones , Oxidación-Reducción , Pronóstico , Resultado del Tratamiento
14.
Am J Hypertens ; 35(4): 347-355, 2022 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-34694354

RESUMEN

BACKGROUND: The mechanism and markers of cardiovascular disease (CVD) in obstructive sleep apnea (OSA) remain unknown. The microcirculation is the site of early changes in OSA patients who are free of CVD risk. METHODS: Patients with newly diagnosed moderate to severe OSA (n = 7) were studied before and 12 weeks after intensive treatment with continuous positive airway pressure (CPAP), along with weight and age matched controls (n = 7). Microcirculatory vessels were isolated from gluteal biopsies and changes in critical functional genes were measured. RESULTS: The following genes changed after 12 weeks of intensive CPAP therapy in the microcirculatory vessels: angiotensin receptor type 1 (AGTR-1) (11.6 (3.4) to 6 (0.8); P = 0.019); NADPH oxidase (NOX4) (0.85 (0.02) to 0.79 (0.11); P = 0.016); and dimethylarginine dimethylaminohydrolase (DDAH 1) (1 (0.31) to 0.55 (0.1); P = 0.028). Despite decreased nitric oxide (NO) availability as measured indirectly through brachial artery flow-mediated dilation, endothelial NO synthase (NOS3) did not change with CPAP. Other disease markers of OSA that changed with treatment in the microcirculation were endothelin, hypoxia inducible factor 1a, nuclear factor kappa B, interleukin-8, and interleukin-6. CONCLUSIONS: In this ex vivo evaluation of the microcirculation of patients with OSA and no CVD risk, several pathways of CVD were activated supporting that OSA independently induces microcirculatory endothelial dysfunction and serving as disease-specific markers for future pharmacological targeting of OSA-related CVD risk. The findings support the role of renin-angiotensin activation and endothelial oxidative stress in the decreased microcirculatory NO availability in OSA.


Asunto(s)
Apnea Obstructiva del Sueño , Arteria Braquial , Presión de las Vías Aéreas Positiva Contínua , Humanos , Microcirculación , Óxido Nítrico , Apnea Obstructiva del Sueño/complicaciones , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia
15.
J Magn Reson ; 329: 107024, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34198184

RESUMEN

Linearity of the magnetic field sweep is important for high resolution continuous wave EPR imaging. Driving the field with triangular wave function is the most efficient way to scan EPR projections. However, the magnetic field sweep profile can be significantly distorted during fast millisecond projection scan. In this work, we introduce a method to generate highly linear and properly symmetrical triangular sweeps of the magnetic field using calibrated harmonics of the triangular wave function. First, the frequency response function of the EPR magnet and its power circuitry was obtained. For this, the field sweeping coil was driven with sinusoidal signals of different frequencies and the actual magnetic field inside the magnet was recorded. To cover wide range of frequencies, the measurements were carried out independently using gaussmeter, Hall-effect linear sensor integrated circuit, and an inductance coil. For each frequency, the system gain and the phase delay were determined. These data were used to adjust the amplitudes and the phases of individual harmonics of the triangular wave function. After the calibration, the maximum deviation of the magnetic field from the linear function was 0.05% of sweep width for 4 ms scan. The maximum discrepancy between the forward and the reverse scan was less than 0.04%. Sweep overhead time for changing the scan direction was 5%. The proposed approach allows generation of high fidelity triangular magnetic field sweeps with accuracy better than 0.1% for the range of the magnetic field sweep widths up to 48 G and scan duration from 10 s down to 1 ms.


Asunto(s)
Diagnóstico por Imagen , Campos Magnéticos , Espectroscopía de Resonancia por Spin del Electrón
16.
Nitric Oxide ; 22(2): 83-90, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-20044016

RESUMEN

Nitric oxide (NO) is an important regulator of a variety of biological functions, and also has a role in the pathogenesis of cellular injury. It had been generally accepted that NO is solely generated in biological tissues by specific nitric oxide synthases (NOS) which metabolize arginine to citrulline with the formation of NO. However, over the last 15 years, nitrite-mediated NO production has been shown to be an important mechanism of NO formation in the heart and cardiovascular system. Now numerous studies have demonstrated that nitrite can be an important source rather than simply a product of NO in mammalian cells and tissues and can be a potential vasodilator drug for cardiovascular diseases. There are a variety of mechanisms of nitrite reduction to NO and it is now appreciated that this process, while enhanced under hypoxic conditions, also occurs under normoxia. Several methods, including electron paramagnetic resonance, chemiluminescence NO analyzer, and NO electrode have been utilized to measure, quantitate, and image nitrite-mediated NO formation. Results reveal that nitrite-dependent NO generation plays critical physiological and pathological roles, and is controlled by oxygen tension, pH, reducing substrates and nitrite levels. In this manuscript, we review the mechanisms of nitrite-mediated NO formation and the effects of oxygen on this process with a focus on how this occurs in the heart and vessels.


Asunto(s)
Vasos Sanguíneos/metabolismo , Corazón , Óxido Nítrico/biosíntesis , Nitritos/metabolismo , Animales , Humanos , Óxido Nítrico/metabolismo , Oxidación-Reducción
17.
J Magn Reson ; 319: 106812, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32966948

RESUMEN

A novel method for reconstructing 3D spatial EPR images from large numbers of noisy projections was developed that minimizes mean square error between the experimental projections and those from the reconstructed image. The method utilizes raw projection data and zero gradient spectrum to account for EPR line shape and hyperfine structure of the paramagnetic probe without the need for deconvolution techniques that are poorly suited for processing of high noise projections. A numerical phantom was reconstructed for method validation. Reconstruction time for the matrix of 1283 voxels and 16,384 noiseless projections was 4.6 min for a single iteration. The algorithm converged quickly, reaching R2 ~ 0.99975 after the very first iteration. An experimental phantom sample with nitroxyl radical was measured. With 16,384 projections and a field gradient of 8 G/cm, resolutions of 0.4 mm were achieved for a cubical area of 25 × 25 × 25 mm3. Reconstruction was sufficiently fast and memory efficient making it suitable for applications with large 3D matrices and fully determined system of equations. The developed algorithm can be used with any gradient distribution and does not require adjustable filter parameters that makes for simple application. A thorough analysis of the strengths and limitations of this method for 3D spatial EPR imaging is provided.


Asunto(s)
Espectroscopía de Resonancia por Spin del Electrón , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Algoritmos , Fantasmas de Imagen
18.
Med Res Rev ; 29(5): 683-741, 2009 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-19219851

RESUMEN

In this review we consider the effects of endogenous and pharmacological levels of nitrite under conditions of hypoxia. In humans, the nitrite anion has long been considered as metastable intermediate in the oxidation of nitric oxide radicals to the stable metabolite nitrate. This oxidation cascade was thought to be irreversible under physiological conditions. However, a growing body of experimental observations attests that the presence of endogenous nitrite regulates a number of signaling events along the physiological and pathophysiological oxygen gradient. Hypoxic signaling events include vasodilation, modulation of mitochondrial respiration, and cytoprotection following ischemic insult. These phenomena are attributed to the reduction of nitrite anions to nitric oxide if local oxygen levels in tissues decrease. Recent research identified a growing list of enzymatic and nonenzymatic pathways for this endogenous reduction of nitrite. Additional direct signaling events not involving free nitric oxide are proposed. We here discuss the mechanisms and properties of these various pathways and the role played by the local concentration of free oxygen in the affected tissue.


Asunto(s)
Hipoxia/metabolismo , Óxido Nítrico/metabolismo , Nitritos/metabolismo , Oxígeno/metabolismo , Transducción de Señal , Animales , Humanos , Nitratos/sangre , Nitratos/metabolismo , Óxido Nítrico Sintasa de Tipo III/metabolismo , Nitritos/sangre , Oxidación-Reducción , Oxígeno/sangre , Ratas , Daño por Reperfusión/metabolismo , Vasodilatación/fisiología
19.
J Magn Reson ; 188(1): 68-73, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17625940

RESUMEN

For whole body EPR imaging of small animals, typically low frequencies of 250-750 MHz have been used due to the microwave losses at higher frequencies and the challenges in designing suitable resonators to accommodate these large lossy samples. However, low microwave frequency limits the obtainable sensitivity. L-band frequencies can provide higher sensitivity, and have been commonly used for localized in vivo EPR spectroscopy. Therefore, it would be highly desirable to develop an L-band microwave resonator suitable for in vivo whole body EPR imaging of small animals such as living mice. A 1.2 GHz 16-gap resonator with inner diameter of 42 mm and 48 mm length was designed and constructed for whole body EPR imaging of small animals. The resonator has good field homogeneity and stability to animal-induced motional noise. Resonator stability was achieved with electrical and mechanical design utilizing a fixed position double coupling loop of novel geometry, thus minimizing the number of moving parts. Using this resonator, high quality EPR images of lossy phantoms and living mice were obtained. This design provides good sensitivity, ease of sample access, excellent stability and uniform B(1) field homogeneity for in vivo whole body EPR imaging of mice at 1.2 GHz.


Asunto(s)
Algoritmos , Espectroscopía de Resonancia por Spin del Electrón/instrumentación , Espectroscopía de Resonancia por Spin del Electrón/métodos , Animales , Ratones , Ondas de Radio
20.
J Magn Reson ; 273: 105-112, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27821290

RESUMEN

Electron paramagnetic resonance (EPR) allows quantitative imaging of tissue redox status, which provides important information about ischemic syndromes, cancer and other pathologies. For continuous wave EPR imaging, however, poor signal-to-noise ratio and low acquisition efficiency limit its ability to image dynamic processes in vivo including tissue redox, where conditions can change rapidly. Here, we present a data acquisition and processing framework that couples fast acquisition with compressive sensing-inspired image recovery to enable EPR-based redox imaging with high spatial and temporal resolutions. The fast acquisition (FA) allows collecting more, albeit noisier, projections in a given scan time. The composite regularization based processing method, called spatio-temporal adaptive recovery (STAR), not only exploits sparsity in multiple representations of the spatio-temporal image but also adaptively adjusts the regularization strength for each representation based on its inherent level of the sparsity. As a result, STAR adjusts to the disparity in the level of sparsity across multiple representations, without introducing any tuning parameter. Our simulation and phantom imaging studies indicate that a combination of fast acquisition and STAR (FASTAR) enables high-fidelity recovery of volumetric image series, with each volumetric image employing less than 10 s of scan. In addition to image fidelity, the time constants derived from FASTAR also match closely to the ground truth even when a small number of projections are used for recovery. This development will enhance the capability of EPR to study fast dynamic processes that cannot be investigated using existing EPR imaging techniques.


Asunto(s)
Diagnóstico por Imagen , Espectroscopía de Resonancia por Spin del Electrón , Fantasmas de Imagen , Compresión de Datos , Oxidación-Reducción , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA