Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Radiol ; 177: 111588, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38944907

RESUMEN

OBJECTIVES: To develop and validate an open-source deep learning model for automatically quantifying scapular and glenoid morphology using CT images of normal subjects and patients with glenohumeral osteoarthritis. MATERIALS AND METHODS: First, we used deep learning to segment the scapula from CT images and then to identify the location of 13 landmarks on the scapula, 9 of them to establish a coordinate system unaffected by osteoarthritis-related changes, and the remaining 4 landmarks on the glenoid cavity to determine the glenoid size and orientation in this scapular coordinate system. The glenoid version, glenoid inclination, critical shoulder angle, glenopolar angle, glenoid height, and glenoid width were subsequently measured in this coordinate system. A 5-fold cross-validation was performed to evaluate the performance of this approach on 60 normal/non-osteoarthritic and 56 pathological/osteoarthritic scapulae. RESULTS: The Dice similarity coefficient between manual and automatic scapular segmentations exceeded 0.97 in both normal and pathological cases. The average error in automatic scapular and glenoid landmark positioning ranged between 1 and 2.5 mm and was comparable between the automatic method and human raters. The automatic method provided acceptable estimates of glenoid version (R2 = 0.95), glenoid inclination (R2 = 0.93), critical shoulder angle (R2 = 0.95), glenopolar angle (R2 = 0.90), glenoid height (R2 = 0.88) and width (R2 = 0.94). However, a significant difference was found for glenoid inclination between manual and automatic measurements (p < 0.001). CONCLUSIONS: This open-source deep learning model enables the automatic quantification of scapular and glenoid morphology from CT scans of patients with glenohumeral osteoarthritis, with sufficient accuracy for clinical use.


Asunto(s)
Aprendizaje Profundo , Osteoartritis , Escápula , Articulación del Hombro , Tomografía Computarizada por Rayos X , Humanos , Escápula/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Osteoartritis/diagnóstico por imagen , Masculino , Femenino , Articulación del Hombro/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Cavidad Glenoidea/diagnóstico por imagen , Adulto , Reproducibilidad de los Resultados , Puntos Anatómicos de Referencia/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA