Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 49(3): 992-1001, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34476552

RESUMEN

PURPOSE: To compare CT, MRI, and [18F]-fluorodeoxyglucose positron emission tomography ([18F]-FDG PET/MRI) for nodal status, regarding quantity and location of metastatic locoregional lymph nodes in patients with newly diagnosed breast cancer. MATERIALS AND METHODS: One hundred eighty-two patients (mean age 52.7 ± 11.9 years) were included in this prospective double-center study. Patients underwent dedicated contrast-enhanced chest/abdomen/pelvis computed tomography (CT) and whole-body ([18F]-FDG PET/) magnet resonance imaging (MRI). Thoracal datasets were evaluated separately regarding quantity, lymph node station (axillary levels I-III, supraclavicular, internal mammary chain), and lesion character (benign vs. malign). Histopathology served as reference standard for patient-based analysis. Patient-based and lesion-based analyses were compared by a McNemar test. Sensitivity, specificity, positive and negative predictive values, and accuracy were assessed for all three imaging modalities. RESULTS: On a patient-based analysis, PET/MRI correctly detected significantly more nodal positive patients than MRI (p < 0.0001) and CT (p < 0.0001). No statistically significant difference was seen between CT and MRI. PET/MRI detected 193 lesions in 75 patients (41.2%), while MRI detected 123 lesions in 56 patients (30.8%) and CT detected 104 lesions in 50 patients, respectively. Differences were statistically significant on a lesion-based analysis (PET/MRI vs. MRI, p < 0.0001; PET/MRI vs. CT, p < 0.0001; MRI vs. CT, p = 0.015). Subgroup analysis for different lymph node stations showed that PET/MRI detected significantly more lymph node metastases than MRI and CT in each location (axillary levels I-III, supraclavicular, mammary internal chain). MRI was superior to CT only in axillary level I (p = 0.0291). CONCLUSION: [18F]-FDG PET/MRI outperforms CT or MRI in detecting nodal involvement on a patient-based analysis and on a lesion-based analysis. Furthermore, PET/MRI was superior to CT or MRI in detecting lymph node metastases in all lymph node stations. Of all the tested imaging modalities, PET/MRI showed the highest sensitivity, whereas CT showed the lowest sensitivity, but was most specific.


Asunto(s)
Neoplasias de la Mama , Fluorodesoxiglucosa F18 , Adulto , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Estudios Prospectivos , Radiofármacos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
2.
BMC Med Imaging ; 22(1): 63, 2022 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-35379187

RESUMEN

PURPOSE: While 18F-FDG PET/CT yields valuable prognostic information for patients in first-line therapy of multiple myeloma (MM), its prognostic relevance in relapse is not established. Available studies of relapsed MM describe prognostic thresholds for frequently used PET/CT parameters that are significantly higher than those identified in the first-line setting. The purpose of this study was to evaluate the prognostic role of PET/CT in relapsed MM, based on parameters used in the first-line setting. METHODS: Our retrospective study included 36 patients with MM who had received autologous or allogeneic stem cell transplantation, suffered at least one relapse, and underwent FDG-PET/CT at relapse. Number of focal bone lesions (FL), maximal standardised uptake value (SUVmax), and presence of PET-positive extramedullary lesions (EMD) were analysed. RESULTS: For the number of FLs, the prognostic value was demonstrated with a cut-off of > 3 (median OS 3.8 months vs. not reached, p = 0.003). Median OS of patients with SUVmax ≤ 4 was not reached, while it was 3.9 months in patients with SUVmax > 4 (p = 0.014). Presence of EMD was a significant prognostic parameter too, with median OS of 3.6 months versus not reached (p = 0.004). The above-mentioned parameters showed prognostic significance for PFS as well. Combination of higher ISS stage and PET/CT parameters identified patients with particularly short OS (3.7 months vs. not reached, p < 0.001) and PFS (3.6 vs. 11.7 months p < 0.001). CONCLUSION: The PET/CT parameters SUVmax > 4, nFL > 3, and presence of EMD identify patients with poor prognosis not only in the first-line setting but also in relapsed MM.


Asunto(s)
Fluorodesoxiglucosa F18 , Mieloma Múltiple , Humanos , Mieloma Múltiple/diagnóstico por imagen , Mieloma Múltiple/tratamiento farmacológico , Tomografía Computarizada por Tomografía de Emisión de Positrones , Pronóstico , Estudios Retrospectivos
3.
Eur J Nucl Med Mol Imaging ; 48(12): 3975-3989, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33760957

RESUMEN

PURPOSE: The advent of immune checkpoint inhibitors (ICIs) has revolutionized the treatment of advanced NSCLC, leading to a string of approvals in recent years. Herein, a narrative review on the role of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in the ever-evolving treatment landscape of advanced NSCLC is presented. METHODS: This comprehensive review will begin with an introduction into current treatment paradigms incorporating ICIs; the evolution of CT-based criteria; moving onto novel phenomena observed with ICIs and the current state of hybrid imaging for diagnosis, treatment planning, evaluation of treatment efficacy and toxicity in advanced NSCLC, also taking into consideration its limitations and future directions. CONCLUSIONS: The advent of ICIs marks the dawn of a new era bringing forth new challenges particularly vis-à-vis treatment response assessment and observation of novel phenomena accompanied by novel systemic side effects. While FDG PET/CT is widely adopted for tumor volume delineation in locally advanced disease, response assessment to immunotherapy based on current criteria is of high clinical value but has its inherent limitations. In recent years, modifications of established (PET)/CT criteria have been proposed to provide more refined approaches towards response evaluation. Not only a comprehensive inclusion of PET-based response criteria in prospective randomized controlled trials, but also a general harmonization within the variety of PET-based response criteria is pertinent to strengthen clinical implementation and widespread use of hybrid imaging for response assessment in NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/terapia , Terapia Combinada , Fluorodesoxiglucosa F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Estudios Prospectivos
4.
Eur Radiol ; 29(12): 6443-6446, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31278582

RESUMEN

KEY POINTS: • Molecular intervertebral disc damage was associated with LBP and radiculopathy.• Patients with radiculopathy and LBP demonstrated a depletion of gagCEST values compared with healthy controls.• GagCEST imaging may be a non-invasive tool for investigation of degeneration processes of lumbar intervertebral discs (IVDs). GagCEST imaging may be an imaging biomarker for biochemical IVD alterations.


Asunto(s)
Degeneración del Disco Intervertebral/diagnóstico por imagen , Disco Intervertebral/diagnóstico por imagen , Dolor de la Región Lumbar/fisiopatología , Imagen por Resonancia Magnética/métodos , Radiculopatía/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/análisis , Femenino , Glicosaminoglicanos/metabolismo , Humanos , Disco Intervertebral/metabolismo , Degeneración del Disco Intervertebral/complicaciones , Degeneración del Disco Intervertebral/metabolismo , Dolor de la Región Lumbar/etiología , Dolor de la Región Lumbar/metabolismo , Vértebras Lumbares/metabolismo , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiculopatía/etiología , Radiculopatía/metabolismo , Adulto Joven
5.
Acta Radiol ; 58(1): 70-76, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26936899

RESUMEN

BACKGROUND: Artifacts from metallic implants can hinder image interpretation in computed tomography (CT). Image quality can be improved using metal artifact reduction (MAR) techniques. PURPOSE: To evaluate the impact of a MAR algorithm on image quality of CT examinations in comparison to filtered back projection (FBP) in patients with hip prostheses. MATERIAL AND METHODS: Twenty-two patients with 25 hip prostheses who underwent clinical abdominopelvic CT on a 64-row CT were included in this retrospective study. Axial images were reconstructed with FBP and five increasing MAR levels (M30-34). Objective artifact strength (OAS) (SIart-SInorm) was assessed by region of interest (ROI) measurements in position of the strongest artifact (SIart) and in an osseous structure without artifact (SInorm) (in Hounsfield units [HU]). Two independent readers evaluated subjective image quality regarding metallic hardware, delineation of bone, adjacent muscle, and pelvic organs on a 5-point scale (1, non-diagnostic; 5, excellent image quality). Artifacts in the near field, far field, and newly induced artifacts due to the MAR technique were analyzed. RESULTS: OAS values were: M34: 243.8 ± 155.4 HU; M33: 294.3 ± 197.8 HU; M32: 340.5 ± 210.1 HU; M31: 393.6 ± 225.2 HU; M30: 446.8 ± 224.2 HU and FBP: 528.9 ± 227.7 HU. OAS values were significantly lower for M32-34 compared to FBP (P < 0.01). For overall subjective image quality, results were: FBP, 2.0 ± 0.2; M30, 2.3 ± 0.8; M31, 2.6 ± 0.5; M32, 3.0 ± 0.6; M33, 3.5 ± 0.6; and M34, 3.8 ± 0.4 (P < 0.001 for M30-M34 vs. FBP, respectively). Increasing MAR levels resulted in new artifacts in 17% of reconstructions. CONCLUSION: The investigated MAR algorithm led to a significant reduction of artifacts from metallic hip implants. The highest MAR level provided the least severe artifacts and the best overall image quality.


Asunto(s)
Artefactos , Articulación de la Cadera/diagnóstico por imagen , Prótesis de Cadera , Modelos Biológicos , Intensificación de Imagen Radiográfica/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Algoritmos , Simulación por Computador , Femenino , Articulación de la Cadera/cirugía , Humanos , Masculino , Metales , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
6.
Radiat Prot Dosimetry ; 197(3-4): 146-153, 2021 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-34952539

RESUMEN

To compare radiation dose and image quality of three CT-scanners using optimal dose protocols in patients with suspected urolithiasis regarding additional hardware (tin filter) and software (iterative reconstruction). Examinations from a single-source CT-scanner (A2) and a dual-source CT-scanner (DSCT) (A1) were compared to a tin filter DSCT (B) regarding dose-length product (DLP) and volume-weighted CT dose-index (CTDIvol). DLP of B was 51 and 53% lower in comparison to A1 and A2 (78.62, 159.20 and 165.80 mGy·cm, respectively; P < 0.0001). CTDIvol of B was 53% and 56% significantly lower compared to A1 and A2, respectively (1.52 vs. 3.22 vs. 3.46 mGy; P < 0.0001). Image quality in B proved to be similar to A1 and A2 (3.57, 3.51 and 3.60, respectively; P > 0.05). Inter-rater agreement regarding image quality was good for all CT-scanners (κ = 0.62). Modern CTs with a built-in tin filter allow a significant reduction of radiation exposure in patients with suspected urolithiasis by optimizing the X-ray spectrum.


Asunto(s)
Estaño , Urolitiasis , Humanos , Dosis de Radiación , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X , Urolitiasis/diagnóstico por imagen
7.
Br J Radiol ; 94(1117): 20200677, 2021 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-33095654

RESUMEN

OBJECTIVES: Modern reconstruction and post-processing software aims at reducing image noise in CT images, potentially allowing for a reduction of the employed radiation exposure. This study aimed at assessing the influence of a novel deep-learning based software on the subjective and objective image quality compared to two traditional methods [filtered back-projection (FBP), iterative reconstruction (IR)]. METHODS: In this institutional review board-approved retrospective study, abdominal low-dose CT images of 27 patients (mean age 38 ± 12 years, volumetric CT dose index 2.9 ± 1.8 mGy) were reconstructed with IR, FBP and, furthermore, post-processed using a novel software. For the three reconstructions, qualitative and quantitative image quality was evaluated by means of CT numbers, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in six different ROIs. Additionally, the reconstructions were compared using SNR, peak SNR, root mean square error and mean absolute error to assess structural differences. RESULTS: On average, CT numbers varied within 1 Hounsfield unit (HU) for the three assessed methods in the assessed ROIs. In soft tissue, image noise was up to 42% lower compared to FBP and up to 27% lower to IR when applying the novel software. Consequently, SNR and CNR were highest with the novel software. For both IR and the novel software, subjective image quality was equal but higher than the image quality of FBP-images. CONCLUSION: The assessed software reduces image noise while maintaining image information, even in comparison to IR, allowing for a potential dose reduction of approximately 20% in abdominal CT imaging. ADVANCES IN KNOWLEDGE: The assessed software reduces image noise by up to 27% compared to IR and 48% compared to FBP while maintaining the image information.The reduced image noise allows for a potential dose reduction of approximately 20% in abdominal imaging.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Dosis de Radiación , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen , Adulto , Aprendizaje Profundo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
8.
J Nucl Med ; 2021 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-34016726

RESUMEN

Purpose: To compare breast magnetic resonance imaging (MRI), thoracal MRI, thoracal 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET)/MRI and axillary sonography for the detection of axillary lymph node metastases in women with newly diagnosed breast cancer. Materials and Methods: This prospective double-center study included patients with newly diagnosed breast cancer between March 2018 and December 2019. Patients underwent thoracal (18F-FDG PET/)MRI, axillary sonography, and dedicated prone breast MRI. Datasets were evaluated separately regarding nodal status (nodal+ vs. nodal-). Histopathology served as reference standard in all patients. The diagnostic performance of breast MRI, thoracal MRI, thoracal PET/MRI and axillary sonography in detecting nodal positive patients was tested by creating receiver-operating-characteristic curves (ROC) with a calculated area under the curve (AUC). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated for all four modalities. A McNemar test was used to assess differences. Results: 112 female patients (mean age 53.04 ± 12.6 years) were evaluated. Thoracal PET/MRI showed the highest ROC-AUC with a value of 0.892. The AUC for breast MRI, thoracal MRI and sonography were 0.782, 0.814 and 0.834, respectively. Differences between thoracal PET/MRI and axillary sonography, thoracal MRI and breast MRI were statistically significant (PET/MRI vs. axillary sonography, P = 0.01; PET/MRI vs. thoracal MRI, P = 0.02; PET/MRI vs. breast MRI, P = 0.03). PET/MRI showed the highest sensitivity (81.8%, 36/44) (95%-CI: 67.29-91.81%) while axillary sonography had the highest specificity (98.5%, 65/66), 95%-CI: 91.84-99.96%). Conclusion: 18F-FDG PET/MRI outperforms axillary sonography, breast MRI and thoracal MRI in determining the axillary lymph node status. In a clinical setting, the combination of 18F-FDG PET/MRI and axillary sonography might be considered to provide even more accuracy in diagnosis.

9.
Br J Radiol ; 93(1112): 20200167, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32579403

RESUMEN

OBJECTIVE: To compare the diagnostic performance of fecal biomarkers and 18F-fludeoxyglucose (18F-FDG) positron emmision tomography-MR (PET-MR) in the assessment of disease activity in patients with ulcerative colitis. METHODS: This study was conducted under the framework of a single-center clinical trial (clinicaltrials.gov [NCT03781284]). N = 50 participants were enrolled. Fecal samples were collected before bowel preparation. All patients underwent whole-body 18F-FDG PET-MR followed by ileocolonoscopy within 24 h. Diagnostic performance of five fecal biomarkers (calprotectin, lactoferrin, polymorphonuclear leukocyte elastase, S100A12 and eosinophil-derived neurotoxin), MR morphological parameters (MRmorph), diffusion-weighted imaging and PET in detecting active disease determined by Rachmilewitz endoscopic activity index (EAI) were evaluated and compared with each other. Correlations between fecal biomarkers, PET and endoscopy were calculated. RESULTS: According to EAI, n = 38 patients presented with endoscopically active disease (16 mild, 19 moderate and 3 severe). All five biomarkers, PET and MRmorph could differentiate endoscopically active disease from endoscopic remission without significant difference regarding their operating characteristics (accuracies between 0.673 for calprotectin and 0.898 for lactoferrin). In predicting endoscopically moderate to severe disease, PET showed the highest diagnostic performance (accuracy = 0.857) compared to calprotectin and lactoferrin (accuracy = 0.633 and 0.735). PET had also the strongest correlation with endoscopy (ρ = 0.685, p < 0.001), while within fecal biomarkers the levels of lactoferrin and eosinophil-derived neurotoxin correlated significantly with EAI (ρ = 0.423 and 0.528, both p < 0.05). CONCLUSION: Both fecal biomarkers and PET-MR were excellent non-invasive diagnostic tools in the assessment of disease activity in ulcerative colitis. ADVANCES IN KNOWLEDGE: Both fecal biomarkers and PET-MR parameters are able to predict endoscopically active disease with comparable diagnostic performance. PET had the highest correlation with endoscopy and outperformed fecal biomarkers in differentiating moderate to severe from mild disease.


Asunto(s)
Colitis Ulcerosa/diagnóstico , Heces/química , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Biomarcadores/análisis , Colitis Ulcerosa/diagnóstico por imagen , Colonoscopía , Neurotoxina Derivada del Eosinófilo/análisis , Femenino , Fluorodesoxiglucosa F18 , Humanos , Lactoferrina/análisis , Elastasa de Leucocito/análisis , Complejo de Antígeno L1 de Leucocito/análisis , Persona de Mediana Edad , Imagen Multimodal/métodos , Proteína S100A12/análisis , Adulto Joven
10.
Br J Radiol ; 93(1112): 20200204, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32525696

RESUMEN

OBJECTIVES: Evaluation of performance and forensic relevance of a novel, photorealistic, 3D reconstruction method (cinematic rendering, (CR)) in comparison with conventional post-mortem CT (PMCT) and volume rendering (VR) technique for visualization of traumatic injuries. METHODS: 112 pathologies (fractures, soft tissue injuries and foreign bodies) from 33 human cadavers undergoing whole body PMCT after traumatic death were retrospectively analyzed. Pathologies were reconstructed with CR and VR techniques. Fractures were classified according to their dislocation. Images were evaluated according to their expressiveness and judicial relevance by two forensic pathologists using a five-level Likert-scale (1: high expressiveness, 5: low expressiveness). They decided whether CR reconstructions were suitable for judicial reviews. The detection rate of pathologies was determined by two radiologists. RESULTS: CR was more expressive than VR for all three trauma categories (p < 0.01) and than conventional CT when used for fractures with dislocation (p < 0.001), injuries of the ventral body surface (p < 0.001), and demonstration of foreign bodies (p = 0.033). CR and VR became more expressive with a higher grade of fracture dislocation (p < 0.001). 20% of all pathologies in the CR and VR reconstructions were not detectable by radiologists. CONCLUSION: CR reconstructions are superior to VR regarding the expressiveness. For fractures with substantial dislocation, soft tissue injuries, and foreign bodies in situ, CR showed a significantly better expressiveness than conventional PMCT. CR and VR have significant limitations in cases of fractures with minor dislocations and covered soft tissue injuries. ADVANCES IN KNOWLEDGE: CR is a helpful tool to present pathologies found in PMCT for judicial reviews.


Asunto(s)
Diagnóstico , Patologia Forense/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Tomografía Computarizada por Rayos X/métodos , Heridas y Lesiones/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad
11.
Nucl Med Mol Imaging ; 54(4): 183-191, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32831964

RESUMEN

PURPOSE: To study the value of 2-deoxy-2-[18F]fluoro-D-glucose([18F]FDG) positron emission tomography/computed tomography (PET/CT) and [18F]FDG positron emission tomography/magnetic resonance imaging (PET/MRI) in assessing immunocompromised patients with suspected malignancy or infection. METHODS: [18F]FDG-PET/CT and [18F]FDG-PET/MRI examinations of patients who were immunocompromised after receiving lung, heart, pancreas, kidney, liver, or combined kidney-liver transplants were analyzed in this retrospective study. Patients underwent whole-body hybrid-imaging because of clinical signs of malignancy and/or infection. Findings were assessed by molecular features ([18F]FDG-uptake) and morphological changes. The final diagnosis, which was arrived at after review of clinical, laboratory, and histopathologic analyses and follow-up imaging studies, served as the reference standard. RESULTS: Altogether, (i) 28 contrast-enhanced [18F]FDG-PET/CT scans (CE-PET/CT), (ii) 33 non-contrast [18F]FDG-PET/CT scans (NC-PET/CT), and (iii) 18 [18F]FDG-PET/MRI scans were included. Additionally, 12/62 patients underwent follow-up PET imaging to rule out vital tumor or metabolic active inflammatory processes. CE-PET/CT exhibited 94.4% sensitivity, 80.0% specificity, 89.5% positive predictive value (PPV), 88.9% negative predictive value (NPV), and 89.3% accuracy with regard to the reference standard. NC-PET/CT exhibited 91.3% sensitivity, 80.0% specificity, 91.3% PPV, 80.0% NPV, and 87.9% accuracy. PET/MRI exhibited 88.6% sensitivity, 99.2% specificity, 99.6% PPV, 81.3% NPV, and 94.4% accuracy. Exact McNemar statistical test (one-sided) showed significant difference between the CT-/MR-component alone and the integrated PET/CT and PET/MRI for diagnosis of malignancy or infection (p value < 0.001). Radiation exposure was 4- to 7-fold higher with PET/CT than with PET/MRI. CONCLUSION: For immunocompromised patients with clinically unresolved symptoms, to rule out vital tumor manifestations or metabolic active inflammation, [18F]FDG-PET/MRI, CE-[18F]FDG-PET/CT, and NC-[18F]FDG-PET/CT exhibit excellent performance in diagnosing malignancy or infection. The main strength of PET/MRI is its considerably lower level of radiation exposure than that associated with PET/CT.

12.
Clin Imaging ; 52: 328-333, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30236779

RESUMEN

PURPOSE: To evaluate performance and the clinical impact of a novel machine learning based vessel-suppressing computer-aided detection (CAD) software in chest computed tomography (CT) of patients with malignant melanoma. MATERIALS AND METHODS: We retrospectively included consecutive malignant melanoma patients with a chest CT between 01/2015 and 01/2016. Machine learning based CAD software was used to reconstruct additional vessel-suppressed axial images. Three radiologists independently reviewed a maximum of 15 lung nodules per patient. Vessel-suppressed reconstructions were reviewed independently and results were compared. Follow-up CT examinations and clinical follow-up were used to assess the outcome. Impact of additional nodules on clinical management was assessed. RESULTS: In 46 patients, vessel-suppressed axial images led to the detection of additional nodules in 25/46 (54.3%) patients. CT or clinical follow up was available in 25/25 (100%) patients with additionally detected nodules. 2/25 (8%) of these patients developed new pulmonary metastases. None of the additionally detected nodules were found to be metastases. None of the lung nodules detected by the radiologists was missed by the CAD software. The mean diameter of the 92 additional nodules was 1.5 ±â€¯0.8 mm. The additional nodules did not affect therapeutic management. However, in 14/46 (30.4%) of patients the additional nodules might have had an impact on the radiological follow-up recommendations. CONCLUSION: Machine learning based vessel suppression led to the detection of significantly more lung nodules in melanoma patients. Radiological follow-up recommendations were altered in 30% of the patients. However, all lung nodules turned out to be non-malignant on follow-up.


Asunto(s)
Diagnóstico por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Aprendizaje Automático , Melanoma/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Neoplasias Cutáneas/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Neoplasias Pulmonares/irrigación sanguínea , Neoplasias Pulmonares/secundario , Masculino , Persona de Mediana Edad , Metástasis de la Neoplasia , Curva ROC , Estudios Retrospectivos , Melanoma Cutáneo Maligno
13.
Radiat Prot Dosimetry ; 178(1): 8-19, 2018 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-28541574

RESUMEN

To evaluate the accuracy of size-specific dose estimate (SSDE) calculation from center slice with water-equivalent diameter (Dw) and effective diameter (Deff). A total of 1812 CT exams (1583 adult and 229 pediatric) were included in this retrospective study. Dw and Deff were automatically calculated for all slices of each scan. SSDEs were calculated with two methods: (1) from the center slice; and (2) from all slices of the volume, which was regarded as the reference standard. Impact of patient weight, height and body mass index (BMI) on SSDE accuracy was assessed. The mean difference between overall SSDE and the center slice approach ranged from 2.0 ± 1.7% (range: 0-15.5%) for pediatric chest to 5.0 ± 3.2% (0-17.2%) for adult chest CT. Accuracy of the center slice SSDE approach correlated with patient size (BMI: r = 0.15-0.43; weight r = 0.26-0.49) which led to SSDE overestimation in small and underestimation in large patients. SSDE calculation using the center slice leads to an error of 2-5%; however, SSDE is underestimated in large patients and overestimation in small patients.


Asunto(s)
Tamaño Corporal , Dosis de Radiación , Monitoreo de Radiación/métodos , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Índice de Masa Corporal , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
14.
Br J Radiol ; 90(1079): 20160778, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28830194

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the impact of three novel iterative metal artefact (iMAR) algorithms on image quality and artefact degree in chest CT of patients with a variety of thoracic metallic implants. METHODS: 27 postsurgical patients with thoracic implants who underwent clinical chest CT between March and May 2015 in clinical routine were retrospectively included. Images were retrospectively reconstructed with standard weighted filtered back projection (WFBP) and with three iMAR algorithms (iMAR-Algo1 = Cardiac algorithm, iMAR-Algo2 = Pacemaker algorithm and iMAR-Algo3 = ThoracicCoils algorithm). The subjective and objective image quality was assessed. RESULTS: Averaged over all artefacts, artefact degree was significantly lower for the iMAR-Algo1 (58.9 ± 48.5 HU), iMAR-Algo2 (52.7 ± 46.8 HU) and the iMAR-Algo3 (51.9 ± 46.1 HU) compared with WFBP (91.6 ± 81.6 HU, p < 0.01 for all). All iMAR reconstructed images showed significantly lower artefacts (p < 0.01) compared with the WFPB while there was no significant difference between the iMAR algorithms, respectively. iMAR-Algo2 and iMAR-Algo3 reconstructions decreased mild and moderate artefacts compared with WFBP and iMAR-Algo1 (p < 0.01). CONCLUSION: All three iMAR algorithms led to a significant reduction of metal artefacts and increase in overall image quality compared with WFBP in chest CT of patients with metallic implants in subjective and objective analysis. The iMARAlgo2 and iMARAlgo3 were best for mild artefacts. IMARAlgo1 was superior for severe artefacts. Advances in knowledge: Iterative MAR led to significant artefact reduction and increase image-quality compared with WFBP in CT after implementation of thoracic devices. Adjusting iMAR-algorithms to patients' metallic implants can help to improve image quality in CT.


Asunto(s)
Algoritmos , Artefactos , Metales , Prótesis e Implantes , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Hilos Ortopédicos , Femenino , Corazón Auxiliar , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Periodo Posoperatorio , Radiografía Torácica/normas , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/normas
15.
PLoS One ; 12(2): e0172553, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28225831

RESUMEN

OBJECTIVES: To evaluate the diagnostic feasibility of an ultra-fast 18F-FDG PET/MRI protocol, including T2-w and contrast-enhanced T1-w imaging as well as metabolic assessment (PET) in comparison to 18F-FDG PET/CT and CT for whole-body staging of female patients with suspected recurrence of pelvic malignancies. METHODS: 43 female patients with suspected tumor recurrence were included in this study. Suspicion was based on clinical follow-up and abnormal findings on imaging follow-up. All patients underwent a PET/CT and a subsequent PET/MRI examination. Two readers were asked to evaluate ultra-fast PET/MRI, PET/CT as well as CT datasets of PET/CT separately for suspect lesions regarding lesion count, lesion localization and lesion characterization. Statistical analyses were performed both, on a per-patient and a per-lesion basis. RESULTS: Tumor relapse was present in 38 of the 43 patients. Based on CT readings 25/38 tumor relapses were correctly identified. PET/CT enabled correct identification of 37/38 patients, PET/MRI correctly identified 36 of the 38 patients with recurrent cancer. On a lesion-based analysis PET/MRI enabled the correct detection of more lesions, comprising a lesion-based sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of 50%, 58%, 76%, 31%, and 53% for CT, 97%, 83%, 93%, 94%, and 92% for PET/CT and 98%, 83%, 94%, 94%, and 94% for PET/MRI, respectively. Mean scan duration of ultra-fast PET/MRI, PET/CT and whole-body CT amounted to 18.5 ± 1 minutes, 18.2 ± 1 minutes and 3.5 minutes, respectively. CONCLUSION: Ultra-fast PET/MRI provides equivalent diagnostic performance and examination time when compared to PET/CT and superior diagnostic performance to CT in restaging female patients suspected to have recurrent pelvic cancer.


Asunto(s)
Imagen Multimodal/métodos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Neoplasias Pélvicas/diagnóstico por imagen , Pelvis/diagnóstico por imagen , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Femenino , Fluorodesoxiglucosa F18 , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
16.
Eur J Radiol ; 89: 14-19, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28267530

RESUMEN

OBJECTIVES: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. METHODS: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. RESULTS: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p<0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. CONCLUSION: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the inclusion of DWI in the study protocol seems to be debatable.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética/métodos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Mama/diagnóstico por imagen , Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Imagen Multimodal/métodos , Recurrencia Local de Neoplasia/patología , Estadificación de Neoplasias , Radiofármacos , Reproducibilidad de los Resultados
17.
Clin Nucl Med ; 42(7): e322-e327, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28481787

RESUMEN

PURPOSE: To investigate the physiologic Ga-PSMA distribution and evaluate focal or diffuse radiotracer uptake in nonprostate cancer malignancies and in incidental findings. METHODS: Ga-PSMA PET/CT scans in 55 men performed for prostate cancer (49) or renal cell carcinoma (6) staging were analyzed retrospectively. Two radiologists evaluated the datasets in 2 reading sessions. First, physiological Ga-PSMA uptake was evaluated. Second, scans were analyzed for incidental uptake. SUVmax and SUVmean were recorded. Other imaging modalities, histopathology, or clinical follow-up served as standard of reference. RESULTS: Homogenous Ga-PSMA uptake of the lacrimal glands (SUVmax, 15.7 ± 7.2), parotid glands (SUVmax, 24.4 ± 8.1), submandibular glands (SUVmax, 26.7 ± 7.1), vocal cords (SUVmax, 8.4 ± 3), Waldeyer ring (SUVmax, 10.4 ± 4.3), liver (SUVmax, 8.2 ± 2.5), spleen (SUVmax, 10.9 ± 3.9), kidneys (SUVmax, 66.4 ± 25.4), and pars descendens duodeni (SUVmax, 17.6 ± 8.9) was observed in all patients. In 65% and 36%, respectively, homogenous Ga-PSMA uptake of the colon descendens (SUVmax, 10.6 ± 9.2) and the rectum (SUVmax, 3.7 ± 1.1) was found. Approximately 22% exhibited a Ga-PSMA uptake of the thyroid (SUVmax, 4.5 ± 1.2), and 21% exhibited a Ga-PSMA uptake of the knee's synovia (SUVmax, 2.9 ± 0.2). Furthermore, Ga-PSMA uptake was found in 1 patient because of fibrous dysplasia of the right os ilium (SUVmax, 7.7). CONCLUSIONS: Physiologic distribution of Ga-PSMA comprises uptake in lacrimal and salivary glands, vocal cords, Waldeyer ring, liver, spleen, and kidneys as well as various parts of the intestine. Moreover, nonspecific tracer uptake is regularly found in the thyroid and the synovia of the knee. Incidental Ga-PSMA uptake can occasionally reveal nonprostate cancer-associated remodeling processes, such as fibrous dysplasia.


Asunto(s)
Ácido Edético/análogos & derivados , Interpretación de Imagen Asistida por Computador , Oligopéptidos/metabolismo , Tomografía Computarizada por Tomografía de Emisión de Positrones , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/metabolismo , Anciano , Anciano de 80 o más Años , Transporte Biológico , Ácido Edético/metabolismo , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Persona de Mediana Edad , Trazadores Radiactivos , Estudios Retrospectivos
18.
Diagn Interv Radiol ; 23(2): 127-132, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28089955

RESUMEN

PURPOSE: We aimed to investigate the accuracy of 18F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI) compared with contrast-enhanced 18F-FDG PET/computed tomography (PET/CT) for the characterization of incidental tracer uptake in examinations of the head and neck. METHODS: A retrospective analysis of 81 oncologic patients who underwent contrast-enhanced 18F-FDG PET/CT and subsequent PET/MRI was performed by two readers for incidental tracer uptake. In a consensus reading, discrepancies were resolved. Each finding was either characterized as most likely benign, most likely malignant, or indeterminate. Using all available clinical information including results from histopathologic sampling and follow-up examinations, an expert reader classified each finding as benign or malignant. McNemar's test was used to compare the performance of both imaging modalities in characterizing incidental tracer uptake. RESULTS: Forty-six lesions were detected by both modalities. On PET/CT, 27 lesions were classified as most likely benign, one as most likely malignant, and 18 as indeterminate; on PET/MRI, 31 lesions were classified as most likely benign, one lesion as most likely malignant, and 14 as indeterminate. Forty-three lesions were benign and one lesion was malignant according to the reference standard. In two lesions, a definite diagnosis was not possible. McNemar's test detected no differences concerning the correct classification of incidental tracer uptake between PET/CT and PET/MRI (P = 0.125). CONCLUSION: In examinations of the head and neck area, incidental tracer uptake cannot be classified more accurately by PET/MRI than by PET/CT.


Asunto(s)
Fluorodesoxiglucosa F18/metabolismo , Cabeza/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Cuello/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos/metabolismo , Adulto , Anciano , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Estudios Retrospectivos , Sensibilidad y Especificidad
19.
PLoS One ; 11(6): e0157880, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27327617

RESUMEN

BACKGROUND: The aim of this study was to assess the applicability of a fast MR-protocol for whole-body staging of lymphoma patients using an integrated PET/MR system. METHODS: A total of 48 consecutive lymphoma patients underwent 52 clinically indicated PET/CT and subsequent PET/MRI examinations with the use of 18F-FDG. For PET/MR imaging, a fast whole-body MR-protocol was implemented. A radiologist and a nuclear medicine physician interpreted MRI and PET/MRI datasets in consensus and were instructed to identify manifestations of lymphoma on a site-specific analysis. The accuracy for the identification of active lymphoma disease was calculated and the tumor stage for each examination was determined. Furthermore, radiation doses derived from administered tracer activities and CT protocol parameters were estimated and the mean scan duration of PET/CT and PET/MR imaging was determined. Statistical analysis was performed to compare the diagnostic performance of PET/MRI and MRI alone. The results of PET/CT imaging, all available histopathological samples as well as results of prior examinations and follow-up imaging were used for the determination of the reference standard. RESULTS: Active lymphoma disease was present in 28/52 examinations. PET/MRI revealed higher values of diagnostic accuracy for the identification of active lymphoma disease in those 52 examinations in comparison to MRI, however, results of the two ratings did not differ significantly. On a site specific analysis, PET/MRI showed a significantly higher accuracy for the identification of nodal manifestation of lymphoma (p<0.05) if compared to MRI, whereas ratings for extranodal regions did not reveal a significant difference. In addition, PET/MRI enabled correct identification of lymphoma stage in a higher percentage of patients than MRI (94% vs. 83%). Furthermore, SUVs derived from PET/MRI were significantly higher than in PET/CT, however, there was a strong positive correlation between SUVmax and SUVmean of the two imaging modalities (R = 0.91 p<0.001 and R = 0.87, p<0.001). Average scan duration of whole-body PET/CT and PET/MRI examinations amounted to 17.3±1.9 min and 27.8±3.7 min, respectively. Estimated mean effective-dose for whole-body PET/CT scans were 64.4% higher than for PET/MRI. CONCLUSIONS: Our results demonstrate the usefulness of 18F-FDG PET data as a valuable additive to MRI for a more accurate evaluation of patients with lymphomas. With regard to patient comfort related to scan duration and a markedly reduced radiation exposure, fast PET/MRI may serve as a powerful alternative to PET/CT for a diagnostic workup of lymphoma patients.


Asunto(s)
Linfoma/diagnóstico por imagen , Linfoma/diagnóstico , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Humanos , Pelvis Renal/diagnóstico por imagen , Pelvis Renal/patología , Ganglios Linfáticos/patología , Linfoma/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía Computarizada por Tomografía de Emisión de Positrones , Adulto Joven
20.
PLoS One ; 11(12): e0167596, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27907162

RESUMEN

INTRODUCTION: The objective of this study was to assess the diagnostic value of integrated 11C- methionine PET/MRI for suspected primary brain tumors, in comparison to MRI alone. MATERIAL AND METHODS: Forty-eight consecutive patients with suspected primary brain tumor were prospectively enrolled for an integrated 11C-methionine PET/MRI. Two neuro-radiologists separately evaluated the MRI alone and the integrated PET/MRI data sets regarding most likely diagnosis and diagnostic confidence on a 5-point scale. Reference standard was histopathology or follow-up imaging. RESULTS: Fifty-one suspicious lesions were detected: 16 high-grade glioma and 25 low-grade glioma. Ten non-malignant cerebral lesions were described by the reference standard. MRI alone and integrated PET/MRI each correctly classified 42 of the 51 lesions (82.4%) as neoplastic lesions (WHO grade II, III and IV) or non-malignant lesions (infectious and neoplastic lesions). Diagnostic confidence for all lesions, low-grade astrocytoma and high-grade astrocytoma (3.7 vs. 4.2, 3,1 vs. 3.8, 4.0 vs. 4,7) were significantly (p < 0.05) better with integrated PET/MRI than in MRI alone. CONCLUSIONS: The present study demonstrates the high potential of integrated 11C-methionine-PET/MRI for the assessment of suspected primary brain tumors. Although integrated methionine PET/MRI does not lead to an improvement of correct diagnoses, diagnostic confidence is significantly improved.


Asunto(s)
Neoplasias Encefálicas/diagnóstico , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Adulto , Anciano , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/patología , Medios de Contraste/administración & dosificación , Femenino , Humanos , Masculino , Metionina/administración & dosificación , Persona de Mediana Edad , Imagen Multimodal , Radioisótopos/administración & dosificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA