Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 51(3): 841-851, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37947848

RESUMEN

BACKGROUND: Historically, patient selection for peptide receptor radionuclide therapy (PRRT) has been performed by virtue of somatostatin receptor scintigraphy (SRS). In recent years, somatostatin receptor positron emission tomography (SSTR-PET) has gradually replaced SRS because of its improved diagnostic capacity, creating an unmet need for SSTR-PET-based selection criteria for PRRT. Tumor-to-blood ratio (TBR) measurements have shown high correlation with the net influx rate Ki, reflecting the tumor somatostatin receptor expression, to a higher degree than standardized uptake value (SUV) measurements. TBR may therefore predict treatment response to PRRT. In addition, changes in semiquantitative SSTR-PET parameters have been shown to predate morphological changes, making them a suitable metric for response assessment. METHODS: The institutional database of the Department of Nuclear Medicine (University Hospital Essen) was searched for NET patients undergoing ≥ 2 PRRT cycles with available baseline and follow-up SSTR-PET. Two blinded independent readers reported the occurrence of new lesions quantified tumor uptake of up to nine lesions per patient using SUV and TBR. The association between baseline TBR and changes in uptake/occurrence of new lesions with progression-free survival (PFS) and overall survival (OS) was tested by use of a Cox regression model and log-rank test. RESULTS: Patients with baseline TBR in the 1st quartile had a shorter PFS (14.4 months) than those in the 3rd (23.7 months; p = 0.03) and 4th (24.1 months; p = 0.02) quartile. Similarly, these patients had significantly shorter OS (32.5 months) than those with baseline TBR in the 2nd (41.8 months; p = 0.03), 3rd (69.2 months; p < 0.01), and 4th (42.7 months; p = 0.03) quartile. Baseline to follow-up increases in TBR were independently associated with shorter PFS when accounting for prognostic markers, e.g., RECIST response (hazard ratio = 2.91 [95%CI = 1.54-5.50]; p = 0.01). This was confirmed with regard to OS (hazard ratio = 1.64 [95%CI = 1.03-2.62]; p = 0.04). Changes in SUVmean were not associated with PFS or OS. CONCLUSIONS: Baseline TBR as well as changes in TBR were significantly associated with PFS and OS and may improve patient selection and morphological response assessment. Future trials need to assess the role of TBR for therapy monitoring also during PRRT and prospectively explore TBR as a predictive marker for patient selection.


Asunto(s)
Tumores Neuroendocrinos , Compuestos Organometálicos , Humanos , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/metabolismo , Receptores de Somatostatina/metabolismo , Pronóstico , Supervivencia sin Progresión , Resultado del Tratamiento , Octreótido , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos
2.
Eur Radiol ; 2023 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-37935847

RESUMEN

OBJECTIVES: Percutaneous image-guided tumor ablation of liver malignancies has become an indispensable therapeutic procedure. The aim of this evaluation of the prospectively managed multinational registry of the voluntary German Society for Interventional Radiology and Minimally Invasive Therapy (DeGIR) was to analyze its use, technical success, and complications in clinical practice. MATERIALS AND METHODS: All liver tumor ablations from 2018 to 2022 were included. Technical success was defined as complete ablation of the tumor with an ablative margin. RESULTS: A total of 7228 liver tumor ablations from 136 centers in Germany and Austria were analyzed. In total, 31.4% (2268/7228) of patients were female. Median age was 67 years (IQR 58-74 years). Microwave ablation (MWA) was performed in 65.1% (4703/7228), and radiofrequency ablation (RFA) in 32.7% (2361/7228). Of 5229 cases with reported tumor etiology, 60.3% (3152/5229) of ablations were performed for liver metastases and 37.3% (1950/5229) for hepatocellular carcinoma. The median lesion diameter was 19 mm (IQR 12-27 mm). In total, 91.8% (6636/7228) of ablations were technically successful. The rate of technically successful ablations was significantly higher in MWA (93.9%, 4417/4703) than in RFA (87.3%, 2061/2361) (p < 0.0001). The total complication rate was 3.0% (214/7228) and was significantly higher in MWA (4.0%, 189/4703) than in RFA (0.9%, 21/2361, p < 0.0001). Additional needle track ablation did not increase the rate of major complications significantly (24.8% (33/133) vs. 28.4% (23/81), p = 0.56)). CONCLUSION: MWA is the most frequent ablation method. Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for MWA than RFA. The complication rate is generally low but is higher for MWA than RFA. CLINICAL RELEVANCE STATEMENT: Percutaneous image-guided liver ablation using microwave ablation and radiofrequency ablation are effective therapeutic procedures with low complication rates for the treatment of primary and secondary liver malignancies. KEY POINTS: • Percutaneous image-guided liver tumor ablations have a high technical success rate, which is higher for microwave ablation than radiofrequency ablation. • Microwave ablation is the most frequent ablation method ahead of radiofrequency ablation. • The complication rate is generally low but is higher for microwave ablation than radiofrequency ablation.

3.
J Radiol Prot ; 42(3)2022 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-36067741

RESUMEN

90Y radioembolisation (RE) is an angiographic procedure used in patients with both primary and secondary hepatic malignancies. Local tumour control can be achieved by short range tumour irradiation by the regional intra-arterial administration of glass or resin microspheres loaded with 90yttrium that accumulate in the tumorous tissue. The aim of this study was to investigate the radiation exposure of RE and to establish a local diagnostic reference level (DRL). In this retrospective study, dose data from 397 procedures in 306 patients (mean age 67.4 ± 10.6 years, 82 female) who underwent RE between 06/2017 and 01/2022 using one of two different angiography systems were analysed. DRL was set as the 75th percentile of the dose distribution. In the overall population, dose area product (DAP) (median (interquartile range, IQR)) was 26 Gy cm2(IQR 12-50) with a median fluoroscopy time (FT) of 4.5 min (IQR 2.9-8.0). FT and DAP increased significantly with the number of infusion positions (median, IQR): one position 23 Gy cm2(12-46), two positions 33 Gy cm2(14-60), three positions 50 Gy cm2(24-82) (p< 0.0001). Local DRL is 47 Gy cm2for RE and 111 Gy cm2for RE with additional embolisation. Radiation exposure and FT are significantly higher with increasing number of infusion positions as well as additional embolisation. Our established DRLs for RE may serve as a benchmark for dose optimisation.


Asunto(s)
Angiografía , Niveles de Referencia para Diagnóstico , Anciano , Femenino , Fluoroscopía , Humanos , Persona de Mediana Edad , Dosis de Radiación , Estudios Retrospectivos
4.
J Radiol Prot ; 42(3)2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35790148

RESUMEN

Computed tomography (CT)-guided percutaneous biopsies play an important role in the diagnostic workup of liver lesions. Because radiation dose accumulates rapidly due to repeated image acquisition in a relatively small scan area, analysing radiation exposure is critical for improving radiation protection of CT-guided interventions. The aim of this study was to assess the radiation dose of CT-guided liver biopsies and the influence of lesion parameters, and to establish a local diagnostic reference level (DRL). In this observational retrospective cohort study, dose data of 60 CT-guided liver biopsies between September 2016 and July 2017 were analysed. Radiation exposure was reported for volume-weighted CT dose index (CTDIvol), size-specific dose estimate (SSDE), dose-length product (DLP) and effective dose (ED). Radiation dose of CT-guided liver biopsy was (median (interquartile range)): CTDIvol9.91 mGy (8.33-11.45 mGy), SSDE 10.42 mGy (9.39-11.70 mGy), DLP 542 mGy cm (410-733 mGy cm), ED 8.52 mSv (7.17-13.25 mSv). Radiation exposure was significantly higher in biopsies of deep liver lesions compared to superficial lesions (DLP 679 ± 285 mGy cm vs. 497 ± 167 mGy cm,p= 0.0046). No significant dose differences were observed for differences in lesion or needle size. With helical CT spirals additional to the biopsy-guiding axial CT scans, radiation exposure was significantly increased: 797 ± 287 mGy cm vs. 495 ± 162 mGy cm,p< 0.0001. The local DRL is CTDIvol9.91 mGy, DLP 542 mGy cm. Radiation dose is significantly increased in biopsies of deeper liver lesions compared with superficial lesions. Interventions with additional biopsy-guiding CT spirals lead to higher radiation doses. This study provides a detailed analysis of local radiation doses for CT-guided liver biopsies and provides a benchmark for optimising radiation protection in interventional radiology.


Asunto(s)
Neoplasias Hepáticas , Exposición a la Radiación , Humanos , Biopsia Guiada por Imagen , Dosis de Radiación , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
5.
BMC Infect Dis ; 21(1): 969, 2021 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-34535095

RESUMEN

BACKGROUND: The ongoing COVID-19 pandemic remains a major challenge for worldwide health care systems and in particular emergency medicine. An early and safe triage in the emergency department (ED) is especially crucial for proper therapy. Clinical symptoms of COVID-19 comprise those of many common diseases; thus, differential diagnosis remains challenging. METHOD: We performed a retrospective study of 314 ED patients presenting with conceivable COVID-19 symptoms during the first wave in Germany. All were tested for COVID-19 with SARS-Cov-2-nasopharyngeal swabs. Forty-seven patients were positive. We analyzed the 267 COVID-19 negative patients for their main diagnosis and compared COVID-19 patients with COVID-19 negative respiratory infections for differences in laboratory parameters, symptoms, and vital signs. RESULTS: Among the 267 COVID-19 negative patients, 42.7% had respiratory, 14.2% had other infectious, and 11.2% had cardiovascular diseases. Further, 9.0% and 6.7% had oncological and gastroenterological diagnoses, respectively. Compared to COVID-19 negative airway infections, COVID-19 patients showed less dyspnea (OR 0.440; p = 0.024) but more dysgeusia (OR 7.631; p = 0.005). Their hospital stay was significantly longer (9.0 vs. 5.6 days; p = 0.014), and their mortality significantly higher (OR 3.979; p = 0.014). CONCLUSION: For many common ED diagnoses, COVID-19 should be considered a differential diagnosis. COVID-19 cannot be distinguished from COVID-19 negative respiratory infections by clinical signs, symptoms, or laboratory results. When hospitalization is necessary, the clinical course of COVID-19 airway infections seems to be more severe compared to other respiratory infections. TRIAL REGISTRATION: German Clinical Trial Registry DRKS, DRKS-ID of the study: DRKS00021675 date of registration: May 8th, 2020, retrospectively registered.


Asunto(s)
COVID-19 , Diagnóstico Diferencial , Servicio de Urgencia en Hospital , Humanos , Pandemias , Estudios Retrospectivos , SARS-CoV-2
6.
Eur J Nucl Med Mol Imaging ; 47(4): 768-777, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31650217

RESUMEN

PURPOSE: To evaluate the diagnostic performance of PET-MR enterography in detecting histological active inflammation in patients with ulcerative colitis and the impact of bowel purgation on diagnostic accuracies of PET-MR parameters. METHODS: Fifty patients were enrolled in this randomized controlled trial (clinicaltrials.gov [NCT03781284]). Forty patients were randomized in two study arms, in which bowel purgation was performed either before or after PET-MR enterography. All patients underwent ileocolonoscopy with mucosal biopsies after PET-MR within 24 h. Diagnostic performance of MR morphological parameters (MRmorph), diffusion-weighted imaging (DWI), and PET in detecting histological inflammation determined by the Nancy index was compared with each other and between study arms. Correlation between PET and histological inflammatory severity was calculated. RESULTS: In study arm without previous bowel purgation, SUVmax ratio of bowel segment (relative to SUVmax of the liver) facilitated the highest specificity and diagnostic accuracy compared with MRmorph and DWI. Bowel cleansing led to markedly increased metabolic activity of bowel segments, resulting in significantly reduced specificity of PET compared with study arm without purgation (0.808 vs. 0.966, p = 0.007, respectively). Inter-observer concordance for assessing MRmorph was clearly increased after bowel cleansing (Cohen's κ, 0.847 vs. 0.665; p = 0.013, respectively), though diagnostic performance of MRmorph was not significantly improved. Our findings suggested that the change of metabolic status was mainly associated with the grade of neutrophil infiltrate and less dependent on chronic infiltrate. CONCLUSION: PET-MR enterography was an excellent non-invasive diagnostic method in the assessment of histological active inflammation in ulcerative colitis without the need of previous bowel purgation. TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03781284.


Asunto(s)
Colitis Ulcerosa , Fluorodesoxiglucosa F18 , Colitis Ulcerosa/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética , Humanos , Inflamación , Imagen por Resonancia Magnética
7.
Eur J Nucl Med Mol Imaging ; 47(4): 778-786, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31701188

RESUMEN

OBJECTIVES: To evaluate the impact of morphological information derived from contrast-enhanced CT in the characterization of incidental focal colonic uptake in 18F-FDG PET/CT examinations. METHODS: A total of 125 patients (female: n = 53, male: n = 72) that underwent colonoscopy secondary to contrast-enhanced, full-dose PET/CT without special bowel preparation were included in this retrospective study. PET/CT examinations were assessed for focal colonic tracer uptake in comparison with the background. Focal tracer uptake was correlated with morphological changes of the colonic wall in the contrast-enhanced CT images. Colonoscopy reports were evaluated for benign, inflammatory, polypoid, precancerous, and cancerous lesions verified by histopathology, serving as a reference standard. Sensitivity, specificity, PPV, NPV, and accuracy for detection of therapeutic relevant findings were calculated for (a) sole focal tracer uptake and (b) focal tracer uptake with correlating CT findings in contrast-enhanced CT. RESULTS: In 38.4% (48/125) of the patients, a focal 18F-FDG uptake was observed within 67 lesions. Malignant lesions were endoscopically and histopathologically diagnosed in eleven patients, and nine of these were detected by focal 18F-FDG uptake. A total of 34 lesions with impact on short- or long-term patient management (either being pre- or malignant) were detected. Sensitivity, Specificity, PPV, NPV, and accuracy for sole 18F-FDG uptake for this combined group were 54%, 69%, 29%, 85%, and 65%. Corresponding results for focal 18F-FDG uptake with correlating CT findings were 38%, 90%, 50%, 86%, and 80%. This resulted in a statistically significant difference for diagnostic accuracy (p = 0.0001) CONCLUSION: By analyzing additional morphological changes in contrast-enhanced CT imaging, the specificity of focal colonic 18F-FDG uptake for precancerous and cancerous lesions can be increased but leads to a considerate loss of sensitivity. Therefore, every focal colonic uptake should be followed up by colonoscopy.


Asunto(s)
Fluorodesoxiglucosa F18 , Tomografía Computarizada por Tomografía de Emisión de Positrones , Colon/diagnóstico por imagen , Colonoscopía , Femenino , Humanos , Hallazgos Incidentales , Masculino , Tomografía de Emisión de Positrones , Radiofármacos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
8.
Eur J Nucl Med Mol Imaging ; 47(12): 2816-2825, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32333068

RESUMEN

OBJECTIVES: To evaluate and compare the diagnostic potential of whole-body MRI and whole-body 18F-FDG PET/MRI for N and M staging in newly diagnosed, histopathologically proven breast cancer. MATERIAL AND METHODS: A total of 104 patients (age 53.4 ± 12.5) with newly diagnosed, histopathologically proven breast cancer were enrolled in this study prospectively. All patients underwent a whole-body 18F-FDG PET/MRI. MRI and 18F-FDG PET/MRI datasets were evaluated separately regarding lesion count, lesion localization, and lesion characterization (malignant/benign) as well as the diagnostic confidence (5-point ordinal scale, 1-5). The N and M stages were assessed according to the eighth edition of the American Joint Committee on Cancer staging manual in MRI datasets alone and in 18F-FDG PET/MRI datasets, respectively. In the majority of lesions histopathology served as the reference standard. The remaining lesions were followed-up by imaging and clinical examination. Separately for nodal-positive and nodal-negative women, a McNemar chi2 test was performed to compare sensitivity and specificity of the N and M stages between 18F-FDG PET/MRI and MRI. Differences in diagnostic confidence scores were assessed by Wilcoxon signed rank test. RESULTS: MRI determined the N stage correctly in 78 of 104 (75%) patients with a sensitivity of 62.3% (95% CI: 0.48-0.75), a specificity of 88.2% (95% CI: 0.76-0.96), a PPV (positive predictive value) of 84.6% % (95% CI: 69.5-0.94), and a NPV (negative predictive value) of 69.2% (95% CI: 0.57-0.8). Corresponding results for 18F-FDG PET/MRI were 87/104 (83.7%), 75.5% (95% CI: 0.62-0.86), 92.2% (0.81-0.98), 90% (0.78-0.97), and 78.3% (0.66-0.88), showing a significantly better sensitivity of 18F-FDG PET/MRI determining malignant lymph nodes (p = 0.008). The M stage was identified correctly in MRI and 18F-FDG PET/MRI in 100 of 104 patients (96.2%). Both modalities correctly staged all 7 patients with distant metastases, leading to false-positive findings in 4 patients in each modality (3.8%). In a lesion-based analysis, 18F-FDG PET/MRI showed a significantly better performance in correctly determining malignant lesions (85.8% vs. 67.1%, difference 18.7% (95% CI: 0.13-0.26), p < 0.0001) and offered a superior diagnostic confidence compared with MRI alone (4.1 ± 0.7 vs. 3.4 ± 0.7, p < 0.0001). CONCLUSION: 18F-FDG PET/MRI has a better diagnostic accuracy for N staging in primary breast cancer patients and provides a significantly higher diagnostic confidence in lesion characterization than MRI alone. But both modalities bear the risk to overestimate the M stage.


Asunto(s)
Neoplasias de la Mama , Fluorodesoxiglucosa F18 , Adulto , Anciano , Neoplasias de la Mama/diagnóstico por imagen , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía de Emisión de Positrones , Estudios Prospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
9.
BMC Cancer ; 20(1): 326, 2020 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-32299391

RESUMEN

BACKGROUND: Neuroendocrine tumors (NETs) frequently overexpress somatostatin receptors (SSTRs), which is the molecular basis for 68Ga-DOTATOC positron-emission tomography (PET) and radiopeptide therapy (PRRT). However, SSTR expression fluctuates and can be subject to treatment-related changes. The aim of this retrospective study was to assess, which changes in PET and apparent diffusion coefficient (ADC) occur for different treatments and if pre-therapeutic 68Ga-DOTATOC-PET/MRI was able to predict treatment response to PRRT. METHODS: Patients with histopathologically confirmed NET, at least one liver metastasis > 1 cm and at least two 68Ga-DOTATOC-PET/MRI including ADC maps were eligible. 68Ga-DOTATOC-PET/MRI of up to 5 liver lesions per patients was subsequently analyzed. Extracted features comprise conventional PET parameters, such as maximum and mean standardized uptake value (SUVmax and SUVmean) and ADC values. Furthermore, textural features (TFs) from both modalities were extracted. In patients with multiple 68Ga-DOTATOC-PET/MRI a pair of 2 scans each was analyzed separately and the parameter changes between both scans calculated. The same image analysis was performed in patients with 68Ga-DOTATOC-PET/MRI before PRRT. Differences in PET and ADC maps parameters between PRRT-responders and non-responders were compared using Mann-Whitney test to test differences among groups for statistical significance. RESULTS: 29 pairs of 68Ga-DOTATOC-PET/MRI scans of 18 patients were eligible for the assessment of treatment-related changes. In 12 cases patients were treated with somatostatin analogues between scans, in 9 cases with PRRT and in 2 cases each patients received local treatment, chemotherapy and sunitinib. Treatment responders showed a statistically significant decrease in lesion volume and a borderline significant decrease in entropy on ADC maps when compared to non-responders. Patients treated with standalone SSA showed a borderline significant decrease in mean and maximum ADC, compared to patients treated with PRRT. No parameters were able to predict treatment response to PRRT on pre-therapeutic 68Ga-DOTATOC-PET/MRI. CONCLUSIONS: Patients responding to current treatment showed a statistically significant decrease in lesion volume on ADC maps and a borderline significant decrease in entropy. No statistically significant changes in PET parameters were observed. No PET or ADC maps parameters predicted treatment response to PRRT. However, the sample size of this preliminary study is small and further research needed.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Imagen de Difusión por Resonancia Magnética/métodos , Radioisótopos de Galio/metabolismo , Neoplasias Hepáticas/patología , Imagen Multimodal/métodos , Tumores Neuroendocrinos/patología , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/tratamiento farmacológico , Neoplasias Hepáticas/metabolismo , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Tumores Neuroendocrinos/tratamiento farmacológico , Tumores Neuroendocrinos/metabolismo , Pronóstico , Radiofármacos/metabolismo , Receptores de Somatostatina/metabolismo , Estudios Retrospectivos , Adulto Joven
10.
Eur J Nucl Med Mol Imaging ; 46(2): 437-445, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30074073

RESUMEN

OBJECTIVES: To compare the diagnostic performance of 18F-FDG PET/MRI and 18F-FDG PET/CT for primary and locoregional lymph node staging in non-small cell lung cancer (NSCLC). METHODS: In this prospective study, a total of 84 patients (51 men, 33 women, mean age 62.5 ± 9.1 years) with histopathologically confirmed NSCLC underwent 18F-FDG PET/CT followed by 18F-FDG PET/MRI in a single injection protocol. Two readers independently assessed T and N staging in separate sessions according to the seventh edition of the American Joint Committee on Cancer staging manual for 18F-FDG PET/CT and 18F-FDG PET/MRI, respectively. Histopathology as a reference standard was available for N staging in all 84 patients and for T staging in 39 patients. Differences in staging accuracy were assessed by McNemars chi2 test. The maximum standardized uptake value (SUVmax) and longitudinal diameters of primary tumors were correlated using Pearson's coefficients. RESULTS: T stage was categorized concordantly in 18F-FDG PET/MRI and 18F-FDG PET/CT in 38 of 39 (97.4%) patients. Herein, 18F-FDG PET/CT and 18F-FDG PET/MRI correctly determined the T stage in 92.3 and 89.7% of patients, respectively. N stage was categorized concordantly in 83 of 84 patients (98.8%). 18F-FDG PET/CT correctly determined the N stage in 78 of 84 patients (92.9%), while 18F-FDG PET/MRI correctly determined the N stage in 77 of 84 patients (91.7%). Differences between 18F-FDG PET/CT and 18F-FDG PET/MRI in T and N staging accuracy were not statistically significant (p > 0.5, each). Tumor size and SUVmax measurements derived from both imaging modalities exhibited excellent correlation (r = 0.963 and r = 0.901, respectively). CONCLUSION: 18F-FDG PET/MRI and 18F-FDG PET/CT show an equivalently high diagnostic performance for T and N staging in patients suffering from NSCLC.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/patología , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Prospectivos , Tórax
11.
Eur J Nucl Med Mol Imaging ; 46(7): 1542-1550, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30879122

RESUMEN

PURPOSE: To assess whole-body magnetic resonance imaging (wb-MRI) for detection of biochemical recurrence in comparison to 68Ga-prostate-specific membrane antigen positron emission tomography/computed tomography (68Ga-PSMA PET/CT) in prostate cancer (Pca) patients after radical prostatectomy. METHODS: This was a prospective trial including 28 consecutive patients (mean age 65.3 ± 9.0 years) with newly documented biochemical recurrence of Pca (mean prostate-specific antigen, PSA, 2.09 ± 1.95 ng/ml) following radical prostatectomy. All patients underwent both wb-MRI including a dedicated pelvic imaging protocol and PET/CT with 166 ± 35 MBq 68Ga-PSMA within a time window of 11 ± 10 days. PET/CT and MRI datasets were separately evaluated regarding Pca lesion count, type, localization and diagnostic confidence (three-point Likert scale, 1-3) by two nuclear medicine specialists and two radiologists, respectively. The reference standard was based on histopathological results, PSA levels following targeted salvage irradiation and follow-up imaging. Lesion-based and patient-based detection rates were compared using the chi-squared test. Differences in diagnostic confidence were assessed using the Welch test. RESULTS: A total of 56 Pca lesions were detected in 20 of the 28 patients. 68Ga-PSMA PET/CT detected 56 of 56 lesions (100%) in 20 patients (71.4%), while wb-MRI detected 13 lesions (23.2%) in 11 patients (39.3%). The higher detection rate with 68Ga-PSMA PET/CT was statistically significant on both a per-lesion basis (p < 0.001) and a per-patient basis (p = 0.0167). In 8 patients (28.6%) no relapse was detectable by either modality. All lesions detected by wb-MRI were also detected by 68Ga-PSMA PET/CT. Additionally, 68Ga-PSMA PET/CT provided superior diagnostic confidence in identifying Pca lesions (2.7 ± 0.7 vs. 2.3 ± 0.6, p = 0.044). CONCLUSION: 68Ga-PSMA PET/CT significantly out-performed wb-MRI in the detection of biochemical recurrence in Pca patients after radical prostatectomy.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Prostatectomía , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/cirugía , Anciano , Isótopos de Galio , Radioisótopos de Galio , Humanos , Masculino , Glicoproteínas de Membrana , Persona de Mediana Edad , Recurrencia Local de Neoplasia , Compuestos Organometálicos , Estudios Prospectivos , Próstata/patología , Antígeno Prostático Específico/análisis , Neoplasias de la Próstata/patología , Estándares de Referencia , Imagen de Cuerpo Entero
12.
Eur Radiol ; 29(5): 2581-2588, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30542752

RESUMEN

OBJECTIVES: To identify differences of radiocarpal cartilage alterations in osteoarthritis and arthritis using multiparametrical magnetic resonance imaging (MRI) comprising morphological and biochemical sequences without gadolinium-based contrast agent administration. METHODS: In this prospective study, multiparametrical MRI of the radiocarpal cartilage was performed in 47 participants (mean age, 46.6 ± 17.6 years; min., 20 years; max., 79 years) on a 3 Tesla MRI. The cohort consisted of 11 patients suffering from arthritis, 10 patients with osteoarthritis, 14 patients after distal radius fracture, and 12 healthy volunteers. The radiocarpal cartilage was assessed using morphological (DESS, TrueFISP) and biochemical (T2*) MRI sequences without the application of intravenous contrast agent. The modified Outerbridge classification system for morphological and region-of-interest analyses for biochemical analysis was applied to assess the degree of cartilage damage in each patient before data were statistically tested for significant difference between the groups using a post hoc Tukey test. RESULTS: In morphological imaging, cartilage damage was significantly more frequent in arthritis and osteoarthritis than in healthy volunteers (DESS: p = 0.01, p = 0.0004; TrueFISP: p = 0.02, p = 0.0001). In T2* imaging, patients with osteoarthritis showed higher cartilage damage compared to patients with arthritis (p = 0.01). CONCLUSION: With multiparametrical MRI, it is possible to identify differences of radiocarpal cartilage alterations of patients with arthritis and osteoarthritis using the combination of morphological and biochemical MR imaging of the radiocarpal cartilage without the application of contrast agent. Multiparametrical MRI without the usage of contrast agent may be a potential tool helping to distinguish both entities. KEY POINTS: • Multiparametrical MRI with morphological and biochemical sequences allows the differentiation of patients with arthritis and osteoarthritis. • High-resolution MRI of radiocarpal cartilage is possible without administration of contrast agent.


Asunto(s)
Artritis/diagnóstico , Cartílago Articular/patología , Gadolinio DTPA/administración & dosificación , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Medios de Contraste/administración & dosificación , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico , Estudios Prospectivos , Adulto Joven
13.
Eur J Nucl Med Mol Imaging ; 45(4): 622-629, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29164299

RESUMEN

PURPOSE: To evaluate the diagnostic performance of 18F-FDG PET/MRI for whole-body staging and potential changes in therapeutic management of women with suspected recurrent pelvic cancer in comparison with MRI alone. METHODS: Seventy-one consecutive women (54 ± 13 years, range: 25-80 years) with suspected recurrence of cervical (32), ovarian (26), endometrial (7), vulvar (4), and vaginal (2) cancer underwent PET/MRI including a diagnostic contrast-enhanced MRI protocol. PET/MRI and MRI datasets were separately evaluated regarding lesion count, localization, categorization (benign/malignant), and diagnostic confidence (3-point scale; 1-3) by two physicians. The reference standard was based on histopathology results and follow-up imaging. Diagnostic accuracy and proportions of malignant and benign lesions rated correctly were retrospectively compared using McNemar's chi2 test. Differences in diagnostic confidence were assessed by Wilcoxon test. RESULTS: Fifty-five patients showed cancer recurrence. PET/MRI correctly identified more patients with cancer recurrence than MRI alone (100% vs. 83.6%, p < 0.01). In contrast to PET/MRI, MRI alone missed 4/15 patients with pelvic recurrence and miscategorized 8/40 patients with distant metastases as having local recurrence only. Based on the reference standard, 241 lesions were detected in the study cohort (181 malignant, 60 benign). While PET/MRI provided correct identification of 181/181 (100%) malignant lesions, MRI alone correctly identified 135/181 (74.6%) malignant lesions, which was significantly less compared to PET/MRI (p < 0.001). PET/MRI offered superior diagnostic accuracy (99.2% vs. 79.3%, p < 0.001) and diagnostic confidence in the categorization of malignant lesions compared with MRI alone (2.7 ± 0.5 vs. 2.4 ± 0.7, p < 0.001). CONCLUSION: PET/MRI demonstrates excellent diagnostic performance and outperforms MRI alone for whole-body staging of women with suspected recurrent pelvic cancer, indicating potential changes in therapy management based on evaluation of local recurrence and distant metastatic spread.


Asunto(s)
Imagen por Resonancia Magnética , Recurrencia Local de Neoplasia/diagnóstico por imagen , Neoplasias Pélvicas/diagnóstico por imagen , Tomografía de Emisión de Positrones , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Fluorodesoxiglucosa F18 , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Imagen Multimodal , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Imagen de Cuerpo Entero
14.
Eur J Nucl Med Mol Imaging ; 45(12): 2093-2102, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29876618

RESUMEN

PURPOSE: To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. MATERIAL & METHODS: Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. RESULTS: Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. CONCLUSION: In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Melanoma/diagnóstico por imagen , Imagen Multimodal/métodos , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Ganglio Linfático Centinela/diagnóstico por imagen , Adulto , Anciano , Reacciones Falso Negativas , Femenino , Fluorodesoxiglucosa F18 , Humanos , Metástasis Linfática , Masculino , Melanoma/patología , Persona de Mediana Edad , Radiofármacos , Ganglio Linfático Centinela/patología , Biopsia del Ganglio Linfático Centinela
16.
Eur J Nucl Med Mol Imaging ; 45(1): 67-76, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28840302

RESUMEN

PURPOSE: The aim of the present study was to assess and compare the diagnostic performance of integrated PET/MRI and MRI alone for local tumor evaluation and whole-body tumor staging of primary cervical cancers. In addition, the corresponding impact on further patient management of the two imaging modalities was assessed. METHODS: A total of 53 consecutive patients with histopathological verification of a primary cervical cancer were prospectively enrolled for a whole-body 18F-FDG PET/MRI examination. Two experienced physicians analyzed the MRI data, in consensus, followed by a second reading session of the PET/MRI datasets. The readers were asked to perform a dedicated TNM staging in accordance with the 7th edition of the AJCC staging manual. Subsequently, the results of MRI and PET/MRI were discussed in a simulated interdisciplinary tumor board and therapeutic decisions based on both imaging modalities were recorded. Results from histopathology and cross-sectional imaging follow-up served as the reference standard. RESULTS: PET/MRI allowed for a correct determination of the T stage in 45/53 (85%) cases, while MRI alone enabled a correct identification of the tumor stage in 46/53 (87%) cases. In 24 of the 53 patients, lymph node metastases were present. For the detection of nodal-positive patients, sensitivity, specificity and accuracy of PET/MRI were 83%, 90% and 87%, respectively. The respective values for MRI alone were 71%, 83% and 77%. In addition, PET/MRI showed higher values for the detection of distant metastases than MRI alone (sensitivity: 87% vs. 67%, specificity: 92% vs. 90%, diagnostic accuracy: 91% vs. 83%). Among the patients with discrepant staging results in the two imaging modalities, PET/MRI enabled correct treatment recommendations for a higher number (n = 9) of patients than MRI alone (n = 3). CONCLUSION: The present results demonstrate the successful application of integrated PET/MRI imaging for whole-body tumor staging of cervical cancer patients, enabling improved treatment planning when compared to MRI alone.


Asunto(s)
Carcinoma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Neoplasias del Cuello Uterino/diagnóstico por imagen , Adulto , Anciano , Carcinoma/patología , Femenino , Fluorodesoxiglucosa F18 , Humanos , Imagen por Resonancia Magnética/normas , Persona de Mediana Edad , Imagen Multimodal/normas , Estadificación de Neoplasias , Tomografía de Emisión de Positrones/normas , Radiofármacos , Neoplasias del Cuello Uterino/patología
17.
Eur Radiol ; 28(8): 3221-3227, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29480342

RESUMEN

PURPOSE: To analyse technical success, complications, and short- and intermediate-term outcomes after heparin-bonded stent graft implantation for the treatment of major abdominal vessel injury after upper abdominal surgery. METHODS: This retrospective, IRB-approved analysis included 29 consecutive patients (female: n = 6, male: n = 23, mean age 65.9 ± 11.2 years). All patients underwent angiography and attempted heparin-bonded stent-graft implantation because of a major visceral arterial injury after upper abdominal surgery. Electronic clinical records, angiographic reports and imaging datasets were reviewed to assess technical success and complications. Telephone interviews were performed to obtain follow-up information and to estimate short- (> 30 days) and intermediate-term (> 90 days) outcomes. RESULTS: Successful stent graft placement was achieved in 82.8% (24/29). Peri-interventional complications were observed in 20.7% (6/29) and delayed, angiography-associated complications were observed in 34.5% (10/29) of the patients. Symptomatic re-bleeding occurred in 24.1% (7/29). Short-term survival (> 30 days) was 72.4% (21/29). Intermediate survival (> 90 days) was 37.9% (11/29). CONCLUSION: Treatment of major vascular injuries with heparin-bonded stent grafts is feasible with a high technical success rate. However, survival depends on the underlying surgical condition, making interdisciplinary patient management mandatory. KEY POINTS: • Stent graft implantation is challenging, but has a high technical success rate. • Complications are frequent but surgical conversion is rarely necessary. • Survival depends on the underlying surgical condition causing the vascular injury. • Interdisciplinary management is crucial for the survival of these patients.


Asunto(s)
Anticoagulantes/uso terapéutico , Arterias/lesiones , Implantación de Prótesis Vascular/métodos , Prótesis Vascular , Heparina/uso terapéutico , Stents , Lesiones del Sistema Vascular/cirugía , Anciano , Anciano de 80 o más Años , Angiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Retrospectivos , Análisis de Supervivencia
18.
Eur Radiol ; 27(2): 681-688, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27180186

RESUMEN

OBJECTIVE: To investigate whether differences in thoracic tumour staging between 18F-FDG PET/CT and PET/MR imaging lead to different therapeutic decisions in Non-Small Cell Lung Cancer (NSCLC). MATERIAL AND METHODS: Seventy-seven NSCLC patients that underwent whole-body 18F-FDG PET/CT from the base of skull to the upper thighs and thoracic PET/MR were enrolled in this retrospective study. Thoracic PET/CT and PET/MR images were staged according to the 7th edition of the AJCC staging manual. Staging results of both modalities were discussed separately in a simulated interdisciplinary tumour board and therapeutic decisions based on both imaging modalities were recorded. Descriptive statistics were used to compare the results and reasons for changes in the therapeutic decision were investigated. RESULTS: Staging results differed in 35 % of patients (27 patients) between thoracic PET/CT and PET/MR. Differences were detected when assessing the T-stage in 18 % (n = 14), the N-stage in 23 % (n = 18), and the M-stage in 1 % (n = 1). However, patient therapy management was changed in only six patients (8 %). CONCLUSION: Despite the variability of thoracic 18F-FDG PET/CT and PET/MR in TNM-staging, both modalities lead to comparable therapeutic decisions in patients suffering from NSCLC. Hence, 18F-FDG PET/MR can be considered an possible alternative to 18F-FDG PET/CT for clinical NSCLC staging. KEY POINTS: • PET/CT and PET/MR provide comparable results in early stages in NSCLC • Clinical impact of different staging results has not been investigated • PET/CT and PET/MR lead to comparable therapeutic decisions • PET/MR can be considered an alternative to PET/CT for NSCLC staging.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/patología , Fluorodesoxiglucosa F18 , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Estadificación de Neoplasias , Radiofármacos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X
19.
Eur J Nucl Med Mol Imaging ; 43(1): 92-102, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26243264

RESUMEN

PURPOSE: To evaluate the accuracy of integrated (18)F-FDG PET/MR imaging for locoregional tumour evaluation compared to (18)F-FDG PET/CT and MR imaging in initial tumour and recurrence diagnosis in histopathologically confirmed head and neck squamous cell carcinoma (HNSCC). METHODS: (18)F-FDG PET/CT and integrated (18)F-FDG PET/MR imaging were performed for initial tumour staging or recurrence diagnosis in 25 patients with HNSCC. MR, fused (18)F-FDG PET/CT and fused (18)F-FDG PET/MR images were analysed by two independent readers in separate sessions in random order. In initial tumour staging, T and N staging was performed while individual lesions were analysed in patients with suspected cancer recurrence. In T and N staging, histopathological results after tumour resection served as the reference standard while histopathological sampling as well as cross-sectional and clinical follow-up were accepted in cancer recurrence diagnosis. The diagnostic accuracy of each modality was calculated separately for T and N staging as well as for tumour recurrence, and compared using McNemar's test. Values of p <0.017 were considered statistically significant after Bonferroni correction. RESULTS: In 12 patients undergoing (18)F-FDG PET/CT and (18)F-FDG PET/MR for initial tumour staging, T staging was accurate in 50 % with MRI, in 59 % with PET/CT and in 75 % with PET/MR while N staging was accurate in 75 % with MRI, in 77 % with PET/CT and in 71 % with PET/MR in relation to the reference standard. No significant differences were observed in T and N staging among the three modalities (p > 0.017). In 13 patients undergoing hybrid imaging for cancer recurrence diagnosis, diagnostic accuracy was 57 % with MRI and in 72 % with (18)F-FDG PET/CT and (18)F-FDG PET/MR, respectively. Again, no significant differences were found among the three modalities (p > 0.017). CONCLUSION: In this initial study, no significant differences were found among (18)F-FDG PET/MR, (18)F-FDG PET/CT and MRI in local tumour staging and cancer recurrence diagnosis.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Fluorodesoxiglucosa F18 , Neoplasias de Cabeza y Cuello/diagnóstico , Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Anciano , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Femenino , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/patología , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Recurrencia , Estudios Retrospectivos , Sensibilidad y Especificidad
20.
Eur J Nucl Med Mol Imaging ; 42(12): 1814-24, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26199113

RESUMEN

PURPOSE: To assess the diagnostic value of integrated PET/MRI for whole-body staging of cervical cancer patients, as well as to investigate a potential association between PET/MRI derived functional parameters and prognostic factors of cervical cancer. METHODS: The present study was approved by the local institutional review board. Twenty-seven patients with histopathologically confirmed cervical cancer were prospectively enrolled in our study. All patients underwent a whole-body PET/MRI examination after written informed consent was obtained. Two radiologists separately evaluated the PET/MRI data sets regarding the determination of local tumor extent of primary cervical cancer lesions, as well as detection of nodal and distant metastases. Furthermore, SUV and ADC values of primary tumor lesions were analyzed and correlated with dedicated prognostic factors of cervical cancer. Results based on histopathology and cross-sectional imaging follow-up served as the reference standard. RESULTS: PET/MRI enabled the detection of all 27 primary tumor lesions of the uterine cervix and allowed for the correct determination of the T-stage in 23 (85 %) out of the 27 patients. Furthermore, the calculated sensitivity, specificity and diagnostic accuracy for the detection of nodal positive patients (n = 11) were 91 %, 94 % and 93 %, respectively. PET/MRI correctly identified regional metastatic disease (N1-stage) in 8/10 (80 %) patients and non-regional lymph node metastases in 5/5 (100 %) patients. In addition, quantitative analysis of PET and MRI derived functional parameters (SUV; ADC values) revealed a significant correlation with pathological grade and tumor size (p < 0.05). CONCLUSIONS: The present study demonstrates the high potential of integrated PET/MRI for the assessment of primary tumor and the detection of lymph node metastases in patients with cervical cancer. Providing additional prognostic information, PET/MRI may serve as a valuable diagnostic tool for cervical cancer patients in a pretreatment setting.


Asunto(s)
Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/patología , Imagen de Cuerpo Entero , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Metástasis de la Neoplasia , Estadificación de Neoplasias , Pronóstico , Neoplasias del Cuello Uterino/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA