Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Therm Biol ; 123: 103907, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38950497

RESUMEN

Recent heatwaves have highlighted the importance of accurate and continuous core temperature (TCORE) monitoring in sports settings. For example, accentuated rises in TCORE caused by physical exercises under environmental heat stress increase the risk of heat illnesses. Thus, using valid and reproducible devices is essential to ensure safe sports practice. In this study, we assessed the validity and reproducibility of the Calera Research Sensor (CRS) in estimating the TCORE of male and female participants during cycling exercise in a hot environment. Seven male (age: 36.2 ± 10.1 years) and eight female cyclists (age: 30.1 ± 5.0 years) underwent two identical cycling trials in a dry-bulb temperature of 32 °C and relative humidity of 60%. The protocol consisted of an initial 10-min rest followed by a 60-min exercise comprising 10 min at 20%, 25 min at 55%, and 25 min at 75% of maximal aerobic power, and an additional 25 min of post-exercise recovery. TCORE was recorded simultaneously every minute using a gastrointestinal capsule (TGi) and the CRS (TSENSOR). Bland-Altman analysis was performed to calculate bias, upper (LCS) and lower (LCI) concordance limits, and the 95% confidence interval (95%CI). The maximum acceptable difference between the two devices was predetermined at ±0.4 °C. A mixed linear model was used to assess the paired differences between the two measurement systems, considering the participants, trials, and environmental conditions as random effects and the cycling stages as fixed effects. An intra-class correlation coefficient (ICC) of 0.98 was recorded when analyzing data from the entire experiment. A non-significant bias value of 0.01 °C, LCS of 0.38 °C, LCI of -0.35 °C, and CI95% of ±0.36 °C were found. When analyzing data according to the participants' sex, CRS reproducibility was high in both sexes: ICC values of 0.98 and 0.99 were reported for males and females, respectively. CI95% was 0.35 °C in experiments with males and 0.37 °C with females, thereby falling within the acceptable margin of difference. Therefore, CRS was considered valid (compared to TGi) and reproducible in estimating TCORE in both sexes at various intensities of cycling exercise in the heat.


Asunto(s)
Ciclismo , Temperatura Corporal , Calor , Humanos , Masculino , Adulto , Femenino , Ciclismo/fisiología , Reproducibilidad de los Resultados , Ejercicio Físico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA