Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Retina ; 44(10): 1793-1799, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-39287542

RESUMEN

PURPOSE: To investigate the anatomical changes and surgical outcomes of hemi-temporal internal limiting membrane (ILM) peeling and conventional ILM peeling for idiopathic macular hole (MH). METHODS: This randomized controlled trial was conducted at 3 centers and included 50 participants with MHs of <400 µm in minimum diameter for a duration of <6 months. All participants had undergone vitrectomy with either hemi-temporal ILM peeling (Hemi group) or 360° ILM peeling (360° group) with an injection of 5% sulfur hexafluoride gas, with or without simultaneous cataract surgery, from July 2017 to January 2021. The rate of MH closure and distance of retinal migration were examined. RESULTS: Of 50 eyes randomized in the 3 centers, the Hemi group comprised 23 eyes, the 360° group 23 eyes, and 4 eyes were eliminated from final analysis. There was a significantly higher rate of primary MH closure in the 360° group (Hemi group: 73.9% vs. 360° group: 100%, P = 0.009). Retinal migration to the optic disk on the nasal side was significantly shorter in the Hemi group at 1, 3, and 6 months postoperatively than in the 360° group. There was no significant difference between the two groups in retinal migration to the optic disk on the temporal side. CONCLUSION: Nasal retinal migration in patients who underwent the hemi-temporal ILM peeling method was significantly less than in those who underwent the 360° ILM peeling method. However, less nasal retinal migration did not contribute to the MH closure rate.


Asunto(s)
Membrana Basal , Perforaciones de la Retina , Tomografía de Coherencia Óptica , Agudeza Visual , Vitrectomía , Humanos , Perforaciones de la Retina/cirugía , Perforaciones de la Retina/diagnóstico , Perforaciones de la Retina/fisiopatología , Femenino , Masculino , Vitrectomía/métodos , Anciano , Agudeza Visual/fisiología , Membrana Basal/cirugía , Tomografía de Coherencia Óptica/métodos , Resultado del Tratamiento , Persona de Mediana Edad , Estudios de Seguimiento , Membrana Epirretinal/cirugía , Membrana Epirretinal/fisiopatología , Estudios Prospectivos , Endotaponamiento/métodos , Hexafluoruro de Azufre/administración & dosificación
2.
Curr Issues Mol Biol ; 45(9): 7097-7109, 2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37754233

RESUMEN

Nicotinamide riboside (NR), a precursor of nicotinamide adenine dinucleotide (NAD+), has been studied to support human health against metabolic stress, cardiovascular disease, and neurodegenerative disease. In the present study, we investigated the effects of oral NR on axonal damage in a rat ocular hypertension model. Intraocular pressure (IOP) elevation was induced by laser irradiation and then the rats received oral NR of 1000 mg/kg/day daily. IOP elevation was seen 7, 14, and 21 days after laser irradiation compared with the controls. We confirmed that oral NR administration significantly increased NAD+ levels in the retina. After 3-week oral administration of NR, morphometric analysis of optic nerve cross-sections showed that the number of axons was protected compared with that in the untreated ocular hypertension group. Oral NR administration significantly prevented retinal ganglion cell (RGC) fiber loss in retinal flat mounts, as shown by neurofilament immunostaining. Immunoblotting samples from the optic nerves showed that oral NR administration augmented the phosphorylated adenosine monophosphate-activated protein kinase (p-AMPK) level in rats with and without ocular hypertension induction. Immunohistochemical analysis showed that some p-AMPK-immunopositive fibers were colocalized with neurofilament immunoreactivity in the control group, and oral NR administration enhanced p-AMPK immunopositivity. Our findings suggest that oral NR administration protects against glaucomatous RGC axonal degeneration with the possible upregulation of p-AMPK.

3.
Ophthalmic Res ; 65(2): 162-170, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34788757

RESUMEN

INTRODUCTION: The aim of the study was to investigate the outcomes of vitrectomy with fovea-sparing internal limiting membrane (ILM) peeling (FSIP) for epiretinal membrane (ERM) foveoschisis based on new optical coherence tomography definitions. METHODS: Twenty-three eyes of 22 patients (69.7 ± 9.9 years old) who underwent vitrectomy with FSIP without gas tamponade for ERM foveoschisis were analyzed. All patients underwent follow-up examinations for at least 12 months. In the FSIP technique, the ILM is peeled off in a donut shape, preserving the foveal ILM. The logarithm of the minimal angle of resolution best-corrected visual acuity (BCVA), central macular thickness (CMT), and surgical complications were examined. RESULTS: The BCVA at 12 months improved significantly from baseline (p < 0.001). Baseline ellipsoid zone defects were found in 2 eyes (9%), and all defective eyes had recovered at 12 months. CMT decreased significantly from baseline (p < 0.001). Acute macular edema, full-thickness macular hole, and recurrence of ERM were not observed during follow-up. DISCUSSION/CONCLUSION: FSIP achieved good visual outcome and retinal morphological change. Moreover, FSIP might avoid acute macular edema in ERM foveoschisis surgery.


Asunto(s)
Membrana Epirretinal , Edema Macular , Miopía Degenerativa , Retinosquisis , Anciano , Membrana Basal/cirugía , Membrana Epirretinal/complicaciones , Membrana Epirretinal/diagnóstico , Membrana Epirretinal/cirugía , Humanos , Edema Macular/cirugía , Persona de Mediana Edad , Miopía Degenerativa/cirugía , Retinosquisis/complicaciones , Retinosquisis/diagnóstico , Retinosquisis/cirugía , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual , Vitrectomía/métodos
4.
BMC Ophthalmol ; 21(1): 8, 2021 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-33407262

RESUMEN

BACKGROUNDS: However there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar. METHODS: Nineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o'clock, 2 mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications. RESULTS: The 19 eyes were followed up for 1 month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.06 ± 0.63 and 0.40 ± 0.26, respectively (p < 0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27 ± 0.51 and 0.06 ± 0.15, respectively (p = 0.09). The mean corneal endothelial cell density was 2406 ± 625 to 2004 ± 759 cells/mm2 at 1 month (p = 0.13). The mean IOL tilt was 3.52 ± 3.00°, and the mean IOL decentration was 0.39 ± 0.39 mm. There was no correlation among IOL tilt, decentration and BCVA (p > 0.05). The mean prediction error of the target refraction was - 0.03 ± 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred. CONCLUSIONS: IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Estudios Retrospectivos , Esclerótica/cirugía , Instrumentos Quirúrgicos , Técnicas de Sutura
5.
J Clin Med ; 11(17)2022 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-36078984

RESUMEN

We investigate-d whether biomarkers such as red blood cell hematocrit (Hct), platelet count (PLT), mean platelet volume (MPV), and platelet distribution width (PDW) are useful prognostic indicators of postoperative macular edema (ME) after vitrectomy for proliferative diabetic retinopathy (PDR). A total of 42 eyes of 42 patients with PDR who underwent vitrectomy between January 2018 and May 2020 were analyzed retrospectively. We divided them into two groups according to whether treatment was required for postoperative ME and compared the relationship between Hct, PLT, MPV, and PDW and the onset of postoperative ME. The group that received postoperative treatment (group T) comprised 11 eyes of 11 patients, and the group that did not (group N) comprised 31 eyes of 31 patients. The age (years) was 52.0 ± 3.1 in group T and 60.0 ± 11.6 in group N. When appropriate statistical analysis was performed for comparison between groups, significant differences were found in age (p = 0.05), insulin use (p = 0.03), preoperative intraocular pressure (p = 0.05), diastolic blood pressure (p = 0.03), and Hct (p = 0.04). Multivariate logistic regression analysis was performed, and a significant difference was found in Hct (p = 0.02). These results suggest that Hct might be useful as a predictor of ME after PDR surgery.

6.
CEN Case Rep ; 9(4): 295-300, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32279192

RESUMEN

Nintedanib, a triple tyrosine kinase inhibitor of vascular endothelial growth factor receptor, platelet-derived growth factor receptor, and fibroblast growth factor receptor, has been used in idiopathic pulmonary fibrosis and adenocarcinoma in advanced non-small cell lung cancer. Although vascular endothelial growth factor inhibitors have been reported to cause endothelial injury and glomerular microangiopathy, nintedanib-induced glomerular microangiopathy has not been reported. A 68-year-old man with a history of primary aldosteronism, idiopathic pulmonary fibrosis, and pleomorphic carcinoma of the lung developed proteinuria and leg edema after nintedanib initiation. Kidney biopsy revealed prominent endothelial and mesangial injury. Proteinuria improved after nintedanib withdrawal. To the best of our knowledge, this is the second case report of nintedanib-induced glomerular microangiopathy. Although the incidence of nephropathy among patients receiving nintedanib is unknown at this moment, we recommend monitoring urinary protein excretion and blood pressure in patients receiving nintedanib and performing kidney biopsy to determine any histopathological change.


Asunto(s)
Fibrosis Pulmonar Idiopática/tratamiento farmacológico , Indoles/efectos adversos , Enfermedades Renales/inducido químicamente , Inhibidores de Proteínas Quinasas/efectos adversos , Proteinuria/inducido químicamente , Anciano , Carcinoma/diagnóstico , Carcinoma/tratamiento farmacológico , Endotelio Vascular/efectos de los fármacos , Endotelio Vascular/lesiones , Mesangio Glomerular/irrigación sanguínea , Mesangio Glomerular/efectos de los fármacos , Mesangio Glomerular/lesiones , Humanos , Hiperaldosteronismo/tratamiento farmacológico , Indoles/administración & dosificación , Indoles/uso terapéutico , Riñón/irrigación sanguínea , Riñón/efectos de los fármacos , Enfermedades Renales/patología , Neoplasias Pulmonares/patología , Masculino , Inhibidores de Proteínas Quinasas/administración & dosificación , Inhibidores de Proteínas Quinasas/uso terapéutico , Receptores de Factores de Crecimiento de Fibroblastos/efectos de los fármacos , Receptores del Factor de Crecimiento Derivado de Plaquetas/efectos de los fármacos , Receptores de Factores de Crecimiento Endotelial Vascular/efectos de los fármacos , Microangiopatías Trombóticas/inducido químicamente , Microangiopatías Trombóticas/diagnóstico , Privación de Tratamiento
7.
Sci Rep ; 10(1): 10837, 2020 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-32616724

RESUMEN

Two large clinical studies showed that fenofibrate, a commonly used peroxisome proliferator-activated receptor α (PPARα) agonist, has protective effects against diabetic retinopathy. However, the underlying mechanism has not been clarified. We performed genome-wide analyses of gene expression and PPARα binding sites in vascular endothelial cells treated with the selective PPARα modulator pemafibrate and identified 221 target genes of PPARα including THBD, which encodes thrombomodulin (TM). ChIP-qPCR and luciferase reporter analyses showed that PPARα directly regulated THBD expression via binding to the promoter. In the rat diabetic retina, treatment with pemafibrate inhibited the expression of inflammatory molecules such as VCAM-1 and MCP1, and these effects were attenuated by intravitreal injection of small interfering RNA targeted to THBD. Furthermore, pemafibrate treatment inhibited diabetes-induced vascular leukostasis and leakage through the upregulation of THBD. Our results indicate that PPARα activation inhibits inflammatory and vasopermeable responses in the diabetic retina through the upregulation of TM.


Asunto(s)
Biomarcadores/análisis , Diabetes Mellitus Experimental/complicaciones , Diabetes Mellitus Tipo 1/complicaciones , Retinopatía Diabética/diagnóstico , Modelos Animales de Enfermedad , PPAR alfa/metabolismo , Trombomodulina/metabolismo , Animales , Retinopatía Diabética/etiología , Retinopatía Diabética/metabolismo , Endotelio Vascular/metabolismo , Endotelio Vascular/patología , Estudio de Asociación del Genoma Completo , Masculino , PPAR alfa/genética , Ratas , Ratas Wistar , Trombomodulina/genética
8.
Clin Ophthalmol ; 12: 2409-2414, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30538424

RESUMEN

PURPOSE: The purpose of this study was to compare straight and angled incisions in 27-gauge microincision vitrectomy in patients with epiretinal membrane (ERM). METHODS: Seventy-three eyes of 68 patients with ERM who underwent straight (35 eyes) or angled incision (38 eyes) for 27-gauge microincision vitrectomy were retrospectively evaluated. RESULTS: No statistically significant difference was found between the two groups in postoperative logarithm of minimal angle of resolution best-corrected visual acuity. The intraocular pressure and rate of hypotony 1 day postoperatively did not differ between the straight- and angled-incision groups (intraocular pressure: 11.5 vs 13.4 mmHg, respectively; rate of hypotony: 20% vs 8%, respectively). Surgical wound closing occurred by postoperative day 10 in both groups. CONCLUSION: A straight incision is as safe and useful in ERM vitrectomy as an angled one.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA