Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
ScientificWorldJournal ; 2022: 9618344, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35645632

RESUMEN

Ebastine is a long-acting, nonsedating, second-generation antihistaminic drug that prevents histamine action, mainly in immediate hypersensitivity. This project was aimed to formulate and characterize orodispersible tablets of ebastine, utilizing different proportions of three disintegrants, namely crospovidone, sodium starch glycolate, and coprocessed superdisintegrant. Initially, fifteen trial batches of ebastine orodispersible tablets were outlined using the central composite design of Minitab software. The tablets were formulated by the direct compression method. The compressed tablets were then evaluated for precompression and postcompression physicochemical parameters, such as angle of repose, Carr's index, Hausner's ratio, hardness, thickness, weight variation, drug content, friability, wetting time, disintegration time, dispersion time, and water absorption ratio. The in vitro dissolution test was conducted according to Indian Pharmacopeia 2018, with the help of the rotating paddle method using 0.5% w/v sodium lauryl sulfate buffer in 0.1 N HCl. For the optimized batch (8th batch), all the physicochemical parameters like angle of repose (33.77°), Carr's index (19.34%), Hausner's ratio (1.24), weight variation (202.5 mg), hardness (4.3 kg/cm2), friability (0.44%), thickness (3.16 mm), dissolution (95.78%), and drug content (101.67%) were within the acceptable limit as per Indian Pharmacopeia 2018. The wetting time, disintegration time, dispersion time, and water absorption ratio were reported to be 25.1 seconds, 16.0 seconds, 38.6 seconds, and 91.92%, respectively. Hence, the results suggested that orodispersible tablets of ebastine can be formulated. Furthermore, the mixing of crospovidone, sodium starch glycolate, and coprocessed super disintegrants can result in excellent desirable properties in the orodispersible tablet.


Asunto(s)
Química Farmacéutica , Povidona , Butirofenonas , Química Farmacéutica/métodos , Piperidinas , Control de Calidad , Solubilidad , Comprimidos/química , Agua
2.
Neuron ; 95(6): 1381-1394.e6, 2017 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-28910621

RESUMEN

Understanding the detailed dynamics of neuronal networks will require the simultaneous measurement of spike trains from hundreds of neurons (or more). Currently, approaches to extracting spike times and labels from raw data are time consuming, lack standardization, and involve manual intervention, making it difficult to maintain data provenance and assess the quality of scientific results. Here, we describe an automated clustering approach and associated software package that addresses these problems and provides novel cluster quality metrics. We show that our approach has accuracy comparable to or exceeding that achieved using manual or semi-manual techniques with desktop central processing unit (CPU) runtimes faster than acquisition time for up to hundreds of electrodes. Moreover, a single choice of parameters in the algorithm is effective for a variety of electrode geometries and across multiple brain regions. This algorithm has the potential to enable reproducible and automated spike sorting of larger scale recordings than is currently possible.


Asunto(s)
Potenciales de Acción/fisiología , Algoritmos , Neuronas/fisiología , Procesamiento de Señales Asistido por Computador , Programas Informáticos , Animales , Automatización , Encéfalo/fisiología , Masculino , Ratas
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 1528-1531, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28268617

RESUMEN

High-density electrocorticography (ECoG) arrays are promising interfaces for high-resolution neural recording from the cortical surface. Commercial options for high-density arrays are limited, and historically tradeoffs must be made between spatial coverage and electrode density. However, thin-film technology is a promising alternative for generating electrode arrays capable of large area coverage and high channel count, with resolution on the order of cortical columns in the functional surface unit of a human gyrus. Here, we evaluate the sensing performance of a high-density thin-film 128-electrode array designed specifically for recording the distributed neural activity of a single human cortical gyrus. We found robust field potential responses throughout the superior temporal gyrus evoked by speech sounds, and clear phonetic feature selectivity at the resolution of 2 mm inter-electrode distance. Decoding accuracy improved with increasing density of electrodes over all three patients tested. Thin-film ECoG has significant potential for high-density neural interface applications at the scale of a human gyrus.


Asunto(s)
Electrocorticografía , Corteza Cerebral , Electrodos Implantados , Electroencefalografía , Humanos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 4471-4474, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28269271

RESUMEN

A distributed, modular, intelligent, and efficient neuromodulation device, called OMNI, is presented. It supports closed-loop recording and stimulation on 256 channels from up to 4 physically distinct neuromodulation modules placed in any configuration around the brain, hence offering the capability of addressing neural disorders that are presented at the network level. The specific focus of this paper is the communication and power distribution network that enables the modular and distributed nature of the device.


Asunto(s)
Encéfalo/fisiología , Terapia por Estimulación Eléctrica/instrumentación , Redes de Comunicación de Computadores , Suministros de Energía Eléctrica , Diseño de Equipo , Humanos
5.
Artículo en Inglés | MEDLINE | ID: mdl-25569992

RESUMEN

We report a novel method to fabricate chronic neural interfaces with the intent to combine the reliability and lifetime of bulk metal electrodes, with the miniaturization and mechanical flexibility of thin-film polymer microelectrode arrays. 10 µm thick platinum discs were laser cut from a foil into the shape of individual electrodes, and coated with gold on the backside. The discs were bonded to a microelectrode array with gold bond pads via gold-gold inter-diffusion using a flipchip bonder. Electrode bonding and adhesion was characterized using mechanical shear testing and electrical testing. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and cyclic voltammetry. Biphasic electrical pulsing experiments were conducted on the bonded electrodes to study degradation of the electrode; the preliminary results show that the electrodes can withstand at least 4,900 million pulses with no adverse electrochemical or visual degradation. Overall, this is a promising new method for fabricating chronic neural electrodes for stimulation or recording that combines the reliability of commercial bulk electrodes with the miniaturization and versatility of microfabricated technologies.


Asunto(s)
Estimulación Encefálica Profunda/instrumentación , Microelectrodos , Diseño de Equipo
6.
Artículo en Inglés | MEDLINE | ID: mdl-25571175

RESUMEN

The translation of advances in neural stimulation and recording research into clinical practice hinges on the ability to perform chronic experiments in awake and behaving animal models. Advances in microelectrode array technology, most notably flexible polymer arrays, have significantly improved reliability of the neural interface. However, electrical connector technology has lagged and is prone to failure from non-biocompatibility, large size, contamination, corrosion, and difficulty of use. We present a novel chronic, percutaneous electrical connector system that is suitable for neural stimulation and recording. This system features biocompatible materials, low connect and disconnect forces, passive alignment, and a protective cap during non-use. We have successfully designed, assembled, and tested in vitro both a 16-channel system and a high density 64-channel system. Custom, polyimide, 16-channel, microelectrode arrays were electrically assembled with the connector system and tested using cyclic voltammetry and electrochemical impedance spectroscopy. This connector system is versatile and can be used with a variety of microelectrode array technologies for chronic studies.


Asunto(s)
Microelectrodos , Animales , Estimulación Eléctrica , Electricidad , Electroquímica
7.
Artículo en Inglés | MEDLINE | ID: mdl-25571565

RESUMEN

The brain is a massively interconnected network of specialized circuits. Even primary sensory areas, once thought to support relatively simple, feed-forward processing, are now known to be parts of complex feedback circuits. All brain functions depend on millisecond timescale interactions across these brain networks. Current approaches cannot measure or manipulate such large-scale interactions. Here we demonstrate that polymer-based, penetrating, micro-electrode arrays can provide high quality neural recordings from awake, behaving animals over periods of months. Our results indicate that polymer electrodes are a viable substrate for the development of systems that can record from thousands of channels across months to years. This is our first step towards developing a 1000+ electrode system capable of providing high-quality, long-term neural recordings.


Asunto(s)
Mapeo Encefálico/métodos , Electrodos Implantados , Neuronas/patología , Polímeros/química , Procesamiento de Señales Asistido por Computador , Animales , Animales Modificados Genéticamente , Encéfalo/fisiología , Electrofisiología/métodos , Diseño de Equipo , Ratas , Ratas Long-Evans , Interfaz Usuario-Computador
8.
Artículo en Inglés | MEDLINE | ID: mdl-24109995

RESUMEN

We report a novel nano-cluster platinum (NCPt) film that exhibits enhanced performance as an electrode material for neural stimulation applications. Nano-cluster films were deposited using a custom physical vapor deposition process and patterned on a flexible polyimide microelectrode array using semiconductor processing technology. Electrode performance was characterized in vitro using electrochemical impedance spectroscopy and compared with sputtered thinfilm platinum (TFPt) electrodes. We characterized electrode impedance, charge storage capacity, voltage transient properties, and relative surface area enhancement in vitro. Preliminary lifetime testing of the electrode reveals that the NCPt electrodes degrade more slowly than TFPt electrodes. The combination of material biocompatibility, electrochemical performance, and preliminary lifetime results point to a promising new electrode material for neural interface devices.


Asunto(s)
Estimulación Eléctrica/métodos , Platino (Metal)/química , Impedancia Eléctrica , Técnicas Electroquímicas , Electrodos , Electrones , Microscopía Electrónica de Rastreo , Microtecnología , Nanopartículas/química , Imagen Óptica
9.
J Vis Exp ; (79): e50609, 2013 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-24121443

RESUMEN

Microelectrode arrays for neural interface devices that are made of biocompatible thin-film polymer are expected to have extended functional lifetime because the flexible material may minimize adverse tissue response caused by micromotion. However, their flexibility prevents them from being accurately inserted into neural tissue. This article demonstrates a method to temporarily attach a flexible microelectrode probe to a rigid stiffener using biodissolvable polyethylene glycol (PEG) to facilitate precise, surgical insertion of the probe. A unique stiffener design allows for uniform distribution of the PEG adhesive along the length of the probe. Flip-chip bonding, a common tool used in microelectronics packaging, enables accurate and repeatable alignment and attachment of the probe to the stiffener. The probe and stiffener are surgically implanted together, then the PEG is allowed to dissolve so that the stiffener can be extracted leaving the probe in place. Finally, an in vitro test method is used to evaluate stiffener extraction in an agarose gel model of brain tissue. This approach to implantation has proven particularly advantageous for longer flexible probes (>3 mm). It also provides a feasible method to implant dual-sided flexible probes. To date, the technique has been used to obtain various in vivo recording data from the rat cortex.


Asunto(s)
Implantes Absorbibles , Adhesivos/química , Encéfalo/fisiología , Microelectrodos , Polietilenglicoles/química , Animales , Encéfalo/cirugía , Ratones
10.
Artículo en Inglés | MEDLINE | ID: mdl-24110897

RESUMEN

We present here a microfabricated, multi-functional neural interface with the ability to selectively apply electrical and chemical stimuli, while simultaneously monitoring both electrical and chemical activity in the brain. Such a comprehensive approach is required to understand and treat neuropsychiatric disorders, such as major depressive disorder (MDD), and to understand the mechanisms underlying treatments, such as pharmaceutical therapies and deep brain stimulation (DBS). The polymer-based, multi-functional neural interface is capable of electrical stimulation and recording, targeted drug delivery, and electrochemical sensing. A variety of different electrode and fluidic channel arrangements are possible with this fabrication process. Preliminary testing has shown the suitability of these neural interfaces for in vivo electrical stimulation and recording, as well as in vitro chemical sensing. Testing of the in vitro drug delivery and combined in vivo functionalities this neural interface are currently underway.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Electrodos Implantados , Polímeros/química , Encéfalo/fisiología , Estimulación Encefálica Profunda/instrumentación , Trastorno Depresivo Mayor , Estimulación Eléctrica/instrumentación , Electroquímica/instrumentación , Electroquímica/métodos , Diseño de Equipo , Humanos , Sistemas Hombre-Máquina , Microtecnología , Neuronas/metabolismo
11.
Annu Int Conf IEEE Eng Med Biol Soc ; 2012: 5999-6002, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23367296

RESUMEN

We present here a demonstration of a dual-sided, 4-layer metal, polyimide-based electrode array suitable for neural stimulation and recording. The fabrication process outlined here utilizes simple polymer and metal deposition and etching steps, with no potentially harmful backside etches or long exposures to extremely toxic chemicals. These polyimide-based electrode arrays have been tested to ensure they are fully biocompatible and suitable for long-term implantation; their flexibility minimizes the injury and glial scarring that can occur at the implantation site. The creation of dual-side electrode arrays with more than two layers of trace metal enables the fabrication of neural probes with more electrodes without a significant increase in probe size. This allows for more stimulation/recording sites without inducing additional injury and glial scarring.


Asunto(s)
Microelectrodos , Neuronas/fisiología , Técnicas Electroquímicas , Diseño de Equipo
12.
Artículo en Inglés | MEDLINE | ID: mdl-23367295

RESUMEN

We present here a microfabrication process for multi-layer metal, multi-site, polymer-based neural probes. The process has been used to generate 1-, 2-, and 4-layer trace metal neural probes with highly uniform and reproducible electrode characteristics. Typically, increasing the number of metal layers is assumed to both reduce the width of the neural probes and minimize the injury and glial scarring caused at the implantation site. We show, however, that increasing the number of trace metal layers does not always result in the minimal probe cross-sectional area. A thorough design analysis reveals that the electrode size, along with other design parameters, have interacting effects on the probe cross-sectional area. Moreover, increasing the trace metal layers in the neural probes also increases the design and fabrication cost/time, as well as the likelihood of probe failure. Consequently, all of these factors must be considered when designing a multi-site, neural probe with the objective of minimizing tissue damage.


Asunto(s)
Materiales Biocompatibles , Diseño de Equipo , Metales/química , Neuronas/fisiología
13.
Artículo en Inglés | MEDLINE | ID: mdl-23366031

RESUMEN

Flexible polymer probes are expected to enable extended interaction with neural tissue by minimizing damage from micromotion and reducing inflammatory tissue response. However, their flexibility prevents them from being easily inserted into the tissue. This paper describes an approach for temporarily attaching a silicon stiffener with biodissolvable polyethylene glycol (PEG) so that the stiffener can be released from the probe and extracted shortly after probe placement. A novel stiffener design with wicking channels, along with flip-chip technology, enable accurate alignment of the probe to the stiffener, as well as uniform distribution of the PEG adhesive. Insertion, extraction, and electrode function were tested in both agarose gel and a rat brain. Several geometric and material parameters were tested to minimize probe displacement during stiffener extraction. We demonstrated average probe displacement of 28 ± 9 µm.


Asunto(s)
Materiales Biocompatibles/farmacología , Encéfalo , Polietilenglicoles/farmacología , Silicio/farmacología , Adhesivos Tisulares/farmacología , Animales , Materiales Biocompatibles/química , Electrodos , Polietilenglicoles/química , Ratas , Sefarosa/química , Sefarosa/farmacología , Silicio/química , Adhesivos Tisulares/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA