Kardiologiia ; 28(7): 52-6, 1988 Jul.
Artículo en Ruso | MEDLINE | ID: mdl-3062224

RESUMEN

Comparative value of minute flow volume measurement by radiocardiography, echocardiography, tetrapolar chest rheography and ultrasonic impulse doppler flowmetry was assessed in 30 individuals. Radiocardiography was often associated with overstated values and could not be used for minute volume monitoring. Tetrapolar chest rheography was also associated with overstated values in cases of left-ventricular insufficiency, and inadequately overstated values in 6% of normal subjects and understated values in 1%. Ultrasonic impulse doppler flowmetry was not possible in 8% of the cases because of poor echo. Ultrasonic impulse doppler flowmetry and echocardiography were found to be the most promising and clinically suitable procedures.


Asunto(s)
Volumen Sanguíneo , Insuficiencia Cardíaca/fisiopatología , Adulto , Anciano , Determinación del Volumen Sanguíneo/métodos , Angiografía Coronaria , Reacciones Falso Negativas , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Pletismografía de Impedancia , Ultrasonografía/métodos