Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 93(45): 15033-15041, 2021 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-34730944

RESUMEN

Rapid and automated detection of acute myocardial infarction (AMI) at its developing stage is very important due to its high mortality rate. To quantitatively diagnose AMI, Myo, CK-MB, and cTnI are chosen as three biomarkers, which are usually detected through an immunosorbent assay, such as the enzyme-linked immunosorbent assay. However, the approach poses many drawbacks, such as long detection time, the cumbersome process, the need for professionals, and the difficulty of realizing automatic operation. Here, a multichannel digital microfluidic (DMF) thermal control chip integrated with a sandwich-based immunoassay strategy is proposed for the automated, rapid, and sensitive detection of AMI biomarkers. A miniaturized temperature control module is integrated on the back of the DMF chip, meeting the temperature requirement for the immunoassay. With this DMF thermal control chip, sample and reagent consumption are reduced to several microliters, significantly alleviating reagent consumption and sample dependence, and the automated and multichannel detection of biomarkers can be achieved. In this work, the simultaneously noninvasive detection of the human serum sample containing the three biomarkers of AMI is also achieved within 30 min, which improves the diagnostic accuracy of AMI. Due to the features of automation and miniaturization, the multichannel immunosensor can be used in community hospitals to increase the speed of diagnosis of patients with various acute diseases.


Asunto(s)
Técnicas Biosensibles , Infarto del Miocardio , Biomarcadores , Forma MB de la Creatina-Quinasa , Humanos , Inmunoensayo , Microfluídica , Infarto del Miocardio/diagnóstico
2.
Biomed Microdevices ; 18(6): 104, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27796675

RESUMEN

Applications of membranes in microfluidics solved many thorny problems for analytical chemistry and bioscience, so that the use of membranes in microfluidics has been a topic of growing interest. Many different examples have been reported, demonstrating the versatile use of membranes. This work reviews a lot of applications of membranes in microfluidics. Membranes in microfluidics for applications including chemical reagents detection, gas detection, drug screening, cell, protein, microreactor, electrokinetical fluid, pump and valve and fluid transport control and so on, have been analyzed and discussed. In addition, the definition and basic concepts of membranes are summed up. And the methods of manufacturing membranes in microfluidics are discussed. This paper will provide a helpful reference to researchers who want to study applications of membranes in microfluidics.


Asunto(s)
Dispositivos Laboratorio en un Chip , Membranas Artificiales
3.
J Food Sci Technol ; 53(1): 915-9, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26788016

RESUMEN

A microreactor for the chemiluminescence detection of copper (II) in water samples, based on the measurement of light emitted from the copper (II) catalysed oxidation of 1,10-phenanthroline by hydrogen peroxide in basic aqueous solution, is presented. Polymethyl methacrylate (PMMA) was chose as material for fabricating the microreactor with mill and hot bonding method. Optimized reagents conditions were found to be 6.3 × 10(-5)mol/L 1,10-phenanthroline, 1.5 × 10(-3)mol/L hydrogen peroxide, 7.0 × 10(-2)mol/L sodium hydroxide and 2.4 × 10(-5)mol/L Hexadecyl trimethyl ammonium Bromide (CTMAB). In the continuous flow injection mode the system can perform fully automated detection with a reagent consumption of only 3.5 µL each time. The linear range of the Cu (II) ions concentration was 1.5 × 10(-8) mol/L to 1.0 × 10(-4) mol/L, and the detection limit was 9.4 × 10(-9)mol/L with the S/N ratio of 4. The relative standard deviation was 3.0 % for 2.0 × 10(-6) mol/L Cu (II) ions (n = 10). The most obvious features of the detection method are simplicity, rapidity and easy fabrication of the microreactor.

4.
iScience ; 27(4): 109481, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38551006

RESUMEN

It is still a great challenge for the flexible piezoresistive pressure sensors to simultaneously achieve wide linearity and high sensitivity. Herein, we propose a high-performance textile pressure sensor based on chitosan (CTS)/MXene fiber. The hierarchical "point to line" architecture enables the pressure sensor with high sensitivity of 1.16 kPa-1 over an ultrawide linear range of 1.5 MPa. Furthermore, the CTS/MXene pressure sensor possesses a low fatigue over 1000 loading/unloading cycles under 1.5 MPa pressure load, attributed to the strong chemical bonding between CTS fiber and MXene and excellent mechanical stability. Besides, the proposed sensor shows good antibacterial effect benefiting from the strong interaction between polycationic structure of CTS/MXene and the predominantly anionic components of bacteria surface. The sensor is also applied to detect real-time human action, an overall classification accuracy of 98.61% based on deep neural network-convolutional neural network (CNN) for six human actions is realized.

5.
Lab Chip ; 23(20): 4390-4399, 2023 10 10.
Artículo en Inglés | MEDLINE | ID: mdl-37721054

RESUMEN

The occurrence, development and prediction of various biological processes and diseases are inseparable from the protein-protein interaction (PPI), so it is extremely meaningful to perfect PPI networks. However, shortcomings of traditional detection methods, such as protein degradation, long detection time, complex operation, poor automation and high cost, restrict the rapid development of PPI networks. Here, a low-temperature digital microfluidic (LTDMF) system-based PPI detection box (LTDMF-PPI-Box) was developed to achieve rapid, lossless and efficient PPI detection. It consists of a PMMA shell, LTDMF-PPI and an integrated temperature control system. LTDMF reduces the PPI detection time from tens of hours to 1.5 hours by programmatically controlling the movement of droplets. Moreover, an integrated thermoelectric cooler (TEC) ensures an operating temperature of 4 °C, resulting in a protein protection up to 90%. The interaction between RILP protein and Rab26 protein which has a close connection to insulin secretion was demonstrated as a prototype to illustrate the feasibility of the LTDMF-PPI-Box. LTDMF with automation characteristics is capable of meeting the requirement of high-throughput screening of interacting proteins; therefore, the LTDMF-PPI-Box is expected to accelerate the establishment of the PPI network in the future.


Asunto(s)
Microfluídica , Mapeo de Interacción de Proteínas , Mapeo de Interacción de Proteínas/métodos , Temperatura , Algoritmos , Mapas de Interacción de Proteínas , Proteínas/metabolismo
6.
Biosens Bioelectron ; 237: 115523, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37451024

RESUMEN

Respiratory viruses have long been a major cause of a global pandemic, emphasizing the urgent need for high-sensitivity diagnostic tools. Typical PCR technology can only determine the type of virus in the sample, which is unable to detect different variants of the same virus without costly and time-consuming gene sequencing. Here, we introduce a simple, fully enclosed, and highly integrated microfluidic system based on CRISPR/Cas12a and isothermal amplification techniques (LOC-CRISPR) that can specifically identify multiple common respiratory viruses and their variants. The LOC-CRISPR chip integrates viral nucleic acid extraction, recombinant polymerase amplification, and CRISPR/Cas12a cleavage reaction-based detection, contamination-free detection. In addition, the LOC-CRISPR chip was designed for multiplexed detection (two-sample input and ten-result outputs), which can not only detect the presence of SARS-CoV-2, H1N1, H3N2, IVB and HRSV but also differentiate the BA.1, BA.2, and BA.5 variants of SARS-COV-2. For clinical validation, the LOC-CRISPR chip was used to analyze 50 nasopharyngeal swab samples (44 positive and 6 negative) and achieved excellent sensitivity (97.8%) and specificity (100%). This innovative LOC-CRISPR system has the ability to quickly, sensitively, and accurately detect multiple target nucleic acid sequences with single-base mutations, which will further improve the rapid identification and traceability of respiratory viruses infectious diseases.


Asunto(s)
Técnicas Biosensibles , COVID-19 , Ácidos Nucleicos , Humanos , COVID-19/diagnóstico , Sistemas CRISPR-Cas/genética , Microfluídica , SARS-CoV-2/genética , Técnicas de Amplificación de Ácido Nucleico , Prueba de COVID-19
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA