Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vet Emerg Crit Care (San Antonio) ; 32(6): 748-755, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36161461

RESUMEN

OBJECTIVE: To compare the efficacy of dialysate drainage between Tenckhoff (TC) catheter and Blake (BL) in peritoneal dialysis (PD) in healthy rabbits. DESIGN: Prospective experimental study. SETTING: University Teaching Hospital and University research laboratory. ANIMALS: Twenty healthy, male, New Zealand rabbits. INTERVENTIONS: PD via the TC catheter and the BL abdominal drain was compared during 3 consecutive days of dialysis delivery. MEASUREMENTS AND MAIN RESULTS: One session of PD was performed per day for 3 consecutive days (S1: first session, S2: second session, S3: third session) and each session included 4 cycles of infusion, dwell of dialysate in the abdomen, and drainage. Data collection included daily urea, creatinine, alanine aminotransferase, albumin, and potassium, in addition to hematological parameters (eg, RBC, HCT, hemoglobin, WBC, and platelet count). Statistical analysis using a mixed linear model with multiple comparisons was performed. The BL drain resulted in an increase in volume drained (ml/kg) when compared to TC catheter on S2 (third and fourth cycles) and S3 (first and second cycles). CONCLUSIONS: The BL drain proved to be superior to the TC catheter, being capable of draining a larger volume of dialysate during the drainage processes in the peritoneal PD of healthy rabbits. The TC catheter had major complications with regard to fluid retention in the abdomen, representing reduced drainage efficiency, while the BL drain showed a greater tendency for the peritoneal fluid to leak.


Asunto(s)
Diálisis Peritoneal , Conejos , Masculino , Animales , Estudios Prospectivos , Diálisis Peritoneal/veterinaria , Soluciones para Diálisis , Cateterismo/veterinaria , Catéteres
2.
J Investig Clin Dent ; 5(4): 289-94, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23946239

RESUMEN

AIM: To quantify the microleakage on restorations carried out with a two-step etch-and-rise adhesive system and nanofilled composite resin after thermal and mechanical loading cycling. METHODS: Ninety cavities were prepared on proximal surfaces of incisive teeth, and were randomly divided according to the photoactivation time (10, 20, or 30 s) and light-curing mode (Quartz Tungsten Halogen (QTH) lamps, 450 mW/cm(2); Light Emitting Diode (LED) second generation, 1100 mW/cm(2); or LED third generation, 700 mW/cm(2)) of an adhesive system (n = 10). Following restorative procedures and thermal and mechanical loading cycling, the samples were immersed in Methylene Blue for 2 h. The samples were ground, and the powder was prepared for analysis in an absorbance spectrophotometer. All results were statistically analyzed by anova and Tukey's test at the 5% level of significance. RESULTS: There were no significant statistical difference in microleakage between the light-curing mode (P = 0.1212) and light-curing time (P = 0.2043). CONCLUSION: Different curing modes and increasing the curing time were not factors that influenced the process of microleakage.


Asunto(s)
Resinas Compuestas/química , Cementos Dentales/química , Filtración Dental/clasificación , Materiales Dentales/química , Restauración Dental Permanente/métodos , Grabado Ácido Dental/métodos , Animales , Bovinos , Colorantes , Luces de Curación Dental/clasificación , Preparación de la Cavidad Dental/clasificación , Restauración Dental Permanente/clasificación , Ensayo de Materiales , Azul de Metileno , Nanocompuestos/química , Ácidos Fosfóricos/química , Polimerizacion , Distribución Aleatoria , Espectrofotometría/instrumentación , Estrés Mecánico , Temperatura , Factores de Tiempo , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA