Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 22(12)2022 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-35746395

RESUMEN

Parkinson's disease affects millions worldwide with a large rise in expected burden over the coming decades. More easily accessible tools and techniques to diagnose and monitor Parkinson's disease can improve the quality of life of patients. With the advent of new wearable technologies such as smart rings and watches, this is within reach. However, it is unclear what method for these new technologies may provide the best opportunity to capture the patient-specific severity. This study investigates which locations on the hand can be used to capture and monitor maximal movement/tremor severity. Using a Leap Motion device and custom-made software the volume, velocity, acceleration, and frequency of Parkinson's (n = 55, all right-handed, majority right-sided onset) patients' hand locations (25 joints inclusive of all fingers/thumb and the wrist) were captured simultaneously. Distal locations of the right hand, i.e., the ends of fingers and the wrist showed significant trends (p < 0.05) towards having the largest movement velocities and accelerations. The right hand, compared with the left hand, showed significantly greater volumes, velocities, and accelerations (p < 0.01). Supplementary analysis showed that the volumes, acceleration, and velocities had significant correlations (p < 0.001) with clinical MDS-UPDRS scores, indicating the potential suitability of using these metrics for monitoring disease progression. Maximal movements at the distal hand and wrist area indicate that these locations are best suited to capture hand tremor movements and monitor Parkinson's disease.


Asunto(s)
Enfermedad de Parkinson , Temblor , Mano , Humanos , Movimiento , Enfermedad de Parkinson/diagnóstico , Calidad de Vida , Temblor/diagnóstico
2.
Anal Methods ; 16(37): 6429-6442, 2024 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-39225227

RESUMEN

'Click' derived 1,2,3-triazole appended scaffolds are intriguing candidates for selective metal ion recognition because of their stereospecificity and efficiency. The presented report uses the 'click' approach to introduce a glyoxal bis-(2-hydroxyanil)-based chemosensor probe (GT) via the CuAAC pathway, which can selectively detect Cu(II) and Pb(II) ions, both of which are among the most hazardous and perturbing environmental pollutants. NMR spectroscopy, IR spectroscopy, and mass spectrometry (LCMS) were used to successfully characterize the synthesized probe. The discerning recognition behaviour of the probe for Cu(II) and Pb(II) ions was established through a chemosensing investigation using fluorescence and UV-vis spectroscopy, wherein the fluorescence spectral analysis demonstrated the probe to mimic the IMPLICATION logic gate. Furthermore, the metal-ligand interaction was also validated by 1H NMR and IR spectroscopy of the synthesized GT-metal complex, and UV-vis spectroscopy was also employed to analyze the effect of time and temperature on the capacity of the probe to bind with Cu(II) and Pb(II) ions. Furthermore, the sensor's atherosclerosis-inhibition potential was investigated in silico utilizing docking analysis with tribbles-1 protein, and a density functional theory (DFT) study enhanced the understanding of its structure using the B3LYP functional and the 6311G++(d,p) basis set.

3.
RSC Adv ; 14(22): 15374-15390, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38741961

RESUMEN

In this study, two novel chalcone-derived 1,2,3-triazole-appended positional isomers (probe 6 and probe 9) were synthesized via the 'CuAAC' (Cu(i) - catalysed alkyne azide cycloaddition) methodology for the purpose of metal ion detection. The synthesized probes underwent characterization utilizing standard spectroscopic methodologies including FTIR, NMR (1H and 13C), and mass spectrometry. Subsequently, the sensing capabilities of these probes were explored using UV-Vis and fluorescence spectroscopy, wherein their selective recognition potential was established for Pb(ii) and Cu(ii), both of which can pose serious health hazards when prevalent in the environment above permissible limits. Both the probes exhibited fairly low limits of detection (LoD), determined as 5.69 µM and 6.55 µM in the case of probe 6 for Pb(ii) and Cu(ii) respectively; whereas the probe 9 exhibited an LoD of 5.06 µM and 7.52 µM for Pb(ii) and Cu(ii), respectively. The job's plot for the probe demonstrates the formation of a 1 : 1 complex between the metal and ligand. Furthermore, the interaction of the free probes with the metal ions in the metal-ligand complex was elucidated through 1H NMR analysis and validated theoretically using Density Functional Theory (DFT) simulations with the B3LYP/6-311G++(d,p) and B3LYP/LANL2DZ basis sets for geometry optimization of the probes and their corresponding metal complexes. These findings offer a reliable approach to Cu(ii) and Pb(ii) ion detection and can be further used for the potential applications in environmental monitoring and analytical chemistry.

4.
RSC Adv ; 14(29): 20908-20922, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38962096

RESUMEN

A new, easy-to-prepare, and highly selective fluorescent chemosensor, i.e., 5-aminoisophthalate-based kojic acid-appended bis-1,2,3-triazole, was synthesized from an alkyne of 5-aminoisophthalic acid and azido-kojic acid using Cu(i)-catalyzed click chemistry and then successfully characterized. The alkyne structure of 5-aminoisophthalic acid, 1, was supported by the single-crystal X-ray crystallographic data. The fluorescent probe 3 was found to be highly selective for Cu2+ ions supported by the Job's plot with a stoichiometric ligand : metal ratio of 2 : 1, exhibiting almost a two-fold enhancement in the emission intensity upon the addition of Cu2+ ions (0-25 µM) with a detection limit of 8.82 µM. A comparison with LODs from previously developed chemosensors for Cu2+ ions was also conducted. Reversibility analysis indicated that probe 3 could be used as both a reusable sensor and as a scavenger of copper ions. DFT calculations with the basis sets B3LYP/6-311G(d,p) and LanL2DZ were employed for geometrical optimizations of structures of the alkyne 1, azide 2, probe 3, and complex 3.Cu2+. Hirshfeld surface analysis revealed significant intermolecular interactions in compound 1. Additionally, molecular docking for the antimicrobial activity showed the better antibacterial efficacy of probe 3.

5.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124319, 2024 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-38663133

RESUMEN

Schiff base linked1,2,3-triazole silane5has been synthesized through the Schiff base terminated alkyne with azido via click chemistry,the compound4 structure elucidated through X-ray crystallography, and the compound5 is well characterized through different techniques such asFT-IR, 1H and 13C NMR and Mass spectrometry. UV-visible sensing studies of synthesized compounds4 and5 have been performed, and both are efficient in detectingZn(II) ion, but compound 5 has imparted a higher mode of attraction to Zn(II) with limit of detection (LOD) value (1.4 x 10-6M) wherethe compound 4 is calculated to be (1.25 x 10-5M). By Job's method, the stoichiometric ratio of compound5 and Zn(II) iscalculated to bea 1:1 ratio. The complex of compound 5 with Zn(II) was prepared. A radical and oxidative species are responsible for the deteriorating of stabilized molecules. The synthesized compound 5hasantioxidant propertiesthat can potentially scavenge 2,2-diphenyl-1-picrylhydrazyl (DPPH) radicals. Further to verify the mode of binding interaction between compound 5andZn(II), computational Density functional theory (DFT) study was evaluated.

6.
RSC Adv ; 14(11): 7383-7413, 2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38433942

RESUMEN

In the quest to scrutinize and modify biological systems, the global research community has continued to explore bio-orthogonal click reactions, a set of reactions exclusively targeting non-native molecules within biological systems. These methodologies have brought about a paradigm shift, demonstrating the feasibility of artificial chemical reactions occurring on cellular surfaces, in the cell cytosol, or within the body - an accomplishment challenging to achieve with the majority of conventional chemical reactions. This review delves into the principles of bio-orthogonal click chemistry, contrasting metal-catalyzed and metal-free reactions of bio-orthogonal nature. It comprehensively explores mechanistic details and applications, highlighting the versatility and potential of this methodology in diverse scientific contexts, from cell labelling to biosensing and polymer synthesis. Researchers globally continue to advance this powerful tool for precise and selective manipulation of biomolecules in complex biological systems.

7.
RSC Adv ; 13(46): 32399-32412, 2023 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-37928840

RESUMEN

Herein, a 1,2,3-triazole derivative (CBT), synthesized using the Copper(i) catalyzed Alkyne Azide Cycloaddition (CuAAC) procedure, based on a chalcone skeleton has been reported, that was implemented as an effective sensor for Pb(ii) and Cu(ii) ions. The synthesized CBT was characterized using spectroscopic techniques such as FTIR, NMR (1H and 13C), and mass spectrometry. The sensing behaviour of CBT was analyzed using UV-Vis spectroscopy, demonstrating selective sensing for Pb(ii) and Cu(ii) ions, competitively. The correlation plot revealed the detection limit for Pb(ii) and Cu(ii) ions to be 100 µM and 110 µM respectively. In addition, DFT simulations and molecular electrostatic potential (MEP) studies scrutinized the binding strategy of the free CBT and its orientation towards the metal ions in the metal-ligand complex. The probe CBT was predicted via the online platform Way2drug for its pharmacological properties, investigating the possibility to inhibit early atherosclerosis. CBT was subsequently docked to the TRIB1 protein using AutoDock Vina and demonstrated a high binding affinity with a value of -6.2 kcal mol-1.

8.
RSC Adv ; 13(5): 2912-2936, 2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36756399

RESUMEN

Copper(i) catalyzed alkyne azide cycloaddition (CuAAC), the quintessential example of 'click chemistry', provides an adaptable and adequate platform for the synthesis of nanogels for sustained drug release at targeted sites because of their better biocompatibility. The coupling of drugs, carried out via various synthetic routes including CuAAC, into long-chain polymeric forms like nanogels has exhibited considerable assurance in therapeutic advancements and intracellular drug delivery due to the progression of water solubility, evacuation of precocious drug release, and improved upthrust of the pharmacokinetics of the nanogels, thereby rendering them as better and efficient drug carriers. The inefficiency of drug transmission to the target areas due to the resistance of complex biological barriers in vivo is a major hurdle that impedes the therapeutic translation of nanogels. This review compiles the data of nanogels synthesized specifically via CuAAC 'click' methodology, as scaffolds for targeted drug delivery and their assimilation into nanomedicine. In addition, it elaborates the ability of CuAAC to graft specific moieties and conjugating biomolecules like proteins and growth factors, onto orthogonally functionalized polymer chains with various chemical groups resulting in nanogels that are not only more appealing but also more effective at delivering drugs, thereby enhancing their site-specific target approach and initiating selective therapies.

9.
Spectrochim Acta A Mol Biomol Spectrosc ; 302: 123163, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-37478755

RESUMEN

The present report describes the application of the 'Click Chemistry' pathway to synthesize a fluorescent probe (APT) based on ampyrone (4-aminoantipyrine), entailing two benzyl groups as the fluorophores coupled to the antipyrine structure through 1,2,3-triazole moieties. Infrared spectroscopy (IR), nuclear magnetic resonance (1H and 13C), and mass spectrometry were the standard spectroscopic methods used to characterize APT. The ion recognition potential of the probe was analyzed through absorption and emission spectroscopy employing a 4:1 combination of CH3CN and H2O, which demonstrated APT to be an efficient sensing agent for Cu(II) ions, wherein the absorption spectrum of the probe displayed a hypsochromic shift with a hyperchromic shift on gradually adding the metal ion solution of Cu(II), whereas quenching of the probe's fluorescence emission on Cu(II) addition was attributed to the chelation-enhanced fluorescence quenching (CHEQ), induced by the d9 electronic configuration of Cu(II). The stoichiometry of the complexation of APT with Cu(II) is indicative of a 1:1 ratio, while the detection limit (LOD) and quantification limit (LOQ) as estimated from the fluorescence titration results were 3.11 µM and 10.35 µM respectively. Furthermore, DFT analysis was also undertaken to yield the energy-optimized structures and HOMO-LUMO density plots of APT and its corresponding Cu(II) complex via the B3LYP/631G+(d,p) level of theory for APT, and LANL2DZ basis set for the APT-Cu(II) complex. Docking analysis of the probe with the synaptic vesicle protein (SV2A) gave glimpses about its anticonvulsant properties.

10.
ACS Omega ; 7(43): 39159-39168, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36340062

RESUMEN

Copper(I)-catalyzed alkyne-azide cycloaddition (CuAAC) is a resourceful and stereospecific methodology that has considerably yielded promising 1,2,3-triazole-appended "click" scaffolds with the potential for selective metal ion recognition. Based on "click" methodology, this report presents a chemosensor probe (TCT) based on 4-tert-butylcatechol architecture, via the CuAAC pathway, as a selective and efficient sensor for Pb(II) and Hg(II) ions, categorized as the most toxic and alarming environmental contaminants among the heavy metal ions. The synthesized probe was successfully characterized by spectroscopy [IR and NMR (1H and 13C)] and mass spectrometry. The chemosensing study performed in acetonitrile/water (4:1) solvent media, via UV-vis and fluorescence spectroscopy, established its selective sensitivity for Pb(II) and Hg(II) species among the list of explored metal ions with the limits of detection being 8.6 and 11 µM, respectively. Additionally, the 1H NMR and IR spectra of the synthesized TCT-metal complex also confirmed the metal-ligand binding. Besides, the effect of time and temperature on the binding ability of TCT with Pb(II) and Hg(II) was also studied via UV-vis spectroscopy. Furthermore, density functional theory studies put forward the structural comprehension of the sensor by availing the hybrid density functional (B3LYP)/6311G++(d,p) basis set of theory which was subsequently utilized for investigating its anti-inflammatory potential by performing docking analysis with human leukotriene b4 protein.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA